Energy Consumption and User Comfort In Cold Climate NZEHs

Similar documents
Modular Construction. Live/Work Urban Infill Townhome. Modular Construction. Enclosure Design. San Francisco Bay Area Net Zero Urban Infill

Student Dorms as Passive Houses

Julie Klump, POAH Rick Fenuccio, Tom Hartman Marc Rosenbaum Melpet preliminary heat loss and energy model results and implications

nzeb office building

The Ad-Hoc Passive House. Paul W Panish

Better Buildings By Design What are the best HVAC solutions for low-load, high performance homes? February 6-7, 2013

Performance of Solar Water Heating Systems in the United States

HEAT LOAD AND SOLAR GAIN PREDICTION FOR SOLID WALL DWELLINGS RETROFITTED WITH TRIPLE VACUUM GLAZING FOR SELECTED WINDOW TO WALL AREA RATIOS

Performance of Heat Recovery Ventilation System with Ground Source Brine Heat Exchanger Pre- Heating System in the Context of nzeb

RECOMMENDATIONS FOR 15% ABOVE-CODE ENERGY EFFICIENCY MEASURES FOR RESIDENTIAL BUILDINGS

Passivhaus. sally godber MEng CEng MIMechE WARM: Low Energy Building Practice. The first 3 in the UK.

A highly efficient Enclosure is Key. The Building is always the sum of ALL it s parts

New Steps towards Compact Solar Combisystems in Scandinavia

Daikin Altherma Selection Report

Fixing the Pretty Good House. Marc Rosenbaum, P.E. South Mountain Company West Tisbury, MA

Impacts of Optimized Cold & Hot Deck Reset Schedules on Dual Duct VAV Systems - Theory and Model Simulation

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

Cork County Energy Agency

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

DISTRICT HEATING SCHEME FEASIBILITY STUDY FRANKTON FLATS QUEENSTOWN

High Performance or Hype Performance? Marc Rosenbaum, Some Real World Data. Marc Rosenbaum, P.E. South Mountain Company West Tisbury, MA

Riverdale NetZero Project Summary of Costs and Expected Performance

SOLAR THERMAL HEATING: ALIVE AND WELL

Energy Options for Residential Heating. Juergen Korn, P.Eng.

LESSONS LEARNED FROM THE PASSIVE HOUSE IN THE WOODS

Multifamily Buildings: Real World Monitored Data on Hot Water Energy and Water Use

RESULTS FROM HOUSE APPLIANCE SAFETY AND DEPRESSURIZATION TESTS CONDUCTED ON SINGLE FAMILY HOUSES UNDERGOING SOUND INSULATION

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

Copyright 2003 IBACOS, Inc. All rights reserved.

Room-temperature (economy/night) unit TR 212 E

Net-zero and Near Net-zero Homes in Jefferson County

Air and operative temperature measurements in a plus-energy house under different heating strategies

MEASURED PERFORMANCE DATA FOR

Calculated Energy Savings for Disabling Anti- Sweat Door Heat on Glass Display Case Doors

the STABLES Passive House Certifi cation Pending 3 bedrooms + offi ce / 4th bedroom 3 full bathrooms /- sq ft of living space

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Minnesota Multifamily Rental Characterization Study

VARIABLE HEAT RECOVERY IN DOUBLE BUNDLE ELECTRIC CHILLERS. Richard J Liesen 1, Rahul J Chillar 2 1 University of Illinois at Urbana Champaign

Design and Operation of a Conditioning Energy Recovery Ventilator (CERV) for Passive Houses

Continuous Commissioning: A Valuable Partner to Retrofit Projects

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

Larch house and Lime house review of systems design and implementation

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

RESNET Rating Field Inspector Field Evaluation Form

Systems engineering Slide 1

IES Whole-Building Energy Model Baseline Energy Model Input/ Output Report. East Liberty Presbyterian Church East Liberty Presbyterian Church

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. What is condensation?

Energy Efficiency Standards

Dynamic Thermal Simulation & Systems Sizing Report

Displacement Ventilation in Classrooms

2 Safety valve. 3 Pressure gauge. 4 Thermometer. 8 Ball valves

BSC Building America High Performance Homes: Today & Tomorrow. Peter Yost Senior Building Scientist

PROTECTING FIRE SPRINKLER SYSTEM PIPES FROM FREEZING IN CHAPTER FACILITIES

ENERGY SYSTEMS LABORATORY

SIMULATION STUDY ON A NET-ZERO ENERGY HOUSE WITH SOLAR AIR COLLECTORS

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

How to Heat Water in All-Electric Homes & Apartments?

RdSAP Conventions for SAP 2009

ENERGY CONSUMPTION OF HOUSES AND LIFESTYLE IN COLD CLIMATIC AREA OF JAPAN

Retrofitting a Multi-Unit Residential Building To Reduce Purchased Energy by a Factor of 10. Chris Richards

Hot Water Generation for Commercial and Industrial Applications. Paul Marsden Specification Sales Manager

Practical and Effective Approaches to Residential Ventilation for Production Builders

Villa Bagatelle Technical Report

Index. Premises Information 2 About This Log Book 3 Service and Maintenance Requirements 4 8. Fire Risk Assessments 9

Sivu 2/8 Rate data Description Suomi Shut off times total 0.0 h/day Weekends with shut off times yes Daytime rate of heat pump Time for daytime rate 5

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Measurement of Attic Temperatures and Cooling Energy Use in Vented and Sealed Attics in Las Vegas, Nevada

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Matt Cooper, PE, BEMP, HBDP, Group 14 Engineering Ken Urbanek, PE, HBDP MKK Consulting Engineers, Inc.

Fifteen Years of Dehumidification Results from Heat Pump Water Heaters

TECHNICAL NOTE JULY Dr. Thomas Butcher Brookhaven National Laboratory Building 526, P.O. Box 5000 Upton, L. I. NY 11719

Appendix C House models for Dymola to be used in connection with the OPSYS test rig and annual simulations of the performance of heat pumps

USING INFRARED TECHNOLOGY TO DEFINE ENERGY SAVINGS OPPORTUNITIES. James L. Park Energy Conservation Specialist I-Star Energy Solutions

Distribution systems in apartment buildings

System Using Exhaust Heat from Residential GHPs

Laboratory Evaluation of Hybrid and Advanced Water Heaters: Performance Overview in Hot Humid Climate

MAINTAINING A HEALTHY, COMFORTABLE, INDOOR ENVIRONMENT

Energy Efficiency Rating

RESEARCH HIGHLIGHT. Arviat E/2 Northern Sustainable House Energy Consumption Performance Assessment

FR 10 INSTALLATION & USER INSTRUCTIONS INTELLIGENT ROOM THERMOSTAT

7. MECHANICAL SYSTEM DESIGN

HUMIDITY CONTROL IN A BASEMENT ART VAULT

Zero Energy Home. Team 4 Nittany Designs Edesign100 Section 15 Submitted to: Professor Wallace Catanach 2/22/13 Team Members

The Corbioli House is a single-family house situated

POTENTIAL ENERGY SAVINGS WITH EXTERIOR SHADES IN LARGE OFFICE BUILDINGS AND THE IMPACT OF DISCOMFORT GLARE. Sabine Hoffmann, Eleanor Lee

Lifestyle Electric Thermal Radiator

Lifestyle Electric Thermal Radiator

Energy Performance Certificate

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

Thermal Environment in a Space with Capillary Mats Large-Area Cooling and Heating

Heat Consumption Assessment of the Domestic Hot Water Systems in the Apartment Buildings

Keep your electricity bill cool this summer

BEST PRACTICE RECOMMENDATIONS

Produced by the Residential Solution Sales Division. Daikin AC Americas, Inc.

Power-to-Cold using vacuum ice slurry technology in the scope of German WindNODE project

Heating System Missing vent (retapped. Steam System Repair

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

A 92 plus B C D E F 21-38

Transcription:

Energy Consumption and User Comfort In Cold Climate NZEHs Peter Engelmann, PhD; Kurt Roth, PhD ASHRAE Annual Conference, June 28 th 2011 Fraunhofer USA

Agenda monitoring - background introduction of monitored buildings energy consumption and indoor comfort in summer energy consumption and indoor comfort in winter conclusion outlook

background monitoring principles and challenges on site delivery conversion storage distribution end use Fuel Heat Chill Power Irradiation aux. energy loss loss aux. energy loss aux. energy loss decreasing availability of measured data decreacing accuracy of calculated data

background the net-zero balance renewable sources efficiency measures house built to code key questions: what is necessary to achieve a net-zero energy balance in cold climates? how big is the user influence on a zero balance how is the indoor comfort in heating and cooling season?

the buildings Stow, MA floor area (conditioned ANSI Z765-2003), floors: 4 2964 ft 2 275 m 2 building envelope R [ft 2 F h/btu] U [W/m 2 K] insulation exterior walls to ambient R65 0.09 insulation exterior walls to ground R25 0.23 insulation roof R63 0.09 windows (triple glazed) R5.1 1.11 calculated demand for space heating 12 kbtu/ft 2 yr 37.8 kwh/m 2 yr ventilation HRV, HRV 60% PV generator 6.3 kw p HERS index 9

the buildings Townsend, MA floor Area (conditioned ANSI Z765-2003), floors: 2 1835 ft 2 170 m 2 building envelope R [ft 2 F h/btu] U [W/m 2 K] insulation exterior walls to ambient R47 0.12 insulation exterior walls to ground R24 0.23 insulation roof R63 0.09 windows (double pane) R4.8 1.2 calculated demand for space heating 19.2 kbtu/ft 2 yr 60.8 kwh/m 2 yr ventilation HRV, HRV 60% PV generator 7.14 kw p HERS index 2

the buildings - location

ambient conditions and instrumentation Location: 42 N, 71 W instrumentation: multi-channel power meter, each breaker-circuit is measured temporary decentral temperature, relative humidity and CO 2 loggers Ambient temperature and humidity are measured on site. heating period: HDD 65 (10/2010 04/2011) 3,314 ( C) 5,965 ( F) ASHRAE 90.1 for Boston: 5,641

energy balance net zero goal achieved? NZH in Stow end energy consumption electric energy for space heating (Oct Mar): 14.1 kwh/m²yr, 4.4 kbtu/ft²yr energy consumption for space heating is dominating load DHW is hidden in different circuits (direct resistance heater, heat pump plugged in basement and laundry outlet) energy consumption excluding heating/cooling/dhw/fridge is approx. 3500kWh, national average (Northeast): 6793 kwh (source: DOE, Buildings Energy Data Book 2010)

energy balance net zero goal achieved? NZH in Townsend end energy consumption electric energy for space heating (Oct Mar): 12.6 kwh/m²yr, 4.0 kbtu/ft²yr seperate outdoor units for ductless splits but mainly only one unit is used HRV is manually switched on and off by users hill/trees south-west of the building shade PV during winter DHW by gas boiler, consumption Oct 2010 May 2011 870 kwh

energy and comfort summer NZH in Stow daily and weekly pattern In summer, the energy consumption is rather dominated by DHW. Base load of 300-400 W during night. PV generation doubles the power consumption. circuit average kwh/d minisplit 3.8 DHW 3.7 fridge 1.4 basement 1.4 HRV 1.0 misc. 3.6 total 14.8

energy and comfort summer NZH in Stow indoor thermal comfort Temperature and humidity are in the limits defined in ASHRAE 55 most of the time. If not, it s rather too humid than too warm. No destinctive temperature stratification over the 3 stories.

energy and comfort summer NZH in Stow indoor thermal comfort Temperature and humidity are in the limits defined in ASHRAE 55 most of the time. If not, it s rather too humid than too warm. No destinctive temperature stratification over the 3 stories. AC is mostly used, when temperatures don t drop under 20 C (68 F) over night.

energy and comfort summer NZH in Stow indoor air quality living room ASHARE 62.1 limits (CO 2 700ppm over outdoor conditions) exceeded significantly, especially in the master bedroom. Reason is fault in ventilation unit. master bedroom

energy and comfort winter malfunction in ventilation unit controls Damper that seals fresh air inlet and opens bypass to re-circulate the air was constantly in frost protection mode. error is remedied but internal leakages are likely.

energy and comfort winter NZH in Stow daily and weekly pattern Average load pattern during heating season (Dec 2010, Jan, Feb 2011). Space heating is dominating load. During winter time PV covers only a third of the energy consumption. circuit average kwh/d minisplit 30.3 basement outlet 4.6 smoke det. 1.5 HRV 1.3 fridge 1.2 misc. 4.5 total 43.4

energy and comfort winter NZH in Stow daily and weekly pattern Average load pattern during heating season (Dec 2010, Jan, Feb 2011). [W] Water heating is switched to a heat pump, which was plugged in the basement outlets circuit, controlled by a timer.

energy and comfort winter ASHRAE 55 - NZH in Stow living room Measurement period: 01/25 04/10/2011 master bedroom Indoor thermal comfort most of the time within good comfort conditions (assuming clothing rate clo 1.0)

energy and comfort winter Stow Indoor temperature very stable. Fluctuations typically not more than 2K over a day

energy and comfort winter Stow Indoor temperature very stable. Fluctuations typically not more than 2K over a day

energy and comfort winter NZH in Stow living room CO 2 concentration unusual high master bedroom But during the measurement most of the time untypical high occupation density (8 people present): far beyond the design parameters of the ventilation system. Internal leakages in the ventilation system likely (but not quantified).

energy and comfort winter NZH in Townsend daily and weekly pattern Average load pattern during heating season (Dec 2010, Jan, Feb 2011). Water heating is not included. Space heating by far biggest load. Over a three months period, the fridge has a higher average load than any other appliance. circuit average kwh/d minisplit 1 st floor 22.7 fridge 1.8 living room 1.0 master bedroom 1.0 minisplit 2 nd floor 0.8 misc. 2.9 total 30.2

energy and comfort winter NZH in Townsend daily and weekly pattern Example for one day: Monday, 01/24/2011: day with the highest energy consumption in the living room circuit. Average ambient temperature: -17.1 C (1.3 F) circuit average kwh/d minisplit 1 st floor 22.7 fridge 1.8 living room 1.0 master bedroom 1.0 minisplit 2 nd floor 0.8 misc. 2.9 total 30.2

energy and comfort winter ASHRAE 55 - NZH in Townsend living room The measured values for temperature are outside of comfortable conditions (assuming a clothing rate of 1.0). master bedroom

energy and comfort winter ASHRAE 55 - NZH in Townsend The measured values for temperature are outside of comfortable conditions (assuming a clothing rate of clo 1.0). master bedroom Nevertheless occupants accept lower temperatures (space heating system is not at its limit).

energy and comfort winter Townsend Indoor temperature is significant lower than in Stow, but stable. Influence of space heating (and occupants) is obvious at 6:00PM and partly at 6:00AM.

energy and comfort winter NZH in Townsend living room master bedroom CO 2 concentration in the living room is acceptable even with manually switched mechanical ventilation. In the bedroom concentrations are too high. After switching the HRV to 24/7 operation, CO 2 levels are significantly reduced.

energy and comfort winter comparison of ductless split loads Stow Correlation of ambient temperatures and loads from the ductless split (hourly mean values) systems show a more reasonable temperature heat-loss correlation in Stow. Coldest Days are not the days with the highest loads. Townsend In Townsend the available power seems to be limited because the second unit (on the second floor) is hardly used.

conclusions - oulook Energy for space heating remains dominating load, followed by DHW. In a good insulated envelope single point heat source can be used without comfort problems. NZEHs are likely occupied by aware users Mechanical ventilation is crucial in airtight buildings, but available solutions need improvements. Standby losses can sum up to a significant energy consumption.

thank you! www.cse.fraunhofer.org Peter Engelmann pengelmann@fraunhofer.org Kurt Roth kroth@fraunhofer.org Acknowledgements: Carter Scott, Transformations Inc., Townsend, MA 01469 www.transformations-inc.com