Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Similar documents
Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

City of Duluth Festival Center 04/25

Santanu Prasad Datta (Student) P. K. Das & S. Mukhopadhyay

Refrigerant Mass and Oil Migration During Start-up Transient

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Development of Energy Efficient R-134a Automotive Air Conditioning System Using Internal Heat Exchanger

Heating and Air-Conditioning Testing II. Climatic Test Bench

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump

Vehicle Level Heating and Air Conditioning Description and Operation A/C System - Manual. A/C System - Manual

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Climate Control System

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Low GWP Refrigerants for Air Conditioning Applications

1998 Expedition/Navigator Workshop Manual

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

System Modeling of Gas Engine Driven Heat Pump

TEST REPORT #47. System Drop-in Test of R-32 and Refrigerant Blends ARM-71a, HPR2A, L-41-2 and DR-5A in a Five-Ton R-410A Rooftop Packaged Unit

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

A/C Cooling Load calculation and measurement

Steady and Cyclic Performance Testing of Packaged R-410A Units

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

1.1 This section applies to air handling units for HVAC Systems.

EHH SERIES DRAW THROUGH FAN COILS CFM

Prepared by: (415) With. High. Prepared for: Final Report June 27, Contributors: Tom. Me!

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

THERMAL ICE STORAGE: Application & Design Guide

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

Method to test HVAC equipment at part load conditions

For an administrative fee of $9.97, you can get an un-locked, printable version of this book.

Fundamentals of Psychrometrics. By James L. Murphy, Colorado Building Environments Sales Engineer

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

TEST REPORT #53. System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton R-410A Rooftop Packaged Unit

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

HFO-1234yf Performance in a Beverage Cooler

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

Multiple split-system air-conditioners and air-to-air heat pumps Testing and rating for performance

Heat pump supplemental heating system for motor vehicles

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

Technical Development Program

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

Getting Started. 1 Please visit for more information.

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

SERVICE ASSISTANT OVERVIEW FDSI Online Training

Interim Report for the Period thru February 15, 2018 Submitted to Department of Business and Professional Regulations Office of Codes and Standards

Pharmaceutical Facility Design

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

AHRI Certification Program Scopes - COOLING

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

TEST REPORT #12. System Drop-In Tests of Refrigerant Blends N-13a and AC5 in Bus Air- Conditioning Unit Designed for R-134a

ShuttleAIRE Systems. A complete range of HVAC systems for small and medium sized vehicles.

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

Product Data. Features/Benefits. GEMINI 38AKS Commercial Air-Cooled Split Systems 50/60 Hz. 25 to 40 Nominal Tons (82.8 to 127.

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Heat Recovery Units. Heat Recovery 1

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

HEATING AND AIR CONDITIONING

Performance Measurement of R32 Vapor Injection Heat Pump System

Scroll Compressor for Mobile HVAC/R Application

RIGID DC LIQUID CHILLER

TESTS OF ADSIL COATING

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40


Instructors: Contact information. Don Reynolds Doug McGee Factory Tech Support

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

PERFORMANCE EVALUATION OF GAS COOLER/ CONDENSER FOR CO2 REFRIGERATION SYSTEMS

2. CURRICULUM. Sl. No.

AIR CONDITIONER PERFORMANCE RATING

How to ensure Thermal Comfort in buildings with CFD

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Test Report No.: Page 2 of 14

Comparative Performance of HFO Blends in a Condenser

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

AUTOMOTIVE HEATING AND

Designing Energy Efficient Outdoor Air Systems

Energy Use in Refrigeration Systems

CTI Sponsored Educational Program

Emerging Technologies: VFDs for Condensers. Douglas T. Reindl Director, IRC University of Wisconsin-Madison. University of Wisconsin-Madison

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

The following report is prepared and published by:

ANSI/AHRI Standard Standard for Performance Rating of Indoor Pool Dehumidifiers

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Transcription:

SAE Alternate Refrigerant Cooperative Research Program Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000 To: Alternate Refrigerant Task Force Members From: Ward Atkinson This is the final review of supplied comments. At this point it is impossible to add any additional changes without considering the actual testing capabilities of the selected test facility and requirements of the technical experts that will conduct the test activity. Therefore, this document is being forwarded to the CRP Alternate Refrigerant Core Group for their review and modifications as deemed necessary by the Expert Advisors. Program Target The purpose of these bench tests is to investigate the performance and efficiency of a production HFC-134a automotive refrigeration system with an enhanced R134a refrigeration cycle and other alternate refrigerant cycles. The test cycles reflect vehicle users demands for hot climate conditions as well as middle and low ambient load conditions. The test conditions cover an estimated average load profile on these systems allowing comparison of the system COP for an estimated annual supplementary power consumption (fuel consumption) for a typical vehicle driving cycle and climate condition. This document is a collection of test procedures and not all conversion information (English - metric) values have been included. The value indicated in the document prevails until conversion values are supplied. Facility Requirements Test Chambers The test procedure requires that there are three separate temperature control chambers containing the component to be tested. Each component shall be mounted in a separate temperature/humidity controlled chamber. Refrigerant flow connections between component test chambers (evaporator, condenser/gas cooler, compressor) shall not exceed 6 feet (total hose/rigid pipe length) and should be the same length for all test comparisons. HFC-134a systems are more sensitive to pressure drop due to lower operating pressures. The hose/pipe shall be outside dia. (OD) ¾ inch (19mm), inside hose dia. (ID) 5/8 (16mm) and shall be limited to a length of 6 feet (1.8m) in distance from the compressor inlet fitting and the evaporator outlet fitting for each system tested. Comments SAE Alternate Refrigerant Cooperative Research Study 1

Compressor Chamber The chamber shall have a variable speed drive motor (internal or external) to maintain the compressor at the various speeds and measure compressor torque requirements. (600 3500 rpm compressor speed) The chamber shall be maintained at the specific operating temperature ±3% o C. and compressor speed conditions ±10 rpm or less. Evaporator Chamber The chamber shall be maintained at the specific temperature (±0.6 o C) and humidity test conditions (±3% RH). 1. The evaporator shall be mounted, in the test chamber, flat face to the airflow and sealed on the inlet side. The evaporator outlet surface (cold side) shall have 4 rows of 4 thermocouples per row for a total of 16 equally spaced temperature locations. 2. The outlet side of the evaporator shall have a transition duct 16 inches, 406 mm in length from the evaporator outlet surface that is reduced to represent the restriction of 4 panel outlets. At 300cfm the pressure drop (dry core fin) of the duct system shall be 200 Pa +/-25 Pa. The outer surface of the duct should be insulated. Duct outlet air temperature measurement shall consist of a temperature grid located 25mm rearward of the transition duct exit point containing 4 thermocouples. The test chamber airflow must be controllable from 60 CFM, 28.3 l/s, to 300 CFM, 141 l/s. Electrical heater and humidifier should compensate for sensible and latent capacity of the evaporator at steady state conditions. Evaporator inlet and outlet static pressure measurements should be made according to ASHRAE standards. Airflow rate shall be measured following ASHRAE/AMCA standards. The final data reading shall be taken after the system has stabilized. After the system has operated for 30 minutes and data recorded, two additional data points at least 5 minutes apart shall be recorded to verify stabilization. Collection and measurement of evaporator condensate (time vs. collect weight should be done with scale or load cell with no less than 0.1g accuracy. There should be agreement between three capacity balances (refrigerant, air and chamber balance. The main balance of refrigerant- and air side shall be within 3%. The chamber could be compromised. Comments SAE Alternate Refrigerant Cooperative Research Study 2

Secondary loop system The heat exchanger flow rates (airflow or liquid) and temperatures are applicable to secondary or split systems that provide cooling to the passenger compartment should be controllable from 60 to 300 CFM on the airside and 25 to 500 USgal/hr, 96 to 1920 l/h, on the coolant side. Vehicle Front End Chamber The chamber shall be maintained at the specific temperature (±0.6 o C). The airflow must be controllable from 900 CFM, 425 l/s to 2,800 CFM (1322 L/m) The heat exchanger shall be mounted in a front-end module consisting of an enclosure housing a typical vehicle inlet grille, a support assembly that a vehicle engine coolant radiator (airflow restriction only) is attached and electric engine cooling fans. A panel shall be mounted downstream (behind) the cooling fan/fans to simulated engine airflow restriction. All other measurements should be done same as in the evaporator Test chamber System Performance Requirements Prior to conducting any test sequences as required in Phase III Stabilized conditions a refrigerant charge determination as required in Phase I and Phase II Evaporator Freeze Protection shall be completed. Phase I Charge Determination for HFC-134a systems. CO 2 and Secondary loop systems may require a modified method. The test team shall establish the system operating refrigerant charge to be used during the testing. This refrigerant charge amount shall be used for all test sequences. Overcharge can cause problems under high load conditions during idle. The refrigerant overcharge amount should be established by the test team specialist. The CO 2 specification for purity shall be industrial beverage grade. This is used to carbonate drinks, is the lowest cost, readily available and because of cost will be the grade used by the service industry. CO 2 specification Industrial Grade: Minimum purity 99.5% Moisture 120 ppm Dew Pt. Colder than -40 F UN Number UN1013 CAS Number: 124-38-9 Comments SAE Alternate Refrigerant Cooperative Research Study 3

1. Ambient 104 F, - 40 C 40% R.H 2. 2000 compressor RPM 3. Start at 0.5 kg. and increment in 0.05 kg. 4. Record the appropriate system pressures and temperatures required identifying the systems critical refrigerant charge value. 5. After establishing test stand refrigerant optimum charge value all testing shall be run at 0.2 Kg above optimum charge value. Phase II Evaporator Freeze Protection Ambient 90 F - 32 C 50% r.h. 110 grains of moisture per pound of dry air 76 F (24 C) WB 1. Evaporator freeze protection test. Per Procedure SAE J1659 par. 5.0 except as modified for test chamber application. Testing of Evaporator Control for freeze protection Testing of Replacement Evaporator freeze-up protection control setting changes must be established prior to testing. This includes pressure switches, electronic and mechanical temperature switches for compressor clutch operation, and control systems for variable displacement compressors. The purpose of this test is to establish the requirements that will assure that the mobile A/C system operation under high moisture loads will not result in loss of system performance due to evaporator core icing reducing system air flow. Test Conditions The A/C system shall be operated with the system blower setting on low position (60 cfm), at an ambient of 90 F - 32 C, at 50% relative humidity. The compressor shall be operated at a constant speed of 2,500 rpm with the condenser/gascooler airflow being 2,800 cfm for 2 hours. The air pressure differential between the evaporator core inlet and the evaporator outlet shall be measured with a device that will indicate the pressure drop in Pa (mm) of water. The differential pressure shall be recorded every 5 min for the 2 hour period. After the first 15 min of operation, the pressure differential shall not change more than 10% during the remaining 105-min of the test. When a significant change of pressure occurs, it is an indication of evaporator ice build-up, reducing system airflow, which indicates an incorrect evaporator freeze control setting. If the system exhibits evaporator ice build-up, the control setting shall be changed and the test re-run so that no excessive loss of system air flow occurs. All data shall be recorded every 5 min during the test period. A/C system blower voltage and amps shall be recorded. If a compressor cycling clutch system is used for evaporator control, the compressor cycle rate shall not exceed the 6 cycles per minute. Comments SAE Alternate Refrigerant Cooperative Research Study 4

Phase III Stabilized Performance The HFC-134a system is first run as baseline and a final recheck for test and equipment validation is made after completion of the test series. Each alternate refrigerant system shall run the same test conditions. When other alternate refrigerant systems are tested the first test sequence will be conducted at the indicated compressor speeds. If the evaporator outlet temperature is not comparable with the HFC-134a test for the 113 F, - (45C ) 27% R.H. 116 grains of moisture per pound of dry air 82 F (28 C) WB a second series of tests are required. The HFC-134a baseline run at an ambient of 113 F, - (45C ) 27% R.H. 116 grains of moisture per pound of dry air 82 F (28 C) WB at the indicated compressor speeds (900, 1500, 2500 rpm) average and the evaporator outlet air temperature is used as baseline. The average evaporator outlet air temperature surface (cold side shall have 4 rows of 4 thermocouples per row for a total of 16 equally spaced temperature locations 5mm from the cold side evaporator surface) defines the average outlet air temperature directly after the evaporator. Each alternate refrigerant system must have a comparable evaporator outlet temperature at the 900-rpm test condition. If the temperature is not comparable a second series of tests are required to compare the alternate refrigerant to the HFC-134a system. Compressor speeds are to be adjusted, faster or slower, to obtain a comparable evaporator outlet temperature +/- 1 C of the base HFC-134a system at 900 rpm test condition. With the new compressor speed established the changed (faster or slower) speed will be run for all additional data points. (eg. Equal temperature required an increase compressor speed of 350 rpm) The new series of data points will be run at the percentage of change required, eg. 1,250 idle, 2,083 low speed and 3,472 high speed. These adjusted speeds shall be run at all test conditions. 6. Ambient 113 F, - (45C ) 27% R.H. 116 grains of moisture per pound of dry air 82 F (28 C) WB Test condition to be run = High Load Stabilized idle Stabilized low speed Stabilized high speed Idle and rapid acceleration evaluation From previous stabilized point 1 - within 3 second decrease compressor to idle speed 2 - idle compressor for 30 seconds 3 - within 10 seconds increase compressor speed to 2000 rpm. Comments SAE Alternate Refrigerant Cooperative Research Study 5

Note this test condition requires discussion regarding what data are to be recorded to determine system stability. Evaporator and condenser/gas cooler airflow must be established (based upon test stand capability) for the different conditions. 7. Ambient 95 F, - (35 C ) 45% R.H. 112 grains of moisture per pound of dry air - 77 F (25 C) WB Test condition to be run = High Load Stabilized idle Stabilized low speed Stabilized high speed 8. Ambient 77 F, - (25 C) 65% R.H. 90 grains of moisture per pound of dry air - 68 F (20 C) WB Test condition to be run = High Load and Low Load Stabilized idle Stabilized low speed Stabilized high speed Idle and rapid acceleration evaluation From previous stabilized point 1 - within 3 second decrease compressor to idle speed 2 - idle compressor for 30 seconds 3 - within 10 seconds increase compressor speed to 2000 rpm. Note this test condition requires discussion regarding what data are to be recorded to determine system stability. Evaporator and condenser/gas cooler airflow must be established (based upon test stand capability) for the different conditions. 9. Ambient 59 F, - 15 C 80% R.H. 60 grains of moisture per pound of dry air - 56 F (13 C) WB Test condition to be run = High Load and Low Load Stabilized idle Stabilized low speed Stabilized high speed Comments SAE Alternate Refrigerant Cooperative Research Study 6

Test Conditions For ambient conditions of 113 F and 95 F the High Load requirements shall be run. For ambient conditions of 77 F and 59 F both the High Load and Low Load test points shall be run. Test Condition High Load Idle System evaporator airflow 230 CFM, 109 l/s, Condenser/gas cooler 900 CFM, 425 l/s Test condition 1 Ground heat and engine compartment air recirculation can increase the condenser / gascooler air inlet temperature at Idle conditions. Condenser/ gas cooler inlet temperature to be 15 C above test ambient at idle condition due to ground heat and engine compartment air recirculation For investigating purpose an increase of 25 C at gascooler/condenser inlet should be also considered This is not be used for efficiency calculation. Test Condition 2 Due to varying wind direction and velocity, and changing ground surfaces temperature (rain, sun, night) the inlet temperature can be equal to ambient. Condenser/ gas cooler inlet temperature to be the same as test ambient at idle condition. Compressor - 900 rpm Low speed System evaporator air flow 275 CFM, Condenser/gas cooler airflow 1,800 CFM, 850 l/s, Compressor 1,500 rpm High Speed System evaporator airflow 275 CFM, Condenser/gas cooler airflow 2,800 CFM Compressor 2,500 rpm Test Condition Low Load Idle System evaporator airflow 60 CFM, Condenser/gas cooler 900 CFM, 425 l/s Condenser inlet temperature to be 15 C above ambient at idle condition due to ground heat and engine compartment air recirculation Comments SAE Alternate Refrigerant Cooperative Research Study 7

Compressor - 900 rpm Low speed System evaporator air flow 60 CFM, Condenser/gas cooler airflow 1,800 CFM, 850 l/s, 51cmm Compressor 1,500 rpm High Speed System evaporator airflow 60 CFM, Condenser/gas cooler airflow 2,800 CFM Compressor 2,500 rpm Test Conditions All test conditions unless otherwise specified must meet following requirements. Temperature ± 0.6 C Humidity ± 3% Airflow ± 3% Total chamber system air flow (closed loop system) shall be measured by a calibrated orifice or equivalent device located within the chamber Compressor speed ± 10 rpm or less. All system electrical power consumption, e.g. Pumps or motors (engine cooling fan(s)) required for the refrigerant system to operate shall be included in all energy calculations. Additional refrigerant circuit components not identified as an evaporator, condenser/gas cooler and compressor, such as but not limited to as, heat exchanger, oil separator or control shall be identified as follows: Component function and physical size Component weight Instrumentation Maximal allowable instrument uncertainties: Pressure transducers: Pressure transducers ± 5 kpa for R134a and ± 10 kpa for CO 2 Temperature: 0.2 o C (0.4 o F) Torque: 0.5% Compressor speed: 1rpm Dew point: 0.2 o C (0.4 o F), Relative humidity consequence Air flow rate nozzles with differential pressure transducers max 0.3% of reading Refrigerant flow: 0.2% of reading Oil concentration: 0.5% Water condensate weight measurements: 0.1g for total flow rate. Watt transducers: 0.3% of reading Refrigerant flow devices shall have minimum restriction and equipped with a visual device to determine the state (vapor or liquid) of the flow being measured. Comments SAE Alternate Refrigerant Cooperative Research Study 8

Components (Heat Exchanger) Physical Size Limitations To provide comparable packing size restrictions the evaporator, condenser/gas cooler maximum dimensions are identified for the test parameters. The dimensional limits are an average of industry components for an intermediate size vehicle. Evaporator The evaporator size (exchanger face area excluding header/end tanks) shall not exceed 75 mm depth and a total effective face area of 64,000 sq. mm. 1. The mounting surface of the evaporator shall be sealed on the inlet side (warm airside). 2. The evaporator outlet surface (cold side) shall have 4 rows of 4 thermocouples per row for a total of 16 equally spaced temperature locations. 3. Airflow to be measured with a nozzle. 4. Dry bulb and dew point to be measured downstream of the nozzle within 1.0 meter of evaporator inlet 5. Dry bulb and wet bulb temperature to be measured at outlet of evaporator (HVAC) within a distance of 300 mm 6. Refrigerant evaporator inlet outlet temperatures/pressures. Thermometers (thermocouples) for refrigerant temperatures should be inserted in the refrigerant and not restrict flow. 7. Measure chamber airflow, using ASHRAE/ANSI recommended procedure, evaporator inlet static pressure and pressure drop. Condenser/gas cooler The condenser/gas cooler shall be mounted in a simulated front end, within ½ inch of the radiator inlet surface, consisting of an enclosure including a grille, radiator and cooling fans. (Baffle restriction to simulate downstream restriction of engine.) The condenser/gascooler size (exchanger face area excluding header/end tanks) shall not exceed a depth of 20 mm. and an effective total face area of 318,000 sq. mm. Comments SAE Alternate Refrigerant Cooperative Research Study 9

1. Refrigerant condenser inlet outlet temperatures/pressures. shall be measured in the same manner as on the evaporator side. (Inserted in ref. Flow) 2. Refrigerant flow rate shall be determined with the instrument as described in Test Conditions If refrigerant flow rate is measured when in (liquid state) (typical) special care should be taken that there is no flashing before or in the meter. 3. Measure inlet and outlet air temperatures with a corresponding 5 row, 5 locations (25) point grid Compressor The compressor shall be mounted in a closed temperature controlled chamber. (maintained at 110 C +/- 5 C) Chamber temperature shall be measured 100mm (4in) above the compressor. Compressor body temperature is to be measured near discharge port. 1. Refrigerant compressor inlet outlet temperatures/pressures. Thermometers shall be inserted in refrigerant flow. 2. Compressor torque measurements shall be made directly on the shaft. If it is not possible and transmission (pulley) losses are the part of the measured value calibration should be provided. 3. Compressor speed shall be measured with tachometer within ±1rpm. A/C system control device: The method and type of evaporator and compressor pressure control shall be identified. Any external energy required to operate these controls shall be included in the total system energy requirements Data Collection/reduction Measure Compressor torque and rpm Calculate Compressor Power Measure evaporator inlet humidity and temperature Calculate inlet enthalpy Measure evaporator outlet humidity and temperature Calculate outlet enthalpy Measure air flow rate Calculate evaporator capacity on the air side Measure condensate and compare it to difference in inlet and outlet humidities times air flow rate Measure evaporator inlet refrigerant pressure and temperature Calculate inlet refrigerant enthalpy Measure evaporator outlet refrigerant pressure and temperature Calculate outlet refrigerant enthalpy Measure refrigerant flow rate Measure oil concentration in refrigerant Calculate evaporator capacity on the refrigerant side Comments SAE Alternate Refrigerant Cooperative Research Study 10

Compare refrigerant and air sides Calculate superheat and supercool Evaporator and condenser airflow pressure drop is to be recorded at all test conditions to determine static pressure restriction and work load requirements. Compare refrigerant and air sides Evaporator and condenser airflow pressure drop is to be recorded at all test conditions to determine static pressure restriction and work load requirements. Measure Gascooler/condenser outlet refrigerant pressure and temperature to check its performance, especially R134a condenser must be checked. Measure Gascooler/condenser inlet refrigerant pressure and temperature to check its performance, especially R134a condenser must be checked. Measure compressor outlet refrigerant pressure and temperature (Only R134a is OK) Measure compressor inlet refrigerant pressure and temperature (Only R134a is OK) Measure electrical input to the evaporator chamber Measure humidity input to the evaporator chamber Calculate COP for each test condition by dividing capacity by shaft power. Plot COP and evaporator capacity for each test condition Repeat the same procedure for the front end HX except for humidity. Add compressor power to the evaporator capacity and compare it to front end HX (condenser or gas cooler) COP = air side cooling capacity (heat transfer) / total system power required to attain that performance COP = Q evap / Total System Power Required to deliver Q evap Where: Q evap = air mass flow x air enthalpy change across evaporator (Comment: (Wertenbach) For Q evaporator calculation the air inlet temperature to be measured after the external blower device. The blower motor is an additional heater. The power consumption of this motor depends on the airside pressure drop of the evaporator (fin pitch differences). This effects the effective cooling capacity, if temperature measurement is only before/after evaporator: Qo eff=qeva-pblower motor. To eliminate this effect, is better to control the air inlet of evaporator as constant (defined) temperature after the blower, and not influenced by external blower motor). Comments SAE Alternate Refrigerant Cooperative Research Study 11

Instrumentation: 1. All refrigerant inlet and outlet temperatures/pressures in an internal heat exchanger shall be measured in the same manner as on the evaporator side. (Inserted in ref. Flow) 2. All refrigerant and coolant flow inlet and outlet temperatures/pressures in a liquid/refrigerant heat exchanger shall be measured with a minimum of 3 thermocouples inserted the liquid flow. The liquid volume flow should measured by a liquid flow meter. - humidity measurements and condensed water recovery (for thermal balance) - as air outlet temperature homogeneity at the evaporator is an issue for HVAC design. This must be identified for each system with IR thermograph camera measurements or temperature sensors. - for indirect system. Both primary and secondary loop must be equipped. Test chambers: - Relative altitude of each component must be take into account and harmonized (for example: receiver versus condenser) - Temperature of the compressor test chamber must be specified with a conditions T compressor chamber = T outside air + a defined delta t. Data collection/ reduction: - For each system COP must be well defined. Engine shaft power to generate the electrical power for the liquid pump, additional refrigerant control required for the system. - Measurements for cooling power? - Target as to be defined concerning thermal balance to validate the experimental point. A reasonable target for thermal balance accuracy is 3%. This will impose accuracy of each measurement techniques Component and Test Verification The Expert Advisor team will provide an overview and verification of the systems tested, verifying the components as being representative of production (capable) state of art systems. This may also include verification by dissipation of the components prior to being used for test. They will also validate the testing procedures, accurate data collection and reporting. Comments SAE Alternate Refrigerant Cooperative Research Study 12