UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

Similar documents
UVC in the Operating Room.

AMERICAN AIR & WATER, INC.

Solution: Problem: How can the air, and surfaces, be cleaned to lower the risk from the usual suspects? OR PACKAGE

or

Model RS72. Model RSCS280A. Model RSM2680

Model LIND30-EVO. Model. Model LIND24-EVO LIND24-EVO-2PM

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

GERMICIDAL ULTRAVIOLET FIXTURES

Model 2-OZ, 3-OZ. Model 6-OZ. free standing, wall, or ceiling mount

Problem: How can the air, and surfaces, be cleaned to lower the risk from the usual suspects?

ULTRAVIOLET INDIRECT AIR DISINFECTION

ULTRAVIOLET PORTABLE AREA SANITIZER

February Guide to using germicidal UV. Part of the the Search, Treat, Prevent Comprehensive Approach for TB

The Role of Air Handling Units in Combating the Spread of Infectious Disease

Ultraviolet Air Disinfection Equipment

Purifying air at the. Light. speed of. Carrier Corporation 2007 is a member of the United Technologies Corporation family, stock symbol UTX.

RS4 Whole House IAQ System

STANDARD SINGLE UV GERMICIDAL CLEANING DELUXE DUAL UV GERMICIDAL CLEANING PREMIUM DUAL UV GERMICIDAL CLEANING

GERMICIDAL ULTRAVIOLET IRRADIATORS

Fan System for Drop Ceilings

Mechanical Systems Thesis Proposal: Calvert Memorial Hospital Prince Frederick, MD Holly Mawritz

Model D24-1S. Model D24-2S

14 NANO INDUCT. Product Sheet By Air Oasis. Air Oasis, LLP 3401 Airway Blvd Amarillo Tx 79118

HEALTHY HOME AIR PURIFICATION SYSTEM

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

ULTRAVIOLET SANITARY CONDIT IONERS

Liquid Storage Tank Conditioners

PCR UV Cabinets. PCR UV cabinet workstation UVT-S-AR PCR UV workstation

Introducing the most technically advanced indoor air treatment system

UVC EMITTERS. For microbial control, enhanced IAQ and energy savings. General Products Catalog

NEW GREEN SERIES INSTALLATION AND OPERATION SP-150GS SP-200GS. Manufactured by ULTRA-SUN TECHNOLOGIES, INC Stellar Court Corona, CA 92883

Tru-D Rapid Room Disinfection

Cleans and sanitizes CPAP mask and accessories. Lumin USER MANUAL.

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

UVGI in Ventilation Ducts & Re-circulating Room Air Disinfection Units

Owners Manual Model: XXL

healthy comfort Indoor Air Quality Solutions

AIR PURIFICATION SYSTEM

MULTI-TECH II INSTRUCTION MANUAL. Model XJ-3000D

PCR UV cabinets DNA/RNA

ULTRA-VIOLET STERILIZATION

Document No C Revised January Atlantic Ultraviolet Corporation

Document No A1 Revised September Atlantic Ultraviolet Corporation

AMERICAN ULTRAVIOLET COMPANY. Increase Efficiency Prolong Equipment Improve Air Quality

WHYNTER Eco Pure Air Purifier

Series 650 Read ALL INSTRUCTIONS carefully.

Document No A3 Revised February Atlantic Ultraviolet Corporation

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

(12) Patent Application Publication (10) Pub. No.: US 2017/ A1

PCR UV cabinets DNA/RNA

IAQ-1 DESCRIPTION QUALITY ASSURANCE GENERAL CONSTRUCTION Cabinet UVGI Device Ultraviolet Lamps Ballasts

PCO/UV N-Duct Model. Owner s Guide

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

How to comply with CDC Guidelines

Purelight XD UV Light Wand. User s Guide

OWNER S MANUAL. Air Purifiers ROOM AIR PURIFIER. Operating and Servicing Instructions IMPORTANT: READ CAREFULLY BEFORE ASSEMBLY AND USE

OZONE AIR TREATMENT SYSTEMS

ULTRAVIOLET AIR & OBJECT PURIFICATION SYSTEMS

Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers

ULTRAMAX GOLD UMX REMOTE LAMP AIR DISINFECTION SYSTEMS w/ ODOR REDUCING TECHNOLOGY (PCO) OWNERS GUIDE

Healthy Climate Indoor Air Quality Solutions. Solutions that fit your unique needs

ACCELERATE YOUR CURING TIME

150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D

ALL-AMERICAN PORTABLE OTERILIZERO. Your ally agaenst enfecteon sence Lions Dental Supply To Order Call

UVC/T-M-AR stainless steel UV cabinet

UVT-B-AR. DNA/RNA UV-cleaner box. Operating Manual Certificate. Medical Biological Research & Technologies

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

Installation and Operating Instructions. Rev. 3/24/17. Continuous Antimicrobial Air Cleaner

Innovation in air purification unmatched air quality

Healthy, clean air for your home

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

healthy comfort Indoor Air Quality Solutions

Room Air Purifier Class II Medical Device

SURGICAL LIGHTS. Gleamer Exam Lights EQUIPMENT SURGICAL

CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL

Supplement 3: Engineering Controls

A measured step forward

Document No B Revised June Atlantic Ultraviolet Corporation

Owner s Manual. Installation, Operation & Maintenance. Models B B B3 RoHS

Feedback from potential users of UV in HVAC

WEDECO Quadron UV System

HEPA Air Purifier with Ion Flow Technology

CLEAN AIR SYSTEM.

WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

WARNING WARNING WARNING WARNING WARNING HEALTHY CLIMATE GERMICIDAL LIGHT AIR CLEANERS/ FILTERS

HEALTHY CLIMATE PureAir Air Purification System

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

ultraviolet.com Effective Virtually all microorganisms are susceptible to MIGHTY PURE TM ultraviolet disinfection.

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

NO4G, NO4GS, NO6G, NO6GS

150W Explosion Proof LED Light - 5' Tall Base Stand Mount - 24" Stand - Class I Div 1 C&D V

Model AD30-2. Document No B3 Revised November Atlantic Ultraviolet Corporation

Model CWA200 Owner s Manual

AirPurification System

Clean Air Optima HEPA UV ionizer air purifier CA-508

TEMPLATE Standard Operational Guideline RX Air 3000 Air Purifier

Document No A9 Revised August Atlantic Ultraviolet Corporation

Transcription:

Germicidal UV Technology to Inhibit Microbial Growth and Limit Transfer of Infections in Hospitals UVC can be utilized to inhibit microbial growth and transfer in hospitals through installation in HVAC systems and stand-alone fixtures as follows: Cooling Coil disinfection (a) : Installation of UVC fixtures for direct irradiation of the cooling coils Air disinfection in duct system (a) : Installation of in-duct UVC air cleaners Air disinfection in-room : In-room UVC fixtures can be used for upper air disinfection Surface Sterilization: With direct UVC fixtures UVC for Operating Rooms: A unique combination of air and surface sterilization systems specifically designed for Operating Rooms. Sterilization of occupied and unoccupied rooms: Portable UV sterilizers to use in unoccupied rooms and portable sterilizers for occupied rooms. (a): See our information bulletin UVC Applications in HVAC systems. Air disinfection & surface sterilization in Operating Room OR (Operating Room) UVC sterilization is a specifically developed sterilization solution. Ensuring a sterile environment is very important for preventing complications during organ transplantation or open joint surgical procedures. Achieving and maintaining a sterile environment in operating rooms is crucial for patients with weak immune systems due to cancer or AIDS. Operating room UVC sterilization package compiles all implementations of the germicidal UV technology to ensure the required clean environment. Operating Room UVC sterilization is achieved with two distinctive, although overlapping processes. First, before the operating room is occupied by people, it is entirely irradiated with direct UVC fixtures that sterilize all surfaces exposed to the UV rays. These fixtures must be turned off or turned down before personnel or patients enter the operating room. Second, the air of the operating room is irradiated with indirect germicidal fixtures to ensure sterile environment and stop the transfer of pathogenic or toxic microorganisms through air. The indirect fixtures stay on all the time. They either enclose the UV lamps or are equipped with louvers that direct the UV light to areas above eye level. Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae Bulletin AME-UV010810 Page 1 of 7

UVGI OPERATING ROOM EQUIPMENT PACKAGE FOR REDUCING SURGICAL SITE INFECTIONS (See layout next page) Reduced infection rates mean: Fewer post-operation complications Fewer deaths & less insurance cost. Fewer repeated procedures Direct SM Fixtures (ceiling mounted) Surface Mounted SM units. There are a total of eight (8) of these fixtures. Four (4) are positioned around the O.R. table, one on either side, and one at each end. The remaining four (4) are positioned equidistant from each other around the perimeter of the room. Indirect Wall Mounted Upper Air UVGI Fixtures Wall mounted 7.5-8 above Floor. Typically installed on opposite walls to cover room area appropriately. Fixtures operate all full power at all times, even during procedures. Door Barrier UV Fixtures Mounted over all access doors to operating suite to provide a protective curtain of UV energy. Fixtures operate at full power during procedures. Microorganisms are blocked from entering or exiting the operating theater when doors are opened. Variable Transformer (dimmer) UVC Radiometer Safety during operation Wired to Direct, Surface-Mounted SM IL-1400 Meter & Sensor: This UVC safety goggles and UV fixtures. Acts as a dimmer to dial down lamp intensity to desired level (23 μw/cm²) at the surgical site. Adjustability allows maximum lamp life use. device measures the intensity of UV light on the O.R. table. The sensor is placed on the O.R. table. The measurement of UV intensity is expressed in μw/cm². absorbing cream are provided with package to ensure safety of all personnel in OR. Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae Bulletin AME-UV010810 Page 2 of 7

Complete UV Package for Operating Room A sample layout of the direct SM-36-200 UV fixtures shown below. The TB-36-W systems are wall mounted and stay at full power at all times during procedure for upper air disinfection. The DB-36 system is installed above the door to create a UV curtain for air disinfection. The DB systems also stay at full power during operation procedures. More than one DB UV fixtures may be required depending on the width of the door. The SM-36-200, are direct germicidal UV systems installed in various patterns on the ceiling above the operating table. The UV intensity of these fixtures is controlled by a variable transformer to avoid over-exposure during surgery. Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae Bulletin AME-UV010810 Page 3 of 7

UVGI HOSPITAL MOBILE & PORTABLE PRODUCTS MRS MOBILE ROOM STERILIZERS (UNOCCUPIED ROOM) Model MRS3684P/220 These mobile 8-lamp UV sterilizers feature 2-minute "ON" delay and 24-hour timer for total room irradiation. They are designed for operating rooms, sterile areas, laboratories, unoccupied patient rooms, clean rooms and all other applications where permanent fixtures are not practical. Each unit is equipped with casters for maximum portability. Effective area: 30' x 40' 20 minutes UV lamps: 8 Nos. GML100 lamps 36 (120μW/cm² @ 1m each lamp) Lamps rated life if used continuously: 12,000 hours Voltage: 220V /1Ph /50 Hz Dimensions - 20 L x 20 W x 48 H RM9U105/50 PORTABLE 1 LAMP AIR CLEANER(OCCUPIED ROOM): Portable one lamp UV air cleaner to cover up to 200 square feet. The UV light is directed so the room can be occupied while the unit is ON. Features: Internal Air Filter High intensity 9W germicidal UV lamp Light weight 8 lbs Compact unit 5½ x 9½ x 7¼ Variable speed fan 10 100 cfm (220 v/1 Ph/50Hz) Lamp effective life: 10,000 hours PORTABLE UN AIR PURIFIER AP600-2 LAMPS (OCCUPIED ROOM): The AP-600/50 portable air purifiers utilize 2 high intensity UV lamps and cover up to 300 square feet. The UV light is enclosed so the room can be occupied. Features: Electrostatic Air Filter Light weight 10 lbs Compact unit 10 x 10 x 10 Variable speed fan 10 100 cfm (220v/1 Ph/50 Hz) Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae Bulletin AME-UV010810 Page 4 of 7

UVGI HOSPITAL- PORTABLE PRODUCTS HANDHELD UV SURFACE STERILIZER The AAW Handheld UV wand is a portable direct germicidal UV system for surface disinfection. It can help control the growth of germs such as viruses, bacteria, mold and mold spores and reduce spreading of infections. AAW Handheld UV wand is a portable system for applications where a permanent UVC installation is not desired or needed. The UV system can help reduce or eliminate microbial contamination in spaces that do not need constant exposure to UVC light. Common environments include laboratories, hospitals and food plants. The High Output UV lamp emits high intensity UV so the system should be positioned in a way to avoid exposing people to direct or reflected UV light. System s features: - On/off switch - Safety glasses - Tool-free lamp change - 14" high output shatterproof lamp - 6 three-prong power cord - Oversized handle - Spectrally polished reflector AAW-TBE-14-1 UV PORTABLE OR WALL MOUNTED UV SYSTEM: The AAW-TBE-14-1 is a totally enclosed air-movement germicidal UV system for in-room control of airborne TB and flu, as well as other airborne viruses, bacteria and mold. AAW-TBE-14-1 is designed to be portable or wall mounted. The system features stainless, steel chassis, pull-chain switch, power cord, a fan and two filters. The High Output UV lamp is completely enclosed so the system can be ON at all times protecting personnel and providing maximum germicidal irradiation. Features and Benefits: Improves Indoor Air Quality (IAQ) by reducing airborne bacteria, viruses, mold and spores Reduces the risk of airborne transmission of cold, flu, TB and other illnesses High output UV lamp. Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae Bulletin AME-UV010810 Page 5 of 7

UVGI HOSPITAL- SURFACE-MOUNT DIRECT SURFACE UV STERILIZERS SM SURFCAE MOUNTED FIXTURES: Designed to be mounted to (or suspended from) ceilings. Surface Mounted fixtures incorporate a spectrally polished aluminum reflector designed for maximum dispersion of UVC energy throughout a room. The unique shape prevents dust and sediment from settling on the reflector surface and, thus improves fixture efficiency. Surface Mount fixtures are 5.625" wide with a depth of 4.125", with the exception of Guard Rail fixtures. Guard Rail fixtures are 4.625" in depth. Available in 18 ½, 27 or 37 length, in single or double lamps. RT RECESSED TROFFERS UV OR UV + LIGHTING: These germicidal ultraviolet fixtures are constructed of die-formed, one-piece steel and highly reflective aluminum. They are manufactured to meet hospital, pharmaceutical, clean room and laboratory ultraviolet requirements. Two models are available, with two lamps (RT-36-2G) or four germicidal lamps (RT-36-4G). Also available in 2 germicidal lamps + 2 fluorescent illumination lamps combination (RT-2G2C). Ceiling height up to 9.5': One RT-36-2G per 75sq. ft. or one RT-36-4G per 125sq. ft. fixtures required. Ceiling height 9.5' to 11': One RT-36-2G per 50sq. ft. or one RT-36-4G per 100sq. ft. fixtures required. Ceiling height 11' to 14': One RT-36-2G per 40sq. ft. or one RT-36-4G per 70sq. ft. fixtures required. CE Closed End Germicidal UV Surface Sterilizers In various models with UV lamp configurations of one to four, the CE UV surface sterilizers direct and confine the ultraviolet light to disinfect specific areas. The Closed End reflector UV surface sterilizers are designed for use over conveyor lines, laboratory benches and ventilation hoods or with adjustable legs for UV product sterilization. UV lamp lengths of 4, 6, 8, 12, 18, 27 & 36 inches are available with germicidal ultraviolet (UVC) and/or backlight ultraviolet. Lengths 18, 27 and 37 with up to 4 lamps. SM-36 and SM-36-2 have electronic ballast which can automatically handle 110/220/277V / 50/60Hz. For all other models, voltage must be specified when ordering. All ballasts are UL Listed. Dimensions: 4 L x 2 W x 4¼ D) Dimensions: 18" L x 7-1/4" W x 7-1/2" D) 27" L x 7-1/4" W x 7-1/2" D 37" L x 7¼" W x 7½" D Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae Bulletin AME-UV010810 Page 6 of 7

UVGI HOSPITAL- UPPER ROOM AIR UV STERILIZERS WALL MOUNT TB-W PASSIVE MODELS: Models TB-W are designed to be wall-mounted to reduce upper air contamination. TB-W fixtures feature adjustable louvers to allow unlimited direction of the ultraviolet rays while protecting personnel and providing maximum germicidal irradiation. The units are constructed of high grade stainless steel with an alzak aluminum reflector. They mount 7 feet above the floor and use SBL lamps. TB- W fixtures include a grounded power cord, pull-chain switch, ultraviolet lamp and louver. The TB in-room fixtures control tuberculosis, as well as other airborne pathogens and mold. FAN POWERED ROOM AIR STERLIZER RAM36-2: The RAM36-2 is a totally enclosed air-movement UV system. This fixture comes complete with filters, fans and 2 ultraviolet lamps. It is designed for rooms where congestion or ceiling height prohibits the use of wall-mounted indirect fixtures. Constructed of high grade stainless steel, each fixture produces four or more air changes per hour in rooms up to 200 square feet. CORNER MOUNT CM15 UV AIR CLEANER: Designed to mount in room corners with two keyhole slots at a height of seven feet (7 ), these attractive indirect UV air cleaners incorporate one high intensity UV lamp and cover up to 75 square feet. The Corner Mount UV air cleaner s optional equipment includes an eight-foot power cord and an on/off switch. The high intensity UV lamp is installed with reflectors for equal distribution of the germicidal UV irradiation. The louver restricts and concentrates the ultraviolet rays above eye level so personnel can occupy the room while the air cleaners are operating. DOOR BARRIERS GERMICIDAL FIXTURES: DB-36 UV air cleaner is fabricated of heavy gauge electro-welded steel with white enamel finishing. By creating a curtain of germicidal ultraviolet rays, this UV air cleaner provides effective control of airborne microorganisms between areas. It confines the germicidal UV radiation to a narrow beam, providing full coverage of a threefoot doorway. Larger openings require multiple UV air cleaners. The TB in-room fixtures control tuberculosis, as well as other airborne pathogens and mold. TB-12-W/50, 18 ½ L for 75 M2 area TB-24-W/50, 27 ¾ L for 200 M2 area TB-36-W/50, 37 ½ L for 300 M2 area RAM36-2, 47 ¼ L, 100 CFM airflow, covers 200 Ft2 area Dimensions: 37"L x 7"H x 4"D UV Lamp positioned behind louvers Tel: 971 4 2629700, Fax: 971 4 2629367, E-mail: itete@eim.ae Bulletin AME-UV010810 Page 7 of 7