Global Water Instrumentation, Inc.

Similar documents
Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc.

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

NOVALYNX CORPORATION MODEL A EVAPORATION PAN AUTOMATIC REFILL SYSTEM INSTRUCTION MANUAL

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

LED LAMP: To turn on the LED Lamp, press the LIGHT BUTTON located on the front. Press again to turn off.

Beacon 800 Gas Monitor Operator s Manual

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

Model VAL105 Digital Alarm Clock With Bedshaker Jack, Night Light, Variable Volume, Variable Tone.

ALM100 Alarm Module. User s Manual

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

NOVALYNX CORPORATION MODEL A & A SLING PSYCHROMETER INSTRUCTION MANUAL

GAS MONITOR Model Model


Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

PodView Level Indicator LI40 Series Manual

Model 4001 Series Single Channel Controller

FUSE PANEL Technical Practice N N/L9 10/10 GMT NEBS Level 3 Certified

Quality Refrigeration OWNER S MANUAL. Instructions for the installation, operation and maintenance of Traulsen: Heated Banquet & Transport Carts

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Tsunami 6 Site Ebb & Flow Gro System Instruction Manual

FUSE PANEL. Technical Practice N N/L33 10/10 GMT Front Access NEBS Level 3 Certified

Operating Instructions. For. Alarm Control Module. Model SSR 500

2018 PRICING. alderonind.com STANDARD PRODUCTS

1022 R/T Remote Monitor

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

Desiccant / Pump Dehumidification System. Model Operating Manual

Panel Mounted Heat Exchangers by Dantherm, Inc.

STATUS ALARM HISTORY ALARM RESET

OPERATION AND INSTALLATION MANUAL

Beacon 410A Gas Monitor Operator s Manual

Victoreen Primalert 35 Area Radiation Monitor

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

Alarm Tone Generator Model AG17

PitBoss User Manual. Version /24/2013 Copyright 2013 PumpAlarm.com, LLC

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL

RAM3 Remote Alarm Module

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

HIGH VOLTAGE A.C. PROXIMITY DETECTOR HI-PROX

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

460H INSTALLATION & OPERATION MANUAL REMOTE STROBE POWER SUPPLY IMPORTANT: 460H TM REMOTE STROBE POWER SUPPLY

Model TL104 MANTL104. Test Lamp for Flame Detection

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Mark 25 Ultrapure Water Conductivity Analyzer

FUSE PANEL. Technical Practice N N/0803 5/5 GMT Front Access NEBS Level 3 Certified

ADVANTAGE SERIES KXRP33 AIR-TO-AIR HEAT EXCHANGER

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

SONANCE ORIGINAL SERIES MEDIUM IN-WALL SPEAKERS

Automatic Humidity Controller. Model 512 (Revision C) Operating Manual

User's Guide. Pinless Moisture Meter. Model MO257

ADVANTAGE SERIES KXRP47 AIR-TO-AIR HEAT EXCHANGER

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

KNHX32 SERIES NEMA 4/4X AIR-TO-AIR HEAT EXCHANGERS

IN-GROUND SUBWOOFER INSTRUCTION MANUAL LS12T SUB LS15T SUB

SAFETY PERSONAL AC VOLTAGE (50 or 60Hz) PROXIMITY DETECTOR

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

SNOBOX P/N (120 VAC) SNOBOX P/N (230 VAC)

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: SPK-CCF848 ESD Complete K-overage Ceiling Speaker. P/N: Rev 4

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

Remote Relay Module (RRM)

LITTLE BLIZZARD XT LITTLE BLIZZARD XT/SP

LMA LINE MONITOR ALERT USER S MANUAL

Model CAC 500M Media Air Cleaner

Remote Storage Safety 3 Alarm Installation Guide

Mold Alert... Operation Manual P0270

Bench Top Ionizer Installation, Operation and Maintenance

ion Genesis Pump Controller

FireNET FN-LCD-S Serial Annunciator Installation and Operation Manual

EOS. Instruction Manual. 120V High Amperage Digital Humidity Controller. Part #

DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

D-TEK Select. Refrigerant Leak Detector

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Universal Clamp Meter

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

RK Transmitter Technical Notice

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

! "! # Please read these installation and operating instructions completely and carefully before starting.

Installation Instructions

Notes: 1 Square = 1 Foot

Cat 5 Pro Vacuum OPERATOR S MANUAL

Instruction Manual Model Backup Switch, 1 for 8

ACCURATE ELECTRONICS INC

KPHE32 SERIES WATER-TO-AIR HEAT EXCHANGER

Transcription:

Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 High Water Alarm WA400-DC WA400-AC WA400-BU WA400-FS WA400-AL 10/23/06 P/N: 01-527 - 1 -

Congratulations on your purchase of the WA400 High Water Alarm. This instrument has been quality tested and approved for providing accurate and reliable measurements. We are confident that you will find the WA400 to be a valuable asset for your application. Should you require assistance, our technical staff will be happy to help. Table of Contents I. Checklist Page 3 II. Inspection 3 III. Operation 3 IV. Models 4 V. Specifications 5 VI. High Water Alarm Installation 6 VII. I/O Terminals 10 VIII. Maintenance 12 IX. Troubleshooting 12 X. Warranty 13 * Copyright Instrumentation, Inc. 2006-2 -

I. WA400 Checklist a. High Water Alarm b. Mounting brackets (x2) c. WA400 Manual d. 115 V AC-to-12 VDC Transformer (-AC, -BU and AL models only) II. Inspection a. Your WA400 unit was carefully inspected and certified by our Quality Assurance Team before shipping. If any damage has occurred during shipping, please notify Instrumentation, Inc. and file a claim with the carrier involved. Use the checklist to ensure that you have received everything needed to operate the WA400. III. Operation The High Water Level Alarm will sound a loud speaker and flash a bright red strobe when a switch closure signal is detected. This signal is usually from a water level sensor, but can be integrated with other equipment such as our PC300 controller or any device that has a dry contact switch output. The WA400 also has the ability to output a switch closure signal to control an external device simultaneously such as samplers, pump panels, and security switches. - 3 -

IV. Models WA400-DC The WA400-DC battery powered version may be quickly deployed in temporary emergency applications or anywhere you need a level alarm where no AC power is available. The unit will strobe and sound for up to 12 hours on its eight standard 1.5 volt AA batteries. Please note that the WA600 (or any other powered sensor) should NOT be used with the WA400-DC model WA400-AC The WA400-AC externally powered version allows you to the use the alarm with water level sensors, any standard float switch, or any contact closure. WA400-BU Our WA400-BU version includes an automatic battery backup in addition to standard AC power a great feature if your AC power source may be unreliable. WA400-FS Liquid Level Float Switch with 8 AA 1.5 VDC battery power for remote sites without AC power WA400-AL Water Level Alarm Sensor with 115 VAC power - 4 -

V. Specifications Input: Outputs: Operating Voltage: Contact Switch Closure (40mA load) 12 VDC (switched) power terminals Rating: (25mA Max) Contact Switch Closure Rating: (5A @ 30V DC) WA400-DC: 1.5 V DC AA Batteries (x8) WA400-AC: 115 V AC WA400-BU: 115 V AC with 1.5 V DC AA Batteries (x8) battery backup WA400-FS: 1.5 V DC AA Batteries (x8) WA400-AL: 115 V AC Use appropriate AC converter if needed Visual Alarm: Audible Alarm: Enclosure: Weight: Dimensions: Strobe w/red lens (approx. 1 Hz) 95dB, 2900 Hz sounder (@ 10 cm) PVC, weather resistant w/wall brackets 2.5 lbs (1.1 kg) without sensor 14 long x 2-1/2 diameter (35.5cm long x 6.4cm diameter) - 5 -

VI. High Water Alarm Installation a. Slowly remove top cap to access power compartment and Input/Output terminals. Be careful not to snag or break any wires of the sensors or alarm. Speaker wires (DC, FS) models will have battery terminals. Speaker wires (AC, AL) Models will not have battery terminals. Power connected directly to the board. Power (from AC-DC converter) Note: (BU) Model will have both Battery compartment and Power wires from an AC-DC converter. - 6 -

b. Connect the switch closure sensor to the LEVEL SWITCH terminals. Sensor cabling should be cut to appropriate length to allow wiring and alarm board to fit into the enclosure. Make sure power is off when connecting sensor. Note: Refer to manual of the attached device for correct wiring. c. Turn the switch to the ON position to put the alarm into the active state. Alarm will only sound when sensor is triggered by alarm contact. Test button can be used to test strobe and speaker functionality. Hold test button down for 2 seconds to activate speaker and strobe. Release button to turn off speaker and strobe once functionality is verified. - 7 -

d. Slowly reinstall the top cap into PVC enclosure. Be careful not to snag or break any wires of the sensors or alarm. e. Install High Water Alarm with mounting brackets (included). Drill holes for brackets at 6-3/4 apart. Install clamps. Put the PVC housing into place by snapping clamps together. Clamp Clamp - 8 -

f. To change batteries (DC, FS, BU models only) while installed, slowly remove the top cap to access the board and batteries. Turn the switch to the OFF position before changing batteries. Be careful not to snag or break any wires of the sensors or alarm. g. To de-activate alarm, turn the power switch to the off position. - 9 -

VII. Input/Output Terminals a. WA400 has switched 12 V DC terminals to power an optional external device. Power switch must be ON for these terminals to output voltage. [+12 OUT and GND] b. WA400 has 1 (Normally Open) Switch Closure Output terminal to trigger an external device. [EXT SW OUT] - 10 -

c. WA400 (DC, FL models only) has the ability to connect an external DC power supply if needed. If a DC source, other than the batteries, needs to be connected, these terminals can be used. [+12 IN and GND] Note: AC, AL and BU models use this terminal as the power input from the AC-to-DC converter. - 11 -

VIII. Maintenance a. Check batteries for correct voltage periodically. Under typical conditions with no alarms, it is recommended that the unit and batteries be checked every month. The unit will strobe and sound for up to 12 hours continuously on its eight standard 1.5 volt AA batteries IX. Trouble Shooting Issue: High Water Alarm not operating correctly a. Verify power source is supplying correct voltage. b. Verify correct and solid terminal connections Other issues c. Call us for tech support: 800-876-1172 or 916-638-3429 (many problems can be solved over the phone). Fax: 916-638-3270 or Email: globalw@globalw.com. Be prepared to describe the problem you are experiencing including specific details of the application and installation and any additional pertinent information. d. In the event that the equipment needs to be returned to the factory for any reason, please call to obtain an RMA# (Return Material authorization). Do not return items without an RMA# displayed on the outside of the package. Clean and decontaminate the WA400 if necessary. Include a written statement describing the problems. Send the package with shipping prepaid to our factory address. Insure your shipment, as the warranty does not cover damage incurred during transit. - 12 -

e. When calling for tech support, please have the following information ready; 1. Model #. 2. Unit serial number. 3. P.O.# the equipment was purchased on. 4. Our sales number or the invoice number. 5. Repair instructions and/or specific problems relating to the product. X. Warranty a. Instrumentation, Inc. warrants that its products are free from defects in material and workmanship under normal use and service for a period of one year from date of shipment from factory. s obligations under this warranty are limited to, at Global Water s option: (I) replacing or (II) repairing; any products determined to be defective. In no case shall s liability exceed the products original purchase price. This warranty does not apply to any equipment that has been repaired or altered, except by Instrumentation, Inc., or which has been subject to misuse, negligence or accident. It is expressly agreed that this warranty will be in lieu of all warranties of fitness and in lieu of the warranty of merchantability. b. The warranty begins on the date of your invoice. - 13 -