Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Similar documents
Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

697C (60 HZ) Sizes 018 thru 060

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

A 14 SEER Heat Pump with R---410A Refrigerant Series

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

R4H4. Product Specifications

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

R4H4. Product Specifications

Product Data. Efficiency

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Product Data. Efficiency

Product Data. Efficiency. S S Reliability

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

N4H4. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

Product Data PA13NA PA13PA FEATURES AND BENEFITS

WCH5**4. Product Specifications

Product Data. controls Reliability S Puronr refrigerant - environmentally sound, won t

Advance Product Data

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Product Data. Efficiency

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

N4A6. Product Specifications

Product Data. S Sound level as low as 67 dba Comfort. S System supports Thermidistatt or standard thermostat controls Reliability

Product Data. Efficiency

Advance Product Data

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

R 410A Ducted Horizontal Air Conditioner

Product Data INDUSTRY LEADING FEATURES / BENEFITS

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Advance Product Data

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

WJH4 Product Specifications

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Advance Product Data

PAJ3. Product Specifications

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

TECHNICAL SPECIFICATIONS

2 shp 13 lc 1 36 t - 1 a

Product Data. FV4B Direct Expansion Variable Speed Fan Coil Puron Refrigerant. Sizes 002 thru 006

PAR5. Product Specifications

Installation Instructions

The First Family of Indoor Weather

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

TECHNICAL SPECIFICATIONS

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

TECHNICAL SPECIFICATIONS

Transcription:

Product Data Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant Sizes 024 thru 060 Carrier s technological leadership has risen to a new level with the development of the Performance Series 38YSP Heat Pump, the outdoor section of a superior split heat pump system. This leadership effort has yielded a product that appeals to consumers for all of its unique benefits. Puron, the environmentally sound refrigerant The first unique feature of the 38YSP is the environmentally sound nature of Puron refrigerant, which provides the homeowner with additional peace of mind because their heating and cooling system s refrigerant has zero ozone-depletion potential. Second, thanks to the performance advantage of Puron refrigerant, the 38YSP is extremely efficient. In fact, the 38YSP features some of the lowest energy usages of single speed heat pumps available from Carrier. Maximum performance and efficiency are made possible through the use of the FX4 and FV4 fan coils, custom made for Puron refrigerant applications. Third, the cost of service will potentially be reduced in the future as the industry s older refrigerant, R-22 is gradually phased out through Federally legislated production limitations. Carrier s Infinity Controls These industry-leading controls, when installed with Carrier s Ideal Humidity variable-speed furnaces or fan coils, provide the homeowner with: unparalleled control of temperature, humidity, indoor air quality, and zoning unprecedented ease of use simple operation through on-screen, text-based service reminders Copyright 2005 Carrier Corporation Form 38YSP-1PD

Optional remote access through telephone or Internet is also available when combined with a remote connectivity kit. FEATURES Silencer /Quiet Operation The Silencer features the Silencer top design, energy-efficient fan and motor, sound hood and discharge muffler. The Silencer Design top improves airflow patterns and requires less energy. The energy efficient fan and fan motor add to quiet operation while moving air more efficiently. The sound hood muffles noise from the operation. The discharge muffler minimizes low frequency sound and pressure pulsation generated by the compressor discharge gas. Compressor The 38YSP features a new and more efficient Copeland Scroll compressor, specially designed for Puron applications, with its thicker shell, and quiet shutdown device for superior reliability and quiet operation. In addition, each compressor is mounted on rubber isolators for additional sound reduction. For improved serviceability, all models are equipped with a compressor terminal plug. The scroll compressor will start under most system loads, thus eliminating the need for start assisting components. Continuous operation is approved down to -30 F (-34.4 C) in the heating mode and down to 55 F (12.8 C) in the cooling mode. (See heating and cooling performance tables.) The scroll compressor is covered with a standard 10-year limited warranty. Accumulator/Reliable Operation A properly sized accumulator which minimizes liquid refrigerant from reaching the compressor is standard on every unit. Reliable Built-In Components The 38YSP s principal feature of compressor protection is further enabled by a high pressure switch and a low pressure switch for loss of charge protection. Each unit also comes standard with a crankcase heater. Reliable operation is optimized with a quiet and easy to service reversing valve. A high filtration and moisture removing filter drier specially designed for Puron is shipped with every unit. Defrost Control Board This board incorporates a built-in 5-minute compressor time-delay relay, defrost relay, defrost timer, and low-voltage terminal board. The defrost control is a time/temperature initiation/ termination control which includes 4 field-selectable (DIP switch) time periods of 30, 60, 90, and 120 minutes. This control also includes a fieldselectable (DIP switch) Quiet Shift defrost mode which, if selected, maintains extremely quiet operation during defrost. Thermostatic Expansion Valve (TXV) This unit must be installed with a Puron TXV on the indoor coil. The FX4 and FV4 indoor fan coils and CK5P and CD5P furnace coils come factory equipped with a bi-flow Puron TXV. When installed in this application, no further change is required. If any other indoor fan coil or furnace coil is used, an accessory bi-flow Puron TXV must be installed. See accessory list in this publication for correct part number. The 024 size is equipped with a factory installed TXV for heating mode. Use indoor combinations listed in the Combination Ratings only. WeatherArmor III includes three components: The casing steel is galvanized and coated with a layer of zinc phosphate. A modified polyester powder coating is then applied and baked on, providing each unit with a hard, smooth finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting, rust-resistant, quality appearance. The coil is protected by an enhanced WeatherArmor heavy duty inlet grille. With spacing of 3/8-in. and construction of coated wire, the grille helps protect from inclement weather, vandalism, and incidental damage. It provides protection while not restricting airflow and maintaining ease of coil inspection and cleaning. Unit Design All units are equipped with totally enclosed fan motors for greater reliability under rain and snow conditions. The large, wraparound coil uses copper tubing and enhanced sine wave aluminum fins and is designed for optimum heat transfer during heating and cooling. The vertical air discharge carries the sound and air up and away from adjacent patio areas and foliage. Rows of composite coils can be cleaned with a common garden hose. External Service Valves Both service valves are the brass, back seating type with sweat connections. Each valve has a service port for ease of checking operating refrigerant pressures. The suction service port provides for ease of checking operating pressure in the heating mode. Limited Warranty Standard 5-year limited warranty on all parts, and 10-year limited warranty on the compressor. Model number nomenclature 38YSP 024 3 0 1 14 SEER Electric Heat Pump Nominal 024 24,000 Btu 042 42,000 Btu 030 30,000 Btu 048 48,000 Btu 036 36,000 Btu 060 60,000 Btu Electrical 3 208/230-1 Series Packaging 2 HEAT PUMP SYSTEM This heat pump can be part of a Comfort Heat Pump which can provide higher heating supply air temperatures, as well as up to 30 times more humidity removal in cooling mode. A Comfort Heat Pump requires the use of a Variable-Speed Fan Coil with Thermidistat Control, Comfort Zone II, or Infinity Control.

ISO 9001:2000 UNITARY HEAT PUMP REGISTERED MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 240 As an ENERGY STAR Partner, Carrier Corporation has determined that this product meets the ENERGY STAR guidelines * for energy efficiency. CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. *Refer to the combination ratings in the Product Data Digest for system combinations that meet Energy Star efficiency standards. Physical data UNIT SIZE-SERIES 024-30 030-30 036-30 042-30 048-30 060-30 OPERATING WEIGHT (Lb) 209 222 240 246 320 340 COMPRESSOR Type Scroll REFRIGERANT Puron (R-410A) Control TXV () Charge (Lb) @ 15 Ft 7.50 10.25 12.34 12.63 13.75 16.13 CONDENSER FAN Propeller Type, Direct Drive Air Discharge Vertical Air Quantity (CFM) 2000 2800 2800 2800 4000 4000 Motor HP 1/15 1/5 1/5 1/5 1/5 1/5 Motor RPM 800 825 825 825 825 825 CONDENSER COIL Copper Tube, Aluminum Plate Fin Face Area (Sq Ft) 18.25 15.21 18.25 18.25 20.74 24.89 Fins per In. 25 20 20 20 20 20 Rows 1 2 2 2 2 2 Circuits 3 4 4 4 5 5 VALVE CONNECTION (In. ID) Sweat Vapor 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8 Charge quantity is for 15 ft of interconnecting tubing. For tubing lengths other than 15 ft, see Residential Split s Long-Line Application Guideline for additional refrigerant requirements. NOTE: 1. See unit Installation Instructions for proper installation. UNIT SIZE RECOMMENDED TUBE DIAMETERS LIQUID TUBE DIAMETER (IN.) 0 to 50 Ft Tube Length 0 to 50 Ft Tube Length VAPOR TUBE DIAMETER (IN.) 0 to 50 ft Alternate 024 3/8 5/8 3/4 030 3/8 3/4 5/8, 7/8 036 3/8 3/4 5/8, 7/8 042, 048 3/8 7/8 3/4, 7/8 060 3/8 1-1/8 7/8 NOTES: 1. Tube diameters are for lengths up to 50 ft. For tubing lengths greater than 50 ft horizontal and/or 20 ft vertical differential, consult the Application Guideline and Service Manual for Residential Split- Air Conditioners and Heat Pumps using Puron Refrigerant. 2. Refrigerant tubes and indoor coils must be evacuated to 500 microns to minimize contamination and moisture in the system. METERING DEVICE UNIT SIZE OUTDOOR PISTON INDOOR TXV* REQUIRED SUBCOOLING ( F) 024 TXV KSATX0201PUR 11 030 55 KSATX0201PUR 9 036 57 KSATX0301PUR 9 042 61 KSATX0301PUR 9 048 63 KSATX0401PUR 8 060 73 KSATX0501PUR 8 * TXV must be installed when indoor coil is not equipped with a Puron approved TXV. TXV listed is for any approved coil combination. All TXVs are Puron specific bi-flow, hard shutoff. 3

Accessories ORDERING NUMBER DESCRIPTION KAATD0101TDR Time-Delay Relay All Sizes KSALA0301410 Low-Ambient Pressure Switch All Sizes KAAFT0101AAA Evaporator Freeze Thermostat All Sizes KHAIR0101AAA Isolation Relay All Sizes Not Available Ball-Bearing Fan Motor Size 024 HC38GE231 (RCD) Ball-Bearing Fan Motor Sizes 030 042 HC38GE232 (RCD) Ball-Bearing Fan Motor Sizes 048, 060 KSALA0401AAA* MotorMaster Low-Ambient Controller All Sizes KSAHS1701AAA Start Capacitor and Relay All Sizes KAACS0201PTC Start Assist PTC All Sizes Standard Crankcase Heater All Sizes KHAOT0301FST Outdoor Thermostat All Sizes KHAOT0201SEC Secondary Outdoor Thermostat All Sizes KSATX0201PUR Bi-Flow TXV (Hard Shutoff) Size 024, 030 KSATX0301PUR Bi-Flow TXV (Hard Shutoff) Sizes 036, 042 KSATX0401PUR Bi-Flow TXV (Hard Shutoff) Size 048 KSATX0501PUR Bi-Flow TXV (Hard Shutoff) Size 060 Standard Sound Hood All Sizes KHAPG0101PGS Pressure Guard Kit Sizes 024, 042 and 048 KHAPG0201PGS Pressure Guard Kit Sizes 030, 036 and 060 KH45LG140 (RCD) Filter Drier Suction Line Sizes 024 036 KH45LG141 (RCD) Filter Drier Suction Line Sizes 042 060 KHALS0401LLS Liquid-Line Solenoid Valve All Sizes KSASF0101AAA Support Feet 4 in. All Sizes KHASS0206MPK Snow Stand Sizes 024 042 KHASS0306MPK Snow Stand Sizes 048-060 KAACF0801MED Coastal Filter Sizes 024 042 KAACF0901LRG Coastal Filter Sizes 048 060 * Ball-bearing fan motor required. Must be applied on coils not equipped with Puron TXV. INFINITY * CONTROLS SYSTXCCUID01 SYSTXCCUIZ01 SYSTXCC4ZC01 SYSTXCCSMS01 SYSTXCCRRS01 SYSTXCCSAM01 SYSTXCCNIM01** SYSTXXXBPU01 * When applied with Carrier s IdealHumidity series 58MVP, 58CV(A,X) and FE Models. ** Must be installed in Dual-Fuel Infinity system applications. THERMOSTAT/SUBBASE PKG DESCRIPTION TSTATCCPRH01-B* Thermidistat Control Non-Programmable/Programmable Thermostat with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.) TSTATCCPDF01-B* Dual Fuel Thermostat Auto Changeover, 7-Day Programmable, F/ C, Includes Outdoor Sensor (TSTATXXSEN01-B) TSTATCCPHP01-B Thermostat Auto Changeover, 7-Day Programmable, F/ C, 2-Stage Heat/1-Stage Cool TSTATCCNHP01-C Thermostat Auto Changeover, Non-Programmable, F/ C, 2-Stage Heat/1-Stage Cool TSTATCCSHP01 Standard Programmable Thermostat Manual Changeover, 5-2 Day Programmable, F/ C, 1-Stage Heat/1-Stage Cool TSTATCCBHP01* Builder s Thermostat Heat Pump, Non-Programmable, F/ C, 2-Stage Heat/1-Stage Cool, Manual Changeover TSTATXXSEN01-B** Outdoor Air Temperature Sensor TSTATXXNBP01 Backplate for Non-Programmable Thermostat TSTATXXPBP01 Backplate for Programmable Thermostat and Thermidistat Control TSTATXXBBP01 Backplate for Builder s Thermostat TSTATXXSBP01 Backplate for Standard Programmable Thermostat TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 Wire) 10 Pack See notes on pg. 5. 4 DESCRIPTION Infinity Control Deluxe 7-Day Programmable (Wall-mounted system control.) Z Infinity Control Deluxe Zoning 7-Day Programmable (Wall-mounted control for a multi-zone system.) O N Infinity 4-Zone Damper Control Module (Wall-mounted control for a four-zone system.) I Infinity Smart Sensor (Optional wall control used to monitor temperature and/or fan control in an N individual zone.) G Infinity Remote Room Sensor (Monitors temperature in an individual zone.) Infinity Access Module (Hardware for wireless access and control via phone or internet.) Infinity Network Interface Module (Connects Heat Recovery and Energy Recovery Ventilators or older twospeed outdoor models to system.) Decorative Back Plate for Infinity Control (Decorative wall plate.)

* Do not use in zoning heat pump applications. This plate is designed to cover surrounding wall area located behind thermostat. Thermostat conversion kit is a 24-vac accessory that can turn a 4-wire thermostat application into a 5-wire application. This kit can also be used to replace a broken thermostat wire, or add an extra wire when needed. ** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non-programmable air conditioner version and builder s thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the dual fuel thermostat. The outdoor air temperature sensor is included with the Thermidistat Control and dual fuel thermostat. Accessory usage guideline ACCESSORY REQUIRED FOR LOW-AMBIENT APPLICATIONS (BELOW 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (OVER 50 FT) Crankcase Heater Yes Yes Evaporator Freeze Thermostat Yes No Compressor Start Assist Capacitor and Relay Yes Yes Puron Low Ambient Pressure Switch Yes No Wind Baffle See Low-Ambient Pressure Switch Instructions No Support Feet Recommended No Puron Hard Shutoff TXV Yes Yes Puron Liquid-Line Solenoid Valve for * For tubing line sets between 50 and 175 ft horizontal and/or 20 ft vertical differential, elevation difference between indoor and outdoor units, refer to the Application Guideline and Service Manual for Residential Split- Air Conditioners and Heat Pumps using Puron Refrigerant. Required for all applications. Standard on all units. Accessory description and usage (Listed alphabetically) 1. Ball-Bearing Fan Motor A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication. Required on all units when MotorMaster Low-Ambient Controller is installed. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. 3. Compressor Start Assist Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Note: Heat pumps with Puron-refrigerant and a reciprocating compressor have capacitor and relay factory supplied. Required for single-phase reciprocating compressors in the following applications: Long line Low ambient cooling Hard shut off expansion valve on indoor coil Required for single-phase scroll compressors in the following applications: Long line Low ambient cooling Suggested for all compressors in areas with a history of low voltage problems. 4. Compressor Start Assist PTC Type Solid state electrical device which gives a "soft" boost to the compressor at each start-up. Suggested in installations with marginal power supply. 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Note: Some heat pumps are factory supplied with a crankcase heater. See accessory list for units that come standard with a crankcase heater. For units that do not, use the guideline below. Required in low ambient cooling applications. Required in long line applications. Suggested in all commercial applications. 6. Evaporator Freeze Thermostat An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Required when low ambient kit has been added. 7. Isolation Relay An SPDT relay which switches the low-ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode. Required in all heat pumps where low ambient kit has been added. 8. Liquid-Line Solenoid Valve (LLS) An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode. An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Application Guideline. 5 No See Long-Line Application Guideline

Accessory description and usage (Listed alphabetically) continued 9. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 200 psig to 365 psig). The control will maintain working head pressure at low-ambient temperatures down to 0 F ( 17.8 C) when properly installed. A Low-Ambient Pressure Switch or MotorMaster Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55 F (12.8 C). 10. MotorMaster Low-Ambient Controller A fan-speed control device activated by a temperature sensor designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F ( 28.9 C), it maintains condensing temperature at 100 F ± 10 F (37.8 C ± 12 C). A MotorMaster Low-Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55 F (12.8 C). Suggested for all commercial applications 11. Outdoor Air Temperature Sensor Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Suggested for all Carrier thermostats listed in this publication. 12. Outdoor Thermostat An SPDT temperature-actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user-selected set point. Electric supplemental heat applications in non-variable-speed indoor units when electric heat staging is desired. 13. Pressure Guard Kit A pressure switch kit that cycles the outdoor fan to limit the heating head pressure below a pre-determined pressure setting. Some local codes may require limiting the heating head pressure in the vapor line in some applications. 14. Secondary Outdoor Thermostat An SPDT temperature-actuated switch which turns on third-stage of supplemental electric heaters when outdoor air temperature drops below the second-stage set point. Outdoor thermostat applications where electric heater is capable of 3-stage operation. 15. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dba. Suggested when unit is installed closer than 15 ft to quiet areas bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft apart. 16. Snow Stand Coated wire rack which supports unit 18 in. above mounting pad to allow for drainage from unit base. Suggested in the following applications: Heat pump installations in heavy snowfall areas. Heat pump installations in snowdrift locations. Heat pump installations in areas of prolonged subfreezing temperatures. All commercial installations. 17. Support Feet Four stick-on plastic feet that raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion. Suggested in the following applications: Coastal installations. Windy areas or where debris is normally circulating. Rooftop installations. For improved sound ratings. 18. Thermostatic Expansion Valve (TXV) Bi-Flow A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Required in all heat pump applications designed with Puron refrigerant. 19. Time-Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. Note: Most indoor unit controls include this feature. For those that do not, use the guideline below. For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. 6

Electrical data UNIT SIZE- SERIES V-PH OPER VOLTS* COMPR Max Min LRA RLA * Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. Time-delay fuse or Circuit Breaker. Length shown is as measured 1 way along the wire path between the unit and the service panel for voltage drop not to exceed 2%. ** If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. If other than uncoated (non-plated), 60 or 75 C (140 or 167 F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70). FLA Full Load Amps LRA Locked Rotor Amps MCA Minimum Circuit Amps RLA Rated Load Amps NOTE: Control circuit is 24v on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection. FAN FLA MCA MIN WIRE SIZE 60 C/75 C** MAX LENGTH (Ft) 60 C/75 C MAX FUSE OR CKT BKR AMPS 024-30 58.3 12.8 0.5 16.5 14/14 46/44 25 030-30 73.0 14.1 1.1 18.7 14/14 41/39 30 036-30 79.0 17.9 1.1 23.5 12/12 52/50 40 208/230-1 253 197 042-30 112.0 20.0 1.1 26.2 10/10 77/73 40 048-30 117.0 25.1 1.4 32.8 8/10 94/58 50 060-30 134.0 29.7 1.4 38.5 8/8 80/76 60 A-weighted sound power (dba) UNIT SIZE- STANDARD TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) SERIES RATING 125 250 500 1000 2000 4000 8000 24-30 67 53.5 57.0 60.5 60.0 57.5 55.5 47.0 30-30 71 57.5 62.0 66.0 65.0 64.5 59.5 50.0 36-30 71 57.0 61.5 65.0 64.5 64.0 59.5 53.0 42-30 73 57.5 61.5 65.0 67.0 66.0 60.5 53.0 48-30 76 62.5 67.5 70.5 71.0 68.5 62.5 55.0 60-30 76 60.5 67.0 70.0 69.5 68.0 61.5 56.0 NOTE: Tested in accordance with ARI Standard 270-95. (Not listed with ARI.) 7

Dimensions NOTES: 1. Allow 30 in. clearance to service side of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. 2. Minimum outdoor operating ambient in cooling mode is 55 F (unless low ambient control is used) max 125 F. 3. 4. 5. Maximum outdoor operating ambient in heating mode is 66 F. Series designation is the 13th position of the unit model number. Center of gravity. AIR DISCHARGE L AIR IN H DIA VAPOR LINE CONN FIELD POWER SUPPLY CONN 7/8 IN. DIA HOLE WITH 1 1/8 IN. DIA KNOCKOUT C AND 3/8 IN. DIA TIEDOWN AIR DISCHARGE 2 1/2" 1 3/8 IN. DIA KNOCKOUT KNOCKOUTS (2) PLACES IN BASEPAN 1 9/16" B AIR IN C L D E K FIELD CONTROL SUPPLY CONN 7/8 IN. DIA HOLE 3/8 IN. DIA. LIQUID LINE CONN 10 1/2" F G A ACCESS PANEL M 4 3/16" AIR DISCHARGE AIR IN J 1 3/4" 1 1/4" 2 15/16" A99087 DIMENSIONS (IN.) UNIT SIZE SERIES MINIMUM MOUNTING UNIT DIMENSIONS PAD DIMENSIONS A B C D E F G H J K L M Support Feet Snow Stand 024 0 39-13/16 30 34-15/16 4 9-3/4 27-1/2 33-7/8 5/8 8-3/16 15-7/8 14-3/8 14-1/4 26 x 32 31 x 35 030 0 33-13/16 30 34-15/16 4 9-3/4 21-1/2 27-7/8 3/4 8-3/16 14 13-1/8 14 26 x 32 31 x 35 036 0 39-13/16 30 34-15/16 4 9-3/4 27-1/2 33-7/8 3/4 8-3/16 16-1/8 14-1/8 14-1/2 26 x 32 31 x 35 042 0 39-13/16 30 34-15/16 4 9-3/4 27-1/2 33-7/8 7/8 8-3/16 16-1/4 14-1/4 14-1/2 26 x 32 31 x 35 048 0 33-13/16 38-5/8 45 5-5/16 11-3/16 21-1/2 27-7/8 7/8 8-9/16 19-1/2 25-1/2 15-1/2 32 x 42 36 x 46 060 0 39-13/16 38-5/8 45 5-5/16 11-3/16 27-1/2 33-7/8 7/8 8-9/16 19-7/8 26 17 32 x 42 36 x 46 8

BUILDING HEAT LOSS, UNIT INTEGRATED HEATING CAPACITY, MBTUH 80 70 60 50 40 30 20 10 0 38YSP BALANCE POINT WORKSHEET 38YSP06030 FV4BNB006 38YSP04830 FV4BNB006 38YSP04230 FV4BNF005 38YSP03630 FV4BNF005 38YSP03030 FV4BNF003 38YSP02430 FV4BNF002 BASED ON INDOOR ENT. AIR AT 70 F AND AT RATED CFM -10 0 10 20 30 40 50 60 70 80 OUTDOOR TEMPERATURE, F A05008 0.0 2.9 5.9 8.8 11.7 kw 14.6 17.6 20.5 23.4 9

Combination ratings* UNIT SIZE- SERIES 024-30 030-30 See notes on pg. 15. 10 INDOOR UNIT TC Factory- Supplied Enhancement Seasonal Efficiency SEER Standard Rating Puron TXV ARI STANDARD RATINGS* Field-Supplied Accessory High-Temp Low-Temp Puron TXV & TDR** TDR EER TC COP TC COP *FV4BNF002 22,600 TDR&TXV 15.50 12.4 24,000 3.84 14,900 2.68 9.0 CC5A/CD5AA036 22,000 NONE 13.50 11.05 23,400 3.44 15,100 2.44 8.0 CC5A/CD5AW036 22,000 NONE 13.50 11.05 23,400 3.44 15,100 2.46 8.0 CE3AA036 21,800 NONE 13.20 10.95 23,600 3.36 15,200 2.38 8.0 CK3BA036 22,000 NONE 13.50 11.10 23,400 3.54 15,200 2.46 8.0 CK5A/CK5BA036 22,000 NONE 13.50 11.10 23,000 3.54 15,200 2.46 8.0 CK5A/CK5BT036 22,000 NONE 13.50 11.10 23,000 3.54 15,200 2.46 8.0 CK5A/CK5BW036 22,000 NONE 13.50 11.10 23,000 3.54 15,200 2.46 8.0 CK5PA036 22,000 TXV 13.50 11.10 23,000 3.54 15,200 2.46 8.0 CK5PT036 22,000 TXV 13.50 11.10 23,000 3.54 15,200 2.46 8.0 CK5PW036 22,000 TXV 13.50 11.10 23,000 3.54 15,200 2.46 8.0 FE4ANF002 22,600 TDR&TXV 15.50 12.45 24,000 3.82 14,900 2.66 9.0 FE4ANF003 22,600 TDR&TXV 15.50 12.60 23,600 3.82 14,700 2.68 9.0 FV4BNF003 22,600 TDR&TXV 15.50 12.60 23,600 3.82 14,700 2.68 9.0 FX4BNF030 22,400 TDR&TXV 13.50 11.15 24,000 3.64 15,500 2.44 8.5 COILS + 58CV(A,X)070-12 VARIABLE-SPEED FURNACE CC5A/CD5AA036 22,000 TDR 15.00 12.20 23,000 3.58 14,600 2.58 8.5 CK3BA036 22,000 TDR 15.00 12.25 23,000 3.68 14,700 2.58 8.5 CK5A/CK5BA036 22,000 TDR 15.00 12.30 23,000 3.68 14,700 2.60 8.5 COILS + 58CV(A,X)090-16 VARIABLE-SPEED FURNACE CC5A/CD5AA036 22,000 TDR 15.00 12.35 23,000 3.62 14,600 2.60 8.5 CK3BA036 22,000 TDR 15.00 12.40 23,000 3.72 14,700 2.60 8.5 CK5A/CK5BA036 22,000 TDR 15.00 12.40 23,000 3.72 14,700 2.62 8.5 COILS + 58CV(A,X)110-20 VARIABLE-SPEED FURNACE CC5A/CD5AA036 22,000 TDR 15.00 12.30 23,000 3.62 14,600 2.60 8.5 CK3BA036 22,000 TDR 15.00 12.35 23,000 3.72 14,700 2.60 8.5 CK5A/CK5BA036 22,000 TDR 15.00 12.35 23,000 3.72 14,700 2.60 8.5 COILS + 58MVP060-14 VARIABLE-SPEED FURNACE CC5A/CD5AA036 22,000 TDR 15.00 12.25 23,000 3.60 14,600 2.58 8.5 CK5A/CK5BA036 22,000 TDR 15.00 12.30 23,000 3.70 14,700 2.60 8.5 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE CC5A/CD5AA036 22,000 TDR 15.00 12.20 23,000 3.62 14,600 2.58 8.5 CK5A/CK5BA036 22,000 TDR 15.00 12.30 23,000 3.70 14,800 2.60 8.5 COILS + 58MVP080-20 VARIABLE-SPEED FURNACE CC5A/CD5AA036 22,000 TDR 15.00 12.25 23,000 3.62 14,600 2.58 8.5 CK5A/CK5BA036 22,000 TDR 15.00 12.30 23,000 3.70 14,700 2.60 8.5 COILS + 58MVP100-20 VARIABLE-SPEED FURNACE CC5A/CD5AA036 22,000 TDR 15.00 12.30 23,000 3.64 14,600 2.60 8.5 CK5A/CK5BA036 22,000 TDR 15.00 12.35 23,000 3.72 14,700 2.60 8.5 *FV4BNF003 28,000 TDR&TXV 15.50 13 29,000 3.84 17,200 2.62 9.0 CC5A/CD5AA030 26,400 NONE 13.00 11.15 29,000 3.38 17,800 2.36 8.0 CC5A/CD5AA036 26,800 NONE 13.70 11.50 29,400 3.60 18,000 2.44 8.5 CC5A/CD5AW030 26,400 NONE 13.00 11.15 29,000 3.38 17,800 2.36 8.0 CC5A/CD5AW036 26,800 NONE 13.70 11.50 29,400 3.60 18,000 2.44 8.5 CE3AA030 27,000 NONE 13.00 11.25 29,000 3.54 18,000 2.42 8.0 CE3AA036 27,200 NONE 13.50 11.35 29,400 3.56 18,000 2.42 8.4 CK3BA030 26,800 NONE 13.00 11.20 29,000 3.54 18,000 2.42 8.0 CK3BA036 27,200 NONE 13.70 11.50 29,400 3.70 18,100 2.48 8.5 CK5A/CK5BA030 26,800 NONE 13.00 11.20 29,000 3.54 18,000 2.42 8.0 CK5A/CK5BA036 27,400 NONE 13.70 11.55 29,400 3.70 18,100 2.48 8.5 CK5A/CK5BT036 27,400 NONE 13.70 11.55 29,400 3.70 18,100 2.48 8.5 CK5A/CK5BW030 26,800 NONE 13.00 11.20 29,000 3.54 18,000 2.42 8.0 CK5A/CK5BW036 27,400 NONE 13.70 11.55 29,400 3.70 18,100 2.48 8.5 CK5PA030 26,800 TXV 13.00 11.20 29,000 3.54 18,000 2.42 8.0 CK5PA036 27,400 TXV 13.70 11.55 29,400 3.70 18,100 2.48 8.5 CK5PT036 27,400 TXV 13.70 11.55 29,400 3.70 18,100 2.48 8.5 CK5PW030 26,800 TXV 13.00 11.20 29,000 3.54 18,000 2.42 8.0 CK5PW036 27,400 TXV 13.70 11.55 29,400 3.70 18,100 2.48 8.5 F(A,B)4BN(F,C)030 27,000 TDR 13.20 11.45 29,800 3.50 17,900 2.44 8.5 F(A,B)4BN(F,C)036 27,000 TDR 13.50 11.25 30,000 3.50 18,200 2.42 8.5 FE4ANF002 28,000 TDR&TXV 15.50 12.70 29,000 3.84 17,300 2.60 9.0 FE4ANF003 28,000 TDR&TXV 15.50 13.00 29,000 3.84 17,100 2.60 9.0 FE4ANF005 28,600 TDR&TXV 16.00 13.45 29,200 4.04 17,300 2.70 9.5 FK4DNF002 28,000 TDR&TXV 15.00 12.70 29,000 3.84 17,300 2.60 9.0 FK4DNF003 28,000 TDR&TXV 15.50 13.00 29,000 3.82 17,100 2.60 9.0 FK4DNF005 28,600 TDR&TXV 16.00 13.45 29,200 4.04 17,300 2.70 9.5 FV4BNF002 28,000 TDR&TXV 15.00 12.70 29,000 3.84 17,300 2.60 9.0 FV4BNF005 28,600 TDR&TXV 16.00 13.45 29,200 4.04 17,300 2.70 9.5 HSPF

Combination ratings* continued UNIT SIZE- SERIES 030-30 036-30 See notes on pg. 15. INDOOR UNIT TC Factory- Supplied Enhancement Seasonal Efficiency SEER Standard Rating Puron TXV ARI STANDARD RATINGS* Field-Supplied Accessory High-Temp Low-Temp Puron TXV & TDR** TDR EER TC COP TC COP FX4BNF030 27,000 TDR&TXV 14.00 11.60 29,400 3.58 17,700 2.44 8.7 FX4BNF036 27,200 TDR&TXV 13.70 11.55 29,600 3.60 17,800 2.44 8.7 COILS + 58CV(A,X)070-12 VARIABLE-SPEED FURNACE CC5A/CD5AA036 27,400 TDR 15.00 12.45 28,600 3.62 17,100 2.50 8.7 CK3BA036 27,400 TDR 15.00 12.55 29,000 3.72 17,300 2.54 8.7 CK5A/CK5BA036 27,400 TDR 15.00 12.55 28,600 3.72 17,300 2.54 8.7 COILS + 58CV(A,X)090-16 VARIABLE-SPEED FURNACE CC5A/CD5AA036 27,400 TDR 15.00 12.70 28,600 3.64 17,000 2.52 9.0 CK3BA036 27,400 TDR 15.00 12.70 29,000 3.74 17,200 2.56 8.7 CK5A/CK5BA036 27,400 TDR 15.00 12.75 28,600 3.74 17,200 2.56 9.0 COILS + 58CV(A,X)110-20 VARIABLE-SPEED FURNACE CC5A/CD5AA036 28,000 TDR 15.00 12.55 29,400 3.82 17,600 2.58 9.0 CK3BA036 27,400 TDR 15.00 12.70 29,000 3.76 17,200 2.58 8.7 CK5A/CK5BA036 27,400 TDR 15.00 12.70 28,600 3.76 17,200 2.58 9.0 COILS + 58MVP060-14 VARIABLE-SPEED FURNACE CC5A/CD5AA036 28,000 TDR 15.00 12.45 29,400 3.78 17,600 2.56 9.0 CK3BA036 27,400 TDR 15.00 12.60 29,000 3.72 17,200 2.54 8.7 CK5A/CK5BA036 27,400 TDR 15.00 12.60 28,600 3.72 17,200 2.54 8.7 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE CC5A/CD5AA036 28,000 TDR 14.50 12.15 29,400 3.72 17,700 2.52 9.0 CK3BA036 27,400 TDR 15.00 12.55 29,000 3.72 17,300 2.56 8.7 CK5A/CK5BA036 27,400 TDR 15.00 12.55 28,600 3.72 17,300 2.56 9.0 COILS + 58MVP080-20 VARIABLE-SPEED FURNACE CC5A/CD5AA036 28,000 TDR 14.70 12.40 29,400 3.78 17,600 2.56 9.0 CK3BA036 27,400 TDR 15.00 12.60 29,000 3.72 17,200 2.56 8.7 CK5A/CK5BA036 27,400 TDR 15.00 12.55 28,600 3.72 17,300 2.56 8.7 COILS + 58MVP100-20 VARIABLE-SPEED FURNACE CC5A/CD5AA036 27,400 TDR 15.00 12.60 28,600 3.64 17,100 2.52 8.7 CK3BA036 27,400 TDR 15.00 12.65 29,000 3.74 17,200 2.56 9.0 CK5A/CK5BA036 27,400 TDR 15.00 12.65 28,600 3.74 17,200 2.56 9.0 *FV4BNF005 35,000 TDR&TXV 16.00 13 36,000 3.88 22,200 2.78 9.5 CC5A/CD5AA036 33,200 NONE 13.20 11.20 36,000 3.46 23,000 2.52 8.2 CC5A/CD5AA042 33,200 NONE 13.50 11.20 36,000 3.46 23,000 2.52 8.2 CC5A/CD5AW036 33,200 NONE 13.20 11.20 36,000 3.46 23,000 2.52 8.2 CC5A/CD5AW042 33,000 NONE 13.20 11.05 36,000 3.36 22,800 2.46 8.0 CE3AA036 33,000 NONE 13.00 11.05 36,000 3.40 23,000 2.48 8.2 CE3AA042 33,400 NONE 13.50 11.25 36,000 3.52 23,000 2.54 8.5 CK3BA036 33,200 NONE 13.20 11.20 36,000 3.54 23,200 2.56 8.2 CK3BA042 33,200 NONE 13.50 11.20 36,000 3.54 23,200 2.56 8.2 CK5A/CK5BA036 33,000 NONE 13.20 11.20 36,000 3.54 23,200 2.56 8.2 CK5A/CK5BA042 33,200 NONE 13.50 11.20 36,000 3.54 23,200 2.56 8.2 CK5A/CK5BE042 33,400 NONE 13.50 11.25 36,000 3.60 23,200 2.58 8.2 CK5A/CK5BT036 33,200 NONE 13.20 11.20 36,000 3.54 23,200 2.56 8.2 CK5A/CK5BT042 33,200 NONE 13.50 11.20 36,000 3.54 23,200 2.56 8.2 CK5A/CK5BW036 33,200 NONE 13.20 11.20 36,000 3.54 23,200 2.56 8.2 CK5PA036 33,200 TXV 13.20 11.20 36,000 3.54 23,200 2.56 8.2 CK5PA042 33,200 TXV 13.50 11.20 36,000 3.54 23,200 2.56 8.2 CK5PE042 33,400 TXV 13.50 11.25 36,000 3.60 23,200 2.58 8.2 CK5PT036 33,200 TXV 13.20 11.20 36,000 3.54 23,200 2.56 8.2 CK5PT042 33,200 TXV 13.50 11.20 36,000 3.54 23,200 2.56 8.2 CK5PW036 33,200 TXV 13.20 11.20 36,000 3.54 23,200 2.56 8.2 F(A,B)4BN(F,B,C)042 33,400 TDR 13.00 11.00 36,000 3.50 23,200 2.52 8.2 FC4CNB054 35,000 TDR&TXV 14.00 11.95 36,000 3.92 23,400 2.68 9.0 FE4ANB006 35,200 TDR&TXV 16.20 13.30 36,000 4.02 22,200 2.82 9.5 FE4ANF005 35,000 TDR&TXV 16.00 13.00 36,000 3.90 22,200 2.78 9.5 FK4DNB006 35,200 TDR&TXV 16.20 13.30 36,000 4.02 22,200 2.82 9.5 FK4DNF005 35,000 TDR&TXV 16.00 13.00 36,000 3.90 22,200 2.78 9.5 FV4BNB006 35,200 TDR&TXV 16.20 13.30 36,000 4.00 22,200 2.82 9.5 FX4BNF036 33,400 TDR&TXV 13.50 11.10 36,000 3.54 23,200 2.54 8.4 FX4BNF042 33,200 TDR&TXV 13.50 11.05 36,000 3.64 23,400 2.58 8.5 COILS + 58CV(A,X)090-16 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,200 TDR 15.00 12.20 35,200 3.46 21,800 2.58 8.5 CK3BA042 33,200 TDR 15.00 12.20 35,400 3.56 22,000 2.62 8.5 CK5A/CK5BA042 33,200 TDR 15.00 12.20 35,200 3.56 22,000 2.62 8.5 COILS + 58CV(A,X)110-20 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,200 TDR 15.00 12.20 35,400 3.48 21,800 2.58 8.5 CK3BA042 33,200 TDR 15.00 12.20 35,400 3.58 22,000 2.62 8.5 HSPF 11

Combination ratings* continued UNIT SIZE- SERIES 036-30 042-30 See notes on pg. 15. INDOOR UNIT TC Factory- Supplied Enhancement Seasonal Efficiency SEER Standard Rating Puron TXV ARI STANDARD RATINGS* Field-Supplied Accessory High-Temp Low-Temp Puron TXV & TDR** TDR EER TC COP TC COP CK5A/CK5BA042 33,200 TDR 15.00 12.20 35,400 3.58 22,000 2.62 8.5 COILS + 58CV(A,X)135-22 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,200 TDR 15.00 12.25 35,200 3.48 21,800 2.58 8.5 CK3BA042 33,200 TDR 15.00 12.25 35,200 3.58 22,000 2.62 8.5 CK5A/CK5BA042 33,400 TDR 15.00 12.25 35,400 3.58 22,000 2.62 8.5 COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,400 TDR 15.00 12.40 35,200 3.50 21,800 2.60 8.5 CK3BA042 33,200 TDR 15.00 12.35 35,200 3.60 22,000 2.64 8.5 CK5A/CK5BA042 33,400 TDR 15.00 12.35 35,400 3.60 22,000 2.64 8.5 COILS + 58MVP060-14 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,200 TDR 14.50 12.10 35,200 3.44 21,800 2.56 8.5 CK3BA042 33,200 TDR 14.80 12.10 35,200 3.54 22,000 2.60 8.5 CK5A/CK5BA042 33,600 TDR 14.50 11.85 35,200 3.64 22,600 2.64 8.5 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,000 TDR 14.50 11.85 35,400 3.40 22,000 2.54 8.5 CK3BA042 33,000 TDR 14.50 11.85 35,400 3.50 22,200 2.58 8.5 CK5A/CK5BA042 33,600 TDR 14.00 11.60 35,400 3.60 22,800 2.60 8.5 COILS + 58MVP080-20 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,600 TDR 14.20 11.80 36,000 3.54 22,600 2.58 8.5 CK5A/CK5BA042 33,600 TDR 14.00 11.75 36,000 3.64 22,800 2.62 8.5 COILS + 58MVP100-20 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,800 TDR 14.50 11.90 36,000 3.56 22,400 2.60 8.5 CK3BA042 33,200 TDR 14.80 12.10 35,200 3.56 22,000 2.62 8.5 CK5A/CK5BA042 33,800 TDR 14.50 11.85 36,000 3.66 22,600 2.64 8.5 COILS + 58MVP120-20 VARIABLE-SPEED FURNACE CC5A/CD5AA042 33,200 TDR 14.50 12.15 35,200 3.44 21,800 2.56 8.5 CK3BA042 33,200 TDR 14.50 12.15 35,200 3.54 22,000 2.60 8.5 CK5A/CK5BA042 33,200 TDR 14.50 12.15 35,400 3.54 22,000 2.60 8.5 *FV4BNF005 40,500 TDR&TXV 15.00 12.65 41,000 3.86 25,400 2.76 9.5 CC5A/CD5AA042 38,000 NONE 13.00 11.00 41,000 3.44 26,200 2.50 8.2 CC5A/CD5AC048 38,000 NONE 12.70 10.90 41,000 3.32 26,200 2.46 8.2 CC5A/CD5AW042 38,000 NONE 13.00 10.85 40,500 3.34 26,200 2.46 8.2 CC5A/CD5AW048 38,500 NONE 13.00 11.00 41,500 3.48 26,200 2.52 8.5 CD5AA048 38,500 NONE 13.00 11.05 42,000 3.48 26,400 2.52 8.5 CE3AA042 38,500 NONE 13.00 11.05 41,000 3.52 26,400 2.54 8.4 CE3AA048 39,000 NONE 13.00 11.10 41,500 3.54 26,400 2.54 8.7 CK3BA042 38,000 NONE 13.00 11.00 41,000 3.52 26,400 2.54 8.2 CK3BA048 38,500 NONE 13.00 11.05 41,500 3.58 26,400 2.56 8.5 CK5A/CK5BA042 38,500 NONE 13.00 11.00 41,000 3.52 26,400 2.54 8.2 CK5A/CK5BA048 38,500 NONE 13.00 11.05 41,500 3.58 26,400 2.56 8.5 CK5A/CK5BE042 38,500 NONE 13.00 11.05 41,000 3.58 26,400 2.56 8.5 CK5A/CK5BT042 38,500 NONE 13.00 11.00 41,000 3.52 26,400 2.54 8.2 CK5A/CK5BT048 38,500 NONE 13.00 11.05 41,500 3.58 26,400 2.56 8.5 CK5A/CK5BW048 38,500 NONE 13.00 11.05 41,500 3.58 26,400 2.56 8.5 CK5PA042 38,000 TXV 13.00 11.00 41,000 3.52 26,400 2.54 8.2 CK5PA048 38,500 TXV 13.00 11.05 41,500 3.58 26,400 2.56 8.5 CK5PE042 38,500 TXV 13.00 11.05 41,000 3.58 26,400 2.56 8.5 CK5PT042 38,000 TXV 13.00 11.00 41,000 3.52 26,400 2.54 8.2 CK5PT048 38,500 TXV 13.00 11.05 41,500 3.58 26,400 2.56 8.5 CK5PW048 38,500 TXV 13.00 11.05 41,500 3.58 26,400 2.56 8.5 F(A,B)4BN(F,B,C)042 38,000 TDR 13.00 11.00 41,000 3.40 26,000 2.48 8.5 F(A,B)4BN(F,B,C)048 39,000 TDR 13.00 11.05 42,000 3.62 26,600 2.56 8.5 FC4CNB054 40,000 TDR&TXV 14.00 11.75 42,000 3.76 26,200 2.64 9.0 FE4ANB006 41,000 TDR&TXV 15.50 12.95 41,500 4.00 25,400 2.82 9.7 FE4ANF005 40,500 TDR&TXV 15.00 12.65 41,000 3.86 25,400 2.76 9.5 FK4DNB006 41,000 TDR&TXV 15.50 12.95 41,500 4.00 25,400 2.82 9.7 FK4DNF005 40,500 TDR&TXV 15.00 12.65 41,000 3.86 25,400 2.76 9.5 FV4BNB006 41,000 TDR&TXV 15.50 12.95 41,500 4.00 25,400 2.82 9.7 FX4BNF042 38,500 TDR&TXV 13.50 11.20 41,500 3.54 26,200 2.54 8.8 FX4BNF048 40,000 TDR&TXV 13.50 11.30 42,000 3.72 26,800 2.60 9.0 COILS + 58CV(A,X)090-16 VARIABLE-SPEED FURNACE CD5AA048 38,000 TDR 14.50 11.90 40,500 3.48 25,200 2.56 8.8 CK3BA048 38,500 TDR 14.50 11.95 40,500 3.60 25,200 2.62 8.8 CK5A/CK5BA048 38,500 TDR 14.50 11.90 40,500 3.60 25,400 2.62 8.8 COILS + 58CV(A,X)110-20 VARIABLE-SPEED FURNACE CD5AA048 38,500 TDR 14.50 11.90 40,500 3.48 25,200 2.56 8.8 HSPF 12

Combination ratings* continued UNIT SIZE- SERIES 042-30 048-30 See notes on pg. 15. INDOOR UNIT TC Factory- Supplied Enhancement Seasonal Efficiency SEER Standard Rating Puron TXV ARI STANDARD RATINGS* Field-Supplied Accessory High-Temp Low-Temp Puron TXV & TDR** TDR EER TC COP TC COP CK3BA048 38,500 TDR 14.50 11.95 40,500 3.60 25,400 2.62 8.8 CK5A/CK5BA048 38,500 TDR 14.50 11.95 40,500 3.60 25,400 2.62 8.8 COILS + 58CV(A,X)135-22 VARIABLE-SPEED FURNACE CD5AA048 38,500 TDR 14.50 12.05 40,000 3.52 25,000 2.58 8.8 CK3BA048 38,500 TDR 14.50 12.10 40,500 3.64 25,200 2.64 8.8 CK5A/CK5BA048 38,500 TDR 14.50 12.10 40,500 3.64 25,200 2.64 8.8 COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACE CD5AA048 38,500 TDR 14.50 12.10 40,000 3.50 25,000 2.58 8.8 CK3BA048 38,500 TDR 14.50 12.15 40,500 3.64 25,200 2.64 8.8 CK5A/CK5BA048 38,500 TDR 14.50 12.15 40,500 3.62 25,200 2.64 8.8 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE CD5AA048 38,000 TDR 14.00 11.55 40,500 3.40 25,400 2.52 8.5 CK3BA048 38,000 TDR 13.70 11.60 40,500 3.52 25,600 2.58 8.5 CK5A/CK5BA048 38,500 TDR 13.50 11.60 40,500 3.52 25,600 2.56 8.8 COILS + 58MVP080-20 VARIABLE-SPEED FURNACE CD5AA048 38,000 TDR 14.00 11.70 40,500 3.44 25,200 2.54 8.5 CK3BA048 38,500 TDR 14.00 11.75 40,500 3.56 25,400 2.60 8.8 CK5A/CK5BA048 38,500 TDR 14.00 11.70 40,500 3.56 25,400 2.60 8.8 COILS + 58MVP100-20 VARIABLE-SPEED FURNACE CD5AA048 38,000 TDR 14.00 11.80 40,500 3.46 25,200 2.56 8.5 CK3BA048 38,500 TDR 14.00 11.85 40,500 3.58 25,400 2.62 8.8 CK5A/CK5BA048 38,500 TDR 14.00 11.85 40,500 3.58 25,400 2.60 8.8 COILS + 58MVP120-20 VARIABLE-SPEED FURNACE CD5AA048 38,000 TDR 14.00 11.85 40,000 3.46 25,200 2.56 8.5 CK3BA048 38,500 TDR 14.00 11.90 40,500 3.58 25,200 2.62 8.8 CK5A/CK5BA048 38,500 TDR 14.00 11.90 40,500 3.58 25,400 2.60 8.8 *FV4BNB006 46,500 TDR&TXV 15.00 12.95 48,000 3.96 30,600 2.84 9.5 CC5A/CD5AA060 44,000 NONE 13.00 11.20 48,000 3.40 31,200 2.54 8.5 CC5A/CD5AC048 43,000 NONE 12.70 11.05 47,000 3.24 30,800 2.48 8.0 CC5A/CD5AW048 44,000 NONE 13.00 11.20 48,000 3.46 31,200 2.56 8.5 CC5A/CD5AW060 45,000 NONE 13.50 11.50 48,000 3.60 31,400 2.62 8.7 CD5AA048 44,000 NONE 13.00 11.20 48,000 3.46 31,200 2.56 8.5 CD5PX060 46,000 TXV 13.50 11.65 48,000 3.84 31,800 2.72 9.0 CE3AA048 43,500 NONE 13.00 11.35 48,000 3.50 31,200 2.60 8.2 CE3AA060 45,000 NONE 13.50 11.55 48,000 3.62 31,600 2.64 8.5 CK3BA048 43,500 NONE 13.00 11.20 48,000 3.56 31,400 2.60 8.2 CK3BA060 44,000 NONE 13.00 11.50 48,000 3.74 31,600 2.68 8.5 CK5A/CK5BA048 43,500 NONE 13.00 11.20 48,000 3.56 31,400 2.60 8.5 CK5A/CK5BA060 44,000 NONE 13.00 11.50 48,000 3.74 31,600 2.68 8.5 CK5A/CK5BT048 43,500 NONE 13.00 11.20 48,000 3.56 31,400 2.60 8.5 CK5A/CK5BT060 44,000 NONE 13.00 11.50 48,000 3.74 31,600 2.68 8.5 CK5A/CK5BW048 43,500 NONE 13.00 11.20 48,000 3.56 31,400 2.60 8.5 CK5A/CK5BX060 45,000 NONE 13.50 11.70 48,000 3.74 31,600 2.70 8.5 CK5PA048 43,500 TXV 13.00 11.20 48,000 3.56 31,400 2.60 8.5 CK5PA060 44,000 TXV 13.00 11.50 48,000 3.74 31,600 2.68 8.5 CK5PT048 43,500 TXV 13.00 11.20 48,000 3.56 31,400 2.60 8.5 CK5PT060 44,000 TXV 13.00 11.50 48,000 3.74 31,600 2.68 8.5 CK5PW048 43,500 TXV 13.00 11.20 48,000 3.56 31,400 2.60 8.5 CK5PX060 45,000 TXV 13.50 11.70 48,000 3.74 31,600 2.70 8.5 F(A,B)4BN(F,B,C)048 44,500 TDR 13.00 11.15 48,000 3.60 31,800 2.60 8.5 F(A,B)4BN(F,B,C)060 45,500 TDR 13.00 11.20 48,000 3.66 32,200 2.64 8.7 FB4BNB070 46,000 TDR 13.50 11.65 48,000 3.84 32,000 2.70 9.0 FC4CNB054 46,000 TDR&TXV 14.00 12.05 48,000 3.80 31,200 2.72 9.0 FE4ANB006 46,500 TDR&TXV 15.00 12.95 48,000 3.96 30,600 2.84 9.5 FE4ANF005 46,000 TDR&TXV 15.00 12.60 48,000 3.82 30,600 2.78 9.5 FK4DNB006 46,500 TDR&TXV 15.00 12.95 48,000 3.96 30,600 2.86 9.5 FK4DNF005 46,000 TDR&TXV 15.00 12.60 48,000 3.82 30,400 2.78 9.5 FV4BNF005 46,000 TDR&TXV 15.00 12.60 48,000 3.82 30,600 2.78 9.5 FX4BNB060 46,500 TDR&TXV 13.50 11.65 48,000 3.84 32,200 2.72 9.0 FX4BNF048 46,000 TDR&TXV 13.50 11.50 48,000 3.70 32,000 2.68 8.7 COILS + 58CV(A,X)110-20 VARIABLE-SPEED FURNACE CC5A/CD5AA060 43,500 TDR 13.50 11.75 48,000 3.36 30,200 2.58 8.2 CD5PX060 45,500 TDR&TXV 14.50 12.25 48,000 3.80 30,800 2.76 9.0 CK3BA060 44,000 TDR 14.00 12.15 48,000 3.72 30,800 2.72 8.2 CK5A/CK5BA060 43,500 TDR 13.50 12.20 48,000 3.72 30,600 2.72 8.2 CK5A/CK5BX060 45,500 TDR 14.50 12.35 48,000 3.74 30,600 2.74 9.0 COILS + 58CV(A,X)135-22 VARIABLE-SPEED FURNACE CC5A/CD5AA060 43,500 TDR 14.00 11.95 48,000 3.38 30,000 2.58 8.5 HSPF 13

Detailed cooling capacities* continued UNIT SIZE- SERIES 048-30 060-30 See notes on pg. 15. INDOOR UNIT TC Factory- Supplied Enhancement Seasonal Efficiency SEER Standard Rating Puron TXV ARI STANDARD RATINGS* Field-Supplied Accessory High-Temp Low-Temp Puron TXV & TDR** TDR EER TC COP TC COP CD5PX060 45,500 TDR&TXV 14.50 12.45 48,000 3.84 30,600 2.78 9.0 CK3BA060 44,000 TDR 14.00 12.35 48,000 3.74 30,600 2.74 8.5 CK5A/CK5BA060 43,500 TDR 14.00 12.35 48,000 3.76 30,400 2.74 8.5 CK5A/CK5BX060 45,500 TDR 14.50 12.50 48,000 3.76 30,400 2.76 9.0 COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACE CC5A/CD5AA060 43,500 TDR 14.00 12.05 48,000 3.40 30,000 2.60 8.5 CD5PX060 45,500 TDR&TXV 14.50 12.55 48,000 3.86 30,600 2.80 9.0 CK3BA060 44,000 TDR 14.00 12.45 48,000 3.78 30,600 2.76 8.5 CK5A/CK5BA060 43,500 TDR 14.00 12.45 48,000 3.78 30,400 2.76 8.5 CK5A/CK5BX060 45,500 TDR 14.50 12.60 48,000 3.80 30,400 2.78 9.0 COILS + 58MVP080-20 VARIABLE-SPEED FURNACE CC5A/CD5AA060 43,500 TDR 13.50 11.55 48,000 3.32 30,400 2.54 8.2 CD5PX060 45,000 TDR&TXV 14.00 12.05 48,000 3.76 30,800 2.72 9.0 CK3BA060 44,000 TDR 13.50 11.95 48,000 3.68 31,000 2.70 8.2 CK5A/CK5BA060 43,500 TDR 13.50 11.95 48,000 3.68 30,800 2.68 8.2 CK5A/CK5BX060 45,000 TDR 14.00 12.10 48,000 3.70 30,800 2.70 9.0 COILS + 58MVP100-20 VARIABLE-SPEED FURNACE CC5A/CD5AA060 43,500 TDR 13.50 11.65 48,000 3.34 30,200 2.56 8.2 CD5PX060 45,000 TDR&TXV 14.00 12.10 48,000 3.78 30,800 2.74 9.0 CK3BA060 44,000 TDR 13.50 12.00 48,000 3.70 30,800 2.70 8.2 CK5A/CK5BA060 43,500 TDR 13.50 12.05 48,000 3.70 30,600 2.70 8.2 CK5A/CK5BX060 45,500 TDR 14.00 12.20 48,000 3.72 30,800 2.72 9.0 COILS + 58MVP120-20 VARIABLE-SPEED FURNACE CC5A/CD5AA060 43,500 TDR 13.50 11.65 48,000 3.32 30,200 2.56 8.2 CD5PX060 45,000 TDR&TXV 14.00 12.15 48,000 3.78 30,800 2.74 9.0 CK3BA060 44,000 TDR 13.50 12.05 48,000 3.68 30,800 2.70 8.2 CK5A/CK5BA060 43,500 TDR 13.50 12.05 48,000 3.70 30,600 2.70 8.2 CK5A/CK5BX060 45,500 TDR 14.00 12.20 48,000 3.70 30,600 2.72 9.0 *FV4BNB006 56,000 TDR&TXV 14.00 11.65 60,000 3.68 38,500 2.74 9.0 CC5A/CD5AW060 54,000 NONE 13.00 10.60 60,000 3.38 39,000 2.54 8.0 CD5PX060 54,000 TXV 13.00 10.80 60,000 3.56 39,000 2.64 8.5 CE3AA060 54,000 NONE 13.00 10.70 60,000 3.42 39,000 2.58 8.0 CK3BA060 53,500 NONE 12.70 10.60 60,000 3.52 39,000 2.60 8.0 CK5A/CK5BA060 53,500 NONE 13.00 10.60 60,000 3.52 39,000 2.60 8.0 CK5A/CK5BT060 53,500 NONE 13.00 10.60 60,000 3.52 39,000 2.60 8.0 CK5A/CK5BX060 54,000 NONE 13.00 10.80 60,000 3.56 39,500 2.62 8.5 CK5PA060 53,500 TXV 13.00 10.60 60,000 3.52 39,000 2.60 8.5 CK5PT060 53,500 TXV 13.00 10.60 60,000 3.52 39,000 2.60 8.0 CK5PX060 54,000 TXV 13.00 10.80 60,000 3.56 39,500 2.62 8.5 F(A,B)4BN(F,B,C)060 53,500 TDR 12.50 10.30 60,000 3.42 40,000 2.54 8.0 FB4BNB070 55,500 TDR 13.00 10.80 60,000 3.60 39,500 2.64 8.5 FE4ANB006 56,000 TDR&TXV 14.00 11.55 60,000 3.68 38,500 2.74 9.0 FK4DNB006 56,000 TDR&TXV 14.00 11.55 60,000 3.68 38,500 2.74 9.0 FX4BNB060 55,500 TDR&TXV 13.00 10.80 60,000 3.60 39,500 2.64 8.5 COILS + 58CV(A,X)110-20 VARIABLE-SPEED FURNACE CD5PX060 54,000 TDR&TXV 13.00 10.85 60,000 3.52 38,500 2.62 8.5 CK3BA060 53,500 TDR 13.00 10.85 60,000 3.44 38,500 2.58 8.0 CK5A/CK5BX060 54,500 TDR 13.50 11.10 60,000 3.46 38,500 2.60 8.5 COILS + 58CV(A,X)135-22 VARIABLE-SPEED FURNACE CD5PX060 54,000 TDR&TXV 13.50 11.05 60,000 3.56 38,500 2.66 8.5 CK3BA060 53,500 TDR 13.00 11.00 60,000 3.46 38,000 2.60 8.5 CK5A/CK5BX060 54,500 TDR 13.50 11.25 60,000 3.50 38,000 2.64 8.5 COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACE CD5PX060 54,000 TDR&TXV 13.50 11.20 60,000 3.58 38,500 2.68 8.5 CK3BA060 53,500 TDR 13.50 11.10 60,000 3.48 38,000 2.62 8.5 CK5A/CK5BX060 55,000 TDR 13.50 11.35 60,000 3.52 38,000 2.66 8.5 HSPF 14

* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on: Standard: 80 F (27 C) db 67 F (19 C) wb indoor entering air temperature and 95 F (35 C) db air entering outdoor unit. High-Temp Standard: 70 F (21 C) db indoor entering air temperature and 47 F (8 C) db 43 F (6 C) wb air entering outdoor unit. Low-Temp Standard: 70 F (21 C) db indoor entering air temperature and 17 F ( 9 C) db 15 F ( 10 C) wb air entering outdoor unit. Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are determined under DOE computer simulation procedures. Based on computer simulation. TXV must be Puron compatible and hard shutoff type. ** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Airflow Must replace factory-supplied R-22 TXV with Puron TXV. SEER Seasonal Energy Efficiency Ratio TC (Btuh) COP Coefficient of Performance TDR Time-Delay Relay HSPF Seasonal Performance Factor TXV Thermostatic Expansion Valve EER Energy Efficiency Ratio 15

Detailed cooling capacities* EVAPORATOR AIR CFM 700 MBtuh CONDENSER ENTERING AIR TEMPERATURES F 75 85 95 105 115 125 kw** MBtuh kw** MBtuh kw** MBtuh kw** MBtuh kw** MBtuh EWB Sens Sens Sens Sens Sens Sens 38YSP024-30 Outdoor Section With FV4BNF002 Section 72 27.45 14.26 1.42 26.08 13.73 1.61 24.65 13.18 1.83 23.16 12.62 2.06 21.55 12.01 2.31 19.76 11.36 2.59 67 25.17 17.65 1.42 23.91 17.10 1.61 22.60 16.54 1.82 21.23 15.97 2.06 19.76 15.35 2.31 18.14 14.69 2.58 63 23.49 17.11 1.41 22.32 16.57 1.61 21.11 16.01 1.82 19.83 15.44 2.05 18.47 14.83 2.31 16.97 14.17 2.58 62 23.05 21.01 1.41 21.91 20.45 1.61 20.73 19.86 1.82 19.51 19.22 2.05 18.30 18.30 2.31 17.06 17.06 2.58 57 22.30 22.30 1.41 21.39 21.39 1.61 20.43 20.43 1.82 19.41 19.41 2.05 18.30 18.30 2.31 17.06 17.06 2.58 72 27.97 14.95 1.44 26.53 14.41 1.63 25.05 13.85 1.84 23.50 13.27 2.08 21.83 12.66 2.33 19.99 12.00 2.60 67 25.66 18.77 1.43 24.35 18.21 1.63 22.98 17.64 1.84 21.56 17.05 2.07 20.03 16.43 2.33 18.36 15.74 2.60 800 63 23.98 18.17 1.43 22.75 17.62 1.62 21.48 17.05 1.84 20.16 16.46 2.07 18.74 15.83 2.32 17.20 15.15 2.60 62 23.57 22.52 1.43 22.39 21.91 1.62 21.21 21.21 1.83 20.11 20.11 2.07 18.93 18.93 2.32 17.61 17.61 2.60 57 23.20 23.20 1.43 22.23 22.23 1.62 21.20 21.20 1.83 20.11 20.11 2.07 18.93 18.93 2.32 17.61 17.61 2.60 72 28.36 15.61 1.45 26.88 15.06 1.65 25.36 14.49 1.86 23.76 13.91 2.09 22.04 13.29 2.35 20.15 12.61 2.62 67 26.04 19.84 1.45 24.68 19.28 1.64 23.27 18.70 1.85 21.81 18.10 2.09 20.24 17.45 2.34 18.53 16.74 2.61 900 63 24.35 19.18 1.45 23.08 18.62 1.64 21.77 18.04 1.85 20.41 17.43 2.08 18.95 16.79 2.34 17.37 16.08 2.61 62 24.02 23.84 1.45 22.92 22.92 1.64 21.84 21.84 1.85 20.69 20.69 2.08 19.44 19.44 2.34 18.05 18.05 2.61 57 23.96 23.96 1.45 22.92 22.92 1.64 21.84 21.84 1.85 20.69 20.69 2.08 19.44 19.44 2.34 18.05 18.05 2.61 Multipliers for Determining the Performance With Other Sections. Section Size Power Section Size Power CC5A/CD5AA 036 0.97 1.09 COILS + 58CV(A,X)090-16 VARIABLE-SPEED FURNACE CC5A/CD5AW 036 0.97 1.09 CC5A/CD5AA 036 0.97 0.98 CE3AA 036 0.96 1.09 CK3BA 036 0.97 0.97 CK3BA 036 0.97 1.09 CK5A/CK5BA 036 0.97 0.97 CK5A/CK5BA 036 0.97 1.09 COILS + 58CV(A,X)110-20 VARIABLE-SPEED FURNACE CK5A/CK5BT 036 0.97 1.09 CC5A/CD5AA 036 0.97 0.98 CK5A/CK5BW 036 0.97 1.09 CK3BA 036 0.97 0.98 CK5PA 036 0.97 1.09 CK5A/CK5BA 036 0.97 0.98 CK5PT 036 0.97 1.09 COILS + 58MVP060-14 VARIABLE-SPEED FURNACE CK5PW 036 0.97 1.09 CC5A/CD5AA 036 0.97 0.98 FE4ANF 002 1.00 0.99 CK5A/CK5BA 036 0.97 0.98 003 1.00 0.98 COILS + 58MVP080-14 VARIABLE-SPEED FURNACE FV4BNF 002 1.00 1.00 CC5A/CD5AA 036 0.97 0.99 003 1.00 0.98 CK5A/CK5BA 036 0.97 0.98 FX4BNF 030 0.99 1.10 COILS + 58MVP080-20 VARIABLE-SPEED FURNACE COILS + 58CV(A,X)070-12 VARIABLE-SPEED FURNACE CC5A/CD5AA 036 0.97 0.99 CC5A/CD5AA 036 0.97 0.99 CK5A/CK5BA A036 0.97 0.98 CK3BA 036 0.97 0.98 COILS + 58MVP100-20 VARIABLE-SPEED FURNACE CK5A/CK5BA 036 0.97 0.98 CC5A/CD5AA 036 0.97 0.98 CK5A/CK5BA 036 0.97 0.98 See notes on pg. 21. kw** 16