VIRTUAL FIRES via COMPUTERS

Similar documents
Simple Equations for Predicting Smoke Filling Time in Fire Rooms with Irregular Ceilings

NUMERICAL SIMULATION OF THE NEW SOUTH WALES FIRE BRIGADE COMPARTMENT FIRE BEHAVIOUR TRAINING TEST CELL

Considerations in the Design of Smoke Management Systems for Atriums

CFD Model of a Specific Fire Scenario

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

Recent BRANZFIRE enhancements and validation

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

5B-3 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

ANALYSIS OF SMOKE MOVEMENT IN A BUILDING VIA ELEVATOR SHAFTS

Modeling water-mist based suppression of 34 GJ car-deck fires using FDS

THE COMBINATION OF FIRE EXTINGUISH SYSTEM AND LOCAL EXHAUST SYSTEM IN FUME HOOD

Advantages and Disadvantages of Fire Modelling

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Modeling a real backdraft incident fire

Water Mist-Based Fire Suppression Modelling of an Office Space Scenario

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Smoke Layer Height and Heat Flow through a Door

Fire Scenario Influence of Material of Boundary Condition on Results

Case Study : Evaluation Smoke & Evacuation Performance of a College Auditorium

Computer Models For Fire and Smoke

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

Human Factors - Egress Analysis for High Hazard Occupancies. Presented by: Michael J. Klemenz, PE, SFPE

Case Study 1 Underground Car Park

Figure 1. Structure Used For the Simulations.

Full-Scale Measurement and Numerical Analysis of Liquefied Petroleum Gas Water Heaters with Ventilation Factors in Balcony

COMPARISON OF CFD MODELLING WITH FIRE TESTS Comparison of CFD Modelling with Results of Full Scale Compartment Fire Tests in a Residential Unit

PREDICTING SMOKE DETECTOR ACTIVATION USING THE FIRE DYNAMICS SIMULATOR

SMOKE MANAGEMENT AND EGRESS ANALYSIS OF A SPORTS ARENA USING THE PERFORMANCE-BASED DESIGN

Tunnel Fire Dynamics and Evacuation Simulations

Fire Protection as the Underpinning of Good Process Safety Programs

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

Virtual Compartment: An Alternative Approach to Means of Egress Design in Airport Pedestrian Tunnel

Natural Ventilation A Green Smoke Control Approach

ctbuh.org/papers Fire Engineering the Tallest Building in the Historic City of Manchester, UK Title:

Fire Research and Education at the University of Maryland

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

Uncertainty Analysis For Input Parameters Of Electrical Cabinet Fire Simulation By Coupling Latin Hypercube Sampling And CFAST

ABSTRACT. Stephen Kerber, Master of Science, Dr. James Milke, Fire Protection Engineering

Fire and smoke management in a uni-directional road tunnel for a congested traffic condition

AN ANALYSIS OF THE PERFORMANCE OF RESIDENTIAL SMOKE DETECTION TECHNOLOGIES UTILIZING THE CONCEPT OF RELATIVE TIME

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Case Study 2 (Production and Storage Buildings) - Spain

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Recent Advances in Fire Suppression Modeling Issues & Perspectives of Fire Safety Engineering Applications

Shalaby Institute of Fire Protection Heyrothsberge, Germany.

Smoke Layer Height and Heat Flow through a Door

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

Compression of Fins pipe and simple Heat pipe Using CFD

Computer Simulation Investigation on the Effect of Channelled and Unchannelled Screens on Smoke Contamination in Atriums Upper Balconies

FDS MODELLING OF HOT SMOKE TESTING, CINEMA AND AIRPORT CONCOURSE

SIMULATION OF A COMPARTMENT FLASHOVER FIRE USING HAND CALCULATIONS, ZONE MODELS AND A FIELD MODEL

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

Fire Investigation in Italian Waste Treatment Plant: lessons learned and future development

Research Needs for the Fire Safety Engineering Profession

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

Sprinklers Modeling for Tunnel Road Fire Fighting

First Revision No. 6-NFPA [ Section No. 2.2 ]

An experimental study of the impact of tunnel suppression on tunnel ventilation

ICC CODE CORNER 2012 IFC Code & Commentary

Test One: The Uncontrolled Compartment Fire

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

TENABILITY CRITERIA IN UNIQUE SITUATIONS AND ATYPICAL BUILDINGS

ICC CODE CORNER 2012 IFC Code & Commentary

A NETWORK MODEL OF SIMULATING SMOKE MOVEMENT IN BUILDINGS

INFLUENCE OF SOLAR RADIATION AND VENTILATION CONDITIONS ON HEAT BALANCE AND THERMAL COMFORT CONDITIONS IN LIVING-ROOMS

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

Aspirating Gas Detection CFD Modelling Predicts Application Performance

Fire and Smoke Management in a Uni-Directional Road Tunnel for a Congested Traffic Condition

A study for a fire spread mechanism of residential buildings with numerical modeling

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Presentation prepared by: Robert N. Meroney, Professor Wind Engineering and Fluids Laboratory, Colorado State University, Fort Collins, CO 80523

FLACS-Fire. Djurre Siccama Gexcon R&D and Software VP Products. FLUG 3 rd - 4 th. November 2015, Shanghai China

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

An Analysis of Compartment Fire and Induced Smoke Movement in Adjacent Corridor

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

ABSTRACT 1 INTRODUCTION

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Tenability criteria for design of smoke hazard management systems

A Brief on Performance- Based Design for Building Fire Safety

CFD Analysis of Fire Characteristics on Subway Junction Station

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

Edward K. Budnick Hughes Associates, Inc. Wheaton, Maryland, U.S.A SUMMARY. that is entrained or otherwise mixed into the mass.

Engineering Simulation in Built Environment and Civil Engineering Projects

APPLYING LARGE EDDY SIMULATION IN THE STUDY OF FIRE AND SMOKE SPREAD AT UNDERGROUND CAR PARK

Computational simulation of road tunnel fire protection by sprinklers

CFD ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC)

26 June 2001 GUIDELINES ON ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY

SMOKE CONTROL: ISSUES / APPROACHES. Smoke, Not Flame

Evaluation of the NFPA 72 Spacing Requirements for Waffle Ceilings

Travelling Fires for CFD

METHODOLOGY. Definitions. A Collaboration of U.S. NRC Office of Nuclear Regulatory Research (RES) & Electric Power Research Institute (EPRI)

Transcription:

VIRTUAL FIRES via COMPUTERS Robert N. Meroney Wind Engineering Software Wind Engineering and Fluids Laboratory Civil and Environmental Engineering Colorado State University, Fort Collins, CO Paper prepared for 1 st American Association for Wind Engineering - Workshop 21-22 August, 2008 Marriott Hotel Vail, CO, USA Wind Engineering Software

1 VIRTUAL FIRES via COMPUTERS Robert N. Meroney a a Colorado State University, Fort Collins, CO USA ABSTRACT: This paper discusses simulation of a design fire in a typical building including mitigation with sprinklers and ventilation, but as affected by an approach boundary layer wind field. The computations used both CFAST (a zone fire model) and FDS (a field model) developed by NIST. The work combines understanding of building aerodynamics, exfiltration, infiltration, fire physics, and heating and ventilating. 1 INTRODUCTION: Recent publication of world fire statistics reveals that costs of fires including prevention, protection and repression currently runs around 1% of GDP in most advanced countries. Deaths and losses in the United States tend to be the most extreme with annual losses of $13 bn/year. 1 The annual review performed by Munich Re of world disaster losses reveals that world-wide forest fire losses alone exceeded US$5.5bn and insured losses exceeded US$2.5bn during 2003. Such losses exceeded the sum of all losses from volcanic eruptions, hailstones, flash floods, tsunamis, landslides, avalanches, water drainage, frost, and local and winter storms combined! 2,3 (Of course extreme events like the Baran earthquake, the European heat wave, floods, and severe and tropical storms like Katrina can individually exceed fire losses.) Human risk is demonstrated by the 2004 fire at a shopping mall in Asuncion, Paraguay during which 400 people were killed and hundreds were severely injured. Building to preserve occupant safety is controlled by various national and international fire 4, 5, 6, 7 codes. Predicting smoke and flame behavior can be based on full-scale field experience, analytic integral approximations that capture the gross flow behavior, fine-scale numerical modeling and/or physical modeling at reduced scale...these methods are typically called full-scale, zone (algebraic or ode numerical), field (pde numerical), and physical modeling, respectively (a review 8, 9, 10 of these alternatives is found in Meroney, 2007). In this paper we will focus on the potential of a fast zone model (CFAST) versus the finer details provided by a field or CFD model (FDS). 1.1 Merits of Virtual Modeling of Fire through Numerics Computational fluid dynamics (CFD) provides a design technique to examine the relative merits of various fire suppression strategies. Such programs can inherently consider irregular building and terrain geometry, heat transfer due to variable properties and radiation, time varying fire strength, fire chemistry, effect of fire suppression operation, and variations in weather phenomena. Realistically, however, many of our computational sub-modules for combustion, radiation, pyrolysis, etc. are still primitive, and even inclusion of all models within a computation becomes cumbersome to calculate, and excessive in use of computational resources and time. Models are also constrained by the simulation model chosen, since continued verification and validation are required at almost every level of CFD prediction. Thus, one should ask when is a fast approximate model appropriate, and when should one take the time to predict fire and flow details?

2 1.2 Merits of Integral Models vs Field Models Integral Model: The software Consolidated Model of Fire Growth and Smoke Transport (CFAST) is a two-zone (layer) per room integral model used to calculate the evolving distribution of smoke, fire gases and temperature throughout compartments of a building during a fire. These can range from very small containment vessels, on the order of 1 m 3 to large spaces on the order of 1000 m 3 11, 12. The modeling equations used in CFAST take the mathematical form of an initial value problem for a system of ordinary differential equations (ODEs). These equations are derived using the conservation of mass, the conservation of energy (equivalently the first law of thermodynamics), the ideal gas law and relations for density and internal energy. These equations predict as functions of time quantities such as pressure, smoke layer height and temperatures given the accumulation of mass and enthalpy in the two layers. The CFAST model thus consists of a set of ODEs to compute the environment in each compartment and a collection of algorithms to compute the mass and enthalpy source terms required by the ODEs. The program has added features to account for constant and time-dependent fire sources; suppression effects of water sprinklers, CO 2, or oxygen depletion; the effects of horizontal and vertical openings and mechanical flow vents; the presence of walls made of layered materials; thermal detectors, smoke alarms and water sprinklers; and the effects of external wind on flow through horizontal vents. 8 Fires in CFAST are pre-specified in terms of Heat Release Rate (HRR) based on empirical measurements; hence, the fire physics is not incorporated in the solution. Field Model: The software Fire Dynamics Simulator (FDS) is a computational fluid dynamics (CFD) model of fire-driven fluid flow. FDS solves numerically a form of the Navier-Stokes equations appropriate for low-speed, thermally-driven flow with an emphasis on smoke and heat 13, 14, 15 transport from fires. The core algorithm is an explicit predictor-corrector scheme, second order accurate in space and time. Turbulence is treated by means of the Smagorinsky form of Large Eddy Simulation (LES). FDS primarily uses a single step chemical reaction tracked via a two-parameter mixture fraction model to incorporate combustion, but, recently, adjustment algorithms permit the inclusion of suppression by oxygen depletion, CO 2 presence and water sprinklers. Both CFAST and FDS can present results visually through the graphics program, SmokeView, that displays time varying slices, isosurface contours, and vector fields of temperature, concentrations, soot, pressure and velocities. 16 Verification and Validation: The CFAST and FDS models have been subjected to extensive validation studies by NIST and others. 17 Table 1 summarizes how the two models performed when compared to ten experimental situations covering a range of fire scenarios. Typically predictions are accurate within 10 % to 25 % of the measurements, which were often within the range of uncertainty of the experiments. For the most cases considered, the results of the field model, FDS, were not significantly better than those of the two-zone model, CFAST. FDS solves the basic transport equations instead of empirical and integral correlations, making it a more predictive model. However, the computational cost of solving the basic equations is substantial. The two-zone models produce answers in seconds to minutes, while FDS produces comparable answers in hours to days. FDS is better suited to predict fire environments within more complex geometric configurations because it predicts the local effects of a fire.

3 2.0 VIRTUAL FIRES IN A REPRESENTATIVE BUILDING Comparison calculations were performed for a three-story gable-roofed building of rectangular planform. The building included a central stair case surrounded by a partial smoke curtain which connected the principal rooms on all three floors (giving the configuration an atrium-like characteristic). Additional offices, lobbies, and stairwells connected to the principal rooms on the 1 st and 2 nd floors. The configuration included flow through inlet and outlet registers, passive pressure driven vents, and preset mechanical exhaust vent flows on each floor and in the roof. A design fire of a burning upholstered chair located on the 1 st level in a lounge fire was specified. Water sprinklers were installed above the chair to be activated by a heat detector. Additionally, he International Fire Code specifies that the influence of an extreme wind about the building occurring at a 1% likelihood be considered. 7 A wind condition set to 11.8 m/s (25 mph) at a 10 m height was incorporated into the analyses. CFAST considers each room a separate compartment connected by horizontal and vertical vents (doors, windows, and ceiling openings). Room location is not relevant, just which rooms connect. Vent location is also not important other than their height above floor level. However, the program allows one to arrange compartments and vents horizontally and vertically to reflect their actual orientation in Smokeview (see Figure 1). FDS aligns all surfaces within a rectangular grid; hence, curved and inclined surfaces appear as saw-toothed shapes. Nonetheless, all vents, registers, fans, fires, stairs, and sprinkler systems can be placed in their actual positions and orientations (see Figure 2). The upholstered chair design fire used in both CFAST and FDS simulations were identical. Figure 3 indicates the time dependent variation of Heat Release Rate (HRR) in kw versus time in seconds. Each calculation was permitted to simulate times up to 1200 seconds (20 min). Wind effects are treated differently in the two models. In CFAST wind effects are determined from the building orientation and vent locations. Vents are subjected to positive or negative pressures dependent on a reference velocity, wind orientation and empirical pressure coefficients. This can result in enhanced ventilation through upwind vents, or reversal of flow from inlet to exhaust for downwind vents. In FDS the actual flowfield around the building is explicitly calculated, and associated secondary flows and pressure fields are determined from the flow dynamics (see Figure 4). 3.0 COMPARATIVE RESULTS The zonal model of CFAST routinely produces time-dependent layer-averaged temperatures (ULT - upper layer temperature and LLT - lower layer temperature) and smoke layer heights (SLH) for each compartment. The field model FDS can calculate the spatial variation of temperatures, velocities, concentrations and soot throughout each room and on the external faces of the structure. A detector was placed in a central location on each floor of the FDS simulation which also permits local specification of ULT, LLT and SLH. However, since the detector has a unique location, the values are not layer-averaged over the entire floor; hence, it is expected FDS- predicted SLH minimums will be smaller than CFAST SLH minimums, and FDS- predicted ULT & LLT maximums will be larger than CFAST values. Several of the CFAST and FDS simulations are compared in Figures 5 to 8. Each floor level and the conditions within the stair wells are displayed in separate bar charts. The left axis displays ULT and LLT temperatures ( o C), whereas the right axis displays SLH (meters). A simple design goal for occupancy safety would be to mitigate the fire such that the SLH remains above 2 m and the maximum exposure temperatures remain below 30 o C (a 10 o C increase in temperature over ambient conditions is often associated with visibility decreased below 10 m or 30 ft.) Thus, the

black dotted arrow line points to a 2 m SLH, and the red dotted arrow line points to a 30 o C temperature. If these conditions are not maintained, then one designs for a tenable evacuation situation which does not expose occupants to excessive heat for too long. Human exposure studies have shown that temperatures up to 50 o C are tenable for periods up to 600 sec (10 min) or up to 70 o C for short periods (100-300 sec). Results shown in Figures 5 to 8 suggest there are a few situations where SLH falls below 2m and ULT rise above 30 o C. However, closer examination of the detailed data time traces indicate that thermal exposure times are always less than 300 sec even for ULT as high as 60 o C. Separate obscuration detectors included in the FDS simulation also showed that at no time did the percent obscuration rise above 30%. A 30% obscuration permits sign visibility out to 77 m (252 ft); hence, visibility is not an issue during this simulated fire. 4.0 SUMMARY An integral fire prediction model like CFAST provides a fast and accurate screening model during fire and smoke mitigation design studies. Its flexibility and speed permit many alternative scenarios to be examined quickly. On the other hand, some fire scenarios are not accurately defined by a twozone model, or it is anticipated that spatial inhomogeneities within a room may influence smoke development and propagation. In these cases a field model like FDS provides valuable additional details concerning fire and smoke development. 5.0 REFERENCES 1. Geneva Association, World Fire Statistics, Bulletin 22, International Association for the Study of Insurance Economics, Geneva, Switzerland, 10pp., October 2006. http://www.genevaassociation.org/fire%20n%c2%b022.pdf 2. Munich Re, Trends of Great Natural Catastrophes Since 1950, TOPICS Geo: Annual Review Natural Catastrophes in 2003, 2004. http://www.munichre.com/ 3. Munich Re, Trends of Great Natural Catastrophes Since 1950, TOPICS Geo: Annual Review Natural Catastrophes in 2005, 2006. http://www.munichre.com/ 4. Klote, J.H. and Evans, D.H. A Guide to Smoke Control in the 2006 IBC, International Code Council, 2007, 211 pp. 5. NFPA, Standard for Smoke Management Systems in Malls, Atria, and Large Spaces, NFPA 92B, National Fire Protection Association, 2005 edition, 57 pp. 6. NFPA,, Standard for Smoke and Heat Venting,, NFPA 204, National Fire Protection Association, 2007 edition, 83 pp. 7. ICC, 2006 International Fire Code, International Code Council, Inc., Country Club Hills, IL, 433 pp. 8. Klote, J.H. and Milke, J.A., Principles of Smoke Management, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta, GA, 2002, 387 pp. 9. Meroney, R.N. Fires in porous media: natural and urban canopies, Chapter 8 in Flow and Transport Processes with Complex Obstructions (ed. Y.A. Gayev and J.C.R. Hunt), NATO Science Series, Springer, Berlin, 2007. http://www.engr.colostate.edu/~meroney/index.html 10. Meroney, R.N. Numerical Prediction of Fire Propagation in Idealized Wildland and Urban Canopies, 12 th International Conference on Wind Engineering, 1-6 July 2007, Cairns, North Queensland, Australia, 8 pp. 11. Jones, W.W., Peacock, R.D.,Forney, G.P., and Reneke, P.A., CFAST - Consolidated Model of Fire Growth and Smoke Transport (Version 6): Technical Reference Manual,, NIST Special Publication 1026, 2005, 146 pp. 12. Peacock, R.D., Jones, W.W., Reneke, P.A., and Forney, G.P. CFAST-Consolidated Model of Fire Growth and Smoke Transport (Vresion 6), NIST Special Publication 1041, 2008, 103 pp. 13. McGrattan, K.B., Baum, H.R., and Rehm, R.G., Large Eddy Simulations of Smoke Movement, ASHRAE Transactions 1999, Paper CH-99-1-4, Vol. 105, Pt. 1, 11 pp., 1999. or Fire Safety Journal Vol. 30, 1998, 161-178. http://www.fire.nist.gov/fds/fds98/pdf/s98002.pdf 14. McGrattan, K., Baum, H., Rehm, R., and McDermott, R., Fire Dynamics Simulator (Version 5), Technical Reference Guide, NIST Special Publication 1018-5, 2008, 100 pp. 15. McGrattan, K., Hostikka, S., and Floyed, J., Fire Dynamics Simulator (Version 5), User s Guide, NIST Special Publication 1019-5, 2008, 226 pp. 16. Forney, G.P., User s Guide for Smokeview Version 5 - A Tool for Visualizing Fire Dynamics Simulation Data, NIST Special Publication 1017-1, 2008, 136 pp. 17. U.S. Nuclear Regulatory Commission, Verification and Validation of Selected Fire Models for Nuclear Power Plant Applications, Vol 1: Main Report, NUREG-1824, Office of Nuclear Regulatory Research, Washington DC, 2006, 66 pp; Vol 4: CFAST, pp.; and Vol. 6: Fire Dynamics Simulator (FDS), 207 pp. 4

5 Parameter Fire Model CFAST FDS Hot gas layer temperature ( Upper Layer Temperature ) Room of origin Green Green Adjacent room Yellow ±30% Green Hot gas layer height ( Layer interface height ) Green Green Ceiling jet temperature ( Target/Gas temperature ) Yellow -16 to +100% Yellow ±20% Plume temperature Not calculated Green Flame Height Green Yellow 1 Oxygen concentration Yellow ±20% Yellow ±20% Smoke Concentration Yellow-35 to +450% Yellow -33to +400% Room pressure Green Green Target temperature Yellow ±50% Yellow ±30% Radiant heat flux Yellow-50 to +150% Yellow ±50% Total heat flux Yellow -90 to +70% Yellow ±30% Wall temperature Yellow ±60% Yellow ±50% Total heat flux to walls Yellow -70 to +90% Yellow ±30% Criterion 1 - Are the physics of the model appropriate for the calculation being made? Criterion 2 - Are there calculated relative differences outside the experimental uncertainty? Green : Both criteria are satisfied, model can be used with confidence Yellow Red : 1 st criterion is satisfied, but differences are outside experimental uncertainty with no pattern of over- or under-prediction. : 1 st criterion is not satisfied. 1 FDS does not use an empirical correlation to predict the flame height. Rather, it solves a set of equations appropriate for reacting flows and predicts the flame height as the uppermost extent of the combustion zone. This is a challenging calculation and the Yellow emphasizes that caution should be exercised by users. Table 1: Results of the Validation and Verification of CFAST and FDS for Nuclear Power Plant Fire Modeling Applications 12

6 Figure 1: CFAST building configuration Figure 2: FDS building configuration Figure 3: Heating Reaction Rate - upholstered chair (kw vs time, sec) Figure 4: FDS Wind field schematic Figure 5: Lower layer temperatures (LLT), Upper layer temperatures (ULT), and Smoke layer height (SLH) on Level 1 (Main floor) for various CFAST and FDS case runs, Chair fire on Level 1, SE corner.

7 Figure 6: Lower layer temperatures (LLT), Upper layer temperatures (ULT), and Smoke layer height (SLH) on Level 2 (2nd floor) for various CFAST and FDS case runs, Chair fire on Level 1, SE corner. Figure 7: Lower layer temperatures (LLT), Upper layer temperatures (ULT), and Smoke layer height (SLH) on Level 3 (3 rd floor) for various CFAST and FDS case runs, Chair fire on Level 1, SE corner.

8 Figure 8: Upper layer temperatures (ULT), and Non-tenable time increment (DT) in stair wells for various CFAST and FDS case runs, Chair fire on Level 1, SE corner.