TABLE OF CONTENTS EKHTS-A

Similar documents
TABLE OF CONTENTS EKHWS

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA

TABLE OF CONTENTS ERSQ-AAY1

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

High temperature hydrobox for VRV

EEDEN technical data ERHQ AA

INSTALLATION MANUAL. Domestic hot water tank with UK kit for air to water heat pump system EKHTS200AC EKHTS260AC EKHTSU200AC EKHTSU260AC EKUHWHTA

EEDEN technical data EKSOLHWAV1

High temperature heating system AIR TO WATER HEAT PUMPS. Renovation - Heating - Domestic hot water

Heating. Daikin Altherma Flex Type. Catalogue ALL SEASONS PERFECT C MFORT. Centralised 3-in-1 heating solution with the scope for individuality

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

THE HEAT PUMP CHOICE OF PROFESSIONALS

Heating. Catalogue. Climate comfort. All seasons. Heating. Air conditioning. Applied Systems. Refrigeration. Heating - Domestic hot water - Cooling

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB

Daikin Altherma hybrid heat pump. The natural combination

EEDEN technical data EKRTR. Altherma. Altherma

Daikin Altherma Selection Report

EEDEN technical data ERHQ AA. Altherma. Altherma

General Outline: Altherma

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

TABLE OF CONTENTS ERHQ BAV3

Multipoint Technical Data

Operation manual. Daikin Altherma Low temperature split EHBH04CB EHBH08CB EHBH11CB EHBH16CB EHBX04CB EHBX08CB EHBX11CB EHBX16CB

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

White paper: New Ecodesign rules and energy labelling for space and water heaters

The natural ombination

DESIGN & TECHNICAL MANUAL

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

12/11/08. David Pepper- Managing Director Lochinvar Ltd. Steve Addis - Product Manager L.Z.C products

Heating. Why choose a Daikin heating system? 20. Products overview 24. Combination tables 26. Options & accessories 74

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

Heating. Catalogue. Climate comfort. All Seasons. For end users. Heating. Air Conditioning. Applied Systems. Refrigeration

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

technical data air conditioning systems RZQ B8W1B Split Sky Air

Slide 1 Jul 20, 2006 Viessmann UK

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

D O M E S T I C Solar Thermal

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

ZIP AquaFlo II. Models: Direct, Indirect and Solar Compatible. Unvented cylinder water heaters

your comfort. our world. Heating Catalogue Energy-efficient & renewable solutions

Heating. Catalogue. Climate comfort. All seasons. Heating. Air conditioning. Industrial Application. Refrigeration

Heat Pump Presentation. by James O Donoghue

Unvented Direct & Indirect Hot Water Cylinders (400L L)

Heating. Pricelist Heating PERFECT C MFORT. Catalogue. All seasons PERFECT C MFORT. Heating. Air Conditioning. Applied Systems.

Heating. Technical Data EEDEN ERRQ-AY1

Heating 2014 Pricelist

SOLAR HEATING SYSTEMS

Optimus Gas Absorption Heat Pump

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER ANSWER SCHEDULE

Pricelist. Heating. All seasons Perfect c mfort

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

Central Home Heating and Hot Water Supply

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

VRV HT Basic control functions (HXHD* unit)

EEDEN technical data. Altherma TM

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

INSTALLATION INSTRUCTION

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

Unvented Direct & Indirect Hot Water Cylinders (400L L)

technical data air conditioning systems RZQ C7Y1B Split Sky Air

Daikin Altherma Hybrid User Guide

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

Heating Version 1. Pricelist

Technical Data Manual Model Nos. and pricing: see Price List

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

and sanitary hot water Catalogue 2009

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

The sealless FLUX F 424

Operation manual. ROTEX HPU hybrid heat pump module RHYHBH05AA RHYHBH08AA RHYHBX08AA. Operation manual ROTEX HPU hybrid heat pump module.

Split Type System. Air to Water Heat Pump

FREQUENTLY ASKED QUESTIONS

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

DHW Tanks Indirect Tanks for Domestic Hot Water. New! Single coil tanks with electric element

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

EHS. EHS (Mono, LT, 50Hz)

Installation Instructions

Exceeding the Standard

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

Air Conditioning. Technical Data EEDEN AZQS-BV1

INTERCYL. INTERNAL EXPANSION EXCELLENCE

Domestic Hot Water production

Transcription:

TABLE OF CONTENTS EKHTS-A 1 Features........................................................... 408 2 Specifications..................................................... 409 Technical Specifications........................................... 409 3 Capacity tables................................................... 410 Heating capacity tables............................................ 410 4 Dimensional drawing & centre of gravity...................... 411 Dimensional drawing............................................... 411 5 Piping diagram.................................................... 413 Heating Daikin Altherma 407

o t l c i g t n n - si i ek tt i a oa e 1 Features h H A A S m H K EH D High temperature application: up to 80 C without electric heater Stainless steel domestic hot water tank Cost effective alternative to a fossil fuel boiler Low energy bills and low CO2 emissions Easy to install Total solution for year round comfort 1 408 Heating Daikin Altherma

2 Specifications 2-1 Technical Specifications EKHTS200A EKHTS260A Casing Colour Metallic grey Material Galvanised steel (precoated sheet metal) Dimensions Packing Height mm 1,470 1,745 Width mm 680 680 Depth mm 800 800 Unit Height mm 1,335 1,610 Unit Height Integrated on indoor unit mm 2,010 2,285 Dimensions Unit Width mm 600 600 Depth mm 695 695 Weight Machine weight - empty kg 70 78 Gross Weight - empty kg 81 89 Packing Material EPS Carton Weight kg 11 11 Main components Water volume l 200 260 Wood Material Stainless steel (DIN 1.45) Max. temperature C 75 75 Max. water pressure bar 10 10 Insulation Material EPS Heat loss kwh/ 24h 1.2 1.5 Main components Heat Quantity 1 1 3-Way Valve Coefficient of flow (kv) Material Duplex steel LDX 01 Surface m² 1.56 1.56 Internal coil volume l 7.5 7.5 space heating m³/h 13 13 domestic hot water tank m³/h 8 8 Main components 3-Way Valve Inlet inch Male Quick coupling 35 3-Way Valve Outlet space heating mm Female Quick coupling 35 domestic hot water tank mm Female Quick coupling 25 Temperature sensor Cable length m 11.5 11.5 Piping connections Safety Devices Water inlet heat Water outlet heat Water inlet heat Water outlet heat Diameter mm Female Quick coupling 25 Diameter mm Female Quick coupling 25 Diameter inch G 3/4 (female) Diameter inch G 3/4 (female) Cold water in Diameter inch G 3/4 (female) Hot water out Diameter inch G 3/4 (female) Recirculation connection inch G 1/2 (male) Service hole Size Diameter mm Thermal cutout (on indoor unit): 90-95 C 2 Heating Daikin Altherma 409

3 Capacity tables 3-1 Heating capacity tables Altherma HT-TW Domestic hot water tank 3 The DAIKIN ALTHERMA heat pump in combination with the optional domestic hot water tank provide hot water for household usage. The below mentioned date allow a proper selection of the domestic hot water tank size for maximum comfort and efficiency. (1) Capacity: EKHTS*200 EKHTS*260 Total capacity (L) 0 258 Actual capacity (L) 193,5 250,5 Total capacity = internal volume of tank(= effective water volume+ coil volume) Actual capacity=effective water volume inside the tank (2) Maximum volume of usable hot water: The volume of hot water available for domestic usage depends on the physical volume of the tank, on the domestic water setpoint temperature and on the temperature spreading in the tank. Definition: Maximum volume of usable hot water = the volume of hot water available for domestic usage at a temperature of 40 C. 40 C is considered a comfortable domestic hot water temperature. (cold water inlet temp = 10 C) EKHTS*200 EKHTS*260 Setpoint temp. Maximum volume of Tapping pattern* usable hot water Small Medium High very high 40 190 +++ + - - 50 255 +++ ++ - - 60 320 +++ +++ - - 70 385 +++ +++ + - 40 250 +++ ++ - - 50 330 +++ +++ - - 60 415 +++ +++ ++ - 70 500 +++ +++ ++ + Grade +++ more than excessive availability of sanitary hot water (more than 40% of EHWV is still available after tapping pattern) ++ Excessive availability of sanitary hot water. (10%< EHWV still available after tapping pattern<40%) + Sufficient availability of sanitary hot water. (EHWV still available after tapping pattern <10%) - Temporary shortage of sanitary hot water can occur. Tapping pattern** Small Daily demand up to 90l -> typical 1-person daily usage pattern Medium Daily demand up to 190l -> typical 2-persons daily usage pattern High Daily demand up to 370l -> typical 3 to 4 persons daily usage pattern very high Daily demand up to 500l -> 5 to 6 persons daily usage pattern * based upon heat up to tank once / 24 hours ** Heat losses (over 24 hrs) are included in the tapping patterns (3) Standing Heat loss: Heat losses [kwh/24h] EKHTS*200 1.2 EKHTS*260 1.5 * heat loss of tank at_t = 45K (4) Heat-up time: Definition: Heat-up time = The time is required to heat up the domestic hot water tank from 15 C to 60 C (minutes) EKHBRD11 Heat-up time <min> EKHBRD14 EKHBRD16 EKHTS*200 60 50 40 EKHTS*260 70 60 50 conditions for testing: Ta = 7 CDB / 6 CWB, TStart = 15 C (5) Reheat time: Definition: Reheat time = The time required to reheat the deomestic hot water tank back to 60 C after tapping 70% of the actual volume. EKHBRD11 Reheat time <min> EKHBRD14 EKHBRD16 EKHTS*200 50 40 30 EKHTS*260 60 50 40 Starting condition before tapping 70% of volume: tank at 60 C conditions for testing: Ta = 7 CDB / 6 CWB, TCold = 15 C 3TW58802-1A 410 Heating Daikin Altherma

4 Dimensional drawing & centre of gravity 4-1 Dimensional drawing EKHTS(P)200* + EKHBRD* 6 connection from EKHBRD (quick coupling) 7 connection to EKHBRD (quick coupling) 8 connection from EKHBRD (quick coupling) at bottom tank 9 connection to EKHBRD (quick coupling) at bottom tank 11 Service hole inner J125, socket spanner width 32mm (only on EKHTSP * models) 13 Levelling feet (on EKHBRD* unit) 4 EKHTS(P)260* + EKHBRD* 6 connection from EKHBRD (quick coupling) 7 connection to EKHBRD (quick coupling) 8 connection from EKHBRD (quick coupling) at bottom tank 9 connection to EKHBRD (quick coupling) at bottom tank 11 Service hole inner J125, socket spanner width 32mm (only on EKHTSP * models) 13 Levelling feet (on EKHBRD* unit) left installation right installation upwiring (refer to EKHBRD*. 3TW58804-1) Min. 600 Min. 600 (Space required for switch box removal EKHBRD*) (Space required for switch box removal EKHBRD*) Note: Center of gravity Only for EKHTS* Note: Center of gravity Only for EKHTS* 3TW58804-1A Heating Daikin Altherma 411

4 Dimensional drawing & centre of gravity 4-1 Dimensional drawing 4 EKHTS(P)200* max. 10m 6 connection from EKHBRD (quick coupling) 7 connection to EKHBRD (quick coupling) 8 connection from EKHBRD (quick coupling) at bottom tank 9 connection to EKHBRD (quick coupling) at bottom tank 11 Service hole inner J125, socket spanner width 32mm (only on EKHTSP * models) 13 Levelling feet (in option kit EKFMATHA) 14 Flexible pipes (in option kit EKFMATHA) 15 Adaptor quick connection- G 3/4 (in option kit EKFMAHTA) 16 Field piping EKHTS(P)260* max. 10m 6 connection from EKHBRD (quick coupling) 7 connection to EKHBRD (quick coupling) 8 connection from EKHBRD (quick coupling) at bottom tank 9 connection to EKHBRD (quick coupling) at bottom tank 11 Service hole inner J125, socket spanner width 32mm (only on EKHTSP * models) 13 Levelling feet (in option kit EKFMATHA) 14 Flexible pipes (in option kit EKFMATHA) 15 Adaptor quick connection- G 3/4 (in option kit EKFMAHTA) 16 Field piping EKHTS(P)200* EKHTS(P)260* Required service space depending on possible field piping routing Required service space depending on possible field piping routing 3TW58804-2 412 Heating Daikin Altherma

5 Piping diagram EKHTS Field installation (delivered withekhts*) 3-way motorized valve Field installation (delivered with indoor unit) Outdoor Indoor Shut off valve Load Shut off valve Water return Water flow Option domestic hot water tank Water return Water flow Water main OUT Option domestic hot water tank Water main IN Field supply Only for EKHTS* and EKHTSP* ( Not required for EKHTSU* ) 5 Expansion relief valve Pressure reducing valve with integrated non return valve line strainer Tundish T-piece Tundish Expansion vessel *Field installation delivered with EKUHWCA kit Drain valve T-piece R2T M3S Domestic hot water thermistor 3-way motorized valve Recirculation connection 3TW58805-1 Check valve Flare connection Screw connection Flange connection Pinched pipe Spinned pipe Heating Daikin Altherma 413