MECHANICAL VACUUM BOOSTERS:-

Similar documents
OPTIMISE VACUUM TO IMPROVE PLANT PERFORMNCE

Understanding Process Vacuum for Process Improvement

Vacuum Booster for Distillation Process

APPLICATION OF DRY SCREW VACUUM PUMPING SYSTEM IN VACUUM/PRESSURE IMPREGNATION PROCESS

Vacuum System Troubleshooting Author: Keith Webb, P.E. Application Engineering Manager

EMVO SINGLE STAGE OIL SEALED ROTARY VANE VACUUM PUMPS SUPERVANE (ROTARY VANE+BOOSTER COMBINATION VACUUM SYSTEMS)

Optimization of Hybrid Noncondensable Gas Removal System for a Flash Steam Geothermal Power Plant

DRY SCREW VACUUM PUMPS

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

PILOT-15 CENTRIFUGAL MOLECULAR DISTILLATION SYSTEM

Modern vacuum and overpressure generation for pneumatic conveying

Economical analysis between Vacuum system with ejectors and VS with liquid ring pump

Points to be Considered when Purchasing a Steam Jet Vacuum Pump

Prepared by Technical Team

CPF PRODUCT DESCRIPTION

Dry vacuum pumping is now well established

CPC PRODUCT DESCRIPTION

WHAT ARE THE SPECIFICATIONS FOR THE VACUUM

Vacuum Systems & Thin Films (Jaeger 6, Campbell 10&12, Ruska 7) Deposition of thin films involves vacuum system Direct Deposition from Source

The Experts in Vacuum Solutions

Vacuum and Compressor Systems for the Chemical Process Industry

POWERENERGY

CPVS PRODUCT DESCRIPTION

General. Applications and Accessories for Oil Diffusion Pumps. leybold. Application. Accessories LEYBOJET 630 DIP DIP DIP DIP 30000

Rotary evaporator RS 100 PRO

The Performance of Thermocompressors as Related to Paper Machine Dryer Drainage Systems

Root's Blowers. Introduction. Options to Choose from: RUTA Vacuum Systems. Root's Blower Vacuum Pumps. Industrial Series WAU Blower Hydrocarbon Oil

S-Series Screw. The nnovation. leader

Tuthill Vacuum & Blower Systems

Vacuum Systems & Thin Films (Jaeger 6, Campbell 10&12, Ruska 7) Deposition of thin films involves vacuum system Direct Deposition from Source

Liquid Ring Vacuum Pumps, Compressors and Systems

Mechanical Vacuum Systems for Secondary Metallurgy Steel Degassing

Reliable Vacuum Condenser Performance

On Balance: Heat Rejection Control a Packaged Solution

CENTRIFUGAL PUMPS. STATE the purposes of the following centrifugal pump components:

SPECIFICATIONS MODEL EHV X VACUUM OIL PURIFIER

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Rotary Evaporators. RE100-Pro. LCD Digital Rotary Evaporator. Features:

Lecture # 5: SOLVED PROBLEM

Adsorption Chillers Energysmart Green Cooling

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Intelligent. Evaporation. Premium Safety Standards Superior Ease of Use Reduced Cost of Ownership

SNOWCOOL SYSTEMS INDIA PVT LTD.

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

WESTERN HTDM 90+ OMEGA 91% & 95% EFFICIENT INDIRECT FIRED HEAT EXCHANGER UP TO 60:1 TURNDOWN HEAT ONLY & HEAT / COOL UNITS

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

SIHI dry Dry running vacuum pumps

Trouble Shooting Guide FAA, 3-phase (D3631)

Chapter 4 Compressors Overview & System Annual Power Consumption

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Figure 1. Ejector cross-sectional drawing. Figure 2. Precondenser to left of vacuum flasher. pressure.

Water Pumps. turbo-hydraulic pumps, positive-displacement pumps.

Refrigeration Technology in Building Services Engineering

Access Energy Thermapower Organic Rankine Cycle (ORC) Systems

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities

REFRIGERATION AND AIR CONDITIONING

edwardsvacuum.com VACUUM PUMPS EOSi ROTARY SCREW PUMP

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Superior Temperature Control. world of innovation

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

The pump. A pump is a device that moves fluids (liquids or gases), or sometimes slurries, by mechanical action.

Spool Compressor Technology Introduction

Bench-Top Vacuum Oven with 28 segments programmable controller

Trouble Shooting Guide PWA, 3-phase (D10571)

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Chapter-8 Capacity Control of Refrigeration Systems

Experience In Motion. SIHI LEMD Compact Liquid Ring Vacuum Pump

High Volume. Continuous. Optimal Performance. OPTI VACUUM STUFFING & PUMPING SYSTEMS

Modification of Condenser Nozzle and Cooling Tower Exit Screen to Increase Condenser Performance

Vacuum and Air Engineers Central Vacuum Systems. Dynavac VA C U U M & A I R S O L U T I O N S

745 Clark Ave. Bristol, CT Toll Free: Fax: General Air Dryer Installation Guidelines and Design Considerations

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

Variable Frequency Drive SERIES MP800 VFD

Rotary Evaporators, Heidolph

Roots TM Blowers, Compressors & Controls

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Optimization of Wire Vacuum

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

UNIT 4: REFRIGERATION PRINCIPLE

Vacuum in the laboratory. products and solutions

Vacuum Systems & Thin Films (Jaeger 6, Campbell 10&12, Ruska 7) Deposition of thin films involves vacuum system Direct Deposition from Source

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Trouble Shooting Guide RAA, 1-phase (D3627)

Superior Temperature Control. world of innovation

Helium Leak Detector The clever and modular Solution. Simple Operation. Top Performance.

Trouble Shooting Guide PAA, 1-phase (D3731)

Superior Temperature Control. world of innovation

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

Fundamentals of Hydronic Design

Section B Field Instruments

Intelligent. Evaporation.... no task too big

CHAPTER 4. HVAC DELIVERY SYSTEMS

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

CASE STUDY PAPER INDUSTRY

Transcription:

MECHANICAL VACUUM BOOSTERS:- Mechanical Vacuum Boosters are dry pumps that meet most of the ideal vacuum pump requirements. They work on positive displacement principle and are used to boost the performance of water ring /oil ring /rotating vane /piston pumps and steam or water ejectors. They are used in combination with any one of the above mentioned pumps, to overcome their limitations. Vacuum booster pumps offer very desirable characteristics which make them the most cost effective and power efficient option. The major advantages are:- (a) Can be integrated with any installed vacuum system such as Steam Ejectors, Water Ring Pumps, Oil Sealed Pumps, Water Ejectors, etc. (b) The vacuum booster is a Dry Pump as it does not use any pumping fluid. It pumps vapor or gases with equal ease. Small amounts of condensed fluid can also be pumped. (c) Vacuum boosters are power efficient. Very often a combination of Vacuum Booster and suitable backup pump results in reduced power consumption per unit of pumping speed. They provide high pumping speeds even at low pressures. (d) Boosters increase the working vacuum of the process, in most cases very essential for process performance and efficiency. Vacuum Booster can be used over a wide working pressure range, from 100 Torr down to 0.001 Torr (mm of mercury), with suitable arrangement of backup pumps.

(e) It has very low pump friction losses, hence requires relatively low power for high volumetric speeds. Typically, their speeds, at low vacuums are 20-30 times higher than corresponding vane pumps / ring pumps of equivalent power. (f) Use of electronic control devices such as Variable Frequency Control Drive allow to modify vacuum boosters operating characteristics to conform to the operational requirements of the prime vacuum pumps. Hence they can be easily integrated into all existing pumping set up to boost their performance. (g) Vacuum boosters don t have any valves, rings, stuffing box etc., therefore, do not demand regular maintenance. (h) Due to vapor compression action by the booster, the pressure at the discharge of booster (or inlet of backup pump) is maintained high, resulting in advantages such as low back streaming of prime pump fluid, effective condensation even at higher condenser temperatures and improvement of the backup pump efficiency. The Table below gives a rough estimate of how the boosters enhance the working vacuums of the processes when installed in combination with various types of industrial vacuum pumps currently used in the industry. They can effectively replace multistage steam ejectors, resulting in considerable steam savings and reduced loads on cooling towers. Mechanical Vacuum Boosters are versatile machines and their characteristics depend largely on backing pump. Various types of backing pump can be used, depending upon the system requirement and ultimate vacuum needs. However, the final vacuum is governed by the suitable selection of the backing pump and booster arrangement. The table below gives a broad range of vacuum achieved with various backing pumps combinations Vacuum Pump Expected vacuum Vacuum on installation Range of Booster (single stage) Single Stage Ejector 150 Torr 15 30 Torr Water Ejector 100 Torr 10 20 Torr Water Ring Pump 40 60 Torr 5 10 Torr Liquid Ring Pump 20 30 Torr 2 5 Torr Piston Pumps 20 30 Torr 2 5 Torr Rotary Piston Pumps 0.1 Torr 0.01 Torr Rotary Vane Oil Pump 0.01 0.001 Torr 0.001 0.0001 Torr.

For example, if a process is using water ring Pump, the estimated working vacuums would be of the order of about 670-710 mmhg gauge (90-50 mmhg abs.), largely depending on the water temperature and pump design. When a Booster is installed prior to the water ring pump, in series, the vacuum levels of the order of 5-10 Torr can be easily achieved. In a Multi-Stage booster installation, vacuum levels of the order of 0.5 Torr & better can easily be expected. Mechanical Boosters offer a completely dry pumping solution and do not add to any vapor load, unlike steam ejectors, and therefore, do not require large inter stage condenses. At low vacuums, higher pumping speeds are required to maintain the through-put, since the specific volume increases with the increase in vacuum. Vacuum boosters enhance the pumping speeds by about 3-10 times depending upon the selection by virtue of which one can expect higher process rates and through-puts. The drawbacks of steam ejector system such as sensitivity to motive fluid pressures and discharge pressure are overcome easily by the Mechanical Boosters, since the volumetric displacements/pumping speeds are insensitive to the inlet & outlet working pressures. Typical Booster Installation ( 1.) Evaporator ( 2) Gauge (3) Condenser ( 4) Mechanical Booster (5) backup Pump

Calculating the Pump Capacity: - Based on the fundamental gas laws PV= RT, an expression can be derived for Volumetric Flow Rates required for pumping different vapors/gases. Based on the Mass flow rates one can estimate the pump capacity required. V = R. Tgas / P Q 1 /M 1 + Q 2 /M 2. Q n /M n Where V = Inlet Volume flow rate m 3 /hr. R = Universal gas Constant, 83.14 mbar m 3 / Kgmol x ºK Tgas = Gas/Vapor abs. Temp, in ºK P = Process Absolute Pressure in mbar Q 1, Q 2, Q 3 = Gas / Vapor flow rate, in Kg/hr. M 1, M 2,M 3 = Molar mass, in Kg/mol. of gas /vapor. Booster Operation: Power Constraints restrict the total differential pressures across the booster. This demands to ensure the total differential pressure across the Booster must not exceed the rated limits. This can be ensured by any of the following means;- 1.) Manual method:- Initially the fore pump is switched on until the required cut in pressure is achieved and there-after the booster is switched on. 2.) Auto method:- Installation of mechanical By-pass arrangement across the booster or hydro kinematic drive or Variable Frequency Drive (VFD). In this arrangement, the booster and fore pump can be started simultaneously from atmosphere. Advantages of using Electronic Variable Speed Control Device Electronic A.C Variable Frequency Control Drives are most preferred devices used to regulate the Booster speed to match the varying load conditions of the process. These drives enhance the overall performance of the Boosters and offer various advantages for the trouble free operation. The major advantages are: - 1. Booster can be started directly from atmosphere.

2. No need for separate pressure switch, by pass line or offloading valves. 3. Considerable savings in power. 4. Prevents over-heating of Boosters. 5. Protects the Booster against overload and excessive pressures. 6. Offers complete protection to motor against over voltage, under voltage, over current, Over-heating, ground fault. 7. Eliminates the needs of separate starter and overload relays for the Motor. 8. Automatically adjusts the speed of Booster between low and high range set giving high pumping speeds with relatively low input power. The Electronic Variable Frequency Control Drive is a microprocessor based electronic drive which is specially programmed to meet the demands of the Booster allowing it to operate directly from atmosphere along with suitable fore pump. Conventionally, Boosters can be started only after achieving fore vacuum in the range of 30 100 Torr, as they are not recommended for direct discharge into the atmosphere. Use of Pressure Switch, Hydro kinematic drive and by pass valves is necessary to prevent the overloading of the Booster. However with the installation of Electronic Variable Frequency Control Drive all the conventional methods can be bypassed since the drive is programmed to regulate the Booster speed automatically, keeping the load on motor within permissible limits. This allows the Booster to start simultaneously with backup pump. When the backup-pump and Booster are started the drive reduces the Booster speed to the pre-set levels and as the vacuum is created the Booster speed picks up, reaching the final pre-set speed, giving most optimum performance over the entire range. Since all the parameters are easily programmable, one can adjust the booster pumping speeds to match the system requirements easily and quickly. The drive limits the current to the motor and safeguards the motor against over voltage, under voltage, electronic thermal, overheat ground fault. i.e. protects the motor against all possible faults. External computer control over all aspects of booster performance is possible via RS485 serial interface built into the drive electronics. This enables the Booster to be integrated into any computer-controlled operating system. (Article written by technical team of Everest Transmission The only successful manufacturer of Mechanical Vacuum Boosters in India) EVEREST TRANSMISSION B-44, Mayapuri Industrial Area, Phase-1, New Delhi-110064, India. Telefax: 91-11-28114944, 28114955, 28116307, 28117469 Email: info@everestblowers.com Web: www.everestblowers.com