Oakdale Primary School Expansion Project Appendix C Elec Equipment Schedule

Similar documents
TAITA TAVETA UNIVERSITY P.O.BOX , VOI, KENYA Tel: TENDER NO: TTU/T/01A/

SCHEDULE OF RATES SHEET PRELIMINARIES

Oakdale Primary School Expansion Project Appendix A - MEP Schedule of Works

LED EMERGENCY LIGHTING

The works comprise the complete supply and installation of new Electrical Engineering Services to the site comprising:-

TIMEGUARD WEATHERSAFE OUTDOOR POWER RANGE INSTALLATION & OPERATING INSTRUCTIONS

Proposed Development at Likoni Road, Nairobi for NTSA - Electrical Installations Bills of Quantities. DESCRIPTION QTY UNIT RATE AMOUNT KSh. 28 No.

EDS SUBSTATION ELECTRICAL SERVICES

GOLDFIELDS PRIMARY SCHOOL. TENDER SPECIFICATION For ELECTRICAL SERVICES MECHANICAL ENGINEER:

Project Briefing Document. Section 3 Electrical Services design guide and specifications

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

LIGHTING CONTROLS

IMPERIAL COLLEGE LIGHTING REVISION 1 REV. COMMENTS REVISED BY DATE CHECKED APPROVED

Secure connection system

Telecity. Table of Contents. Page. Section 3.2

Disabled persons toilet alarm kit from Cameo Systems

Installation & Operating Instructions

Dublin airport - Dublin, Ireland

Electronic 7 Installation Instructions

Masterseal Plus. IP66 Ingress Protected. Thrives in the Toughest Conditions.

Geberit Assisted Toilet Pre-Installation Instructions

A guide to consumer unit and wiring accessory solutions to meet the demands of general housing installations.

there s an exciting new lighting showroom & electrical department at our kilburn branch we ve bathroom showroom at our watford branch

Brunswick Grove Vale. The Three Bedroom The Floor Plans & Specification

Emergency Assist Alarm Kit Single Zone

Company Directive STANDARD TECHNIQUE : SP1N

INSTALLATION GUIDE. For products. Gardtec 370 & 581

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Product Catalogue WB Engineering Containers. fast inexpensive safe flexible certified

10A switches A switches A DP legend switches BROAD SWITCHES. 10A switches A switches

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

670 Index Automatic Air Vents, valves 304 Automatic Power Factor Correction, floor standing steel enclosure 556 Automatic Transfer Switches enclosed t

Exterior Wall & Recessed

Exit/Emergency Lighting Guide

DOOR & WINDOW ALARM INSTALLATION & OPERATING. Cat No. TG232W INSTRUCTIONS

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Fill Point, Level Gauges, and Control Range

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

Index Above Ground Drainage brackets, cast iron 228 pipes, PVC-U 211 ABS pipe & Solvent Weld Fittings 270 AC Static Inverter System, AC power supply t

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

Professional, Rewireable, Linkable LED Lighting

48 THROOPSIDE AVENUE THROOP BOURNEMOUTH DORSET BH9 3NR ASKING PRICE: 395,000 Freehold

D O M E S T I C LED. Lighting C O M M E R C I A L

Canolux LED. Petrol Station Forecourt Luminaires

GARCIA GALUSKA DESOUSA Consulting Engineers

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

Lighten. the Load! MASTERS. SUPPLY! Timeguard s range of Fused Spur Timeswitches. Savings! LIGHTING. Countdown. On Demand! ALSO INSIDE THIS ISSUE

FIRE ALARM SYSTEMS - UCL GENERAL INSTALLATION DESIGN GUIDANCE & EMPLOYERS REQUIREMENTS (Student Halls of Residences & Sleeping Accommodation)

Tyrwhitt Road Brockley 1,950,000 Freehold

Requirements of EN 1838: illuminance of 5 lx for safety equipment

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

CHALLENGER 66 INDUSTRIAL

RECESSED Spec Guide. up to 111 lm/w performance

Residential. An exciting range of stylish and quality designed residential lighting products. Residential 157

klik Lighting connection and control catalogue

Accessories. Desk Top Controls

Portland House Whitchurch, Herefordshire

Inperla An investment in a care-free future. Variable: Future-fit: Carefree:

CLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN

Fire detection and alarm

Lighting NSW / ACT / QLD / NT / VIC / TAS / SA

Fume cupboards and microbiological safety cabinets

Instruction Manual WARNINGS

AWARD WINNING CONTEMPORARY BOUTIQUE BED & BREAKFAST 875,000 FREEHOLD

EDGE PATIO HEATER. User Manual. English

E-MAL1 E-AW1 E-NEO. Malvern Electric Astwood Electric NEO Electric T E C H N I C A L & U S E R M A N U A L

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Special Types of Installation

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

Electrisaver User and Installation Instructions

Catalog Number. Notes

Arctica Solar 1500 Series Heater Installation Manual

SECTION LIGHTING CONTROLS

Section 8 Electrical.

A. This Section includes the following lighting control devices:

Installation and Operating Manual Drying Cabinet

Retreat Homes Specification Sheet

Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM

Emergency light. Safe solutions

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Accessories DESK TOP CONTROLS MODELS SPECIFICATIONS MODELS SPECIFICATIONS UNDER DESK TOP MOUNTING MINI DESK TOP CONSOLE

MANUFACTURED IN THE UK

Addressable and Conventional Fire Protection

PROJECT DATE FLANGE FINISH

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

INSTALLATION AND USER INSTRUCTION GUIDE. Model (s) Electric Heater Model No s FRER**ME2 / FSER**ME2 / FMER**ME2. ** Denotes case colour / finish

Document Information Cover Sheet

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

OPERATING INSTRUCTIONS

14 Upper Rock Gardens Brighton, BN2 1QE 695,000 Freehold

Pasture Road, Goole DN14 6EZ Offers over 180,000

2 Minimiser SE - User's

360º Surface Mount Ceiling PIR Light Controller

2 ALBEMARLE ROAD, NORWICH GUIDE PRICE 850,000

Essentials Series 4.0

SBI INFRA MANAGEMENT SOLUTIONS PVT. LTD.

EAST DEAN & FRISTON VILLAGE HALL FIRE RISK ASSESSMENT

I storm. Circular High Speed Hand Dryer. Model N2 : I storm...,. Patent Pending. Operating Instructions and Parts Manual

Transcription:

Oakdale Primary School Expansion Project Appendix C Elec Equipment Schedule HBS-SH-MEP-803 May 2017 For Peterborough City Council ver. author date checked comment P1 DH 19-05-17 TJC TENDER ISSUE 1

Ref E-01 Luminaire Schedule Description Manufacturer & Reference Comments A Recessed 600x600 flat panel luminaire with polycarbonate diffuser. Fitted with integral PIR & daylight sensor. Plateau Smart 26W LED PU16526D General teaching rooms B C Surface mounted luminaire impact & corrosion resistant polycarbonate body & cover. Fitted with integral PIR & daylight sensor. KANBY Smart 30W LED KB16108 Store rooms D Wall or ceiling mounted small circular luminaire with high efficiency opal diffuser. Fitted with integral PIR sensor. DOT LED Smart 14W LED DOT16826D Surface mounted in corridors G Recessed luminaires with injection moulded reflector finished white. include frosted inner and frosted outer drop glass, LEDs, 8W versions. G3 LED Smart 8W LED GT 15078 Entrance lobby 2

H Recessed luminaires with injection moulded reflector finished white IP65 G3 LED IP65 16W LED GT 15083 External canopy of extension and WCs EE Non-maintained illuminated emergency exit sign with ISO legend downward arrow. Exit Sign 4W LED LEX15242 Emergency exit doors / top of stairs F Wall mounted external luminaire with cast aluminium body, IP65 rated with polycarbonate cover. Cobalt 18W LED CT14504L External lighting controlled by photocell and time clock. All lighting above are examples of what is expected, the contractor may choose different fittings but must demonstrate compliance. Emergency lighting to be combined with emergency battery pack, emergency lighting to be tested via contactors and CP electronics test switch. 3

E-02 Equipment Schedule Materials Item Manufacturer Cat Nr or Type Picture 13A single switched socket outlet for cleaner s use (BSS faceplate with white rocker) Albany Plus K2958BSS Or Surface metalclad plus 13A twin switched socket outlet (BSS faceplate with WHITE outboard rockers) Albany Plus K2947BSS Or Surface metalclad plus Unswitched fused connection unit (BSS faceplate with neon) Albany Plus K9589BSS Or Surface metalclad plus Switched fused connection unit (BSS faceplate with neon) Albany Plus K941BSS Or Surface metalclad plus Secret key-switched fused connection unit Metalclad Plus K963 KO ALM Single gang faceplate for use by Data Specialist for double data point (BSS faceplate with 2Nr white Cat5e RJ45 modules) Light switches brushed stainless steel Albany Plus K182BSS + white RJ45 SINGLE- K4671BSS, 2G-K4672BSS, 3G-K4673BSS, 4G- K4674BSS Accessories on white dado trunking these should be in grey. Twin Sockets are logic plus grey - K2476GRA 4

Item Manufacturer Cat Nr or Type Picture Double data logic plus grey K182GRA + KS887WHI OHLS XLPE/SWA PVC insulated, insulated and sheathed BASEC approvals Draka or approved equal 6942XL etc. 6491X etc. 6242Y etc. Lighting switches moulded plates or surface metalclad 20 amp rated switches. Albany Plus with white rocker (Surface brushed stainless steel) Combined SwFCU & Digital Programmer Timeguard FST77 Waterproof isolating switch Round plastic conduit, super high impact, heavy gauge type and accessories Approved supplier Mita To BS EN 60947-3 Egatube range RHG range Heavy gauge, BE and galvanised steel conduit and accessories Marshall Tufflex Approved supplier CR6 range To EN50086-2-1 13 amp RCD protected socket outlet and Shaver Sockets Metalclad Plus 3 pole moulded isolator Metalclad Plus 5

Item Manufacturer Cat Nr or Type Picture 45 Amp D.P switch, moulded plate. Plates engraved as required. GET GEP4520WMC Matt Chrome Plate Finish 170 x 50mm three compartment PVC dado trunking together with all proprietary accessories e.g. angles, tees, adaptors Marco www.marcoc m.com Apollo 3 compartment Dado MTD3 Cable basket/tray / Galvanised Trunking Phillip Grahame Matrix Plug in ceiling roses Ashley Rock PCR 2000 Link H and V isolator MEM Exel range Time clocks MEM TDW2E Door bell, push and transformer Friedland D230, D723, D753 Emergency Assist alarm system Timeguard EASZK (single zone) or EACP4 (up to 4 zones) Emergency lighting test switch. CP electronics ELT10 Install to all emergency lighting circuits via contactors. Location dist. board cupboard. Furze surge protection on Main Dist board. ESP 415 M1 6

Item Manufacturer Cat Nr or Type Picture Weatherproof Touch Activated Time Lag Switches CP electronics KH3N Time delay switch for external lighting, extend time when lights are off for set time ie 10mins 7

E-03 Fixing Heights Item Main switchfuse Main Intake panel Distribution Boards Light switch Wall lights External wall lights Socket outlets - corridor Socket outlets classrooms Socket outlets office areas Socket outlets above benches Hand dryer switch Hand dryer flex outlet - Infants Hand dryer flex outlet - Juniors / DDA Hand dryer flex outlet - Adults Fan convector switch Wall thermostat Water heater switch Emergency stop button Key reset unit Fire alarm panel Break glass contacts Fire alarm sounders Class change bells TV Outlet Intruder alarm key pad or panel Distribution trunking Dado rail trunking 1150 to centre of box As shown on drawings 500 to centre of box 500 to centre of box Fixing Height (mm FFFL) 800 to centre of box / as shown on drawings 150 above worktop 2200 to centre of box 950 to centre (815mm to underside of HD) 1115 to centre (1015mm to underside of HD) 1250 to centre (1150mm to underside of HD) As shown on drawings 1500 to centre of box 1150 to centre of box 1150 to centre of box 1500 to bottom of panel 1150 to centre of box 2200 to centre of box or 200mm below ceiling, whichever is highest 2200 to centre of box In line with local socket outlet As shown on drawings If in any doubt or where equipment height is not shown then seek confirmation from the Engineer or his representative. 8

E-04 Test Certificates and Commissioning Reports for Electrical Services On completion of the works, or any defined phase or section of the works the following Test Certificates and Commissioning Reports are to be submitted and approved before the Practical Completion Certificate is issued and the area concerned can be occupied. 1 NICEIC/ECA Electrical Installation Completion Certificate 2 Energy Saving Lighting System Commissioning Report 3 Emergency Lighting System Installing Engineers Certificate 4 Emergency Lights Central Battery Commissioning Report 5 Fire Warning System Installing Engineers Certificate 6 Fire Alarm Commissioning Report 7 Security System Commissioning Report 8 Lightning Protection Test Certificate 9 Emergency Generator Commissioning Report 10 Panic / Call Alarm System Commissioning Report 11 CCTV Commissioning Report 12 TV system Commissioning Report 13 Photovoltaic System Where applicable the box is to be ticked. 9