Long Life AC Axial Flow Fans MRE Series

Similar documents
MDA Series. DC Axial Flow Fans with Low-Speed Alarm. $$ The Low-Speed Alarm: "Features

Cooling Fans ver ver.4

Orientalmotor Thermal Management

TEMPORARY SPECIFICATION FOR REFERENCE

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL. Customer Description Part No.. Model No. JDD VBBA51(0A24) Sample Issue No. Sample Issue Date

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)

CR 027 PTC Fan Heater W

Cooling Module. Cooling Fans. Cooling Fans F-105. FM Series IP55/43. Introduction MRS. Variable Flow MRS

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

STANDARD. Customer : DC FAN. Description : Customer P/N : rev. : N/A X01. Sample issue date : DEC Quantity :

Product Data Sheet 4114 N/17HH-218. The engineer's choice

(P) AD0612VB-A7BGP P.S. REV. DC FAN (RoHS)

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Enclosure Heaters and Fan Heaters

Revised Record 研發處發行章 Rev. Revision Description Change page Date A00 Preliminary

研發處 研發處 研發處 研發處 簡文榮 林茂盛 AD0612LB-A73GL P.S. REV. DC FAN (RoHS) 研發處

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

Ordering Key. Dielectric strength

SHIMADEN DIGITAL INDICATORS

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD1212PTS1-6A

Thermal Management Products & Accessories for Enclosures

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

SPECIFICATION FOR APPROVAL

Cooling Fans H-53. Cooling Fans H-53. Enclosure Fan Modules. Overview. Axial Flow Fans AC Input Low-Power Consumption EMU. AC Input.

Datasheet: K-22 LO Sensor

UL TEST REPORT AND PROCEDURE

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Small diffuse reflective and convergent reflective type BYD50-DDT BYD50-DDT-U 1 BYD100-DDT BYD3M-TDT BYD3M-TDT-P

Class 1 laser beam sensor safe for your eyes

DETECTION AREA OA-FLEX AIR T. Active Infrared Sensor FLEX EYE A X B C D E F G. Emitting area

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

SPECIFICATION FOR APPROVAL

Operating instructions

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Communications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

the next generation thermometer from the global leader

PANTHER. Condensate removal pump Installation and operating guide

Digital Panel Meter K3TL. Ordering Information. Low-cost, High-quality Digital Thermometer with Built-in Microcomputer. Accessories (Order Separately)

Communications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)

Class 1 laser beam sensor safe for your eyes

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

Plug-in Base, Long Range Sensor E3B2

SUNON SPECIFICATION FOR APPROVAL. ISSUE DATE Apple 12/28 REVISION DATE

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

USER GUIDE. RLH Auxiliary Fan Kit. Description. The leader in rugged fiber optic technology. ENCLOSURE TEMPERATURE CONTROL. RLH Industries, Inc.

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

PolyGard 2-channel Gas Controller MGC-03

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

The next generation thermometer from the global leader

Utility. Improved functionality and ease-of-use for bias testing. The chamber interior is formed for easier specimen loading

CII FCAC-150 Series Relay

Class 1 laser beam sensor safe for your eyes

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

AUR300C. Advanced Ultraviolet Burner Controller

JUL 18 Rev A1

Axial flow fan AXICO ANTI-STALL

Model Number Structure

FF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

Control Panel Basics Volume 1

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

EN , EN , DALI 102/207, SELV Output, KS C 7655 Safety Certification Approved RoHS Compliant. Dim. Method

High Output Vacuum/Pressure Pump

Ultrasonic Proximity Sensor

Selectable 2sec., 7sec., 15sec. (selectable by holding time setting switch)

General Specifications

Modular Supply Make-Up Air Unit

ACCUBLOC high performance Heat Recovery

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

MAC-120HE-03 Air-Cooled Chiller

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Original instructions Sense7-series Non-contact coded safety switch

UV Flame Supervision System

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

Assembly. Host Sub-D Alarm

Dimension drawing. Main feature. Dimension (H x W x D) Cooling capacity *Note. Standalone temperature control. Rated voltage.

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

KUH. Horizontal Unit Heater. Applications. Description

AlarmLine Linear Heat Detector

Operation Manual. (Version 1.5.1)

VA G 052 S

Ultrasonic Reflective Sensor

SAX. Window & Wall Fans

UL TEST REPORT AND PROCEDURE

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Transcription:

Long Life AC Axial Flow Fans MRE Series The MRE Series long-life fans have an expected life of 1, hours and are available with a low speed alarm. All MRE Series fans include all components for easy installation. Features $$ The Expected Life of 1 Hours These axial flow fans have an expected life of 1 hours (about years). They reduce the increase in bearing temperature, inhibit grease deterioration and improve vibration resistance and shock resistance through bearing enlargement. They also increase the life of circuits and couplers and reduce failure rate. They are designed based on the concept of initial failure so that random failure and wear-out failure will not occur, allowing for 1 hours of continuous operation or more (survival rate of 9% or higher). About Expected Life The 1 hours of expected life indicates that more than 9% of fans will satisfy the following criteria when used at an ambient temperature of C (14 F). Criteria: Speed (at rated voltage): Greater than 7% of rated speed Input Current (at rated voltage): Less than 13% of rated current $$ The Low-Speed Alarm: An alarm is output when the fan speed drops to 7% or less. No Alarm Output Low-Speed Alarm Output Host Controller Rated speed Speed 7% max. Low-Speed Alarm Signal Alarm Output $$ Easy-to-Connect Fan s are also Available. We have a cable with a connector for easy connection in addition to the standard lead wire type. The connector type fan can reduce wiring. Maintenance is also very easy because the fans can be replaced just by disconnecting the connector. $$ All Necessary Items for Installation are Included. The finger guard, cable with connector and mounting screws are included, so they can be used immediately. Power Supply Cable with Connector Finger Guard (Included) (Included) Mounting Screws (Included) $ $ Alarm Cable with Connector (Included with the alarm type) Fan 1

The Advantages of Using Long-life Axial Flow Fans $$ Reduction of Equipment Maintenance Long-life axial flow fans have an expected life of 1 hours, so the number of cooling fans that need replacing is decreased compared to conventional models. Comparison of the service life of conventional models and long-life fans (example) Conventional models 1 (MRS16) Long-life fans 1 (MRE16) About 3 hours 2 Approx. 2.8 About 1 hours 1 The conventional models are T-MRS16-BTA-G and MRS16-BTA. The long-life fan is MRE16-BBHG. 2 Estimated life of 3 hours with an ambient temperature of C (14 F). Estimated life is an estimated value calculated using the bearing life-of-grease formula. Estimated life is different for each model. $$ Equipment That Requires High Reliability Expected life of 1 hours or more (continuous operation). Suitable for applications where continuous operation is required when a failure has had a large effect on systems and equipment. [Applications] $$Back-up equipment for power failures $$Equipment installed in data centers, etc. $$Plant equipment that is continuously operational $$ Hard-to-service Environments [Examples of Hard-to-service Environments] $$Equipment that is continuously operational and cannot be stopped $$Areas that are hard to enter $$Equipment that is delivered to and installed in remote locations $$ Early Detection of Reduced Air Flow Capacity and Other Abnormalities (Low-Speed Alarm) If the cooling fan is a low-speed alarm type, early detection and handling of abnormalities is possible. This protects the equipment and entire system from the risk of reduced air flow capacity and stalling due to unexpected troubles, increasing reliability. Cell site 2

General Specifications $$ AC Axial Flow Fans Item Insulation Resistance Dielectric Strength Temperature Rise Operating Voltage Range Thermal Class Overheat Protection Operating Environment Storage Condition Color Materials Specifications 1 MV or more when VDC megger is applied between the windings and the frame after continuous operation under normal ambient temperature and humidity. Sufficient to withstand 1.5 kvac at Hz applied between the windings and the frame for 1 minute after continuous operation under normal ambient temperature and humidity. 3 C (54 F) or less measured by the thermometer method after the temperature of the case has stabilized after continuous operation under normal ambient temperature and humidity. w1% of the rated voltage UL/CSA standards: 15 (A), EN standards: 12 (E) MRE Series has built-in thermal protector. (automatic return type) Open: 12w5 C (248w9 F), Close: 77w15 C (17.6w27 F) Provided in a separate box. Provided in a separate box. Frame: Dark Gray Blades: Black Frame: Die cast aluminum Blades: Polycarbonate (Flammability grade: V-) Operating Environment and Storage Condition Standard Low-Speed Alarm Operating Environment 1 Storage Condition 1 2 Environmental Standards Ambient Temperature Ambient Humidity Ambient Temperature Ambient Humidity s3pr C (s22pr14 F) s2pr C (s4pr14 F) 85% or less (non-condensing) s4pr7 C (s4pr158 F) s2pr7 C (s4pr158 F) 85% or less (non-condensing) Compliant with ETSI standards 3 1 The operating environment and storage conditions require no condensation, no freezing and no vibration or external force other from the fan. 2 The storage condition applies to a short period such as a period during transportation. 3 The operating environment and storage condition are compliant with the following environmental standards: ETSI EN 3 19-2-1 V2.1.2 (2-9) Class 1.3E Storage ETSI EN 3 19-2-2 V2.1.2 (1999-9) Class 2.3 Transportation ETSI EN 3 19-2-3 V2.2.2 (23-4) Class 3.4 Stationary use Heat Cycle Test Test Name Environmental Standards Conditions and Test Details Low-Temperature Shelf Test ETSI EN 3 19-2-1 ETSI EN 3 19-2-2 ETSI EN 3 19-2-3 5 cycles at 4pr3 C ( 4pr86 F), temperature gradient: 1. C (1.8 F)/min. Low temperature: [ 4 C ( 4 F)], High temperature: [+3 C (r86 F)]. Shelf time: 3 hours No abnormality after the test. 45 C ( F). Shelf time: 72 hours. No abnormality after the test. $$ Environmental Standards: ETSI ETSI is the abbreviation for the European Telecommunications Standards Institute, and is a standardization organization established to formulate standard models for telecommunications in Europe. The ETSI EN 3 19 series are standards based on IEC 721, established for environmental conditions for devices, and provide specific definitions of environmental conditions along with test conditions. Product Number Code MRE 16 - B B H G 1 2 3 4 5 6 MRE 16 - T H 2 G 1 2 3 5 7 6 1 Series Name MRE: MRE Series 2 Frame Size 16: 1 mm (6.3 in.), 18: 18 mm (7.9 in.) Voltage B: //5 VAC 3 D: /23 VAC T: /22/23 VAC Additional Function Blank: With no Additional Functions A: Low-Speed Alarm, Contact Alarm 4 (Normal Operation: Contact OFF) B: Low-Speed Alarm, Contact Alarm (Normal Operation: Contact ON) M: Low-Speed Alarm, Electronic Alarm 5 Connection H: With Connector 6 Accessory G: Finger Guard 7 Reference Number 3

Low-Speed Alarm Specifications The alarm specifications vary depending on the type of alarm. Check the alarm and sensor specifications according to the model name you use. Specifications can also be referred to by the alarm specifications number and the sensor specifications number shown on the specifications for each product. $$ Low-Speed Alarm, Contact Alarm An alarm is output when the fan speed drops to a specific level. Output mode is contact output. Alarm Specifications Number 1 Models MRE Series: MRE18- BHG, MRE16- BHG Alarm Specifications Alarm Activation Speed 18 3 r/min Output Mode Relay Output Output Condition Normal Operation: Contact ON Alarm Output: Contact OFF Maximum Rating Contact capacity Resistive load max. 1 VA (max. 1 V/max..5 A) Minimum load 5 VDC 1 ma (Design your circuit to operate at.5 ma max.) Delay Function None (External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be 1 sec. min.) Example of Alarm Output Circuit Connection Fan R V Customer's Circuit Alarm Specifications Number 2 Models MRE Series: MRE18- AHG, MRE16- AHG Alarm Specifications Alarm Activation Speed 18 3 r/min Output Mode Relay Output Output Condition Normal Operation: Contact OFF Alarm Output: Contact ON Maximum Rating Contact capacity Resistive load max. 1 VA (max. 1 V/max..5 A) Minimum load 5 VDC 1 ma (Design your circuit to operate at.5 ma max.) Delay Function None (External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be 1 sec. min.) Example of Alarm Output Circuit Connection Fan R V Customer's Circuit $$ Low-Speed Alarm, Electronic Alarm An alarm is output when the fan speed drops to a specific level. Output mode is electronic output. Alarm Specifications Number 3 Models MRE Series: MRE18- MHG, MRE16- MHG Alarm Specifications Alarm Activation Speed 18 3 r/min Output Mode Open-Collector Output Output Condition Normal Operation: L Level (Internal transistor ON) Alarm Output: H Level (Internal transistor OFF) Maximum Rating Maximum Applied Voltage: 3 VDC max. Maximum Inflow Current: 15 ma max. Delay Function None (External delay circuit is required to prevent alarm detection when starting the fan. The delay time should be 1 sec. min.) Example of Alarm Output Circuit Connection Fan 15 ma max. 3 VDC max. R V Customer's Circuit 4

AC Long Life Axial Flow Fans MRE Series 18 mm 9 mm Thick (M7.9 in. 3.54 in. Thick) #With Alarm Operating Voltage Range: ±1% (Applies to each voltage) Materials Frame: Die cast aluminum Blades: Polycarbonate (Flammability grade V-) Overheat Protection: Built-in thermal protector Bearings: Ball bearings Specifications Low-Speed Alarm Contact Alarm <Alarm Specifications: 1> (Normal Operation: Contact ON) Standard Model MRE18-BBHG MRE18-DBHG MRE18-TBHG MRE18-BHG MRE18-DHG MRE18-THG Voltage Frequency Current Input Speed Max. Air Flow Max. Static Pressure Noise Level VAC Hz A W r/min m 3 /min CFM Pa inh2o db (A) 28 4 33 4 33 4 Single-Phase Single-Phase 5 Single-Phase 23 Three-Phase 22 Three-Phase 23 Single-Phase Single-Phase 5 Single-Phase 23 Three-Phase 22 Three-Phase 23.57.75.73.72.27.36.34.24.25.25.26.57.75.73.72.27.36.34.24.25.25.26 $ $ Alarm specifications 1 Page 4 $$ Low-speed alarms of other specifications are also available. Contact Alarm (Normal operation: Contact OFF): MRE18-MAHG Alarm specifications 2 Page 4 Electronic Alarm : MRE18-MMHG Alarm specifications 3 Page 4 54.5 76 81 84 54.5 7 77 7 74 76 54.5 76 81 84 54.5 7 77 7 74 76 28 33 28 33 33 28 33 33 28 33 28 33 33 4 4 4 4 4 4 4 4 4 4 4 4 4 The following items are included in each product. Fan, Finger Guard, Mounting Screws [M5 2 mm (.79 in.)], Power Supply Cable, Alarm Cable (included with the alarm type), Operating Manual Air Flow Static Pressure Characteristics (Characteristics when a finger guard is not installed) Static Pressure [inh2o] 1.6 1.4 1.2 1..8.6.4.2 Static Pressure [Pa] 4 3 32 28 24 2 1 12 8 4 Hz Speed Hz Hz Static Pressure Hz 4 3 32 24 2 1 12 8 4 Speed [r/min] 2. 4. 6. 8. 1. 12. 14. Air Flow [m 3 /min] 1 2 3 4 Air Flow [CFM] Other Low-Speed Alarm MRE Series has other low-speed alarm fans. For details on this product please refer to our website, contact technical support or your nearest Oriental Motor sales office. www.orientalmotor.com Low-Speed Alarm Voltage Model //5 VAC MRE18-BAHG Contact Alarm /23 VAC MRE18-DAHG (Normal Operation: Contact OFF) /22/23 VAC MRE18-TAHG //5 VAC MRE18-BMHG Electronic Alarm /23 VAC MRE18-DMHG /22/23 VAC MRE18-TMHG $ $ Either B, D or T indicating voltage is entered in the box is located within the product name. 5

Dimensions Unit = mm (in.) $$ Fan Mass: 2.5 kg (5.5 Ib.) Standard E1 Alarm E151 Connector for alarm (Not included with standard type) 76 (2.99) Connector for Power Supply 35 (1.38) 15 (4.13) 28 (1.1) Protective Earth Terminal M4 ϕ1 (ϕ.39) Unpainted Air Flow 18 (7.9) 1.7±.5 (6.1±.2) Rotation Direction 6 (.24) 9 (3.54) 6 (.24) 1.7±.5 (6.1±.2) 18 (7.9) 8 ϕ5.5 (ϕ.217) $$ Finger Guard (Included) Conformed Component for Safety Standards Mass: 95 g (3.4 oz.) E55 5 (.2) 5.5 (.217) 218 (8.58) 175 (6.89) 182 (7.17) $$ Power Supply Cable with Connector (Included) 1 (39.37) Connector: 5557-4R-21 (MOLEX) ϕ6.4 (ϕ.25) Core Wires: AWG18 $ $ The area is not available with the single-phase type. $$ Alarm Cable with Connector (Included with the alarm type) 1 (39.37) Connector: 5557-2R-21 (MOLEX) ϕ5.8 (ϕ.23) Core Wires: AWG2 6

Panel Cut-Out Unit = mm (in.) 171 (6.73) 1.7 (6.1) 4 ϕ5.5 (ϕ.217) 1.7 (6.1) 4 ϕ5.5 (ϕ.217) 171 (6.73) 1.7 (6.1) ϕ192 (ϕ7.) 1.7 (6.1) 178 (7.1) Outlet Side Intake Side Connection Diagram Single-Phase Alarm Cable PE Power Supply Cable N L White Black Three-Phase Alarm Cable PE L1 (R) Power Supply Cable L2 (S) L3 (T) Included with the alarm type Red White Black Accessories Product Finger Guard Filter Product Name FG18D FL18 Another finger guard needs to be purchased separately when using the finger guard on both sides. $$ For detailed accessories information see Oriental Motor General Catalog or visit www.orientalmotor.com. 7

AC Long Life Axial Flow Fans MRE Series 1 mm 62 mm Thick (M6.3 in. 2.44 in. Thick) #With Alarm Operating Voltage Range: ±1% (Applies to each voltage) Materials Frame: Die cast aluminum Blades: Polycarbonate (Flammability grade V-) Overheat Protection: Built-in thermal protector Bearings: Ball bearings Specifications Low-Speed Alarm Contact Alarm <Alarm Specifications: 1> (Normal Operation: Contact ON) Standard Model MRE16-BBHG MRE16-DBHG MRE16-TBHG MRE16-BHG MRE16-DHG MRE16-TH2G Voltage Frequency Current Input Speed Max. Air Flow Max. Static Pressure Noise Level VAC Hz A W r/min m 3 /min CFN Pa inh 2 O db (A) Single-Phase Single-Phase 5 Single-Phase 23 Three-Phase 22 Three-Phase 23 Single-Phase Single-Phase 5 Single-Phase 23 Three-Phase 22 Three-Phase 23.45.44.46.48.21.21.22.15.13.14.15.45.44.46.48.21.21.22.15.13.14.15 $ $ Alarm specifications 1 Page 4 $$ Low-speed alarms of other specifications are also available. Contact Alarm (Normal operation: Contact OFF): MRE16- AHG Alarm specifications 2 Page 4 Electronic Alarm : MRE16- MHG Alarm specifications 3 Page 4 39 48 51 39 51 33 37 43 39 48 51 39 51 33 37 43 32 32 32 32 32 32.9.63.63.63.9.63.63.9.63.63.63.9.63.63.63.9.63.63.9.63.63.63 The following items are included in each product. Fan, Finger Guard, Mounting Screws [M5 2 mm (.79 in.)], Power Supply Cable, Alarm Cable (included with the alarm type), Operating Manual Air Flow Static Pressure Characteristic Static Pressure [inh2o] (Characteristics when a finger guard is not installed).8.7.6.5.4.3.2.1 Static Pressure [Pa] 2 18 1 14 12 1 8 4 2 Hz Speed Hz Hz Static Pressure Hz 4 3 32 24 2 1 12 8 4 Speed [r/min] 1. 2. 3. 4. 5. 6. 7. 8. Air Flow [m 3 /min] 1 1 2 2 Air Flow [CFM] Other Low-Speed Alarm MRE Series has other low-speed alarm fans. For details on this product please refer to our website, contact technical support or your nearest Oriental Motor sales office. www.orientalmotor.com Low-Speed Alarm Voltage Model //5 VAC MRE16-BAHG Contact Alarm /23 VAC MRE16-DAHG (Normal Operation: Contact OFF) /22/23 VAC MRE16-TAHG //5 VAC MRE16-BMHG Electronic Alarm /23 VAC MRE16-DMHG /22/23 VAC MRE16-TMHG $ $ Either B, D or T indicating voltage is entered in the box is located within the product name. 8

Dimensions Unit = mm (in.) $$ Fan Mass: 1.35 kg (3. lb.) Standard E148 Alarm E1 Connector for alarm (Not included with standard type) 58 (2.28) Connector for Power Supply 35 (1.38) 15 (4.13) 25 (.98) Protective Earth Terminal M4 ϕ1 (ϕ.39) Unpainted Air Flow 1 (6.3) 138.5±.5 (5.45±.2) Rotation Direction 4 (.16) 62 (2.44) 4 (.16) 138.5±.5 (5.45±.2) 1 (6.3) 8 ϕ5.5 (ϕ.217) $$ Finger Guard (Included) Conformed Component for Safety Standards Mass: 75 g (2.6 oz.) E 5.5 (.217) 5 (.2) $$ Power Supply Cable (Included) 1 (39.37) Connector: 5557-4R-21 (MOLEX) $ $ The area is not available with the single-phase type. ϕ6.4 (ϕ.25) Core Wires: AWG18 198 (7.8) $$ Alarm Cable (Included with the alarm type) 1 (39.37) 151 (5.94) 158 (2) Connector: 5557-2R-21 (MOLEX) ϕ5.8 (ϕ.23) Core Wires: AWG2 Panel Cut-Out Unit = mm (in.) 1 (6.14) 138.5 (5.45) 4 ϕ5.5 (ϕ.217) Connection Diagram Single-Phase Alarm Cable 1 (6.14) 138.5 (5.45) ϕ175 (ϕ6.89) PE N Power Supply Cable L Three-Phase Alarm Cable White Black Accessories Product Finger Guard Filter Outlet Side/Intake Side Product Name FG16D FL16 Another finger guard needs to be purchased separately when using the finger guard on both sides. $$ For detailed accessories information see Oriental Motor General Catalog or visit www.orientalmotor.com. PE L1 (R) Power Supply Cable L2 (S) L3 (T) Included with the alarm type Red White Black Specifications are subject to change without notice. This catalog was published in February, 212. #48 9