AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

Similar documents
AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

HYDRONIC RESIDENTIAL

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

COMFORT CHILLERS. AIR SOURCE CHILLERS WITH SCREW COMPRESSORS, FROM 140 TO 1710 kw R513A. climaveneta.com

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

PROCESS CHILLERS. AIR SOURCE CHILLERS WITH SCREW COMPRESSORS, FROM 140 TO 1710 kw R513A. climaveneta.com

COMFORT APPLICATION HYDRONIC TERMINALS ELEGANCE AND DESIGN FOR YOUR RESIDENTIAL COMFORT

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Modular Air-cooled Chillers

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

AIR COOLED CHILLERS WITH INVERTER SCREW COMPRESSORS AND HFO REFRIGERANT FROM 377 TO 1463 kw

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Neosys Product catalogue

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 81,1 TO 182 kw, AIRFLOW FROM TO m 3 /h

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

COMPACT AIR HANDLING UNIT

COMFORT HYDRONIC TERMINALS

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Be sustainable while protecting your business

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Air cooled industrial chillers

PRODUCT GUIDE

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98


2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

AIR SOURCE CHILLERS WITH SCREW COMPRESSORS, FROM 235 TO 1463 kw

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

Blue Box Epsilon Echos +

NX-N. Climaveneta Technical Bulletin NX_N_0604T_1204T_201211_EN

Galletti Water chillers and heat pumps catalogue

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

CRIMSON & CRIMSON MAX

H4T R410A. refrigerant

Air source chillers with screw compressors, from 289 to 1710 kw

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

LZA High efficiency air to water heat pumps with HP compressor

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

AIR SOURCE CHILLERS WITH SCREW COMPRESSORS, FROM 289 TO 1710 kw

LZT High efficiency air to water heat pumps with E.V.I. compressors

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

21,8 222 kw COOLING 25,2 236 kw HEATING

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

1

nemo a hp rcgroupairconditioning R410A

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Reliability and extended operation

Air Cooled Chillers & Heat Pumps WinPACK HE-A

kw COOLING kw HEATING

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

ARV.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

FOCS. Climaveneta Technical Bulletin FOCS_0751_1301_200909_GB. Air-cooled water chiller with helical fans kw

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

PYXIS U PYXIS U. rcgroupairconditioning

Precision air conditioners with inverter technology for stable room conditions

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

AWR MTD2 XE. Versions

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

KELVIN Clim F497. Kelvin air conditioning

ELFOEnergy Extended Inverter

pyxis u pyxis ua NEW rcgroupairconditioning

ELFOEnergy Duct Inverter

44,9 202,0 kw. technicalcatalogue

Aquaflair TRAC-TRAF-TRAH

FRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

BRAN. Climaveneta Technical Bulletin BRAN_0011_0121_201211_EN ,6-31,3 kw. Reversible unit, air source for outdoor installation

PROCESS CHILLERS. AIR SOURCE CHILLERS WITH SCREW COMPRESSORS, FROM 235 TO 1463 kw. climaveneta.com

Transcription:

COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com

COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation from 4,3 to 35,1 kw Outdoor unit for cold water production, with hermetic rotary compressors with variable speed (Inverter Driven) in a single-circuit configuration using R410A refrigerant, air side heat exchanger with copper tubes and aluminum fins, water side steel brazed plate heat exchanger. The unit is equipped with electronic expansion valve and integrated hydraulic module as standard. A flexible and reliable unit that adapts to the actual load conditions thanks to the accurate temperature control combined with the use of inverter technology. The precise design and the use of innovative variable speed motors (inverters) ensures a high level of energy efficiency both at full and partial loads. THE CHILLER FOR EVERY NEED COMFORT APPLICATIONS System efficiency The unit is designed with a system approach: all components are set in sinergy according to a proprietary logic to maximise the efficiency of the unit. High efficiency at partial loads High values of seasonal efficiency thanks to the modulation of the compressor with DC inverter technology so that the unit provides the exact thermal power in correspondence with the actual needs of the building. High efficiency which translates into reduced energy consumption throughout the unit s working period. a Commercial premises. a Infrastructure for entertainment. a Offices. a Hotels and Resorts. ErP READY a Health facilities. a Centralized systems that can be implemented with cascade systems. A WIDE RANGE FOR EVERY NEED i-bx 004-035 004 006 008 010 013 010 013 015 020 025 030 035 0 10 20 30 40 Cooling capacity [kw] Power supply 230/1/50 Power supply 400/3/50 73% of the time, the chiller works to meet half the building s cooling load. In fact, only one working point is no longer an expression of the efficiency of the unit, the focus is on seasonal efficiency. SEER SEER 2021 The ErP directive was introduced with the aim of reducing the energy consumption of products through an environmentally friendly design. A new indicator of seasonal energy efficiency has therefore been defined, the Seasonal Energy Efficiency Ratio (SEER), to allow users of cooling systems to easily compare the efficiency of the chiller. *average values 4,10 4,53* 02/03

02/03 EASY INSTALLATION PROTECTED IN EVERY CONDITION The i-bx units are packaged mono-block chillers that are particularly easy to install. The pipe connections are hydraulic; therefore it is not necessary to carry out the typical procedures of direct expansion air-conditioning systems (vacuum, refrigerant topping up, etc.). The hydraulic components are all contained inside the unit: circulator with EC motor, expansion tank, safety valve, relief valve, flow switch and net type filter (not installed). Dedicated algorithms prevent the formation of ice by: 4activating the electrical resistance on the plate heat exchanger. 4activating the pump according to the outdoor air temperature. 4enabling the inside of the flow switch due to lack of flow. The unit is also designed to work with brine-free mixtures up to a leaving temperature of -8 C. NIGHT FUNCTION EXTENDED OPERATING LIMITS Noise levels are reduced by modulating the fan speed and the frequency of the compressor. Full load operation is guaranteed up to 45 C outside air temperature during the summer season, and up to -10 C outside air temperature during the winter season. The unit is able to produce chilled water with evaporator outlet temperatures from -8 C to 18 C. Full load operating limits DYNAMIC WATER SET POINT 20 18 EER The dynamic control of the water supply temperature according to the outdoor air temperature greatly increases the comfort and energy efficiency of the system. 8 6 Leaving water temperature ( C) 15 10 5 0-5 -8 4-10 25 45 50 2 Air temperature ( C) 0 Outdoor air temperature Variable temperature set-point Fixed temperature set-point CASCADE SYSTEMS MANAGEMENT Up to 4 units with the same power can be connected in cascade to cover high thermal requirements (optional configuration). 4Managed in master slave mode, with the master unit that takes care of processing the information and then transmitting it to the slave units. 4Accurate sizing of the system and precise modulation of the power supplied maintaining high performance. 4,4-36,5 kw 36,5 kw 4,4-36,5 kw 73 kw 4,4-36,5 kw 109,5 kw 4,4-36,5 kw 146 kw

COMFORT CHILLERS TECHNOLOGICAL CHOICES Structure Structure consisting of a base and self-supporting hot galvanized steel panels, painted with RAL 7035 polyester powders. 4Solidity and robustness. 4Maximum accessibility for service and maintenance operations. Fans Axial fans with continuous regulation of the speed, which improves the air distribution obtaining low consumption and minimizing the sound level. Coil 4Condenser with copper pipes and aluminum fins. 4Coil protection grids as standard up to size 015. NADISYSTEM control 4Setting the water set point with fixed or dynamic value with the Climatic curve. 4Antifreeze protection depending on the water temperature and outside air temperature. NADICompact 4Functional keys 4Graphic display and icons Allows quick and easy consultation and intervention on the unit by means of a multi-level menu. 4Weekly programming up to 6 timeslots. 4Digital input for night function (Night mode). 4Remote connectivity to BMS systems via serial card (accessory). 04/05

INTEGRATED HYDRONIC UNIT EC PUMP 04/05 All the hydraulic components for the installation of the unit are already included without increasing its size. 4EC pump, brushless motor with electronic switching to guarantee low consumption and high system efficiency. 4Water flow switch, to protect the exchanger for low water flows. 4Safety valve. 4Expansion vessel. 4Air release valve. 4Net type filter, not mounted but supplied with the unit. Evaporator 4 Brazed plate heat exchanger made of AISI 316 stainless steel, externally coated with an anti-condensation mat in closed cell neoprene (CFC and HCFC-free). 4 Thermostatic electric heater to protect against ice formation on the inside. 4 Low pressure drops and optimized heat transfer. Refrigerant circuit 4Electronic expansion valve as standard: - optimized refrigerant flow; - effective temperature control; - fast regulation and high efficiency. ELECTRONIC EXPANSION VALVE Compressor Mitsubishi Electric compressors, synonymous with quality, reliability and high performance at partial loads. 4 Compressor installed on rubber anti-vibration mounts and soundproofed by special sound-absorbing material. ADDITIONAL ACCESSORIES Coils and treatments Cu/Al - Epoxy painting Opt. Cu/Al - Epoxy painting Opt. - 3000h Resistance to corrosion in salt fog according to ASTM B117. - Resistance to UV rays. Cu/Cu - Tube & fin coil (Opt. 881). Remote Keypad and Cascade Drive Management Kit. Rubber anti-vibration mounts. Hydronic group Configuration without the hydronic group is available. The hydronic group is comprised of the following components: Safety valve, air release valve, antifreeze electric heater, water flow switch, and net type filter (not installed). Remote connectivity Serial card for ModBus protocol. Buffer tank Buffer tank to be installed under the unit and dedicated piping connections: 4BTB 30: 30-liter storage tank (size 004-015). 4BTB 60: 60-liter storage tank (size 020-030). Buffer insulated tanks to be installed in the technical room: 4BT 35: 35-liter storage tank (wall installation); 4BT100: 100-liter tank; 4BT200: 200-liter tank.

COMFORT CHILLERS i-bx Air-cooled liquid chiller for outside installation from 4,3 to 35,1 kw. ASHRAE 90.1 compliant i-bx 004 006 008 010 013 010 Power supply V/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 400/3+N/50 PERFORMANCE COOLING ONLY (GROSS VALUE) Cooling capacity (1) kw 4,3 6,11 8,1 10,6 12,9 10,7 Total power input (1) kw 1,55 2,12 2,82 3,64 4,74 3,64 EER (1) kw/kw 2,77 2,88 2,87 2,91 2,72 2,94 ESEER (1) kw/kw 4,2 4,36 4,7 4,29 4,55 4,36 COOLING ONLY (EN14511 VALUE) Cooling capacity (1)(2) kw 4,3 6,11 8,11 10,6 12,9 10,7 EER (1)(2) kw/kw 2,82 2,92 2,92 2,92 2,74 2,95 ESEER (1)(2) kw/kw 4,53 4,6 5,08 4,34 4,69 4,42 Cooling energy class C B B B C B ENERGY EFFICIENCY SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281) Ambient refrigeration Prated,c (7) kw 4,3 6,11 8,11 10,6 12,9 10,7 SEER (7)(8) 4,38 4,43 4,93 4,39 4,78 4,46 Performance ηs (7)(9) % 172 174 194 172 188 176 EXCHANGERS HEAT EXCHANGER USER SIDE IN REFRIGERATION Water flow l/s 0,21 0,29 0,39 0,51 0,62 0,51 Available unit s head (1) kpa 50,7 38,1 61,8 55,6 55,3 52,7 REFRIGERANT CIRCUIT Compressors nr. N 1 1 1 1 1 1 No. Circuits N 1 1 1 1 1 1 Refrigerant charge kg 1,45 2,1 3,55 3,6 3,65 3,6 NOISE LEVEL Sound Pressure (3) db(a) 33 34 35 38 39 38 Sound power level in cooling (4)(5) db(a) 64 65 66 69 70 69 SIZE AND WEIGHT A (6) mm 900 900 900 900 900 900 B (6) mm 370 370 420 420 420 420 H (6) mm 940 940 1240 1240 1240 1240 Operating weight (6) kg 75 80 95 110 125 110 Note 1 Plant (side) cooling exchanger water (in/out) 12 C/7 C; Source (side) heat exchanger air (in) 35 C. 2 Values in compliance with EN14511-3:2013. 3 Average sound pressure level at 10m distance, unit in a free field on a reflective surface; non-binding value calculated from the sound power level. 4 Sound power on the basis of measurements made in compliance with ISO 9614. 5 Sound power level in cooling, outdoors. 6 Unit in standard configuration/execution, without optional accessories. 7 Seasonal energy efficiency of the cooling environment [REGULATION (EU) N. 2016/2281] 8 Seasonal space heating energy index 9 Seasonal energy efficiency of the space cooling The units highlighted in this publication contain HFC R410A [GWP100 2088] fluorinated greenhouse gases. Certified data in EUROVENT HYDRONIC TERMINALS a-life HP a-cnd a-chd i-cnd i-chd 06/07

06/07 R HFC R-410A INV. DRIVEN COMP. SCROLL COOLING ROTATIVE AXIAL PLATES i-bx 013 015 020 025 030 035 Power supply V/ph/Hz 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 PERFORMANCE COOLING ONLY (GROSS VALUE) Cooling capacity (1) kw 13,3 15,5 20,6 25 29,8 35,1 Total power input (1) kw 4,74 5,44 7,2 8,69 10 11,8 EER (1) kw/kw 2,81 2,85 2,86 2,88 2,98 2,97 ESEER (1) kw/kw 4,57 4,14 4,12 4,26 4,15 4,29 COOLING ONLY (EN14511 VALUE) Cooling capacity (1)(2) kw 13,3 15,5 20,6 25 29,9 35,2 EER (1)(2) kw/kw 2,82 2,87 2,88 2,9 3,01 3 ESEER (1)(2) kw/kw 4,69 4,2 4,2 4,36 4,27 4,39 Cooling energy class C C C B B B ENERGY EFFICIENCY SEASONAL EFFICIENCY IN COOLING (Reg. EU 2016/2281) Ambient refrigeration Prated,c (7) kw 13,3 15,5 20,6 25 29,9 35,2 SEER (7)(8) 4,8 4,31 4,31 4,52 4,52 4,57 Performance ηs (7)(9) % 189 169 169 178 178 180 EXCHANGERS HEAT EXCHANGER USER SIDE IN REFRIGERATION Water flow l/s 0,64 0,74 0,99 1,2 1,43 1,68 Available unit s head (1) kpa 51,7 76,7 66,3 60,3 90 73,5 REFRIGERANT CIRCUIT Compressors nr. N 1 1 1 1 1 1 No. Circuits N 1 1 1 1 1 1 Refrigerant charge kg 3,65 4,7 6,8 7 7,9 8,4 NOISE LEVEL Sound Pressure (3) db(a) 39 43 43 43 44 45 Sound power level in cooling (4)(5) db(a) 70 74 74 75 76 77 SIZE AND WEIGHT A (6) mm 900 900 1450 1450 1450 1700 B (6) mm 420 420 550 550 550 650 H (6) mm 1240 1390 1200 1700 1700 1700 Operating weight (6) kg 125 135 190 250 270 305 The i-bx range is compatible with all Climaveneta branded hydronic terminals. MHD a-life i-life i-life2 Slim

Head Office: Via Caduti di Cefalonia 1-36061 Bassano del Grappa (VI) - Italy Tel (+39) 0424 509 500 - Fax (+39) 0424 509 509 i-bx_eng_04-2018