Technical Data Sheet BETAflam Solar 125 flex UL 4703 Description Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation. Approvals TÜV Rheinland 2 PfG 1169 08.2007 PV1-F Nr. R60040334 CSA C 22.2 No. 271-11 report No. 31281582 001, CU 72121476.01 UL 4703 09.2010 / PV Wire, UL 854 USE-2 07.2008, NEC NFPA 70 690.31A Application Applicable as photovoltaic wire for modules and connection to the inverter of grounded and ungrounded photovoltaic power systems. The high quality insulation components are offering UV and ozone protection at 90 C for more than 25 years. 1. STUDERCABLES.COM SWITZERLAND BETAFLAM SOLAR 125 FLEX UL 4703 3. 2. Construction 1. Conductor tinned fine copper strands according to VDE 0295/ IEC 60228, Cl. 5 2. Insulation white electron-beam cross-linked compound, flame retardant, halogen free 3. Jacket black electron-beam cross-linked compound, flame retardant, halogen free, UV and ozone resistant Dimensions Construction Article - Conductor Cond.-Ø Cable-Ø Resistance Weight Fire load Nr. Max. [n x mm²] [n x mm] [mm] [mm] mω/m [kg/km] [kwh/m] 1x 2.5 14 AWG 226243 45 x 0.25 2.05 6.50 +/-0.2 8.21 67 0.187 1x 4 12 AWG 224780 52 x 0.30 2.55 7.05 +/-0.2 5.09 86 0.213 1x 6 10 AWG 226135 78 x 0.30 3.10 7.60 +/-0.2 3.39 109 0.238 1x 10 8 AWG 302192 75 x 0.40 4.10 9.30 +/-0.2 1.95 155 0.340 Other dimensions upon request. Dated: 28.03.2011/KEW Leoni Studer AG www.leoni-solar-windpower.com Ae- Date: 20.08.2013 Ae-Index: 05 Datei: BETAflam Solar 125 flex UL 4703_E_Ae_05 Page 1 / 2
Technical Data Sheet BETAflam Solar 125 flex UL 4703 Labelling Cross Section STUDERCABLES.COM SWITZERLAND BETAFLAM SOLAR 125 FLEX UL 4703 600/1000 VAC 1 X MM2 TÜV PV1-F / E320250 USE-2 / E300485 PV WIRE AWG 90C WET OR DRY 600V SUN RES -40C (UL) RPV XL (ctuvus) AWG NR... Production Lot Number for internal purpose only. Subject to modifications. Technical Data Nominal voltage Test voltage U 0 /U 600 / 1000 V AC ; 1000 / 1800 V DC 6500 V AC 50Hz Temperature rating (20 000h) - 40 C up to + 125 C Ambient temperature > 25 years - 40 C up to + 90 C Max. short circuit temperature Min. bending radius 280 C, +536 F fixed installation 4 x Ø occasionally moved > 5 x Ø Material properties / Standards Design / Dimensions TÜV 2 PfG 1169 08.2007 PV1-F, CSA C 22.2 No. 271-11 UL 4703 09.2010 / PV WIRE, UL 854 USE-2 Halogen free IEC 60754-1 No corrosive gases IEC 60754-2 Flame retardant IEC 60332-1 / UL 1581 1060 / VW1 Low smoke emission IEC 61034; EN 50268-2 Low fire load DIN 51900 No hazardous and toxic substances Ozone resistant EU-Directive: RoHS 2002/95/EC; PAH 2005/69/EC; PFOS 2006/122/EC EN 50264-3-1 72h/40 C, process B Volume concentration 200x10-6 Material properties and technical data are subject to modifications. Dated: 28.03.2011/KEW Leoni Studer AG www.leoni-solar-windpower.com Ae- Date: 20.08.2013 Ae-Index: 05 Datei: BETAflam Solar 125 flex UL 4703_E_Ae_05 Page 2 / 2
Technical informations 25 Standard packaging / Technical information Current rating 120 C / 248 F Ambient temperature 30 C / 86 F Construction Exposed On surfaces without opposite contact On surfaces with opposite contact In conduit, casing, duct 1 1 mm2 A A A A 2.5 51 48 34 27 4 68 65 45 36 6 88 84 59 47 10 121 115 80 64 16 160 152 106 85 25 211 200 140 112 35 261 248 174 139 50 320 304 213 170 Continuous duty with current loads as per above table. This gives a conductor temperature of 120 C. (Calculation according IEC 60287) Conversion factors for deviating ambient temperatures (basis 30 C) Temperature Current rating at 120 C C Factor 20 1.05 30 1.00 40 0.94 50 0.88 60 0.82 70 0.75 80 0.67 90 0.58 05.2014 www.leoni-solar-windpower.com
BETAflam Solar 16 Module connection cables BETAflam Solar 125 RV flex FRNC Photovoltaic power cables, halogen free, flame retardant Advantages BETAflam Solar 125 RV flex FRNC Applications Double insulated, electron-beam cross-linked cables for photovoltaic power applications. With reduced diameter and integrated jacket. Construction Conductor Insulation Jacket Jacket colour Electrical characteristics Rated value Test voltage Tinned fine copper strands, acc. to VDE 0295 / IEC 60228, Class 5 XLPO, flame retardant, halogen free, electron-beam cross-linked XLPO, flame retardant, halogen free, electron-beam cross-linked, UV and ozone resistant black U 0 /U = 600 / 1000 V AC, 1000 / 1800 V DC 6500 V, 50 Hz, 5 min. Thermal characteristics Operating temperature Ambient temperature > 25 years (TÜV) Max. short circuit temp. 40 C up to +125 C 40 F up to +257 F 40 C up to +90 C 40 F up to +194 F 280 C, +536 F, 5 s Bending radius <10 mm >10 mm Fixed installation Occasionally moved Standards / Material properties > 4 > 5 > 5 > 7 Fire performance: IEC 60332-1, IEC 60332-3-24 Smoke emission: IEC 61034; EN 61034-2 Low fire load: DIN 51900 Approvals: TÜV 2 PfG 1169 08.2007 PV1-F Application standards: UNE 21123; UNE 20.460-5-52, UTE C 32-502 Electron-beam cross-linked compounds UV, ozone and hydrolysis resistant High temperature resistance, the materials do not melt or flow Very long service life > 25 years at 90 C Compatible to all popular connectors Flexible and space-saving installation www.leoni-solar-windpower.com 05.2014
BETAflam Solar 125 RV flex FRNC Module connection cables 17 BETAflam Solar Dimensions, weights Construction Marking Conductor Outer Resistance Weight Fire load Order no. n mm2 Colour mm mm max, mω/m kg/km kwh/m 1 2.5 white 2.05 4.65 8.21 41 0.079 304467 1 4 white 2.55 5.05 5.09 56 0.086 304468 1 6 white 3.10 5.65 3.39 76 0.100 304469 1 10 white 4.10 6.70 1.95 118 0.126 304471 1 16 white 5.50 9.70 1.24 211 0.288 304472 1 25 white 6.60 11.20 0.79 304 0.369 304474 1 35 white 7.70 12.30 0.56 404 0.414 304475 1 50 white 9.90 14.90 0.39 582 0.558 304476 1 2.5 red 2.05 4.65 8.21 41 0.079 307701 1 4 red 2.55 5.05 5.09 57 0.086 306470 1 6 red 3.10 5.65 3.39 77 0.100 306471 Order units Construction Marking Order no. n mm2 Farbe 50 100 m 24 500 m 18 500 m 18 1000 m 8 1000 m 1 4 white 304468V8 304468V1 304468V2 1 6 white 304469V8 304469V2 304469V3 1 10 white 304471V2 1 4 red 306470V1 306470V2 1 6 red 306471V2 306471V3 More information on the standard packaging unit see page 26. Further packaging units upon request. Bold printed order no. = stock item 05.2014 www.leoni-solar-windpower.com