DAIKIN ROOM AIR CONDITIONER. Operation Manual

Similar documents
DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

DAIKIN ROOM AIR CONDITIONER MODELS CDXS25EAVMA CDKS25EAVMA CDXS35EAVMA CDKS35EAVMA. Operation Manual

CDKD25CVM CDKD35CVM Operation Manual

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners

CONTENTS READ BEFORE OPERATION

DAIKIN ROOM AIR CONDITIONER. Operation Manual

Operation Manual MODELS FTYN25DV3B FTN25DV3B FTYN35DV3B FTN35DV3B FTYN25DAV3B FTN25DAV3B FTYN35DAV3B FTN35DAV3B DAIKIN ROOM AIR CONDITIONER.

MODELS FTX20J2V1B FTX25J2V1B FTX35J2V1B FTX20J3V1B FTX25J3V1B FTX35J3V1B DAIKIN ROOM AIR CONDITIONER. Operation Manual

DAIKIN ROOM AIR CONDITIONER. Operation Manual ATXD60CV4 ATXD71CV4 ATXD80CV4

CONTENTS READ BEFORE OPERATION OPERATION CARE TROUBLE SHOOTING

OPERATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

DAIKIN ROOM AIR CONDITIONER. Operation Manual MODELS FTXS25EVMA FTKS25EVMA FTXS35EVMA FTKS35EVMA

DAIKIN ROOM AIR CONDITIONER FTXS50FVMA FTKS50FVMA FTXS60FVMA FTKS60FVMA FTXS71FVMA FTKS71FVMA FTXS80FVMA FTXS90FVMA MODELS.

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FDXS25LVMA FDXS35LVMA FDXS50LVMA FDXS60LVMA

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXB20C2V1B FTXB25C2V1B FTXB35C2V1B

Owner s Manual Super-Slim Four-Way Cassette

SYSTEM Inverter Air Conditioners

General safety precautions English

General safety precautions English

General safety precautions English

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

SYSTEM Inverter Air Conditioners

KSD-35 DR11 KUE-35 DVN11

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FVXS25KV1A FVXS35KV1A FVXS50KV1A FVXS35LV1A

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

MODELS FTX25KMV1B FTX35KMV1B DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXSQ36MVJU FXMQ36MVJU FXSQ48MVJU. MODELS Ceiling-mounted Duct type. Ceiling-mounted Built-in type

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

SYSTEM Inverter Air Conditioners

EDBE Heat Pump - SUPER MULTI H-Series

English DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL. Français. Español MODELS FDXS09LVJU FDXS12LVJU CDXS15LVJU CDXS18LVJU CDXS24LVJU

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

NEXXOS INVERTER USER MANUAL

OPERATION MANUAL. Split system air conditioners FCQG35FVEB FCQG50FVEB FCQG60FVEB FCQG71FVEB FCQG100FVEB FCQG125FVEB FCQG140FVEB

Owner s Manual. Fairwind Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL. Enjoy year-round comfort. MODELS FVXS25KV1A FVXS35KV1A FVXS50KV1A FVXS25RV1A FVXS35RV1A FVXS45RV1A

Bosch Split-Type Ductless Air Conditioner / Heat Pump

DAIKIN ROOM AIR CONDITIONER MODELS FTXS15DVJU FTXS18DVJU FTXS24DVJU. Operation Manual

General safety precautions English

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Inverter Split-type Room Air Conditioner

OPERATION MANUAL DAIKIN ROOM AIR CONDITIONER MODELS FTXN50KV1B FTXN60KV1B. English. Deutsch. Français. Nederlands. Español. Italiano.

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Operation manual. Split system air conditioners FBA35A2VEB FBA50A2VEB FBA60A2VEB FBA71A2VEB FBA100A2VEB FBA125A2VEB FBA140A2VEB

Table of Contents SAFETY FIRST. Owner s Manual. Safety Precautions Unit Specifications and Features Manual Operation (Without Remote)...

Owner s Manual CS

CPG*CA CPG*CD CGC*CA CGC*CD CIM*CA CIM*CD CPP*CA CPP*CD

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

General safety precautions English

General safety precautions English

Operation Manual FTXS42G2V1B DAIKIN ROOM AIR CONDITIONER. English. Deutsch. Français. Nederlands. Español. Italiano. ΕλληνικÜ. Portugues.

MODELS ATX20KV1B ATX25KV1B ATX35KV1B

OPERATION MANUAL. Split system air conditioners FHYBP71B8V1 FHYBP100B8V1 FHYBP125B8V1 FHYCP71B8V1 FHYCP100B8V1 FHYCP125B8V1

Operating Instructions

OPERATION MANUAL. VRV Classic System air conditioner RXYCQ8A7Y1B RXYCQ10A7Y1B RXYCQ12A7Y1B RXYCQ14A7Y1B RXYCQ16A7Y1B RXYCQ18A7Y1B RXYCQ20A7Y1B

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

OPERATION MANUAL. Split system air conditioners FDYP125B8V1 FDYP200B8V1 FDYP250B8V1 FDQ125B8V3B FDQ200B8V3B FDQ250B8V3B

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.

R410A SPLIT SERIES FIXED SPEED

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

OPERATION MANUAL. Air Conditioners FXAQ20PV1 FXAQ25PV1 FXAQ32PV1 FXAQ40PV1 FXAQ50PV1 FXAQ63PV1. MODELS Wall-mounted type. English. Deutsch.

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXAQ15PAV1 FXAQ20PAV1 FXAQ25PAV1 FXAQ32PAV1 FXAQ40PAV1 FXAQ50PAV1 FXAQ63PAV1

SPLIT - TYPE ROOM AIR CONDITIONER

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXLS25K3V1B FTXLS35K3V1B

Operating Instructions Air Conditioner

Air conditioner. User manual AC777KN4DCH

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

GDDEM10 DEHUMIDIFIER

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL

Operating Instructions Air Conditioner

SENA/09HF/IZ SENA/09HF/OZ SENA/12HF/IZ SENA/12HF/OZ SENA/18HF/IZ SENA/18HF/OZ SENA/24HF/IZ SENA/24HF/OZ

Operating Instructions Air Conditioner

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

SLIM CASSETTE TYPE AIR CONDITIONER OWNER S MANUAL

INVERTER SPLIT-TYPE ROOM AIR CONDITIONER

WIRED REMOTE CONTROLLER

Operating Instructions

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK

R410A SPLIT SERIES DC INVERTER QUICK COUPLING

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

Operating Instructions Air Conditioner

Middle Static Pressure Duct Type

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM150FC VAM250FC

PORTABLE AIR CONDITIONER

WIRED REMOTE CONTROLLER

English DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL. Français MODELS FTXG09HVJU FTXG12HVJU FTXG15HVJU

SPLIT SYSTEM Air Conditioners

AH-PNX11 AU-PNX11 AH-PNX14 AU-PNX14 EN-1 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ENGLISH

Operating Instructions Air Conditioner

Wireless Remote Controller Kit

OPERATING INSTRUCTIONS

Transcription:

DAIKIN ROOM AIR CONDITIONER Operation Manual FDXM25F2V1B FDXM50F2V1B FDXM35F2V1B FDXM60F2V1B

CONTENTS READ BEFORE OPERATION Safety precautions... 2 Names of parts... 4 CARE Care and Cleaning... 6 TROUBLE SHOOTING Troubleshooting... 8 The original instructions are written in English. All other languages are translations of the original instructions. 1

Safety precautions READ BEFORE OPERATION Keep this manual where the operator can easily find them. Read this manual attentively before starting up the unit. For safety reason the operator must read the following cautions carefully. This manual classifies precautions into WARNING and CAUTION. Be sure to follow all precautions below: they are all important for ensuring safety. The sound power is less than 70dB(A). Read the precautions in this manual carefully before operating the unit. This appliance is filled with R32. WARNING If you do not follow these instructions exactly, the unit may cause property damage, personal injury or loss of life. CAUTION If you do not follow these instructions exactly, the unit may cause minor or moderate property damage or personal injury. Never do. Be sure to earth the air conditioner. Never touch the air conditioner (including the remote controller) with a wet hand. WARNING Be sure to follow the instructions. Never cause the air conditioner (including the remote controller) to get wet. In order to avoid fire, explosion or injury, do not operate the unit when harmful, among which flammable or corrosive gases, are detected near the unit. It is not good for health to expose your body to the air flow for a long time. Do not put a finger, a rod or other objects into the air outlet or inlet. As the fan is rotating at a high speed, it will cause injury. Do not attempt to repair, relocate, modify or reinstall the air conditioner by yourself. Incorrect work will cause electric shocks, fire etc. For repairs and reinstallation, consult your Daikin dealer for advice and information. The refrigerant used in the air conditioner is safe. Although leaks should not occur, if for some reason any refrigerant happens to leak into the room, make sure it does not come in contact with any flame as of gas heaters, kerosene heaters or gas range. If the air conditioner is not cooling (heating) properly, the refrigerant may be leaking, so call your dealer. When carrying out repairs accompanying adding refrigerant, check the content of the repairs with our service staff. Do not attempt to install the air conditioner by your self. Incorrect work will result in water leakage, electric shocks or fire. For installation, consult the dealer or a qualified technician. In order to avoid electric shock, fire or injury, if you detect any abnormally such as smell of fire, stop the operation and turn off the breaker. And call your dealer for instructions. Depending on the environment, an earth leakage breaker must be installed. Lack of an earth leakage breaker may result in electric shocks or fire. The air conditioner must be earthed. Incomplete earthing may result in electric shocks. Do not connect the earth line to a gas pipe, water pipe, lightning rod, or a telephone earth line. 2

Safety precautions CAUTION In order to avoid any quality deterioration, do not use the unit for cooling precision instruments, food, plants, animals or works of art. Never expose little children, plants or animals directly to the air flow. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial and household use by lay persons. Do not place appliances which produce open fire in places exposed to the air flow from the unit or under the indoor unit. It may cause incomplete combustion or deformation of the unit due to the heat. Do not block air inlets nor outlets. Impaired air flow may result in insufficient performance or trouble. Do not stand or sit on the outdoor unit. Do not place any object on the unit to avoid injury, do not remove the fan guard. Do not place anything under the indoor or outdoor unit that must be kept away from moisture. In certain conditions, moisture in the air may condense and drip. After a long use, check the unit stand and fittings for damage. Do not touch the air inlet and alminum fins of outdoor unit. It may cause injury. This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children shall be supervised to ensure that they do not play with the appliance. To avoid oxygen deficiency, ventilate the room sufficiently if equipment with burner is used together with the air conditioner. Before cleaning, be sure to stop the operation, turn the breaker off or pull out the supply cord. Do not connect the air conditioner to a power supply different from the one as specified. It may cause trouble or fire. Arrange the drain hose to ensure smooth drainage. Incomplete draining may cause wetting of the building, furniture etc. Do not place things that must be kept dry under the indoor unit. Water may drip from the indoor unit if the humidity is 80% or above or when the drain outlet is clogged or the air-filter is dirtied. Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit. Leaves are a hotbed for small animals which can enter the unit. Once in the unit, such animals can cause malfunctions, smoke or fire when making contact with electrical parts. Do not operate the air conditioner with wet hands. Do not wash the indoor unit with excessive water, only use a slightly wet cloth. Do not place things such as vessels containing water or anything else on top of the unit. Water may penetrate into the unit and degrade electrical insulations, resulting in an electric shock. Installation site. To install the air conditioner in the following types of environments, consult the dealer. Places with an oily ambient or where steam or soot occurs. Salty environment such as coastal areas. Places where sulfide gas occurs such as hot springs. Places where snow may block the outdoor unit. The drain from the outdoor unit must be discharged to a place of good drainage. Consider nuisance to your neighbours from noises. For installation, choose a place as described below. A place solid enough to bear the weight of the unit which does not amplify the operation noise or vibration. A place from where the air discharged from the outdoor unit or the operation noise will not annoy your neighbours. Electrical work. For power supply, be sure to use a separate power circuit dedicated to the air conditioner. System relocation. Relocating the air conditioner requires specialized knowledge and skills. Please consult the dealer if relocation is necessary for moving or remodeling. 3

Names of parts Indoor Unit 1 2 4 3 OPTIONAL ACCESSORIES This indoor unit at least requires one of the remote controllers. Refer to the operation manual delivered with remote controller. Remote controller 4

Names of parts Outdoor Unit 5 6 9 7 8 Indoor Unit 1. Air outlet 2. Air outlet grille: (Field supply) Appearance of the Air outlet grille and Air inlet grille may differ with some models. 3. Suction grille: (Option) Appearance of the suction grille and Air inlet grille may differ with some models. 4. Air inlet Outdoor Unit 5. Air inlet: (Back and side) 6. Refrigerant piping and inter-unit cable 7. Drain hose The operation mode refers to the following table. Temperature Air flow Mode setting rate FDXM AUTO 25 C AUTO 8. Earth terminal: It is inside of this cover. 9. Air outlet Appearance of the outdoor unit may differ from some models. Please note If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF. Use the air conditioner in the following conditions. MODE Operating conditions If operation is continues out of this range Outdoor temperature: <2MXM> -10 46 C <3/4/5MXM> -10 46 C COOL Indoor temperature: 18 32 C Indoor humidity: 80% max. HEAT Outdoor temperature: <2/3/4/5MXM> -15 24 C Indoor temperature: 10 30 C A safety device may work to stop the operation. (In multi system, it may work to stop the operation of the outdoor unit only.) Condensation may occur on the indoor unit and drip. A safety device may work to stop the operation. Operation outside this humidity or temperature range may cause a safety device to disable the system. 5

Care and Cleaning CARE CAUTION Only a qualified service person is allowed to perform maintenance. Before cleaning, be sure to stop the operation and turn the breaker OFF. Cleaning the air filter 1.Removing the air filter. Rear suction Pull the bottom side of the air filter backwards, over the bends. (2 bends for 25/35 type, 3 bends for 50/60 type) Bottom suction Pull the filter over the bends (2 bends for 25/35 type, 3 bends for 50/60 type) situated at the backside of the unit. 2.Cleaning the air filter. Remove dust from the air filter using a vacuum cleaner and gently rinse them in cool water. Do not use detergent or hot water to avoid filter shrinking or deformation. After cleaning dry them in the shade. 3.Replacing the air filter. Rear suction Hook the filter behind the flap situated at the top of the unit and push the other side gently over the bends. (2 bends for 25/35 type, 3 bends for 50/60 type) Bottom suction Hook the filter behind the flap situated at the middle of the unit and push the other side gently over the bends. (2 bends for 25/35 type, 3 bends for 50/60 type) Main unit Filter Force Force Attach the filter to the main unit while pushing down on the bends. (2 bends for 25/35 type, 3 bends for 50/60 type) In case of back side In case of bottom side 6

Care and Cleaning Cleaning the drain pan Clean the drain pan periodically, or drain piping may be clogged with dust and may result in water leakage. Ask your DAIKIN dealer to clean them. Prepare a cover locally to prevent any dust in the air around the indoor unit from getting in the drain pan, if there is a great deal of dust present. CAUTION Do not operate the air conditioner without filters, this to avoid dust accumulation inside the unit. Do not remove the air filter except when cleaning. Unnecessary handling may damage the filter. Do not use gasoline, benzene, thinner, polishing powder, liquid insecticide, It may cause discoloring or warping. Do not let the indoor unit get wet. It may cause an electric shock or a fire. Operation with dusty air filters lowers the cooling and heating capacity and wastes energy. The suction grille is option. Do not use water or air of 50 C or higher for cleaning air filters and outside panels. Ask your DAIKIN dealer how to clean it. Check Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded. Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit. Check that the drain comes smoothly out of the drain hose during COOL or DRY operation. If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the service shop if this is the case. Before a long idle period 1. Operate the FAN only for several hours on a fine day to dry out the inside. Press MODE selector button and select FAN operation. Press ON/OFF button and start operation. 2. Clean the air filters and set them again. 3. Take out batteries from the remote controller. 4. Turn OFF the breaker for the room air conditioner. When a multi outdoor unit is connected, make sure the heating operation is not used at the other room before you use the fan operation. 7

Troubleshooting TROUBLE SHOOTING These cases are not troubles. The following cases are not air conditioner troubles but have some reasons. You may just continue using it. Case Operation does not start soon. When ON/OFF button was pressed soon after operation was stopped. When the mode was reselected. Hot air does not flow out soon after the start of heating operation. The heating operation stops suddenly and a flowing sound is heard. The outdoor unit emits water or steam. Mists come out of the indoor unit. Explanation This is to protect the air conditioner. You should wait for about 3 minutes. The air conditioner is warming up. You should wait for 1 to 4 minutes. (The system is designed to start discharging air only after it has reached a certain temperature.) The system is taking away the frost on the outdoor unit. You should wait for about 3 to 8 minutes. In HEAT mode The frost on the outdoor unit melts into water or steam when the air conditioner is in defrost operation. In COOL or DRY mode Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips. This happens when the air in the room is cooled into mist by the cold air flow during cooling operation. The indoor unit gives out odour. This happens when smells of the room, furniture, or cigarettes are absorbed into the unit and discharged with the air flow. (If this happens, we recommend you to have the indoor unit washed by a technician. Consult the service shop where you bought the air conditioner.) The outdoor fan rotates while the air conditioner is not in operation. The operation stopped suddenly. (OPERATION lamp is on.) After operation is stopped: The outdoor fan continues rotating for another 30 seconds for system protection. While the air conditioner is not in operation: When the outdoor temperature is very high, the outdoor fan starts rotating for system protection. For system protection, the air conditioner may stop operating on a sudden large voltage fluctuation. It automatically resumes operation in about 3 minutes. 8

Troubleshooting Check again. Please check again before calling a repair person. Case The air conditioner does not operate. (OPERATION lamp is off.) Cooling (Heating) effect is poor. Operation stops suddenly. (OPERATION lamp blinks.) An abnormal functioning happens during operation. Check Hasn t a breaker turned OFF or a fuse blown? Isn t it a power failure? Are batteries set in the remote controller? Is the timer setting correct? Are the air filters clean? Is there anything to block the air inlet or the outlet of the indoor and the outdoor units? Is the temperature setting appropriate? Are the windows and doors closed? Are the air flow rate and the air direction set appropriately? Are the air filters clean? Is there anything to block the air inlet or the outlet of the indoor and the outdoor units? Clean the air filters or take all obstacles away and turn the breaker OFF. Then turn it ON again and try operating the air conditioner with the remote controller. If the lamp still blinks, call the service shop where you bought the air conditioner. Are operation modes all the same for indoor units connected to outdoor units in the multi system? If not, set all indoor units to the same operation mode and confirm that the lamps blink. Moreover, when the operation mode is in AUTO, set all indoor unit operation modes to COOL or HEAT for a moment and check again that the lamps are normal. If the lamps stop blinking after the above steps, there is no malfunction. The air conditioner may malfunction with lightning or radio waves. Turn the breaker OFF, turn it ON again and try operating the air conditioner with the remote controller. 9

Troubleshooting Call the service shop immediately. WARNING When an abnormality (such as a burning smell) occurs, stop operation and turn the breaker OFF. Continued operation in an abnormal condition may result in troubles, electric shocks or fire. Consult the service shop where you bought the air conditioner. Do not attempt to repair or modify the air conditioner by yourself. Incorrect work may result in electric shocks or fire. Consult the service shop where you bought the air conditioner. If one of the following symptoms takes place, call the service shop immediately. The power cord is abnormally hot or damaged. An abnormal sound is heard during operation. The safety breaker, a fuse, or the earth leakage breaker cuts off the operation frequently. A switch or a button often fails to work properly. There is a burning smell. Water leaks from the indoor unit. Turn the breaker OFF and call the service shop. After a power failure The air conditioner automatically resumes operation in about 3 minutes. You should just wait for a while. Disposal requirements Your product and the batteries supplied with the controller are marked with this symbol. This symbol means that electrical and electronic products and batteries shall not be mixed with unsorted household waste. For batteries, a chemical symbol can be printed beneath the symbol. This chemical symbol means that the battery contains a heavy metal above a certain concentration. Possible chemical symbols are: Pb: lead (>0.004%) Lightning If lightning may strike the neighbouring area, stop operation and turn the breaker OFF for system protection. Do not try to dismantle the system yourself; the dismantling of the product, treatment of the refrigerant, of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legislation. Units and waste batteries must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring correct disposal, you will help to prevent potential negative consequences for environment and human health. Please contact the installer or local authority for more information. Dismantling of the unit, treatment of the refrigerant, of oil and of other parts must be done in accordance with relevant local and national legislation. We recommend periodical maintenance. In certain operating conditions, the inside of the air conditioner may get foul after several seasons of use, resulting in poor performance. It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user. For specialist maintenance, contact the service shop where you bought the air conditioner. The maintenance cost must be born by the user. Important information regarding the refrigerant used. Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information. 10