Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Similar documents
The Quality Connection. BETAflam Solar Photovoltaic power cables

Photovoltaic Cables EN H1Z2Z2-K

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

The Quality Connection. BETAflam Fire Resistant Safety Cables

Traction Cable Radox 3 GKW

The Quality Connection. BETAflam safety cables for highest demands

Single core cables with reduced wall thickness

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

The Quality Connection. BETAflam Safety cables for highest demands

Caledonian Flame Retardant Coaxial Cables

PRODUCT CATALOGUE Norröna

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

UNIKA Universal Cable Cable Specialist

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

High Performance LSZH Fire Resistant Cable

SOLARLOK Interconnection System Installation Manual

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Flexible Power Cable DLO

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Catalogue Power Cables

Cable technology for highest safety requirements

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Type approval qualification of Photovoltaic Modules Procedures and test experiences

The Quality Connection. BETAflam Fire safety cables

Flame Retardant Overall Screened Instrumentation Cables (multicore)

DNVGL-CP-0401 Edition February 2016

For Further information please visit our PSIDA DIY PVac640 fully integrated AC system

For Further information please visit our PSIDA DIY PVac500 fully integrated AC system

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Fire Risks and Safety Standards

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

S Low loss coax cables with foamed PE

DNVGL-CP-0399 Edition March 2016

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Here Comes the Sun!!!

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

Caledonian fire Resistant signal & Data cables

Caledonian Fire resistant Coaxial Cables

SOLAR CABLES. Electric cables for solar PV installations

Labeling to Article 690 of the National Electrical Code Routing and Protecting PV Cables

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Brand Portable Power Cord & Control Cable Solutions

Overmoulded Cable Assembly Selector Guide

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Compact Module. Category 6A FTP Cabling System 1.1

fire resistant cables

PHOTOVOLTAIC SYSTEMS

SECTION RADIANT-HEATING ELECTRIC CABLES / MATS

PERFORMANCE POLYMER SOLUTIONS

Catalogue Telecommunication Cables INTRODUCCIÓN

Heat Tracing Sales Mt. Airy, Maryland Heating Cable. Cut to Length in Field. Description

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

UV RESISTANT ACCORDING TO HD 605 RULE

LSOH Flexible Cables

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

Multi-Core Fire Resistant Cable

Introduction.

CONNECTION SYSTEMS TRANSIT APPLICATIONS

FIRE RESISTANT CABLES

CATALOG LIQUID-TUFF FLEXIBLE LIQUIDTIGHT CONDUIT CATALOG. Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit A PART OF

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

BS /1000V XLPE Insulation LSZH Sheath Cables

Frost Protection Thermostat

FIRST-CLASS IN TRAINS

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Product Information Motor and machine protection

SECTION RADIANT-HEATING ELECTRIC CABLES PART 1 - GENERAL 1.1 SECTIONS INCLUDES

FIRE RESISTANT CABLES FP300

OIL & GAS INDUSTRY OTHER INDUSTRIES

FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

Installation and Operation Manual

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Application Specification

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

SOLARLOK Interconnection System. RoHS. Ready

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

SPECIAL ELECTRICAL AND OPTICAL CABLES

Catalogue. Instrumentation & Control Cables

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

FlexLogic Slim. IP68 protected LED neon flex with a super-skinny illumination width of just 9mm. Product Brochure

Comtran Cable. Hub-LINK Cables for Transit Applications

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Transcription:

Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation. Approvals TÜV Rheinland 2 PfG 1169 08.2007 PV1-F Nr. R60040334 CSA C 22.2 No. 271-11 report No. 31281582 001, CU 72121476.01 UL 4703 09.2010 / PV Wire, UL 854 USE-2 07.2008, NEC NFPA 70 690.31A Application Applicable as photovoltaic wire for modules and connection to the inverter of grounded and ungrounded photovoltaic power systems. The high quality insulation components are offering UV and ozone protection at 90 C for more than 25 years. 1. STUDERCABLES.COM SWITZERLAND BETAFLAM SOLAR 125 FLEX UL 4703 3. 2. Construction 1. Conductor tinned fine copper strands according to VDE 0295/ IEC 60228, Cl. 5 2. Insulation white electron-beam cross-linked compound, flame retardant, halogen free 3. Jacket black electron-beam cross-linked compound, flame retardant, halogen free, UV and ozone resistant Dimensions Construction Article - Conductor Cond.-Ø Cable-Ø Resistance Weight Fire load Nr. Max. [n x mm²] [n x mm] [mm] [mm] mω/m [kg/km] [kwh/m] 1x 2.5 14 AWG 226243 45 x 0.25 2.05 6.50 +/-0.2 8.21 67 0.187 1x 4 12 AWG 224780 52 x 0.30 2.55 7.05 +/-0.2 5.09 86 0.213 1x 6 10 AWG 226135 78 x 0.30 3.10 7.60 +/-0.2 3.39 109 0.238 1x 10 8 AWG 302192 75 x 0.40 4.10 9.30 +/-0.2 1.95 155 0.340 Other dimensions upon request. Dated: 28.03.2011/KEW Leoni Studer AG www.leoni-solar-windpower.com Ae- Date: 20.08.2013 Ae-Index: 05 Datei: BETAflam Solar 125 flex UL 4703_E_Ae_05 Page 1 / 2

Technical Data Sheet BETAflam Solar 125 flex UL 4703 Labelling Cross Section STUDERCABLES.COM SWITZERLAND BETAFLAM SOLAR 125 FLEX UL 4703 600/1000 VAC 1 X MM2 TÜV PV1-F / E320250 USE-2 / E300485 PV WIRE AWG 90C WET OR DRY 600V SUN RES -40C (UL) RPV XL (ctuvus) AWG NR... Production Lot Number for internal purpose only. Subject to modifications. Technical Data Nominal voltage Test voltage U 0 /U 600 / 1000 V AC ; 1000 / 1800 V DC 6500 V AC 50Hz Temperature rating (20 000h) - 40 C up to + 125 C Ambient temperature > 25 years - 40 C up to + 90 C Max. short circuit temperature Min. bending radius 280 C, +536 F fixed installation 4 x Ø occasionally moved > 5 x Ø Material properties / Standards Design / Dimensions TÜV 2 PfG 1169 08.2007 PV1-F, CSA C 22.2 No. 271-11 UL 4703 09.2010 / PV WIRE, UL 854 USE-2 Halogen free IEC 60754-1 No corrosive gases IEC 60754-2 Flame retardant IEC 60332-1 / UL 1581 1060 / VW1 Low smoke emission IEC 61034; EN 50268-2 Low fire load DIN 51900 No hazardous and toxic substances Ozone resistant EU-Directive: RoHS 2002/95/EC; PAH 2005/69/EC; PFOS 2006/122/EC EN 50264-3-1 72h/40 C, process B Volume concentration 200x10-6 Material properties and technical data are subject to modifications. Dated: 28.03.2011/KEW Leoni Studer AG www.leoni-solar-windpower.com Ae- Date: 20.08.2013 Ae-Index: 05 Datei: BETAflam Solar 125 flex UL 4703_E_Ae_05 Page 2 / 2

Technical informations 25 Standard packaging / Technical information Current rating 120 C / 248 F Ambient temperature 30 C / 86 F Construction Exposed On surfaces without opposite contact On surfaces with opposite contact In conduit, casing, duct 1 1 mm2 A A A A 2.5 51 48 34 27 4 68 65 45 36 6 88 84 59 47 10 121 115 80 64 16 160 152 106 85 25 211 200 140 112 35 261 248 174 139 50 320 304 213 170 Continuous duty with current loads as per above table. This gives a conductor temperature of 120 C. (Calculation according IEC 60287) Conversion factors for deviating ambient temperatures (basis 30 C) Temperature Current rating at 120 C C Factor 20 1.05 30 1.00 40 0.94 50 0.88 60 0.82 70 0.75 80 0.67 90 0.58 05.2014 www.leoni-solar-windpower.com

BETAflam Solar 16 Module connection cables BETAflam Solar 125 RV flex FRNC Photovoltaic power cables, halogen free, flame retardant Advantages BETAflam Solar 125 RV flex FRNC Applications Double insulated, electron-beam cross-linked cables for photovoltaic power applications. With reduced diameter and integrated jacket. Construction Conductor Insulation Jacket Jacket colour Electrical characteristics Rated value Test voltage Tinned fine copper strands, acc. to VDE 0295 / IEC 60228, Class 5 XLPO, flame retardant, halogen free, electron-beam cross-linked XLPO, flame retardant, halogen free, electron-beam cross-linked, UV and ozone resistant black U 0 /U = 600 / 1000 V AC, 1000 / 1800 V DC 6500 V, 50 Hz, 5 min. Thermal characteristics Operating temperature Ambient temperature > 25 years (TÜV) Max. short circuit temp. 40 C up to +125 C 40 F up to +257 F 40 C up to +90 C 40 F up to +194 F 280 C, +536 F, 5 s Bending radius <10 mm >10 mm Fixed installation Occasionally moved Standards / Material properties > 4 > 5 > 5 > 7 Fire performance: IEC 60332-1, IEC 60332-3-24 Smoke emission: IEC 61034; EN 61034-2 Low fire load: DIN 51900 Approvals: TÜV 2 PfG 1169 08.2007 PV1-F Application standards: UNE 21123; UNE 20.460-5-52, UTE C 32-502 Electron-beam cross-linked compounds UV, ozone and hydrolysis resistant High temperature resistance, the materials do not melt or flow Very long service life > 25 years at 90 C Compatible to all popular connectors Flexible and space-saving installation www.leoni-solar-windpower.com 05.2014

BETAflam Solar 125 RV flex FRNC Module connection cables 17 BETAflam Solar Dimensions, weights Construction Marking Conductor Outer Resistance Weight Fire load Order no. n mm2 Colour mm mm max, mω/m kg/km kwh/m 1 2.5 white 2.05 4.65 8.21 41 0.079 304467 1 4 white 2.55 5.05 5.09 56 0.086 304468 1 6 white 3.10 5.65 3.39 76 0.100 304469 1 10 white 4.10 6.70 1.95 118 0.126 304471 1 16 white 5.50 9.70 1.24 211 0.288 304472 1 25 white 6.60 11.20 0.79 304 0.369 304474 1 35 white 7.70 12.30 0.56 404 0.414 304475 1 50 white 9.90 14.90 0.39 582 0.558 304476 1 2.5 red 2.05 4.65 8.21 41 0.079 307701 1 4 red 2.55 5.05 5.09 57 0.086 306470 1 6 red 3.10 5.65 3.39 77 0.100 306471 Order units Construction Marking Order no. n mm2 Farbe 50 100 m 24 500 m 18 500 m 18 1000 m 8 1000 m 1 4 white 304468V8 304468V1 304468V2 1 6 white 304469V8 304469V2 304469V3 1 10 white 304471V2 1 4 red 306470V1 306470V2 1 6 red 306471V2 306471V3 More information on the standard packaging unit see page 26. Further packaging units upon request. Bold printed order no. = stock item 05.2014 www.leoni-solar-windpower.com