In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Similar documents
It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

PM100V PM80V PM15V. Ex works. Depending on the specific range of application a regular ecalibration of the sensor head (PMU-V) has to be effected.

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

for relative humidity and temperature

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

THM80X Series Operation Manual Industry Degree Temp. & Humidity Transmitter V 0.1

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

HUM-M2 Humidity Sensor Module Description

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

Technical data Humidity Temperatur General data Electrical data Two designs duct version (LK) wall mounting

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Frost Protection Thermostat

for relative humidity and temperature with calibration certificates

02/11/2015

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

A and B Series Sensors for humidity and temperature for digital transfer RS485 / MODBUS-RTU or RS232

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

A and B Series Sensors for humidity and temperature for digital transfer RS485 / MODBUS-RTU or RS232

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Duct Temperature Sensors

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Complete packages with Software and Controller

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

OPTISENS TUR 2000 Technical Datasheet

HYGROPHIL H process hygrometer

02/11/2015

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

COA-2010-F Electronic CO 2

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

for relative humidity and temperature

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

QFM21... Duct sensors. Symaro. for relative humidity and temperature

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Hygro/hygrothermal transducers (hygrometric)

Hygro/hygrothermal transducers (hygrometric)

Abbeon Cal Inc. Ph: 800/ Fax: 805/

DP 300 mobile dew point instrument

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

HOBO U30 Remote Monitoring Systems

RS485 MODBUS Module 8AI

Temperature Solutions Line Card

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

ST710-KHJV.03. Wiring diagram. Product description. Temperature controller. Order number

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

HYGROMER MP 100 A Meteorology probe

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

RH and Air Temperature Sensors

Temperature Measurement Transmitters for field mounting

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

WIO200 Water In Oil measuring instrument

graphic indication of the dew point curve/ the switching behavior of the dryer over a longer period of time.

Process & TeMPerATUre UniversAl input DigiTAl MeTers

UDC100 Universal Digital Controller Specifications

Danfoss gas detection unit Type GD Heavy Duty

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

Temperature Controllers

Potential Applications

Duct Temperature Sensors

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

SIMRAD GD10PE IR GAS DETECTOR

DMFPM-2R MULTIFUNCTIONAL

gas monitoring system

HYGROMER - MP 400 A Meteorology probe

I/A Series 716C 1/16 DIN Temperature Controller

Duct Air Quality Sensors

Oxygen Sensing Solutions

Operating Manual Hand-held Measuring Device GMH 3690 GL. for Gaseous Oxygen and Temperature with Alarm Function

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Attention Items: I. Brief Introduction

TER Active Room Temperature Sensor (Controller),

DESCRIPTION MODEL 1205/1205HA NOTE

Universal controller for panel mounting Models CS6S, CS6H, CS6L

Sentry G3 Machinery Protection Monitor

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Concise catalogue Water-Industry

HRTL 96B Laser light scanner featuring background suppression for object detection and accurate positioning

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Dew point set DS 400

Humidity Measurement Technology

Transcription:

Humidity and Temperature Transmitter for High-end Meteorological Applications E33-M is optimized for reliable measurement under demanding weather conditions. Besides accurate measurement of relative humidity (RH) and temperature (T), the device calculates all additional physical quantities like dew point temperature, absolute humidity and mixing ratio. A dual heating system prevents condensation on the RH sensor, on the sensing probe and on the fi lter cap, which leads to extremely short response time and fast recovery after condensing conditions. The measuring principle with separate RH and T probes enables precise continuous measurement even at permanent high humidity. The proprietary E+E coating protects the RH sensor and its leads against corrosive and electrically conductive pollution. The probes are compatible with modern, ventilated radiation shields, like the LAM630. with radiation shield With an optional connecting cable and the EE-PCS software (included in scope of supply) the user can easily perform an adjustment or a confi guration of the outputs. Typical Applications meteorology wind turbine generators road icing warning off-shore measurements Features monolithic RH sensor precise measurement close to condensation condensation prevention through dual heating protection against pollution and corrosion calculation of additional physical quantities Monolithic Humidity Sensor The heart of is the monolithic HMC01 sensor, developed and manufactured in thin-film technology by E+E Elektronik. HMC01 combines the moisture and heating element on a single substrate. Condensation is prevented by controlled heating of the sensor. The proprietary E+E coating protects the sensor and its leads against pollution and corrosion. protective layer (coating) heated, monolithic sensor Radiation Shield In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the must be mounted inside a radiation shield. The radiation shield LAM630 is suitable for mounting onto a mast with 30-35mm diameter. Forced ventilation is provided by the control unit STEG6003. Up to 4 probes can be mounted using cable glands (Ø 18-25 mm). LAM630 STEG6003 6 v1.1 / Modification rights reserved

Network Compatibility / Ethernet Interface The optional RS485 interface (order code N) allows for building a network of up to 32 transmitters. The measurement data can be collected in a shared database and made available for all kinds of further processing. Connection Types standard plug option C03 plug option C06 plug option C08 3x M16 x 1.5 RKC 5/7 power supply+ analogue output RSC 5/7 M16x1.5 Y-splitter * RSC 5/7 RS485 network RKC 5/7 power supply+ analogue output * Siemens 6ES7 194-1KA01-0XA0 Dimensions (mm) Housing Humidity probe 135 (5.3 ) 66,5 (2.6 ) code cable length 39 (1.54 ) 93 (3.66 ) 90 (3.5 ) 12 (0.47 ) 53 (2.09 ) 24 (0.94 ) code cable length 150 (5.9 ) 6 (0.24 ) 35 (1.38 ) 24 (0.94 ) EE33-PFTM Probe material: stainless steel Adapter material: polyoxymethylene Cable gland: polycarbonate v1.1 / Modification rights reserved 7

Technical Data Measurement values Relative humidity Humidity sensor 1) heated, monolithic HMC01 Working range 1) 0...100% RH Accuracy *) (including hysteresis, non-linearity and repeatability) -15...40 C (5...104 F) 90% RH ± (1.3 + 0.3%*mv) % RH -15...40 C (5...104 F) >90% RH ± 2.3% RH -25...70 C (-13...158 F) ± (1.4 + 1%*mv) % RH -40...180 C (-40...356 F) ± (1.5 + 1.5%*mv) % RH Temperature dependence of electronics typ. ± 0.01% RH/ C (0.0055% RH/ F) Response time t 90 at 20 C (68 F) < 15s Temperature Temperature sensor Pt1000 DIN A Working range sensing head -40...180 C (-40...248 F) Accuracy C C Temperature dependence of electronics typ. ± 0.005 C/ C External temperature probe Pt1000 (DIN A) Outputs 2) Two freely selectable and scaleable analogue outputs 0-1V -1mA < I L 0-5V -1mA < I L 0-10V -1mA < I L 4-20mA R L < 500 Ohm 0-20mA R L < 500 Ohm Digital interface optional: RS485 Max. adjustable measurement range 2)3) min. max. Unit Humidity RH 0 100 % RH Temperature T -40 (-40) 180 (248) C ( F) Dew point temperature Td -40 (-40) 100 (212) C ( F) Frost point temperature Tf -40 (-40) 0 (32) C ( F) Wet bulb temperature Tw 0 (32) 100 (212) C ( F) Water vapour partial pressure e 0 1100 (15) mbar (psi) Mixture ratio r 0 999 (9999) g/kg (gr/lb) Absolute humidity dv 0 700 (300) g/m 3 (grf 3 ) Specific enthalpy h 0 2800 (99999) kj/kg (Btu/lb) General Supply voltage 8...35V DC 12...30V AC Current consumption - 2x voltage output for 24V DC/AC: typ. 40mA / 80mA - 2x current output typ. 80mA / 160mA System requirements for software WINDOWS 2000 or later; serial interface Housing / protection class Polycarbonate / IP65 Cable gland M16 x 1.5 Electrical connection screw terminals up to max. 1.5mm² (AWG 16) Working and storage temperature range of electronics -40...60 C (-40...140 F) Electromagnetic compatibility according to EN61326-1 EN61326-2-3 ICES-003 ClassA Industrial Environment FCC Part15 ClassA 1) Refer to the working range of the humidity sensor. 2) Can be easily changed by software. 3) Refer to accuracies of calculated values (www.epluse.com/feuchtemessung). *) The accuracy statement includes the uncertainty of the factory calibration with an enhancement factor k=2 (2-times standard deviation). The accuracy was calculated in accordance with EA-4/02 and with regard to GUM (Guide to the Expression of Uncertainty in Measurement). 8 v1.1 / Modification rights reserved

Working Range Humidity Sensor Relative humidity [%RH] The grey area shows the allowed measurement range for the humidity sensor. Operating points outside of this range do not lead to destruction of the sensor, but the specified measurement accuracy cannot be guaranteed. Temperature [ C] Connection Diagram Scope of Supply - Transmitter according to Ordering Guide - Operation Manual - Inspection certificate according to DIN EN 10204-3.1 - Cable connector RKC 5/7 for customer assembly, only for option C03 or C08 - Cable connector RSC 5/7 for customer assembly, only for option C06 or C08 - Y-junction for network connection, only for option N or C08 - M16 cable gland, only for option C03, C06 or C08 Accessories / Replacement Parts (For further information, see data sheet Accessories ) - PTFE stainless steel filter HA010114 - Exchange membrane for PTFE stainless steel filter HA010114ME - Stainless steel grid filter HA010109 - Interface cable for plug option C06 HA010311 - RS485 Kit (HW + SW) for network HA010601 - Mounting set for mast with Ø 34-54 mm HA010213 - Radiation shield LAM630 with control unit HA010508 - Calibration-Kit see data sheet Humidity Calibration Kit - Configuration adapter see data sheet EE-PCA - E+E Product Configuration Software EE-PCS (download at www.epluse.com/configurator) v1.1 / Modification rights reserved 9

Ordering Guide Hardware Configuration Software Configuration EE33-PFTM Filter PTFE stainless steel filter 2 Cable length 1 m 01 2 m 02 Probe length according to Dimensions 2 Interface Plug Output 1 RS485 cable glands N 1 plug for power supply and outputs C03 1 cable gland / plug for C06 2 plugs for power supply / outputs and RS485 network C08 Relative humidity RH [%] A Temperature T [ C] B Dew point temperature Td [ C] C Frost point temperature Tf [ C] D Wet bulb temperature Tw [ C] E Water vapour partial pres. e [mbar] F Mixing ratio r [g/kg] G Absolute humidity dv [g/m³] H Specifi c enthalphy h [kj/kg] J Output 2 same choice as output 1 A - J Type of output signal Measured value units T-scaling (T / Td / Tf / Tw) for output 1 + 2 0-1V 1 0-5V 2 0-10V 3 0-20mA 5 4-20mA 6 metric / SI non metric / US E01-40...60 002-30...70 008-20...80 024 Order Example EE33-PFTM2022N/AB3-002 Hardware Configuration: Software Cofiguration: Filter: PTFE stainless steel filter Output 1: Relative humidity Cable length: 2m Output 2: Temperature Probe length: see dimensions Type of output signal: 0-10V Interface: RS485 Measured value units: metric / SI Plug: cable glands T-scaling: -40...60 C 10 v1.1 / Modification rights reserved