Work In Shirt-Sleeve Comfort When It s Doggone Cold

Similar documents
Gas-Fired Unit Heaters Commercial & Industrial

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

SUBMITTAL SCHEDULE & DATA

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

bring value to your space

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

True performance and rugged durability. TU, LF and LD Models

U n i t H e at e r s

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

GARAGE / WORKSHOP INFRARED HEATERS

AUGUST, High-Efficiency Condensing Gas-Fired Separated Combustion Unit Heaters

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.

Gas-Fired Unit Heaters Commercial & Industrial

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

COMFORT CONTROL 90 PLUS WITH DUAL TWO-STAGE UPFLOW GAS FURNACES

HVAC HEATING PRODUCTS

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New

Click Here To View Item at

COMMERCIAL & INDUSTRIAL UNITARY HEATING PRODUCTS GAS STEAM/HOT WATER OIL ELECTRIC

CATALOG: HVAC - Gas Space Unit Heating

GAS FURNACES CLASSIC 95% A.F.U.E. HIGH EFFICIENCY UPFLOW GAS FURNACES

Ruud Acheiver Series Upflow Gas Furnaces

GAS FURNACES. RGRK- SERIES Models with Input Rates 120,000 BTU/HR [35.17 kw] (All Models 90% A.F.U.E. or Above)

Indirect Gas-Fired Make-Up Air

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

Rheem Classic Series Downflow/ Horizontal Gas Furnaces

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Catalog Gas Heating Products: Indoor and Outdoor Units

LADERA. Traditional. Fireplace Design Collection EPA WOOD BURNING FIREPLACES

Gas-Fired Indoor and Outdoor Duct Furnaces

and Digital Thermostats

Gas-Fired Indoor and Outdoor Duct Furnaces

May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

GAS FURNACES SELECT 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

Heating Products M arch 2012

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY UPFLOW GAS FURNACES

GAS FURNACES 90 PLUS WITH DUAL COMFORT CONTROL TWO-STAGE UPFLOW GAS FURNACES

90TJ SERIES Models with Input Rates from 45,000 to 120,000 BTU/HR [13.19 to kw] (All Models 90% A.F.U.E. or Above)

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

90 HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

GAS FURNACES CLASSIC 90 PLUS HIGH EFFICIENCY DOWNFLOW/ HORIZONTAL GAS FURNACES

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

MONTECITO. Traditional. Fireplace Design Collection EPA WOOD BURNING FIREPLACES

Cooling Capacity CFM range

80% and 95% furnace models feature aluminized steel heat exchangers to conduct heat quickly and increase durability.

G6RC Series TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE MODELS: P*UR GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW FURNACES 92 AFUE DESCRIPTION WARRANTY FEATURES Rev.

Cabinet Unit Heaters Steam / Hot Water

Cooling Capacity CFM in. w.c. (125 Pa)

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

SHP High Pressure Radiant Gas Brooder Series

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

INFRARED RADIANT HEATERS

GreenJet Transfer Fans

Ruud Achiever Series Multi position Gas Furnaces

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

VILLA VISTA. Traditional. Fireplace Design Collection EPA WOOD BURNING FIREPLACES

Product Data. 58CLA Low-Boy Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

95% SERIES 2 HEAT ONLY AND COMBINATION GAS WALL MOUNT BOILERS. Bringing. heat and hot water into perfect Balance

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

P-200T / P-200AT / P-230AT (115V / 60Hz)

Comfort, Quality and Efficiency.

RED DOT UNITS HEATER ONLY. Heaters PAGE 51

Product Specifications. Vertical Floor Consoles By First Co.

Product Data. 58CMA Multipoise Oil Furnace. Series 120 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Gas-Fired Heating Equipment

Product Data. 58CMA Multipoise Oil Furnace. Series 110 Input Capacities: 70,000 thru 154,000 Btuh. The Latest in Oil Furnace Technology

Cooling Capacity CFM in. w.c. (125 Pa)

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

MULTI POSITION GAS FURNACE

HVAC. Air Blowers Fans Forced Air Heaters Heating Cables & Insulation Infrared & Radiant Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Leisure Line Stoves are to be used as supplemental heat only. Do not use this stove as a replacement for a furnace.

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series

iq251, Gen II Submittal Data

13 GEP A L P - 1 A

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

Transcription:

Work In Shirt-Sleeve Comfort When It s Doggone Cold

Bring Heat To Your Pet Projects Low-Profile, Gas-Fired Residential Garage Heaters.

Pamper your pride and joy in warmth and comfort. Hot Dawg Chasing Away The Cold In Any Space, New Or Old It s no problem to race from cold to comfort. Set the thermostat and get set for comfort. Handle winter woodworking with warm hands. Year-round growing without going through a lot of greenbacks. Installs quickly and easily (only 1" from the ceiling) in any garage or out building. Loading or unloading is easier when it s always warm.

Hot Dawg Leading The Pack In Compact Unit-Heater Versatility, Performance And Value

Hot Dawg Model HD power-exhausted, gas-fired unit heater Hush-puppy quiet operation. Uses natural or propane gas. Certified for residential, commercial and industrial use. Low-profile design and neutral color to blend in with decor. Lightweight, easily installs 1" from ceiling with only 2 angle brackets (included). Install quickly and easily with field wiring connections and knockouts for quick access to gas and electricity. Standard power exhaust simplifies side-wall or roof venting with small-diameter vent pipe. Versatile design allows for right or left hand controls and installation. Gas, electrical and flue connections can be changed from one side to the other by simply flipping the Hot Dawg over. Permanently-lubricated motor for trouble-free dependability. Full 10-year warranty on heat exchanger. Also available with a blower. Contact Modine for further information. Hot Dawg Model HDS separated-combustion, gas-fired unit heater The separated combustion Hot Dawg draws its combustion air from outside the work space, ensuring the unit always has plenty of fresh, clean air to breathe. This fresh-air supply reduces common concerns about dusty, dirty or humid applications. Additionally, drawing combustion air from the outside increases overall heating efficiency. In short, a separated combustion Hot Dawg unit gives you many added advantages, including: Less maintenance in dusty environments, Improved efficiency by using outside air for combustion, Greater durability in hostile environments (environments possessing substances that may deteriorate the performance of the unit), External thermostat and gas connections. For The Heat You Need, Just Unleash A Hot Dawg! Unit Btu/Hr Input Typical Application HD/HDS 30 30,000 1 to 1-1/2 Car Garage HD/HDS 45 45,000 2 to 2-1/2 Car Garage HD/HDS 60 60,000 3 to 3-1/2 Car Garage HD/HDS 75,100,125 75,000-125,000 Large Garage Sizing data for sample only. Consult a qualified installer for the actual requirements for your building.

Power-Exhausted, Gas-Fired Unit Heater Specifications Performance Models Btu/Hr Input Btu/Hr Output Entering Airflow (CFM) Outlet Velocity Air Temp. Rise ( F) Mounting Height (Max ft.) Heat Throw (ft.) Horsepower Motor RPM Data Type Amps Unit Total Amps Vent Connector Size (in.) HD30 HD45 HD60 HD75 HD100 HD125 30,000 45,000 60,000 75,000 100,000 125,000 24,000 36,000 48,000 60,000 80,000 100,000 505 720 990 1,160 1,490 1,980 523 749 653 769 565 747 44 46 45 48 50 47 10 10 12 14 12 16 25 27 36 38 42 56 1/15 1/15 1/12 1/12 1/12 1/8 1,550 1,550 1,625 1,625 1,050 1,550 S.P. S.P. P.S.C. P.S.C. S.P. P.S.C. 2.4 2.4 1.2 1.2 2.7 2.2 3.7 3.7 2.5 2.5 4.7 4.2 3 3 3 3 4 4 Dimensions (inches) Models HD30 HD45 HD60 HD75 HD100/125 A 26.8 26.8 26.8 26.8 35.5 B 12.2 12.2 18.0 18.0 20.5 C 16.5 16.5 16.5 16.5 22.0 D 14.9 14.9 14.9 14.9 22.5 E 10.1 10.1 15.9 15.9 18.4 F 7.5 7.5 10.7 10.7 14.0 G 18.5 18.5 18.5 18.5 24.0 H 7.6 7.6 7.8 7.8 8.4 Gas Connection 1/2 1/2 1/2 1/2 1/2 I 34.5 34.5 34.5 34.5 43.0 J 22 22 25 25 31.0 Fan Diameter 10 10 14 14 18.0 Approx. Shipping Weight (lbs.) 55 60 80 85 125 Mounting Clearances 1 - angle, mounting brackets are slotted to accommodate joists on 16 or 24 centerlines. Unit Side Clearance To Combustible Materials Recommended Service Clearance Top and Bottom 1" 1".00 1.10 3.10 5.10 7.10 9.10 HD30-75 17.10 19.10 21.10 23.10 25.10 26.20 Access Side 18" 18" Non-Access Side 1" 1" Rear 18" 18" Vent Connector 4" 4" HD100/125.00 1.50 3.50 5.50 7.50 9.50 11.50 13.50 21.50 23.50 25.50 27.50 29.50 31.50 33.50 35.00 Control Options Control Description Control Service Thermostat Type of Model Code No. Voltage Voltage Gas Size Single-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 11 115V 24V natural 30-125 - Utilizes a single-stage combination gas control with ignition control. Gas is lit with a direct spark igniter on call for heat. 21 115V 24V propane 30-125 Two-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 12 115V 24V natural 75-125 - Utilizes a two-stage combination gas control with built-in ignition control. Firing rate is 100% and 50% of full rated input. Gas is lit with a direct spark 22 115V 24V propane 75-125 igniter on call for heat.

Separated-Combustion, Gas-Fired Unit Heater Specifications Performance Models Btu/Hr Input Btu/Hr Output Entering Airflow (CFM) Outlet Velocity Air Temp. Rise ( F) Mounting Height (Max ft.) Heat Throw (ft.) Horsepower Motor RPM Data Type Amps Unit Total Amps Vent Connector Size (in.) Mounting HDS30 HDS45 HDS60 HDS75 HDS100 HDS125 30,000 45,000 60,000 75,000 100,000 125,000 24,000 36,000 48,000 60,000 80,000 100,000 505 720 990 1,160 1,490 1,980 523 749 653 769 565 747 44 46 45 48 50 47 10 10 12 14 12 16 25 27 36 38 42 56 1/15 1/15 1/12 1/12 1/12 1/8 1,550 1,550 1,625 1,625 1,050 1,550 S.P. S.P. P.S.C. P.S.C. S.P. P.S.C. 2.4 2.4 1.2 1.2 2.7 2.2 3.7 3.7 2.5 2.5 4.7 4.2 3 3 4 4 4 4 Dimensions (inches) Models A B C D E F G H Gas Connection I J K L Fan Diameter Approx. Shipping Weight (lbs.) HDS30 HDS45 HDS60 HDS75 HDS100/125 26.8 26.8 26.8 26.8 35.5 12.2 12.2 18.0 18.0 20.5 16.5 16.5 16.5 16.5 22.0 14.9 14.9 14.9 14.9 22.5 10.1 10.1 15.9 15.9 18.4 7.25 7.25 10.75 10.75 14.0 18.5 18.5 18.5 18.5 24.0 7.6 7.6 7.835 7.835 8.4 1/2 1/2 1/2 1/2 1/2 34.5 34.5 34.5 34.5 43.0 22 22 25 25 31.0 2.74 2.74 3.15 3.15 3.87 3.19 3.19 5.55 5.55 10.73 10 10 14 14 18.0 55 60 80 85 125 1 - angle, mounting brackets are slotted to accommodate joists on 16 or 24 centerlines. Clearances.00 1.10 3.10 5.10 7.10 9.10 HD30-75 17.10 19.10 21.10 23.10 25.10 26.20 Unit Side Clearance To Combustible Materials Recommended Service Clearance Top and Bottom 1" 1" Access Side 1" 18" Non-Access Side 1" 1".00 1.50 3.50 5.50 7.50 9.50 11.50 13.50 HD100/125 21.50 23.50 25.50 27.50 29.50 31.50 33.50 35.00 Rear 18" 18" Vent Connector 4" 4" Control Options Control Description Control Service Thermostat Type of Model Code No. Voltage Voltage Gas Size Single-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 11 115V 24V natural 30-125 - Utilizes a single-stage combination gas control with ignition control. Gas is lit with a direct spark igniter on call for heat. 21 115V 24V propane 30-125 Two-Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 12 115V 24V natural 75-125 - Utilizes a two-stage combination gas control with built-in ignition control. Firing rate is 100% and 50% of full rated input. Gas is lit with a direct spark 22 115V 24V propane 75-125 igniter on call for heat.

You don t have to go far to find a Hot Dawg. For the location of your nearest Hot Dawg source, fetch your phone and call: 800-700-7324 or visit us online at www.modine.com/hotdawg Low-Profile, Gas-Fired Residential Garage Heaters Commercial Products Group Modine Manufacturing Company 1500 DeKoven Avenue Racine, WI 53403-2552 Phone: 1.800.828.4328 (HEAT) Fax: 262.636.1665 www.modine.com/hotdawg Modine Manufacturing Company, 2007 Hot Dawg and the Hot Dawg logo are registered trademarks of Modine Manufacturing Company. 6-114.4