Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols. Publication date: 2016

Similar documents
Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 9 Heiselberg, Per Kvols. Publication date: 2016

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress Heiselberg, Per Kvols. Publication date: 2016

Field Study of Diffuse Ceiling Ventilation Performance in a Landscape Office

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols. Publication date: 2016

The Performance of Diffuse Ceiling Inlet and other Room Air Distribution Systems Nielsen, Peter Vilhelm; Jakubowska, Ewa

Impact of Air Distribution on Heat Transfer during Night-Time Ventilation

On the Architectural Engineering Competences in Architectural Design MSc in Engineering with Specialization in Architecture Kirkegaard, Poul Henning

Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings

Can painted glass felt or glass fibre cloth be used as vapour barrier?

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

K.F. Fong *, C.K. Lee, T.T. Chow

Research on Waste Heat Recovery System for Residential Gas Engine-Driven Heat Pump

Air Distribution and Ventilation Effectiveness in a room with Floor/Ceiling Heating and Mixing/Displacement Ventilation

COOLED PLATE TESTS ON TEXTILE MATERIALS IN SIMULATED COCKPIT UNDER SOLAR RADIATION

Air and operative temperature measurements in a plus-energy house under different heating strategies

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Villa Bagatelle Technical Report

HEAT PUMPS AND PUBLIC SWIMMING POOLS, A PERFECT MATCH

Comparison of radiant and convective cooling of office room: effect of workstation layout

The Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

Maximum Obtainable Efficiency For Engines And Refrigerators Based On The Stirling Cycle

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

SOLAR HEATING AND COOLING FOR THE SOLAR CITY GLEISDORF

Thermal Environment in a Space with Capillary Mats Large-Area Cooling and Heating

Effects of Latent/Sensible Heat Separation Air-Conditioning and Natural Ventilation on Indoor Thermal Environment in Environment-Friendly Office

Adelaide Homes Design Guide 4 - Winter warming

Energy and Exergy Performances of Air-Based vs. Water-Based Heating and Cooling Systems: A Case Study of a Single-Family House

Experimental Study on Crawl-Space Heating with Thermal Storage using Heat Pump

State of the Art of HVAC Technology in Europe and America

Recent Advances in Energy, Environment and Economic Development

A study of radiant cooling for a room with daytime application in tropical climate

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

The Corbioli House is a single-family house situated

An interdisciplinary approach to identify adaptation strategies that enhance flood resilience and urban liveability

White Paper Dehumidification in Humid Climates - A Theoretical Case Study

Chapter 10. Passive Cooling Contents

Design, Construction and Testing of Simple Solar Maize Dryer

Heat Pumps and Public Swimming Pools, a Perfect Match

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

Comparison of Thermal Comfort by Radiant Heating and Convective Heating

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

EVALUATION OF A LIQUID DESICCANT AIR CONDITIONING SYSTEM WITH SOLAR THERMAL REGENERATION

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

Adsorption Chillers Energysmart Green Cooling

Performance of Chilled Beam with Radial Swirl Jet and Diffuse Ceiling Air Supply in Heating Mode

Evaluation of Liquid Water Content in Thermal Efficient Heating Mechanism Using Water Vapor for Industrial Furnace

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Hygrothermal evaluation of a museum storage building based on actual measurements and simulations

Diffuse Ceiling Ventilation Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols; Pomianowski, Michal Zbigniew; Nielsen, Peter Vilhelm

Itaru TAKAHASHI Ph.D 1 Akihiko KUROIWA 2

Design and Experimental Studies on Modified Solar Dryer

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

Solar Sustainable Heating, Cooling and Ventilation of a Net Zero Energy House

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

DEVELOPMENT OF A KILN DRIED WOOD SYSTEM USING HEAT PUMP TECHNOLOGY

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

Cooling load calculations of radiant and all-air systems for commercial buildings

IEA EBC Annex 59 - Possibilities, limitations and capacities of indoor terminal units

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Heat Transfer in Evacuated Tubular Solar Collectors

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

Households' energy use - which is the more important: efficient technologies or user practices? Gram-Hanssen, Kirsten

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

WHAT - HOW - WHY - WHERE PROTERCEILING RADIANT CHILLED CEILINGS COMFORT - EFFICIENCY - SAVINGS - AESTHETICS

Variable far infrared radiation (VFIR) technique for cubic carrot drying

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

THE HEAT PUMP CHOICE OF PROFESSIONALS

So far, we have covered the basic concepts of heat transfer and properties.

PERFORMANCE ANALYSIS OF GROUND SOURCE HEAT PUMPS FOR DOMESTIC HOT WATER SUPPLY IN THE LOW ENERGY HOUSE AND ITS APPLICATION

Study on an environmental simulation system of low/high temperature. for great space

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Solar Liquid Desiccant Air- Conditioning

Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning

Remark

MECHANICAL SCIENCE Module 2 Heat Exchangers

Smart Green Roofs: Cooling with variable insulation

Energy Recovery Ventilation

Performance Analysis of a Solid Desiccant Air Dehumidifier

Comfort and health-indoor air quality

Diffuse Ceiling Ventilation Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols; Pomianowski, Michal Zbigniew; Nielsen, Peter Vilhelm

VRV The total solution. Integrated Climate Control

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER

CONTENTS. Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7

Feasibility Analysis of Regeneration of Silica Gel Used in Dehumidification Process of Air Conditioning by the Condenser Waste Heat of Air Conditioner

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Transcription:

Downloaded from vbn.aau.dk on: marts 27, 2019 Aalborg Universitet CLIMA 2016 - proceedings of the 12th REHVA World Congress volume 3 Heiselberg, Per Kvols Publication date: 2016 Document Version Publisher's PDF, also known as Version of record Link to publication from Aalborg University Citation for published version (APA): Heiselberg, P. K. (Ed.) (2016). CLIMA 2016 - proceedings of the 12th REHVA World Congress: volume 3. Aalborg: Aalborg University, Department of Civil Engineering. General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.? Users may download and print one copy of any publication from the public portal for the purpose of private study or research.? You may not further distribute the material or use it for any profit-making activity or commercial gain? You may freely distribute the URL identifying the publication in the public portal? Take down policy If you believe that this document breaches copyright please contact us at vbn@aub.aau.dk providing details, and we will remove access to the work immediately and investigate your claim.

Thermal Storage Radiation Air-conditioning System from the Concrete Slab that uses Underground Heat and Solar Heat Directly Tomoyuki Chikamoto #1, Kentaro Sekine #2, Yoichi Kobayashi #3, Myonghyang Lee #4 #1, #4 Department of Science and Engineering, Ritsumeikan University 1-1-1 Nojihigashi, Kusatsu-shi, Shiga, 525-8577, Japan #1 tomoyuki@se.ritsumei.ac.jp, #4 myonglee@fc.ritsumei.ac.jp #2 Technology Center, Taisei Corporation 344-1 Nase-cho, Totsuka-ku, Yokohama, 245-0051, Japan kentaro.sekine@sakura.taisei.co.jp #3 Yasui Architects & Engineers, Inc. 2-4-7 Shimamachi, Chuo-ku, Osaka, 540-0034, Japan youichi-kobayashi@yasui-archi.co.jp Abstract We proposed the system that uses the renewable energy by bringing water from the pipes and piles under the soil, and solar collectors on the roof, into the concrete floor and ceiling slab directly without any other heat sources. To lay the pipes under the soil, rolled pipes are set as they are, to reduce construction time greatly. Piles are recycled by using the pile with the shuttlecock on the head of the pile. Concerning the solar collector, we developed the simple one, which can be used even when repairing the building. The cost is verified through an actual design and construction of the building, and it aims at the establishment of the best design and the construction technique. Moreover, the performance of the system is evaluated by the measurement of the building. COP (coefficient of performance) of this system is around 10 in cooling season summer, because this system does not have any heat sources, but also pumps which supplies the water from soil and solar collector to the concrete slab optimized by inverter. The amount of the CO2 exhaust reduction is about 4.0 kg-co2/m 2 by measurement from July 19 to August 22, 2014. It becomes about 8.1 kg-co2/m 2 /year. Concerning the energy reduction rate of the air-conditioning system, about 20% energy conservation is achieved. Keywords natural ventilation; cross ventilation; hybrid ventilation; 1. Introduction The technique for using underground heat and solar heat for airconditioning is very effective for the CO 2 exhaust reduction. When solar heat and underground heat are used for cooling and heating, another heat source such as heat pump and boiler, will be often used to supply steady cold and hot water for HVAC system. However the initial cost of the equipment is not cheap. In addition, when underground heat is used, it is necessary to lay the

pipes or piles under the soil, and it leads to high initial cost, which disturbs the widespread of these kinds of system. Then, we proposed the system that uses the renewable energy by bringing water from the pipes and piles under the soil, and solar collectors on the roof, into the concrete floor and ceiling slab directly without any other heat sources. To lay the pipes under the soil, rolled pipes are set as they are, to reduce construction time greatly. Piles are recycled by using the pile with the shuttlecock on the head of the pile. Concerning the solar collector, we developed the simple one, which can be used even when repairing the building. The cost is verified through an actual design and construction of the building, and it aims at the establishment of the best design and the construction technique. Moreover, the performance of the system is evaluated by the measurement of the existing building. 2. Outline of the System Figure 1 shows the outline of the system. This system is introduced in the new building in our university. It uses the renewable energy by bringing water from the pipes and piles under the soil, and solar collectors on the roof. The water goes into pipes laid in the concrete floor and ceiling slab directly without any other heat sources. It is a radiation air conditioning system using thermal storage of the building frame. There are a lot of radiation air conditioning systems that use the ceiling panel. This system does not use any ceiling or floor panel, to reduce the initial cost and use the thermal storage effect of the concrete slab. The piping longevity equal with the building can be expected because the piping laid uses thin metal layer sandwiched by reinforced polyethylene which has high heat resistance, causticity and processability. Radiative cooling and heating from ceiling or floor Solar collector on the roof Ceiling fan Horizontal underground piping Vertical borehole underground piping Fig. 1 Outline of the system using underground heat and solar heat directly

2.1 Outline of the air-conditioning system from the concrete slab To verify the heat flow both from ceiling and floor, the room on one floor has heat transmission from floor, and the room on another floor has different heat transmission from ceiling, as shown in Figure 1. Figure 2 shows the situation of piping laid in the concrete slab. In winter, underground water is used for the preheating of outer air for ventilation using the air processing air-conditioning system. (2) Atmosphere treating AC Dehumidification of outer air (1) FCU Dehumidification of indoor air Prevent the dewfall (4) Ceiling fan Promote the heat transfer to raise the surface temperature (3) Desiccant AC Dehumidification of outer air Fig. 2 The piping laid in the concrete slab Fig. 3 Options for dehumidification The temperature of the water from underground is around 18-20 o C all the year round, it is a little higher than dew point temperature of the indoor air, therefore the system using underground heat for cooling directly does not lead to dewfall through the year. However, in Japan, we have very hot and humid summer, therefore some options were examined for dehumidification. Figure 3 shows 4 options. 1 st is the FCU set in all rooms in this building by controlling the target indoor air temperature, because their supply temperature are not controllable. 2 nd is the atmosphere treating airconditioning system introducing outside air for ventilation by controlling the supply temperature and dehumidification performance. 3 rd is the desiccant air conditioners. We use 2 types of the unit. One is the packaged type using heat pump, and the other is unit type which uses hot water from solar collector for regenerator of absorbent, and cold water from underground for cooling. 4 th is the ceiling fan promoting the airflow near ceiling and floor. The ceiling fan is set up in the room, promotes the convective heat transfer from the concrete slab, and the dew condensation will be prevented. For the renovation, the verification of the exposed piping system for cooling and heating under the ceiling was also done (Figures 4).

Figs. 4 Exposed piping system under the ceiling 2.2 Outline of the system using the underground heat The vertical borehole and the horizontal piping laid underground are used. Concerning the borehole, piles are recycled by using the pile with the shuttlecock on the head of the pile. The depth of the borehole is 36 m, and 9 boreholes were constructed. In the normal construction borehole technique, various machine parts such as the boring machine, pumps, water tanks, and the digging rejection soil are needed. The price of the steel recycle pile is high though it generates low noise, low vibration, and no remainder soil, because it digs using the shuttlecock by rotating. The method developed this time inserts the polyethylene piping after it digs, and leaves the polyethylene piping, then pulls out the steel pile by reverse-rotation. It is thought that cost becomes only construction expense, and can be constructed cheaper than the normal method, because the steel pile with the wing is repeatedly used. The normal technique was executed for the comparative verification. The depth of it is 100 m, and 3 boreholes were constructed. Coupling Diging the pile Polyethylene piping Inserting the polyethylene piping Leaving the polyethylene piping, then pulling out the steel pile Reverse-rotation and reuse the pile Fig. 5 Borehole, piles are recycled by using the pile with the shuttlecock

To lay the pipes under the building, rolled pipes are set as they are, to reduce construction time greatly. In this technique, polyethylene piping is set by sideways moving as it is and fixed with insulation lock mutually. In normal technique, the polyethylene piping that had been carried by the scroll was enlarged, and fixed to the wire mesh after the wire mesh is constructed for piping of the horizontal laying underground (Figures 6). Time and cost to set wire mesh will be also decreased. The normal technique was also executed for the comparative verification. (1) Rolled pipes are set as they are (2) Normal pipes set Figs. 6 Horizontal piping laid underground 2.3 Outline of the system using the solar heat Concerning the solar collector, we developed the simple one, which can be used even when repairing the building. The cost is verified through an actual design and construction of the building, and it aims at the establishment of the best design and the construction technique. One example is the laying the polyethylene piping in a rooftop suppression concrete layer to get solar heat (Figure 7 (1)). Rooftop suppression concrete exists in many building, therefore it need little extra cost to set in a new building. This solar collector is covered with the transparent polycarbonate board. For the existing buildings, simple solar collector unit which is composed of the polyethylene piping and the transparent polycarbonate board, was putted on the rooftop (Figure 7 (3)). To keep high temperature, for heating and regenerating absorbent for desiccant air conditioning unit, vacuum tube type solar collector is set for verification (Figure 7 (2)).

(1) Piping in a rooftop concrete (2) Vacuum tube type collector (3) Collector for exiting building Figs. 7 Solar collectors 3. Evaluation of performance of cooling using the undergrond heat in summer 3.1 Outline of the field experiment Measurement period is July 23 rd - August 14 th, 2014. The system was turned on at 9:00, and turned off at 17:00. The measurement was executed in three rooms on the 2 nd floor and the 3 rd floor, which are used for laboratory rooms in the university (Figures 8). The surface temperature on ceilings, floors, walls and windows, globe temperatures, and the vertical temperature distribution were measured in each laboratory. Laboratory 1 has the floor side cooling by the ground heat and 2 has the ceiling side. The indoor environment and cooling effect which are caused by the location of the cooling were compared with the result of these laboratories. Laboratory 3 has the exposed piping system under the ceiling. By comparing laboratories 2 and 3, the effectiveness of the exposed piping system is verified. Piping Cooling from floor Cooling from ceiling 3 rd floor plan 2 nd floor plan Figs. 8 Laboratories for measurement

Table 1 Cases analysed in cooling condition using the undergrond heat in summer Case No. Case 0 Case 1 Case 2 Case 3 Case 4 Case 5 Flow quantity 0.0 1.5 5.0 6.0 5.0 5.0 inside the piping (L/min) Dehumidification method FCU FCU FCU FCU Atmosphere treating AC Packaged Desiccant AC 3.2 Field experiment results Figures 9 show the supplied cold heat to the concrete slab of the laboratory from the ground by the water. It was derived by using the data of the temperature difference between inflow and outflow of the concrete slab, and the flow quantity. The supplied heat of Case 1 was smaller than that of Case 2 and 3. It was caused by the slowness of the flow in the pipe of Case 1. Especially at the beginning of the operation, in Case 1, cold heat was not supplied comparing other cases. In Case 1, Reynolds number is not big enough, therefore there is a possibility that is the laminar pipe flow. Keeping the flowing quantity more than a certain amount is important. (1) Case 1 (Flow quantity:1.5l/min) (2) Case 2 (5.0L/min) (3) Case 3 (6.0L/min) Figs. 9 Supplied cold heat to the concrete slab The results of amount of radiative and convective heat transfer from the surface of ceiling or floor in Case 0 and 2 are shown in Figures 10. In Case 2 / laboratory 1, the vertical temperature distribution was generated, and the cool air stayed near the floor, the radiative heat transfer from floor was large, and the convective heat transfer was small. On the other hand, in Case 2 / laboratory 2, because warm air stayed near ceiling and the emissivity of the ceiling metal surface (galvanized sheet iron finish) is low, convective heat transfer was larger than radiative heat transfer. In Case 2, about half of the supplied cold heat from water was transferred to the indoor space. The storage cold heat was transferred in the delay. In Case0 / laboratory 1 there was little heat transfer from floor, and in Case0 / laboratory 2, it was cooled on the surface of the ceiling. It was caused by the warm temperature near ceiling.

Though the results were omitted, in the Case 2 / laboratory 3, which has the exposed piping system under the ceiling, the convective heat transfer was promoted, because there was less conductive heat transfer to the ceiling. 15 W/m 2 10 5 0 5 10 radiative heat convective heat total heat 放射熱伝達量 transfer W/m² 対流熱伝達量 transfer W/m² 合計熱伝達量 transfer W/m² (1) Case 0 / laboratory 1, floor (2) Case 0 / laboratory 2, ceiling 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 W/m 2 15 10 5 0 5 (3) Case 2 / laboratory 1, floor (4) Case 2 / laboratory 2, ceiling 10 9:00 900 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 Figs. 10 Radiative and convective heat transfer from the surface of ceiling or floor COP (coefficient of performance) was calculated from the amount of power consumption of the pump and the supplied cold heat to the concrete slab (Table 2). Generally, COP becomes lower as flowing quantity grows. It is thought that an enough result was confirmed. As for Case 3, supplied cold heat was smaller than assumption, and it leads to low COP. It is thought that the low outside temperature in Case 3 caused low cooling effectiveness. Enough cooling effect and high COP can be achieved by doing the control that supplies necessary flowing quantity, though it verified this time with flowing quantity was constant. Table 2 Result of the COP Case No. Case 1 Case 2 Case 3 power consumption of 2.7 9.0 14.0 the pump (kwh) supplied cold heat to the 23.4 51.7 47.4 concrete slab (MJ) COP 12.1 8.0 4.6

The amount of the latent heat and sensible heat processing of each dehumidification method system was also derived. Though the processing heat by FCU was a little larger than that by other system, in accordance with the difference of the amount of supply (FCU : 900 m 3 /h, and atmosphere treating AC : 600 m 3 /h, packaged desiccant AC : 500 m 3 /h), there was not large difference between these system and the dewfall was not generated. 4. Evaluation of performance of heating using the solar heat in winter 4.1 Outline of the field experiment Measurement period is November 15 th - December 31 th, 2015. The system was turned on at 9:00, and turned off at 17:00. The measurement was executed in two rooms on the 2 nd floor (laboratory 2) and the 3 rd floor (laboratory 1) (Figures 8). Because the capacity of the solar collecting equipment is relatively small, the flow quantity could not be enlarged. Table 3 Cases analysed in heating condition using the solar heat in winter Case No. Case 1 Case 2 Case 3 Case 4 Case 5 Flow quantity 2.8 0.8 0.8 1.5 1.5 inside the piping (L/min) Solar collecting system (3) * (2) * (2) + (3)* (1) * (3) * * (1) Piping in rooftop concrete, (2) Vacuum tube type, (3) Piping on rooftop (see Figures 7) 4.2 Field experiment results The results of temperature in the concrete slab and supplied heat to the concrete slab of the room from the solar collector by the water of Case 1 (piping on rooftop), and Case 3 (piping on rooftop with vacuum tube type) are shown in Figures 11. Temperature in the slab rises in both cases. Supplied heat to the slab of Case 2 became larger than that of Cases 1. Other performance verifications are being executed now. temperature in the concrete slab supplied heat to the concrete slab Case 1 Case 3 Fig. 11 Temperature in the concrete slab and supplied heat to the concrete slab

5. Evaluation of other performance 5.1 Performance of the proposed vertical borehole system The proposed system does not need stock space for water and mud which are needed by normal system, therefore construction necessity area of proposed system became 80% as the one of normal system. And construction cost of proposed system became 70% as the one of normal system by reusing pile etc. The performance of collecting underground heat of the proposed system is about 30~40 W/m and roughly equal as the one of normal system. 5.2 Performance of the proposed solar heat collecting system The performance of collecting solar heat on the roof system is about 40~100 W/m 2, which is about 20~30 % as the one of vacuum type solar collector. 6. Conclusion In this study, we proposed the thermal storage radiation air-conditioning system from the concrete slab that uses underground heat and solar heat directly without any other heat sources that was able to be used at a low price and for the long term. Though room has been left for the improvement e.g. the control method of the amount of the suppling water by the pump, the stable performance of the solar collector etc., the proposed system can achieve relatively high performance. The examination of practical use is scheduled to be attempted in the future.