SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

Similar documents
HYDRONIC System. HYDRONIC System. The complete range of chillers, heat pumps and air handling units in large installations

PACKAGED System. PACKAGED System Packaged air conditioning for retail, service and high attendance applications

LZT High efficiency air to water heat pumps with E.V.I. compressors

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

PRODUCT GUIDE

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

LZT High efficiency air to water heat pumps with E.V.I. compressors

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CHAPTER 6 CONDENSING UNITS

Air Cooled Chillers & Heat Pumps WinPACK HE-A

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

LZA High efficiency air to water heat pumps with HP compressor


GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES

CRIMSON & CRIMSON MAX

Precision air handling cabinets Ciatronic MICRO/EXPAIR

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Vertical self-contained air conditioner

YORK Close Control units

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Water chillers water/water type SIGMA Technical information manual

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

GHE Dehumidifiers for radiant cooling systems with heat recovery

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

AQUASNAP JUNIOR 30RHV

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Air cooled industrial chillers

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

K Series Modular air conditioners. With direct expansion coil With chilled water coil

LZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES

ELFOEnergy Duct Inverter

Commercial High-Efficiency Condensing Units

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

Modular Air-cooled Chillers

kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

DATATECH. Precision air conditioners for technological environments 6 220

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

HYDRONIC RESIDENTIAL

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw


ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Blue Box Epsilon Echos +

Fan Coil Range HYDRONIC TERMINALS

TECNAIR LV C series Close control air conditioners

TECNAIR LV C series Close control air conditioners

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

WZH Ground source heat pumps

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Compact and silent Scroll compressors All-season operation

GEYSER kw. General information. Unique selling points

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

Transcription:

System System Simple and flexible direct expansion solutions for the commercial sector and industry System is the autonomous solution for climate control in small and medium shops. The cooling or thermal energy needed is produced locally in each serviced zone, without any sharing taking place with the remaining commercial units. These systems are very flexible, adapting easily to all installation situations. 196

System components series size from to name page ondensing units - air source - axial fans MSAN-X 17 71-198 MSAT / MSAN 81 242-200 MSAT 292 604-202 MSAT-S 65D 180F SPINchiller 204 ondensing units - air source - centrifugal fans MA / MN 91 242-206 ondensing units - water source MH 21 422-208 Split system - air source MSAN-X + N-X 17 71-210 MA / MN + ED / N - ED-V / N-V 91 242-212 MSAT / MSAN + ED / N - ED-V / N-V 81 242-214 197

MSAN-X 17 71 ondensing unit 4Reversible heat pump Air cooled Outdoor installation apacity from 7,02 to 19 kw These appliances are the outdoor unit of the SYSTEMS. They may be combined with our N-X series terminal units or connected to exchanger coils of air-handling units. The use of external rotor fans with a low number of revs, the complete thermal and acoustic insulation of the compressor compartment, the variable speed of fans and the adoption of the "SROLL" compressor make the MSAN-X unit particularly silent. Moreover, the reduced dimensions allow it to be installed in small spaces. All the units feature the new control and microprocessorregulation systems which optimize the performances and include: 4 display for the visualization of the state of operation and of the alarms 4 control over condensation based on the temperature of fresh air (modulating variation of the fan speed) 4 control over defrosting 4 compressor functioning time count 4 possibility of connection to a supervisor functions and features AIR R-410A Heating-ooling Air cooled Outdoor inst. Refrig. R-410A Herm. Scroll Ice protection system available configurations (1) (2) MSAN-X 17 400TN - (3) S (1) SUPPLY VOLTAGE: 4400TN 400/3/50+N 4230M 230/1/50 (sizes 17 31) (2) SOFT STARTER: 4- Not required (Standard) 4SFSTR4N Device for inrush current reduction for 400/3/50+N 4SFSTR1 Device for inrush current reduction for 230/1/50 (3) ONDENSER OIL: 4S Standard condenser coil 4A ondenser coil in copper/aluminium with acrylic coating 4A1 ondenser coil in copper/aluminium with Energy Guard D Aluminium treatment 4 ondenser coil in copper/copper 198

4 Rubber antivibration mounts 4 Remote keypad 4 Serial communication module P/BMS MODBUS for 1 unit (Master) 4 Serial communication module P/BMS MODBUS from 2 to 254 units (Slave) 4 onnection set (thermostat, dehydrating filter, liquid flow gauge, check valve) 4 Phase monitor Key to symbols: Accessories supplied separately. technical data 17 21 31 41 51 61 71 4 ooling capacity (1) kw 7,02 7,53 8,99 11,8 15,0 17,9 19,0 Total input (1) kw 1,52 1,63 2,03 2,62 3,75 4,67 5,06 4 Heating capacity (2) kw 6,54 6,99 8,73 11,7 15,0 17,6 18,7 kw 1,38 1,52 1,72 2,36 3,12 3,74 3,98-1 SROLL Total input (2) Number and type of compressors Sound pressure level (3) db(a) 56 56 57 57 59 59 59 V/Ph/Hz 400/3/50+N Data referred to the following conditions: (1) Saturated suction temperature (SST)= 9.5 ; exchanger air temperature = 35 (2) Exchanger air temperature = 7 D.B./ 6 W.B.; Dew point = 40 (3) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances leave free A1 A2 leave free 17 21 31 41 51 61 71 Length (A) mm 800 800 800 800 800 800 800 Width (B) mm 300 300 300 300 300 300 300 Height () mm 1242 1242 1242 1372 1372 1372 1372 mm 100 100 100 100 100 100 100 (A2) mm 500 500 500 500 500 500 500 (B2) mm 150 150 150 150 150 150 150 A 17 31 B B2 A1 A A2 41 71 B B2 AUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. 199

MSAT MSAN 81 242 ondensing unit 4MSAT: cooling only 4MSAN: reversible heat pump Air cooled Outdoor installation apacity from 22 to 72,8 kw These appliances are the outdoor unit of the SYSTEMS. They may be combined with our ED, ED-V (cooling only) or N, N-V (heat pump) series terminal units or connected to exchanger coils of air-handling units. The use of low-rev external rotor fans, full thermal and acoustic insulation of the compressor compartment, variable fan speed and SROLL compressor make the units particularly low noise. Their reduced overall size also allows installation in restricted spaces. All units are fitted with the new microprocessor control and regulation system, which optimises performance. functions and features AIR R-407 ooling only (MSAT) Heating-ooling (MSAN) Air cooled Outdoor inst. Refrig. R-407 Herm. Scroll Ice protection system (MSAN only) available configurations (1) (2) MSAT S 81 ST (3) T (1) VERSION: 4S Standard (2) AOUSTI ONFIGURATION: 4ST Standard (3) ENERGY EFFIIENY: 4T Temperate climate 200

4 Rubber antivibration mounts 4 Remote keypad 4 ondenser coil in copper/aluminium with acrylic coating 4 opper/copper condenser coil 4 Serial communication module P/BMS MODBUS for 1 unit (Master) 4 Serial communication module P/BMS MODBUS from 2 to 254 units (Slave) 4 Low external air temperature pressure-switch device 4 oil protection grilles on external air side 4 Phase monitor 4 Supply voltage 230/3/50 MSAT only: 4 Hot gas by pass 4 onnection set (thermostat, solenoid valve, dehydrating filter, liquid flow gauge) MSAN only: 4 onnection set (thermostat, dehydrating filter, liquid flow gauge, check valve) Key to symbols: Accessories supplied separately. technical data MSAT 81 91 101 121 102 122 142 162 182 202 242 4 ooling capacity (1) kw 22,0 26,7 30,9 38,1 29,8 34,1 39,2 44,1 50,3 62,8 72,8 kw 6,70 8,20 9,80 12,10 9,80 11,6 13,2 15,3 18,4 21,2 26,1-1 SROLL 2 SROLL Total input (1) Number and type of compressors Sound pressure level (3) db(a) 60 61 60 61 59 59 60 60 60 61 62 V/Ph/Hz 400/3/50+N MSAN 81 91 101 121 102 122 142 162 182 202 242 4 ooling capacity (1) kw 21,8 25,8 30,9 37,6 - - 39,2 44,1 50,3 62,8 72,8 Total input (1) kw 6,82 8,60 9,83 12,3 - - 13,4 15,5 18,6 21,5 26,4 4 Heating capacity (2) kw 22,6 26,7 31,7 38,9 - - 42,0 45,9 54,6 65,2 77,7 kw 5,12 6,23 7,40 8,90 - - 9,10 10,5 12,7 14,8 17,8-1 SROLL - - 2 SROLL Total input (2) Number and type of compressors Sound pressure level (3) Data referred to the following conditions: db(a) 60 61 60 61 - - 60 60 60 61 62 V/Ph/Hz 400/3/50+N (1) Saturated suction temperature (SST) = 9,5 (Dew Point); external air temperature 35 (2) Air at external exchanger inlet = 6,1 W.B.; condensing temperature = 40 ; (3) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances B1 B A1 A A2 102 242 81 121 81 91 101 121 102 122 142 162 182 202 242 Length (A) mm 1373 1373 1573 1573 1530 1530 1563 1563 1563 2098 2098 Width (B) mm 557 557 557 557 678 678 1107 1107 1107 1107 1107 Height () mm 1225 1225 1225 1225 1400 1400 1570 1570 1570 1570 1570 mm 200 200 200 200 1000 1000 1000 1000 1000 1000 1000 (A2) mm 500 500 500 500 1000 1000 1000 1000 1000 1000 1000 (B1) mm 200 200 200 200 800 800 900 900 900 900 900 (B2) mm - - - - 800 900 900 900 900 900 900 MSAT Weight in oper. kg 164 199 244 254 254 264 344 364 444 534 544 MSAN Weight in oper. kg 167 202 247 257 - - 347 367 447 537 547 A1 A A2 B B2 B1 AUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. 201

MSAT 292 604 ondensing unit 4ooling only Air cooled Outdoor installation apacity from 90,1 to 174 kw The MSAT air-cooled condensing units have been designed for outdoor installation and for best energy efficiency in relation to reduced size. The compressors are of the hermetic Scroll type. They are fitted with an innovative microprocessor control for regulating and optimising all unit functions, thereby increasing the energy efficiency. An enamelled, hot-galvanised sheet metal load-bearing frame with prepainted aluminium outer panelling ensures maximum resistance to weathering. The base, made from painted galvanised metal sections with holes to facilitate lifting and earthing the unit, guarantees even weight distribution. All the units are factory assembled and tested and ready for operation after connection, with consequent substantial reduction in installation costs. functions and features AIR R-407 ooling only Air cooled Outdoor inst. Refrig. R-407 Herm. Scroll available configurations (1) MSAT-2 - (2) 564 ST (3) T (4) (1) ENERGY REOVERY: 4- Standard 4D Partial recovery arried out using tube bundle exchargers suited for recovering the desuperheating heat up to a maximum of 25% of the total unit heat. (3) ENERGY EFFIIENY: 4T Temperate climate (Standard) (4) EXHANGER APPROVALS: 4E PED (European test) 4 livet (In-house test) (2) AOUSTI ONFIGURATION: 4ST Standard 4LN Silenced This set-up is obtained by inserting the compressors in a soundproofed compartment and reducing the fan speed of rotation with an uprated condensing section. 202

4 ondenser coil in copper/aluminium with acrylic coating 4 ondenser coil in copper/aluminium with Energy Guard D Aluminium treatment 4 Spring antivibration mounts 4 Finned coil protection grilles 4 onnection set (thermostat, filter, etc) 4 Hot gas by pass 4 Phase monitor 4 Magnetothermal circuit breakers 4 Shunt capacitors (power factor > 0,9) 4 Serial communication module with supervisor (MODBUS) 4 Remote control with remote microprocessor control Key to symbols: Accessories supplied separately. technical data 292 323 404 464 524 564 604 ST 4ooling capacity (1) kw 90,1 106 121 137 152 162 174 ST Total input kw 30,4 33,7 39,1 45,4 51,9 56,2 59,9 ST Sound pressure level (2) db(a) 72 74 76 77 77 77 77 LN 4 ooling capacity (1) kw 85,8 102 117 131 145 155 164 LN Total input kw 30,8 33,8 38,5 45,4 52,4 57,1 62,0 LN Sound pressure level (2) db(a) 63 65 67 67 68 68 68 Number of refrigerant circuits - 2 Number and type of compressors - 2 SROLL 3 SROLL 4 SROLL V/Ph/Hz 400/3/50 Data referred to the following conditions: (1) Saturated suction temperature (SST) = 9,5 (Dew Point); external air temperature 35 (2) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances B1 leave free B B2 A A2 292 323 404 464 524 564 604 Length (A) mm 3250 3250 3250 3250 3250 3250 3250 Width (B) mm 1095 1095 1095 1095 1095 1095 1095 Height () mm 2030 2030 2030 2030 2030 2030 2030 mm 1500 1500 1500 1500 1500 1500 1500 (A2) mm 900 900 900 900 900 900 900 (B1) mm 1500 1500 1500 1500 1500 1500 1500 (B2) mm 1500 1500 1500 1500 1500 1500 1500 ST Weight in oper. kg 1225 1336 1486 1511 1534 1577 1612 LN Weight in oper. kg 1256 1367 1516 1544 1565 1607 1644 A1 AUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. 203

MSAT-S 65D 180F ondensing unit 4ooling only Air cooled Outdoor installation apacity from 210 to 588 kw SPINHILLER The SPINchiller series presents a new concept of condensing unit offering: 4EFFIIENY that increases as the heating load decreases, while guaranteeing maximum requested load when necessary. SPINchiller always ensures maximum comfort with very high efficiency and consequently considerable energy savings; 4customisation of the unit with the EOBreeze accessory, which enhances the qualities of flexibility and energy efficiency; 4easy connection to the service system plus a simple control system and easy maintenance drastically reduce work requiring specialised personnel with consequent reduction in installation costs; 4customisation of the unit, also for special requirements both in the civil and technological air-conditioning sphere, thanks to the many available optional. The innovative and hi-tech features of SPINchiller give this series a much higher quality than can generally be found on the market today. MSAT-S is a condensing unit series for use together with a remote evaporating section. functions and features AIR R-407 EO BREEZE ooling only Air cooled Outdoor inst. Refrig. R-407 Herm. Scroll EOBreeze available configurations MSAT-S (1) D 65D (2) EN (3) T (4) (1) ENERGY REOVERY: 4- Not required 4D Partial recovery arried out using braze-welded plate-type exchangers suited for recovering the desuperheating heat up to a maximum of 20% of the total unit heat. (3) ENERGY EFFIIENY: 4T Temperate climate (Standard) (4) EXHANGER APPROVALS: 4E PED (European test) 4 livet (In-house test) (2) AOUSTI ONFIGURATION: 4S ompressor soundproofing This set-up is obtained by inserting the compressors in a soundproofed compartment. 4EN Super Silenced This set-up is obtained by soundproofing the compressor compartment even more and reducing the fan speed of rotation with an uprated condensing section. 204

4 ondenser coil in copper/aluminium with acrylic coating 4 ondenser coil in copper/aluminium with Energy Guard D Aluminium treatment 4 Spring antivibration mounts 4 ompressor compartment and condenser coil protection grilles 4 Hail grilles 4 Shut-off valve on compressor supply and return 4 onnection set (thermostat, filter, etc) 4 High and low pressure gauges 4 Device for reducing consumption of the outdoor section fans of the EcoBreeze type 4 Phase monitor 4 Shunt capacitors (power factor > 0,9) 4 AN/MODBUS serial converter kit 4 AN/LonWorks serial converter kit 4 Free contacts for compressor status 4 Remote control with remote microprocessor control Key to symbols: Accessories supplied separately. technical data 65D 70D 75D 80D 90D 100D 110D 120D 135F 150F 165F 180F S 4ooling capacity (1) kw 210 226 240 255 278 318 363 386 429 462 518 588 S Total input kw 64,8 69,5 75,9 82,2 89,5 96,8 112 126 139 156 179 193 S Total EER at 100% - 3,25 3,25 3,17 3,10 3,10 3,29 3,25 3,06 3,10 2,95 2,90 3,04 S Sound pressure level (2) db(a) 76 76 76 76 76 76 78 78 78 78 79 79 EN 4 ooling capacity (1) kw 204 220 231 244 264 300 350 379 406 450 500 551 EN Total input kw 63,7 69,5 77,1 84,0 92,1 103 111 125 141 159 179 199 EN Total EER at 100% - 3,20 3,16 2,99 2,90 2,87 2,92 3,15 3,02 2,88 2,82 2,79 2,77 EN Sound pressure level (2) db(a) 67 68 68 68 68 68 70 70 71 71 72 72 Number of refrigerant circuits - 2 Number and type of compressors - 4 SROLL 6 SROLL V/Ph/Hz 400/3/50 Data referred to the following conditions: (1) Saturated suction temperature (SST) = 9,5 (Dew Point); external air temperature 35 (2) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances B1 B B2 leave free A A2 65D 70D 75D 80D 90D 100D 110D 120D 135F 150F 165F 180F Length (A) mm 2950 2950 2950 2950 2950 2950 4250 4250 4250 4250 4250 4250 Width (B) mm 2195 2195 2195 2195 2195 2195 2195 2195 2195 2195 2195 2195 Height () mm 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410 2410 mm 700 700 700 700 700 700 700 700 700 700 700 700 (A2) mm 700 700 700 700 700 700 700 700 700 700 700 700 (B1) mm 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300 (B2) mm 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 S Weight in oper. kg 2102 2164 2226 2288 2293 2298 2926 2984 3113 3120 3506 3670 EN Weight in oper. kg 2112 2184 2246 2308 2313 2318 2876 3009 3203 3300 3596 3650 A1 AUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. 205

MA MN 91 242 ondensing unit 4MA: cooling only 4MN: reversible heat pump Air cooled Indoor installation apacity from 26,6 to 77,8 kw The MA and MN series of condensing units and heat pumps offers the possibility of making systems in two sections connected to our ED, ED-V (cooling only) or N, N-V (heat pump) units or to exchanger coils of air-handling units. The units are designed for indoor installation. The use of low-rev centrifugal fans and special thermal and acoustic insulation of the cabinet have resulted in a high reduction in sound levels. The head pressures available with centrifugal fans enable wide ducting for air return and cooled air discharge to be installed. functions and features AIR R-407 ooling only (MA) Heating-ooling (MN) Air cooled Indoor inst. Refrig. R-407 Herm. Scroll available configurations MA (1) S (2) 91 ST (3) T (1) VERSION: 4S Standard (2) AOUSTI ONFIGURATION: 4ST Standard (3) ENERGY EFFIIENY: 4T Temperate climate 206

4 Rubber antivibration mounts 4 Low external air temperature pressure-switch device 4 High and low pressure gauges 4 Supply fan uprated electric motor 4 Phase monitor 4 Air supply plenum MA only: 4 onnection set (thermostat, solenoid valve, dehydrating filter, liquid flow gauge) MN only: 4 ondensate collecting tray with heating element 4 onnection set (thermostat, dehydrating filter, liquid flow gauge, check valve) Key to symbols: Accessories supplied separately. technical data 91 101 121 142 182 202 242 4 ooling capacity (1) kw 26,6 31,9 37,8 40,6 53,2 63,2 77,8 Total input (1) kw 9,00 10,3 13,0 13,5 18,0 21,8 26,1 4 Heating capacity (2) kw 27,2 32,4 38,5 39,4 54,2 63,5 77,8 Total input (2) kw 7,00 8,30 9,80 10,4 14,1 17,6 20,7 Number and type of compressors - 1 SROLL 2 SROLL Sound pressure level (3) db(a) 69 57 58 62 60 61 62 V/Ph/Hz 400/3/50 Data referred to the following conditions: (1) Saturated suction temperature (SST) = 9,5 (Dew Point); Ambient temperature = 35 ; (2) Dew point = 40 ; internal exchanger inlet temperature = 6,1 W.B.; (3) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances 91 182 A1 A A2 B2 B B1 202 242 91 101 121 142 182 202 242 Length (A) mm 1517 1780 1780 2230 2230 2230 2230 Width (B) mm 758 846 846 978 978 978 978 Height () mm 1130 1205 1205 1430 1430 1705 1705 mm 500 500 500 500 500 500 500 (A2) mm 400 400 400 400 400 400 400 (B1) (*) mm 70+R 70+R 70+R (**) (B2) mm 500 500 500 500 500 500 500 Weight in oper. kg 336 385 392 594 635 715 720 Notes: (*) R = Return space; (**) Leave free. B1 B B2 A A2 A1 AUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. 207

MH 21 422 ondensing unit 4ooling only Water cooled Indoor installation apacity from 8,2 to 177 kw The MH series of indoor water-cooled condensing units are suited for SYSTEMS, being designed for connection to split type airhandling units. They may be installed in combination with our terminal units in the ED - EI - ED-V series. The units from size 102 to size 242 may be connected to two indoor units always from the ED - EI - ED-V series. The reduced overall size allows their installation in restricted spaces. Every unit is factory tested and arrives on site ready for use. functions and features H 2 O R-407 ooling only Water cooled Indoor inst. Refrig. R-407 Herm. Scroll available configurations MH 101 208

4 onnection set (thermostat, solenoid valve, dehydrating filter, liquid flow gauge) 4 Pressure-controlled valve 4 Steel mesh filter on water side 4 Supply voltage 230/1/50 (sizes 25-31) 4 Supply voltage 400/3/50 without neutral (size 21) 4 Supply voltage 230/3/50 (sizes 51 242) Key to symbols: Accessories supplied separately. MH 102 422 only: 4 Manifold for unit with double exchanger technical data 21 25 31 51 71 91 101 121 4 ooling capacity (1) kw 8,20 9,80 11,3 18,3 25,5 31,7 36,8 43,4 Total input kw 1,70 2,00 2,60 3,80 5,00 7,10 7,80 10,1 Number and type of compressors - 1 SROLL Sound pressure level (2) db(a) 49 49 49 50 50 59 60 62 V/Ph/Hz 230/1/50 400/3/50 102 142 182 202 242 292 322 362 422 4 ooling capacity (1) kw 35,7 50,9 63,5 73,6 90,9 109 128 147 177 Total input kw 7,60 10,1 14,2 15,8 20,3 19,9 23,6 27,8 33,9 Number and type of compressors - 2 SROLL Sound pressure level (2) db(a) 53 53 62 63 65 66 65 66 66 V/Ph/Hz 400/3/50 Data referred to the following conditions: (1) Saturated suction temperature (SST) = 9,5 (Dew Point); external exchanger water = 25/35 (2) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. dimensions and clearances 21 25 31 51 71 91 101 121 Length (A) mm 402 402 402 402 402 402 402 402 Width (B) mm 487 487 487 602 602 602 602 602 Height () mm 790 790 790 790 790 915 915 915 mm 300 300 300 300 300 300 300 300 (A2) mm 300 300 300 300 300 300 300 300 (B1) mm 500 500 500 500 500 500 500 500 (B2) mm 300 300 300 300 300 300 300 300 Weight in oper. kg 46 46 46 47 47 56 57 59 AUTION! A1 A A2 B1 B B2 For trouble-free operation of the unit it is essential to maintain the clearances in green. 102 142 182 202 242 292 322 362 422 Length (A) mm 802 802 802 802 802 580 580 580 580 Width (B) mm 602 602 602 602 602 1062 1062 1062 1062 Height () mm 790 790 915 915 915 1538 1538 1538 1538 mm 300 300 300 300 300 300 300 300 300 (A2) mm 300 300 300 300 300 300 300 300 300 (B1) mm 500 500 500 500 500 500 500 500 500 (B2) mm 300 300 300 300 300 300 300 300 300 Weight in oper. kg 155 190 229 236 247 407 442 465 517 209

MSAN-X + N-X 17 71 Split system 4Reversible heat pump Air cooled apacity from 6,5 to 18,8 kw N-X 17 71 MSAN-X 17 71 HID-T2 The environmental control HID-T2 makes it possible to interface directly with the adjustment module of the units equipped with livet Talk Split and to manage one or more units. The ambient thermostat allows the following functions: 4 Setting of the desired temperature 4 Selection among 3 possible speeds (MIN - MED - MAX) manual or automatic 4 On/Off 4 hange Summer/Winter automatically or manually with digital input 4 Selection of economic operation 4 Setting of unit operation parameters 4 ontrol of fresh air shutter and control of motorized air supply grid, if present 4 Management of diagnostics with specific code for type of error LIVET SOLUTIONS MSAN-X + N-X is the most versatile offer available today for this type of two-section system. The MSAN-X unit is the outdoor part of the system combined with the N-X, direct expansion ductable indoor terminal units. The electronic controls on all the units enable a broader use of the system, allowing integrated control of all devices inserted in the system. LIVET SOLUTIONS a universal system: 4suitable for any type of installation 4with a wide range of for all configurations 4with an extremely sophisticated room control 4the indoor units are fitted with high head pressure fans for air distribution via ductwork. functions and features AIR R-410A Heating-ooling Air cooled Refrig. R-410A Herm. Scroll Ice protection system technical data 210 17 21 31 41 51 61 71 4 ooling capacity (1) kw 6,50 7,00 8,47 11,3 15,0 17,0 18,8 EER - 3,44 3,57 3,54 3,64 3,68 3,22 3,21 4 Heating capacity (2) kw 6,35 6,90 8,47 11,2 15,0 17,2 18,1 OP - 3,91 3,91 4,22 3,98 3,99 3,94 3,94 Number of refrigerant circuits - 1 Number and type of compressors - 1 SROLL MSAN-X 4 Total input (1) kw 1,87 1,94 2,32 3,07 4,01 5,27 5,94 4 Total input (2) kw 1,65 1,79 2,06 2,84 3,81 4,45 4,66 Sound pressure level (3) N-X Total input Air flow rate (max. speed) (4) Max. working static pressure (5) Sound pressure level (min-med-max) (3) Data referred to the following conditions: Data referred to coupling with our terminal unit N-X 17-71 of the same size and in tri-phase versions with compressors 400/3/50+N (1) Internal exchanger air temperature 27 D.B./ 19,5 W.B.; ambient temperature = 35. Total input is obtained from the compressor input + fan input. (2) Internal exchanger air temperature 20. internal external exchanger air temperature 7 D.B./6 W.B. db(a) 56 56 57 57 59 59 59 V/Ph/Hz 400/3/50+N kw 0,43 0,43 0,53 0,53 0,86 1,17 1,17 l/s 428 428 676 687 936 822 1109 Pa 102 102 125 65 150 110 110 db(a) 47-51-54 47-51-54 47-52-55 48-53-56 48-54-57 49-54-58 49-54-58 V/Ph/Hz 230/1/50 (5) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. (4) Air flow rate at maximum speed with available head of 0 Pa. (5) Maximum available working static pressure at maximum speed

MSAN-X 17 71 4 Remote keypad 4 Rubber antivibration mounts 4 Serial communication module P/BMS MODBUS for 1 unit (Master) 4 Serial communication module P/BMS MODBUS from 2 to 254 units (Slave) 4 Phase monitor Key to symbols: Accessories supplied separately. dimensions and clearances 17 31 41 71 A1 A A2 B B2 MSAN-X 17 21 31 41 51 61 71 Length (A) mm 800 800 800 800 800 800 800 Width (B) mm 300 300 300 300 300 300 300 Height () mm 1242 1242 1242 1372 1372 1372 1372 mm 100 100 100 100 100 100 100 (A2) mm 500 500 500 500 500 500 500 (B2) mm 150 150 150 150 150 150 150 A1 A A2 B B2 N-X 17 71 4 Hot water coil with 2 rows 4 4,5 kw electric heaters 4 6 kw electric heaters 4 9 kw electric heaters 4 12 kw electric heaters 4 Mixing and recirculation plenum 4 Air supply plenum for round ducts 4 Remote keypad 4 Phase monitor 4 Serial communication module RS485 Key to symbols: Accessories supplied separately. dimensions and clearances A1 A A2 B N-X 17 21 31 41 51 61 71 Length (A) mm 1055 1055 1155 1395 1395 1395 1395 Width (B) mm 580 580 600 650 650 650 650 Height () mm 297 297 322 322 372 422 422 mm 200 200 200 200 200 200 200 (A2) mm 400 400 400 400 400 400 400 AUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. 211

MA MN + ED / ED-V N / N-V 91 242 Split system 4MA + ED, ED-V: cooling only 4MN + N, N-V: reversible heat pump Air cooled apacity from 24,4 to 73,9 kw ED 91 242 N 91 242 MA/MN 91 242 ED-V 91 242 N-V 91 242 The HID-S1 room control design is user-friendly. Setting operations is simple with the large liquid crystal display. Functions: 4 On/Off 4 required temperature setting 4 manual or automatic SUMMER-WINTER setting 4 operation in fan mode only setting 4 manual or automatic FAN SPEED setting (3 speeds) 4 display of outdoor unit status (active compressor) 4 display of alarms 4 modulating signal for 0-10V valves or electric heater control The MA + ED + ED-V cooling only or MN + N + N-V with heat pump split system is the most versatile offer available today for this type of two-section system. The MA (or MN) unit is the outdoor part of the system combined with the direct expansion ductable indoor terminal units for horizontal installation in suspended ceiling ED (or N) and for vertical cased installation ED-V (or N-V). The electronic controls on all the units enable a broader use of the system, allowing integrated control of all devices inserted in the system. The two-circuit condensing units may be connected to two indoor units. functions and features AIR R-407 ooling only (MA+ED/ED-V) Heating-ooling (MN+N/N-V) Air cooled Refrig. R-407 Herm. Scroll technical data 91 101 121 142 182 202 242 4 ooling capacity (1) kw 24,4 31,2 37,5 38,7 50,4 62,4 73,9 4 Heating capacity (2) kw 26,5 32,2 38,9 39,9 52,6 62,7 73,5 Number of refrigerant circuits - 1 2 Number and type of compressors - 1 SROLL 2 SROLL MA/MN 4 Total input kw 9,00 10,3 13,0 13,5 18,0 21,8 26,1 4 Total input kw 7,00 8,30 9,80 10,4 14,1 17,6 20,7 Sound pressure level (3) ED/N Total input Standard air flow rate (4) Max. working static pressure (5) Sound pressure level (3) ED-V/N-V Total input Standard air flow rate (4) Max. working static pressure (6) Sound pressure level (3) db(a) 69 57 58 62 60 61 62 V/Ph/Hz 400/3/50 kw 0,80 1,10 1,10 1,10 2,20 2,20 3,00 l/s 1417 1889 1889 2120 2660 3100 3620 Pa 240 240 240 300 300 300 300 db(a) 43 47 50 51 52 53 53 V/Ph/Hz 400/3/50 kw 0,75 1,10 1,50 3,00 4,40 4,40 6,00 l/s 1597 1889 2167 2639 3194 3472 3889 Pa 140 170 180 140 115 145 180 db(a) 53 56 58 58 60 62 64 V/Ph/Hz 400/3/50 Data referred to the following conditions: (1) Ambient air at 27 /19,5 W.B.; fresh air 35 (2) Ambient air 20 D.B.; fresh air 7 D.B./6,1 W.B. (3) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. (4) Nominal air flow rate, with standard electric motors, without air filter section (sizes 91 121). (5) Max available static pressure with standard airflow, oversized motors. This value does not take into consideration the air filtering section(sizes 91 121). This value takes into consideration the air filtering section (sizes142 242). (6) Available static pressure with standard flowrate, including air filter. 212

MA/MN 91 242 4 Rubber antivibration mounts 4 Low external air temperature pressureswitch device 4 High and low pressure gauges 4 Supply fan uprated electric motor 4 Phase monitor 4 Air supply plenum MA only: 4 onnection set (thermostat, solenoid valve, dehydrating filter, liquid flow gauge) MN only: 4 ondensate collecting tray with heating element 4 onnection set (thermostat, dehydrating filter, liquid flow gauge, check valve) dimensions and clearances A1 A A2 91 182 B2 B B1 B1 B B2 202 242 A1 A A2 MA/MN 91 101 121 142 182 202 242 Length (A) mm 1517 1780 1780 2230 2230 2230 2230 Width (B) mm 758 846 846 978 978 978 978 Height () mm 1130 1205 1205 1430 1430 1705 1705 mm 500 500 500 500 500 500 500 (A2) mm 400 400 400 400 400 400 400 (B1) (*) mm 70+R 70+R 70+R (**) (B2) mm 500 500 500 500 500 500 500 Weight in oper. kg 336 385 392 594 635 715 720 Notes: (*) R =Return space; (**) leave free. ED/N 91 242 4 Rubber antivibration mounts 4 Hot water coil with 2 rows 4 Hot water coil with 3 rows 4 4,5 kw electric heaters 4 6 kw electric heaters 4 9 kw electric heaters 4 12 kw electric heaters 4 18 kw electric heaters 4 24 kw electric heaters 4 HID-S1 electronic room control 4 Supply fan uprated electric motor 4 Electronic version with control board for HID-S1 thermostats 4 Angular air filter section 4 Mixing and recirculation plenum 4 Supply voltage 230/3/50 4 Supply voltage 400/3/50 without neutral ED only: 4 Solenoid valve for liquid line dimensions and clearances A1 91 121 A A2 B B1 B 142 242 A1 A A2 ED/N 91 101 121 142 182 202 242 Length (A) mm 1285 1435 1435 2010 2010 2510 2510 Width (B) mm 1005 1060 1060 750 750 850 850 Height () mm 585 685 685 630 630 680 680 mm 200 200 200 500 500 500 500 (A2) mm 400 400 400 500 500 500 500 Weight in oper. kg 138 150 158 210 218 280 292 ED-V/N-V 91 242 4 Hot water coil with 2 rows 4 4,5 kw electric heaters 4 6 kw electric heaters 4 9 kw electric heaters 4 12 kw electric heaters 4 18 kw electric heaters dimensions and clearances B B2 A1 A A2 4 24 kw electric heaters 4 HID-S1 electronic room control 4 Supply fan uprated electric motor 4 Front air supply plenum 4 Plenum for air supply on three sides 4 Supply voltage 230/1/50 4 Supply voltage 230/3/50 4 Supply voltage 400/3/50 without neutral ED-V only: 4 Solenoid valve for liquid line ED-V/N-V 91 101 121 142 182 202 242 Length (A) mm 1050 1250 1250 1870 1870 2070 2070 Width (B) mm 670 670 670 670 670 670 670 Height () mm 2000 2000 2000 2000 2000 2000 2000 mm 400 400 400 400 400 400 400 (A2) mm 400 400 400 400 400 400 400 (B1) mm 1000 1000 1000 1000 1000 1000 1000 Weight in oper. kg 185 210 215 250 260 290 295 AUTION! For trouble-free operation of the unit it is essential to maintain the clearances in green. Key to symbols: Accessories supplied separately. 213

MSAT MSAN + ED / ED-V N / N-V 81 242 Split system 4MSAT + ED, ED-V: cooling only 4MSAN + N, N-V: reversible heat pump Air cooled apacity from 21,3 to 73,9 kw ED 81 242 N 81 242 MSAT/MSAN ED-V 91 242 N-V 91 242 The HID-S1 room control design is user-friendly. Setting operations is simple with the large liquid crystal display. Functions: 4 On/Off 4 required temperature setting 4 manual or automatic SUMMER-WINTER setting 4 operation in fan mode only setting 4 manual or automatic FAN SPEED setting (3 speeds) 4 display of outdoor unit status (active compressor) 4 display of alarms 4 modulating signal for 0-10V valves or electric heater control The MSAT + ED + ED-V cooling only or MSAN + N + N-V with heat pump split system is the most versatile offer available today for this type of two-section system. The MSAT (or MSAN) unit is the outdoor part of the system combined with the direct expansion ductable indoor terminal units for horizontal installation in suspended ceiling ED (or N) and for cased, vertical installation ED-V (or N-V). The electronic controls on all the units enable a broader use of the system, allowing integrated control of all devices inserted in the system. The two-circuit condensing units may be connected to two indoor units. functions and features AIR R-407 ooling only Heating-ooling Air cooled Refrig. R-407 Herm. Scroll technical data 81 91 101 121 142 162 182 202 242 4 ooling capacity (1) kw 21,3 24,4 31,2 37,5 38,7 43,4 50,4 62,4 73,9 4 Heating capacity (2) kw 22,4 26,5 32,2 38,9 39,9 44,7 52,6 62,7 73,5 Number of refrigerant circuits - 1 2 Number and type of compressors - 1 SROLL 2 SROLL MSAT/MSAN 4 Total input (3) kw 6,70 8,20 9,80 12,1 13,2 15,3 18,4 21,2 26,1 4 Total input (4) kw 5,12 6,23 7,40 8,90 9,10 10,5 12,7 14,8 17,8 Sound pressure level (5) ED/N Total input Standard air flow rate (6) Max. working static pressure (7) Sound pressure level (5) ED-V/N-V Total input Standard air flow rate (6) Max. working static pressure (8) Sound pressure level (5) db(a) 60 61 60 61 60 60 60 61 62 V/Ph/Hz 400/3/50 +N kw 0,80 0,80 1,10 1,10 1,10 2,20 2,20 2,20 3,00 l/s 1417 1417 1889 1889 2120 2500 2660 3100 3620 Pa 240 240 240 240 300 300 300 300 300 db(a) 42 43 47 50 51 56 52 53 53 V/Ph/Hz 400/3/50 kw - 0,75 1,10 1,50 3,00-4,40 4,40 6,00 l/s - 1597 1889 2167 2639-3194 3472 3889 Pa - 140 170 180 140-115 145 180 db(a) - 53 56 58 58-60 62 64 V/Ph/Hz 400/3/50-400/3/50 214 Data referred to the following conditions: (1) Ambient air at 27/19,5 W.B.; fresh air 35. (2) Ambient air 7 D.B./6 W.B.; fresh air 20 (3) Saturated suction temperature (SST) = 9,5 (Dew Point); external air temperature 35 (4) Air at external exchanger inlet = 6,1 W.B.; condensing temperature = 40 ; (5) Sound levels refer to units with full load under nominal test conditions. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. (6) Nominal air flow rate, with standard electric motors, without air filter section. (7) Max available static pressure with standard airflow, oversized motors. This value does not take into consideration the air filtering section(sizes 91 121). This value takes into consideration the air filtering section (sizes142 242). (8) Available static pressure with standard flowrate, including air filter.

MSAT/MSAN 81 242 4 Rubber antivibration mounts 4 Remote keypad 4 ondenser coil in copper/aluminium with acrylic coating 4 opper/copper condenser coil 4 Serial communication module P/BMS MODBUS for 1 unit (Master) 4 Serial communication module P/BMS MODBUS from 2 to 254 units (Slave) 4 Low external air temperature pressure-switch device 4 oil protection grilles on external air side 4 Phase monitor 4 Supply voltage 230/3/50 MSAT only: 4 Hot gas by pass 4 onnection set (thermostat, solenoid valve, dehydrating filter, liquid flow gauge) MSAN only: 4 onnection set (thermostat, dehydrating filter, liquid flow gauge, check valve) dimensions and clearances B1 B A1 A A2 102 242 A1 A A2 81 121 B1 B B2 MSAT/MSAN 81 91 101 121 142 162 182 202 242 Length (A) mm 1373 1373 1573 1573 1563 1563 1563 2098 2098 Width (B) mm 557 557 557 557 1107 1107 1107 1107 1107 Height () mm 1225 1225 1225 1225 1570 1570 1570 1570 1570 mm 200 200 200 200 1000 1000 1000 1000 1000 (A2) mm 500 500 500 500 1000 1000 1000 1000 1000 (B1) mm 200 200 200 200 900 900 900 900 900 (B2) mm - - - - 900 900 900 900 900 MSAT Weight in oper. kg 164 199 244 254 344 364 444 534 544 MSAN Weight in oper. kg 167 202 247 257 347 367 447 537 547 ED/N 81 242 4 Rubber antivibration mounts 4 Hot water coil with 2 rows 4 Hot water coil with 3 rows 4 4,5 kw electric heaters 4 6 kw electric heaters 4 9 kw electric heaters 4 12 kw electric heaters 4 18 kw electric heaters 4 24 kw electric heaters 4 HID-S1 electronic room control dimensions and clearances 4 Supply fan uprated electric motor 4 Electronic version with control board for HID-S1 thermostats (sizes 81 242) 4 Angular air filter section (sizes 81 242) 4 Mixing and recirculation plenum (sizes 81 121) 4 Supply voltage 230/3/50 4 Supply voltage 400/3/50 without neutral ED only: 4 Solenoid valve for liquid line A1 A A2 B B1 B A1 A A2 91 121 142 242 ED/N 81 91 101 121 142 162 182 202 242 Length (A) mm 1285 1285 1435 1435 2010 2010 2010 2510 2510 Width (B) mm 1005 1005 1090 1090 750 750 750 850 850 Height () mm 585 585 685 685 630 630 630 680 680 mm 400 400 400 400 500 500 500 500 500 (A2) mm 200 200 200 200 500 500 500 500 500 Weight in oper. kg 138 138 150 158 210 210 218 280 292 ED-V/N-V 91 242 4 Hot water coil with 2 rows 4 4,5 kw electric heaters 4 6 kw electric heaters 4 9 kw electric heaters 4 12 kw electric heaters 4 18 kw electric heaters 4 24 kw electric heaters 4 HID-S1 electronic room control 4 Supply fan uprated electric motor 4 Front air supply plenum 4 Plenum for air supply on three sides 4 Supply voltage 230/1/50 4 Supply voltage 230/3/50 4 Supply voltage 400/3/50 without neutral ED-V only: 4 Solenoid valve for liquid line dimensions and clearances AUTION! B B2 A1 A A2 For trouble-free operation of the unit it is essential to maintain the clearances in green. ED-V/N-V 91 101 121 142 182 202 242 Length (A) mm 1050 1250 1250 1870 1870 2070 2070 Width (B) mm 670 670 670 670 670 670 670 Height () mm 2000 2000 2000 2000 2000 2000 2000 mm 400 400 400 400 400 400 400 (A2) mm 400 400 400 400 400 400 400 (B1) mm 1000 1000 1000 1000 1000 1000 1000 Weight in oper. kg 185 210 215 250 260 290 295 Key to symbols: Accessories supplied separately. 215

LOSE ONTROL System LOSE ONTROL System Precise temperature and humidity control solutions in technological applications LOSE ONTROL System is comprised of a series of close air conditioning control units designed for automatic temperature and humidity control, as well as filtration for technological and industrial environments, data processing centres and wherever close control in control and processing rooms is required. Because of their flexibility and footprint, which is usually very small, they are also highly suited to many commercial sector applications. 216

System components series size from to name page lose control air-conditioning unit UP-DX 61 302 LOSEontrol New 218 UP-W 61 242 LOSEontrol New 220 UP-W 61 302 LOSEontrol New 222 217

UP-DX 61 302 lose control air-conditioning unit Direct expansion ondenserless Indoor installation apacity from 20,7 to 99,0 kw LOSEontRoL NEW Available from the 2nd semester 2011 The lose ontrol range UP-DX are direct expansion indoor units to be matched with the remote condensers type E-X. The peculiar sizing of the refrigeration circuit with high sensible power make these units ideal for applications like data centres, telecommunication rooms, control and process rooms. The high reliability and intrinsic safeties are just two of the main features. UP-DX also features: 4High flexibility: the double refrigeration circuit with single compressor is the best for the safety while the tandem compressor in the same circuit is the best for high efficiency at part load. All the other configurable models allow a wide choice and unique integration; 4High technology components: the standard use of the electronic expansion valve and the E electronically commuted fans allow to reach high efficiencies, stable conditions and mainteinance free operation; 4Twin ooling: the possibility to have two independent circuits, one DX and the other with chilled water offers a high safety level or the possibility to use a chilled water source. functions and features R-410A EEV ooling only ondenserless Indoor inst. Vertical inst. Refrig. R-410A Herm. Scroll Direct oupled Fan Electronic Expansion Valve available configurations UP-DX 122 (1) M3 (2) EP (3) - (1) SUPPLY: 4M3 Downward supply 4M5 Upward supply (2) VERSION: 4EP Efficiency Plus (Standard) 4DU Double circuit LOSE ONTROL (3) EXTRA OIL: 4- Not required 4TO Twin ooling (with chilled water extra coil) 218

4 Twin ooling (with chilled water extra coil) 4 Hot gas post-heating coil 4 Hot water post-heating coil 4 Heating electric heaters 4 Immersed electrode humidifier 4 Flood detector 4 Dirty filters alarm 4 Humidity probe 4 High efficiency filters 4 Front air return plenum 4 Plenum for front air supply 4 Supply air temperature probe 4 Height-adjustable supporting frame 300<H<500mm 4 Height-adjustable supporting frame 500<H<800mm 4 Floor stand 4 Kit fresh air 4 Motorised supply air damper 4 Phase monitor 4 RS485 remote communication serial port 4 lock board 4 Solenoid valve for liquid line 4 ondensate drain pump Key to symbols: Accessories supplied separately. technical data 61 81 91 82 102 122 162 182 222 262 302 4 ooling capacity (1) kw 20,7 25,1 28,5 34,5 40,9 47,9 57,4 66,3 77,8 86,1 99,0 Sensible cooling capacity kw 19,9 23,7 26,7 30,9 36,7 45,6 52,1 59,4 71,5 78,9 86,7 SHR - 0,96 0,94 0,94 0,90 0,90 0,95 0,91 0,90 0,92 0,92 0,88 ompressor input kw 4,47 5,63 6,38 7,61 8,95 10,4 12,7 14,7 16,9 18,7 22,5 Number and type of compressors - 1 SROLL 2 SROLL Type of fan - PLUGFAN Air flow rate l/s 1667 1944 2222 2361 2500 3750 4028 4444 5833 6528 6667 V/Ph/Hz 400/3/50 Data referred to the following conditions: PRELIMINARY DATA (1) Ambient air 24 D.B./ 17,1 W.B.; relative humidity 50%; condensing temperature 45 dimensions and functional spaces 61 81 91 82 102 122 162 182 222 262 302 Length (A) mm 1000 1000 1000 1500 1500 2100 2100 2100 2770 2770 2770 Width (B) mm 890 890 890 890 890 890 890 890 890 890 890 Height () mm 1996 1996 1996 1996 1996 1996 1996 1996 1996 1996 1996 mm 500 500 500 500 500 500 500 500 500 500 500 (A2) mm 500 500 500 500 500 500 500 500 500 500 500 (B1) mm 700 700 700 700 700 700 700 700 700 700 700 A1 A A2 B1 B LOSE ONTROL 219

UP-W 61 242 lose control air-conditioning unit Direct expansion With chilled water Indoor installation apacity from 24,2 to 118,4 kw LOSEontRoL NEW Available from the 2nd semester 2011 The lose ontrol range UP-W are chilled water indoor units. The peculiar sizing of the cooling circuit with high sensible power make these units ideal for applications like data centres, telecommunication rooms, control and process rooms. The high reliability and intrinsic safeties are just two of the main features. UP-W also features: 4High flexibility: the double refrigeration circuit with single compressor is the best for the safety while the tandem compressor in the same circuit is the best for high efficiency at part load. All the other configurable models allow a wide choice and unique integration; 4High technology components: the standard use of the E electronically commuted fans allow to reach high efficiencies, stable conditions and mainteinance free operation; 4Dual Water ooling: the possibility to have two independent circuits offers a high safety level or the possibility to use two different chilled water sources. functions and features H 2O ooling only Indoor inst. Vertical inst. Refrig. Water Direct oupled Fan available configurations (1) UP-W 122 M3 (1) SUPPLY: 4M3 Downward supply 4M5 Upward supply (2) VERSION: 4EP Efficiency Plus (Standard) 4DU Double circuit (2) EP (3) - LOSE ONTROL (3) EXTRA OIL: 4- Not required 4DWDual Water ooling (with extra chilled water coil) 220

4 Dual Water ooling (with extra chilled water coil) 4 Hot water re-heating coil 4 Heating electric heaters 4 Immersed electrode humidifier 4 Flood detection sensor 4 Dirty filters alarm 4 Humidity probe 4 High efficiency filters 4 Front air return plenum 4 Plenum for front air supply 4 Supply air temperature probe 4 Height-adjustable supporting frame 300<H<500mm 4 Height-adjustable supporting frame 500<H<800mm 4 Floor stand 4 Kit fresh air 4 Motorised supply air damper 4 Phase monitor 4 RS485 remote communication serial port 4 lock board 4 ondensate drain pump 4 Steel mesh filter on water side 4 Manual shut off valve on the hydraulic connections 4 Motorised shut off valve on the hydraulic connections 4 Temperature probe positioned at the exchanger inlet 4 Balancing valve Key to symbols: Accessories supplied separately. technical data 61 81 91 82 102 122 162 222 242 4 ooling capacity (1) kw 24,2 28,0 34,2 41,1 52,2 63,0 81,6 89,9 118,4 Sensible cooling capacity (1) kw 20,7 24,4 29,2 33,6 40,6 52,1 64,2 75,3 93,8 SHR 0,85 0,87 0,85 0,82 0,78 0,83 0,79 0,84 0,79 Type of fan - PLUGFAN Air flow rate l/s 1667 2083 2222 2361 2500 3750 4028 5556 5972 V/Ph/Hz 400/3/50 Data referred to the following conditions: PRELIMINARY DATA (1) Inlet water 7 and outlet water 12 ; ambient air 24 D.B./17.1 W.B.; relative humidity 50% dimensions and functional spaces 61 81 91 82 102 122 162 222 242 Length (A) mm 1000 1000 1000 1500 1500 2100 2100 2770 2770 Width (B) mm 890 890 890 890 890 890 890 890 890 Height () mm 1996 1996 1996 1996 1996 1996 1996 1996 1996 mm 500 500 500 500 500 500 500 500 500 (A2) mm 500 500 500 500 500 500 500 500 500 (B1) mm 700 700 700 700 700 700 700 700 700 A1 A A2 B1 B LOSE ONTROL 221

UP-W 61 302 lose control air-conditioning unit Direct expansion Water cooled Indoor installation apacity from 21,9 to 104 kw LOSEontRoL NEW Available from the 2nd semester 2011 The lose ontrol range UP-W are direct expansion water cooled indoor units. The peculiar sizing of the refrigeration circuit with high sensible power make these units ideal for applications like data centres, telecommunication rooms, control and process rooms. The high reliability and intrinsic safeties are just two of the main features. UP-W also features: 4High flexibility: the double refrigeration circuit with single compressor is the best for the safety while the tandem compressor in the same circuit is the best for high efficiency at part load. All the other configurable models allow a wide choice and unique integration; 4High technology components: the standard use of the electronic expansion valve and the E electronically commuted fans allow to reach high efficiencies, stable conditions and mainteinance free operation; 4Economy ooling: it has been developed to save energy and reduce the operating costs. The system is based on the possibility to make a clever use of the outdoor air to cool down the room whenever the conditions allow that and reducing the use of the compressors. functions and features H 2 O R-410A EEV F ooling only Water cooled Indoor inst. Vertical inst. Refrig. R-410A Herm. Scroll Direct oupled Fan Electronic Expansion Free-ooling Valve available configurations UP-W 122 (1) M3 (2) EP (3) - (1) SUPPLY: 4M3 Downward supply 4M5 Upward supply (2) VERSION: 4EP Efficiency Plus (Standard) 4DU Double circuit LOSE ONTROL (3) EXTRA FREE-OOLING OIL: 4- Not required 4E Economy ooling (with extra water coil) 222

4 Economy cooling (with extra water coil) 4 Hot gas post-heating coil 4 Hot water post-heating coil 4 Heating electric heaters 4 Immersed electrode humidifier 4 Flood detector 4 Dirty filters alarm 4 Humidity probe 4 High efficiency filters 4 Front air return plenum 4 Plenum for front air supply 4 Supply air temperature probe 4 Height-adjustable supporting frame 300<H<500mm 4 Height-adjustable supporting frame 500<H<800mm 4 Floor stand 4 Kit fresh air 4 Motorised supply air damper 4 Phase monitor 4 RS485 remote communication serial port 4 lock board 4 Solenoid valve for liquid line 4 ondensate drain pump Key to symbols: Accessories supplied separately. technical data 61 81 91 82 102 122 162 182 222 262 302 4 ooling capacity (1) kw 21,9 26,3 29,7 36,5 43,2 50,4 60,2 69,6 81,5 90,9 104,0 Sensible cooling capacity kw 20,5 24,3 27,4 32,4 38,6 46,7 53,9 61,0 73,6 81,6 89,2 SHR - 0,93 0,92 0,92 0,89 0,89 0,93 0,89 0,88 0,90 0,90 0,86 ompressor input kw 3,95 5,03 5,79 6,62 7,88 9,25 11,6 13,0 15,3 16,7 20,0 Number and type of compressors - 1 SROLL 2 SROLL Type of fan - PLUGFAN Air flow rate l/s 1667 1944 2222 2361 2500 3750 4028 4444 5833 6528 6667 V/Ph/Hz 400/3/50 Data referred to the following conditions: PRELIMINARY DATA (1) Ambient air 24 D.B./17.1 W.B.; relative humidity 50%; external heat exchanger water = 30/35 dimensions and functional spaces 61 81 91 82 102 122 162 182 222 262 302 Length (A) mm 1000 1000 1000 1500 1500 2100 2100 2100 2770 2770 2770 Width (B) mm 890 890 890 890 890 890 890 890 890 890 890 Height () mm 1996 1996 1996 1996 1996 1996 1996 1996 1996 1996 1996 mm 500 500 500 500 500 500 500 500 500 500 500 (A2) mm 500 500 500 500 500 500 500 500 500 500 500 (B1) mm 700 700 700 700 700 700 700 700 700 700 700 A1 A A2 B1 B LOSE ONTROL 223