EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS)

Similar documents
DOCUMENT TABLE OF CONTENTS

NZS 4510:2008 Incorporating Amendment No. 1. New Zealand Standard. Fire hydrant systems for buildings. Superseding NZS 4510:1998 NZS 4510:2008

EEMUA E Learning and Publications Catalogue

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

Technical Specification

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

Proposed standards for Chinese national adoption

Fire Pump Specification

ESSAY: This will be a written paper of 6 essay questions. Candidates are to answer 5 questions in 2 hours for 60 marks.

PARKERSTEEL Vauxhall Road, Canterbury, Kent CT1 1HD

AS/NZS :2009 Explosive atmospheres - Part 14: Electrical installations design, selection and erection

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Elite Safety Consultants. Your One Stop Safety Solution Provider Safety: It s a choice and not a chance. A glimpse at our Profile

Technical Specification

Australian/New Zealand Standard

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

OCCUPATIONAL PROFILE FIRE FIGHTING EQUIPMENT TECHNICIAN (Special Class Electrician, Fire Detection System Designer) CURRICULUM CODE:

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

SCHEDULE. Essential Safety Measures taken from Schedule 9 of the Building Regulations PART 1 BUILDING FIRE INTEGRITY

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Mauritian Standards/Amendments Published in 2013

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

SECTION AIR COILS

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

SECTION DRY-PIPE SPRINKLER SYSTEMS

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

IEC/TC IEC/TC44 IEC/TC44. Amd.1DC:201. Ed.3CD:2011. Ed.2.1:2008. Amd.1CDV ED.1: 一連番号 Ed.

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT PLUMBING. Test Code: 5924 Version: 01

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications

PLAN REVIEW SUBMITTAL GUIDE

ISO INTERNATIONAL STANDARD

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

SECTION WET-PIPE SPRINKLER SYSTEMS

Explosion Protection Engineering Principles

Test Code: 8117 / Version 1

NZQA registered unit standard version 1 Page 1 of 5

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

ISO INTERNATIONAL STANDARD. Rotary positive displacement pumps Technical requirements

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

PROFILE. industrial services rental trading

Technical Specification

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

P R O D U C T C A T A L O G U E

COBB COUNTY SCHOOLS /S&A % BID DOCUMENTS 2/18/11 SECTION SPRINKLER SYSTEM

Construction Standards Page

EN transition from BS 1387 Structural & Conveyance Business

F4060 RESILIENT SEATED GATE VALVES

Plumbing Technology/Plumber CIP Task Grid

SECTION WET-PIPE SPRINKLER SYSTEMS

A. This Section includes the following domestic water piping specialties:

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

Technical Specification

SECTION DUCTWORK

Technical Specification

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

AS/NZS :2008

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Substation Signage. Document Number: 1-11-FR-12

INTERNATIONAL STANDARD

SECTION DOMESTIC WATER HEATERS

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

AS/NZS :2015. Explosive atmospheres AS/NZS :2015. Part 1: Equipment protection by flameproof enclosures d

UFGS (August 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION COOLING TOWERS

REGISTER OF NEW NATIONAL STANDARDIZATION INITIATIVES NOTIFIED UNDER SUBSECTORS IN THE SCOPE OF CENELEC. April 2015

Building Utilities 1 Plumbing and Sanitary Systems

DESCRIPTION OF COOLING TOWERS SERIES TAT

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

IT Module. User Manual. Document Revision Number 1 07/2013

California Fire Code (CFC) Part III contains requirements. Building and Equipment Design Features PART. Chapters 5 through 19

Australian/New Zealand Standard

Standard Specification for Hardened Steel Washers [Metric] 1

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

IMO. Resolution A.952(23) Adopted on 5 December 2003 (Agenda item 17) GRAPHICAL SYMBOLS FOR SHIPBOARD FIRE CONTROL PLANS

SPRINKLERS TABLE OF CONTENTS

IECEx Certificate of Conformity

Annex of the Certificate (Page 1/7) Scope of Accreditation

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

AS/NZS :2014

SECTION AIR HANDLING UNIT

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

ITU-T L.63. Safety practice for outdoor installations

IBC Committee Responsibility Matrix January 2017

Transcription:

EXPRESSION OF INTEREST (EOI) FOR Fire Fighting System (FFS) KWtE-03-PR-EO-ACC-0 Rev01 11 Version: Date: Prepared by: Approved: 01 7/11/18 VMC AMN Page 1 OF 5

1 Project overview ACCIONA s Engineering, Procuring & Construction (EPC) contract will deliver the first of its kind in Australia, a $700 million project in the Kwinana Industrial Area which will process up to 400,000 tonnes a year of household waste. Using best practice technologies and processes, the facility will export an estimated 36MW of electricity back to the grid enough to power around 50,000 homes. 2 Summary of package Supply, testing, delivery and installation of the Fire Fighting System. 3 Standards applicable to the Project AS 1110.1 (set) 2015 ISO metric hexagon bolts and screws Product grades A and B Part 1: Bolts AS 1111 (set) 2015 ISO metric hexagon bolts and screws AS 1112 (set) 2015 ISO metric hexagon nuts AS 1163 2016 Cold-formed structural steel hollow sections AS 1171 1998 Methods for magnetic particle testing of ferromagnetic products and components AS/NZS 1214 2016 Hot-dip galvanized coatings on threaded fasteners AS 1237.1 (set) 2002 Plain washers for metric bolts, screws and nuts for general purposes General plan AS 1349 1986 Bourdon tube pressure and vacuum gauges AS 1275 1985 Metric screw threads for fasteners AS/NZS 1365 1996 Tolerances for flat-rolled steel products AS 1394 2001 Round steel wire for ropes AS 1397 2011 Continuous hot-dip metallic coated steel sheet and strip Coatings of zinc and zinc alloyed with aluminium and magnesium AS 1432 2004 Copper tubes for plumbing, gas fitting and drainage applications AS 1450 2007 Steel tubes for mechanical purposes AS/NZS 1477 2017 PVC pipes and fittings for pressure applications AS 1559 2018 Hot-dip galvanised steel bolts and associated nuts and washers for tower construction AS/NZS 1567 1997 Copper and copper alloys Wrought rods, bars and sections AS 1569 1998 Copper and copper alloys seamless tubes for heat exchangers AS/NZS 1571 1995 Copper seamless tubes for air-conditioning and refrigeration PAGE 2 OF 5

AS/NZS 1594 2002 Hot-rolled steel flat products AS 1627.1 (set) 2003 Metal finishing preparation and pre-treatment of surfaces AS 1628 1999 Water supply metallic gate, globe and non-return valves AS 1683.1 (set) 2002 Methods of test for elastomers AS 1710 2007 Non-destructive testing of carbon and low alloy steel plate test methods and quality classifications AS 1722.2 1992 Pipe threads of Whitworth form Fastening pipe threads AS 1830 2007 Iron castings - grey cast iron AS 1831 2007 Double cast iron AS 1929 2009 Non-destructive testing glossary of terms AS 2062 1997 Non-destructive testing penetrant testing of products and components AS 2083 2005 Calibration blocks and their method of use in ultrasonic testing AS 2084 1987 Non-destructive testing eddy current testing of metal tubes AS 2177 2006 Non-destructive testing radiography of welded butt joints in metal AS 2207 2007 Non-destructive testing ultrasonic testing of fusion webbed joints in carbon and low alloy steel AS/NZS 2280 2014 Ductile iron pipes and fittings AS 2452.3 2005 Non-destructive testing AS 2528 1982 Bolts, stud bolts and nuts for flanges and other high and low temperature applications AS 2544 1995 Grey iron pressure fittings AS 2554 1998 Hose and hose assemblies for air AS/NZS 2574 2000 Non-destructive testing ultrasonic testing of steel castings and classification of quality AS/NZS 2728 2013 Pre-finished/pre-painted sheet metal products for interior/exterior building applications performance requirements AS 2824 2003 Non-destructive testing ultrasonic methods evaluation and quality classification of metal bearing bonds AS 3566.1 2002 Self-drilling screws for the building and construction industries AS 3791 1991 Hydraulic hose AS/NZS 4130 2009 Polyethylene (PE) pipes for pressure application AS 4131 2010 Polyethylene (PE) compounds for pressure pipes and fittings AS 4291.1 (set) 2015 Mechanical properties of fasteners made of carbon steel and alloy steel AS 4343 2014 Pressure equipment hazard levels AS/NZS 4534 2006 Zinc and zinc/aluminium-alloy coatings on steel wire AS/NZS 4680 2006 Hot-dip galvanised (zinc) coatings on fabricated ferrous articles AS/NZS 4791 2006 Hot-dip galvanized (zinc) coatings on ferrous open section AS/NZS 4792 2006 Hot-dip galvanized (zinc) coatings on ferrous hollow sections, applied by a continuous or a specialised process AS ISO 9712 2014 Non-destructive testing qualification and certification of NDT personnel AS ISO 1000 1998 The International System of Units (SI) and its application AS 1319 1994 Safety signs for the occupational environment AS 1100.101 1992 Technical drawing AS 1101.1 (set) 2007 Graphical symbols for general engineering AS 1269 (set) 2005 Occupational noise management AS/NZS 1336 2014 Eye and face protection guidelines AS 1580 (set) 2002 Paints and related materials AS 1657 2013 Fixed platforms, walkways, stairways and ladders Design, construction and installation PAGE 3 OF 5

AS 1715 2009 Selection, use and maintenance of respiratory protective equipment AS 1716 2012 Respiratory protective devices AS/NZS 2243.2 (set) 2006 Safety in laboratories Chemical aspects AS 2436 2010 Guide to noise and vibration control on construction, demolition and maintenance sites AS 2700 2011 Colour standards for general purposes AS 2812 2005 Welding, brazing and cutting of metals glossary of terms AS 3545 2004 Welding positions AS/NZS 4501.1 2008 Occupational protective clothing Guidelines on the selection, use, care and maintenance of protective clothing AS/NZS ISO 9000 2016 Quality management systems Fundamentals and vocabulary AS/NZS ISO 9001 2016 Quality management systems Requirements AS/NZS ISO 31000 2009 Risk management Principles and guidelines HB 90.3 2000 The Construction Industry Guide to ISO 9001:2000 AS/NZS 1158 2005 Lighting for roads and public spaces AS 1284.4 2006 Electricity meters Alternating current watthour meters classes 0.5 and 2.0 AS 1359.0 1998 Rotating electrical machines General requirements Introduction and list of parts AS/NZS 1768 2007 Lightning protection AS/NZS 2053.1 (set) 2001 Conduits and fittings for electrical installations General requirements AS 2067 2016 Substations and high voltage installations exceeding 1 kv a.c. AS 2374.8 2000 Power transformers Application guide AS 2380.1 1989 Electrical equipment for explosive atmospheres Explosion-protection techniques AS 2380.4 1994 Electrical equipment for explosive atmospheres Explosion-protection techniques Pressurized rooms or pressurized enclosures AS/NZS 3000 2007 Electrical installations (known as the Australian/New Zealand wiring rules) AS/NZS 3008.1.1 2017 Electrical installations Selection of cables Part 1: Cables for alternating voltages up to and including 0.6/1 kv Typical Australian installation conditions AS/NZS 3010 2017 Electrical installations Generating sets AS/NZS 3011.1 1992 Electrical installations Secondary batteries installed in buildings Vented cells AS/NZS 3011.2 1992 Electrical installations Secondary batteries installed in buildings Sealed cells AS/NZS 3012 2010 Electrical installations Construction and demolition sites AS/NZS 3013 2005 Electrical installations Classification of the fire and mechanical performance of wiring system elements AS/NZS 3017 2007 Electrical installations Verification guidelines AS/NZS 3019 2007 Electrical Installations Periodic verification AS/NZS 3084 2017 Telecommunications installations Telecommunications pathways and spaces for commercial buildings AS/NZS 3085.1 2004 Telecommunications installations Administration of communications cabling systems Basic requirements AS/NZS 3760 2010 In-service safety inspection and testing of electrical equipment AS/NZS 3800 2012 Electrical equipment for explosive atmospheres Repair and overhaul AS/NZS 4509.1 2009 Stand-alone power systems Safety and installation AS/NZS 4509.2 2010 Stand-alone power systems System design AS/NZS 4761.1 2008 Competencies for working with electrical equipment for hazardous areas (EEHA) Competency Standards AS/NZS 4761.2 2008 Competencies for working with electrical equipment for hazardous areas (EEHA) Guide to assessing competency AS/NZS 4836 2011 Safe working on or near low-voltage electrical installations and equipment PAGE 4 OF 5

AS/NZS 4853 2012 Electrical hazards on metallic pipelines AS/NZS 5000.1 (set) 2005 Electric cables Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kv AS 60044.1 (set) 2007 Instrument transformers Current transformers (IEC 600441 Ed.1.2 (2003) MOD) AS/NZS 60076.1 (set) 2014 Power transformers AS/NZS 60079 (set) 2017 Explosive atmospheres AS 60529 2004 Degrees of protection provided by enclosures (IP code) AS 60849 2004 Sound systems for emergency purposes AS/NZS 1221 1997 Fire hose reels AS 1603.1 (set) 1997 Automatic fire detection and alarm systems AS 1670.1 (set) 2015 Fire detection, warning, control and intercom systems System design, installation and commissioning Part 1: Fire AS 1682.1 (set) 2015 Fire, smoke and air dampers AS/NZS 1841.1 2007 Portable fire extinguishers General requirements AS 1851 2012 Routine service of fire protection systems and equipment AS 2118.1 (set) 2017 Automatic fire sprinkler systems, Part 1: General systems AS 2304 2011 Water storage tanks for fire protection systems AS 2362 (set) 2002 Fire detection, warning, control and intercom systems AS 2419.1 2017 Fire hydrant installations, Part 1: System design, installation and commissioning AS 2441 2005 Installation of fire hose reels AS 2444 2001 Portable fire extinguishers and fire blankets Selection and location AS 2941 2013 Fixed fire protection installations Pump set systems AS 4072.1 (set) 2005 Components for the protection of openings in fire-resistant separating elements Service penetrations and control joints AS 4428.1 (set) 1998 Fire detection, warning, control and intercom systems Control and indicating equipment AS 7240 (set) 2007 Fire detection and alarm systems PAGE 5 OF 5