nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

Similar documents
coldpack water cooled chillers / heat pumps and motoevaporating units C_GNR_0508

COLDPACK_. water cooled chillers / heat pumps and condenserless chillers

GLIDER_. air cooled liquid chilled chillers / heat pumps

nemo a hp rcgroupairconditioning R410A

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

turb new unico turbo frigo turbo fl Liquid chiller equipped with magnetic levitation twostage centrifugal compressors RCGROUP SpA C_GNR_0711

IDROCOMPL _. liquid chillers, condenserless chillers, heat pump with Idrocompl system

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

next NEXT EVO CW kw UP FLOW DOWN FLOW CHILLED WATER E C CLOSE CONTROL AIR CONDITIONERS FOR CHILLED WATER FEEDING,

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

kw COOLING kw HEATING

Water chillers water/water type SIGMA Technical information manual

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR CONDITIONERS. RCGROUP SpA fiftycoolyears C_GNR_0113

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

WZH Ground source heat pumps

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

44,9 202,0 kw. technicalcatalogue

kw. technicalcatalogue

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LZA High efficiency air to water heat pumps with HP compressor

2013 Product Range Precision Air Conditioners (CRAC)

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

Conditioning your ambient, maximising your comfort.

Process glycol chillers

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Heat pump systems and Chillers

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

next DX.U.S* 052.Z2.H6.DC

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

GLIDER EVO GLIDER EVO. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

Kelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

unico turbo fl kw R134a MICRO CHANNEL OIL FREE INVERTER FLOODED CLASS E C Energy Class RCGROUP SpA fiftycoolyears C_GNR_0113

Air Cooled Chillers & Heat Pumps WinPACK HE-A

ef cooling - FURRER Industriekühlung GmbH Technical Data Water Cooling Units EPI-A 2 - EPI-A 6 norden cooling

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

21,8 222 kw COOLING 25,2 236 kw HEATING

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

unico pf unico pf rcgroupairconditioning

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

CRIMSON & CRIMSON MAX

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

PRODUCT GUIDE

CHAPTER 6 CONDENSING UNITS

Air cooled industrial chillers

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

kw. technicalcatalogue

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

PYXIS U PYXIS U. rcgroupairconditioning

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

pyxis u pyxis ua NEW rcgroupairconditioning

Galletti Water chillers and heat pumps catalogue

NEXT DL NEXT DL. rcgroupairconditioning

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

Blue Box Epsilon Echos +

Technical data LA 9S-TU

H4T R410A. refrigerant

RC GROUP. MULTIPLO.A.STD/ELN G Multifunctions air cooled liquid chillers with Scroll compressors and axial fans R407C. SCROLL compressors kw

Package Hygienic Air Handling Units. PHK Series

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

EQUH PF PACKAGED HEAT PUMP AIR/ WATER LIQUID CHILLER FOR INDOOR INSTALLATION

DIN EN , DIN EN , DIN EN , DIN EN

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

S-Therm Air to Water Heat Pumps

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

Transcription:

171 water cooled chillers / heat pumps and motoevaporating units COOLING HEATING R410A 1 96 3 2 0 1 3 f i f t y c o o l y e a r s RCGROUP SpA 19632013 fiftycoolyears PLATE 5,4 30,5 kw 6,4 37,4 kw

172 VERSIONS : (R410A) Cooling capacity 5,7 30,5 kw Liquid chiller equipped with scroll compressor and built-in water cooled condenser. HP (R410A) Cooling capacity 5,6 30,0 kw Heating capacity 7,6 37,4 kw Heat pump liquid chiller equipped with scroll compressor and built-in water cooled condenser GENERAL FEATURES liquid chillers offer a simple and cheap solution for domestic and small offices application. The criticality of these smaller systems is the same as the larger installations, differing only in size Comfort requirements for a small 40 m 2 2/4 persons advertising office are just the same but smaller, than for an equivalent 1000 m 2 / 100 persons location. (Water/water heat pump). A (R410A) Cooling capacity 5,4 26,0 kw Motoevaporating unit equipped with scroll compressor for remote air cooled condenser matching. A HP (R410A) Cooling capacity 5,5 25,0 kw Heating capacity 6,4 29,3 kw Heat pump motoevaporating unit equipped with HEAT PUMP - HP 57 C - Maximum outlet water temperature in heating mode. scroll compressor for remote air cooled condenser matching. R410A PLATE Cooling Heating Scroll type compressor R410A refrigerant charge Plate type exchanger Indoor installation 19632013 fiftycoolyears RCGROUP SpA

173 MAIN COMPONENTS Housing in epoxy painted galvanized steel sheet Thermo-acoustic lining inside the unit Scroll compressor Welded plate evaporator Welded plate condenser ( / HP) Cycle reversing valve ( HP / A HP) Defrosting system ( A HP) Microprocessor control Water flow control by pressure switch 3-speed water pump Electrical box in separate compartment Main switch MAIN OPTIONAL ACCESSORIES Condensing control valve ( / HP) Water tank Partial heat reclaim Serial port Remote air cooled condenser ( A / A HP) Designed for comfort applications These liquid chillers grant the same reliability of the other RC Group products, being designed and manufactured with same philosophy as all RC Group products during more than 40 years activity. Thanks to this long experience, the main repetitive fault rates and relative causes have been eliminated through the use of well tested and top quality components. Furthermore, all maintenance operations have been reduced at the minimum, since this type of chillers is now to be considered as a common home appliance, that does not require any frequent and complicated operations. Easy and quick installation, since the units are completely factory assembled, wired and filled with refrigerant and oil and complete with all control and protection devices. They simply need electrical and hydraulic connections. HEAT PUMP - A HP 55 C - Maximum outlet water temperature in heating mode. RCGROUP SpA 19632013 fiftycoolyears

174 TECHNICAL DATA AND NOMINAL PERFORMANCES water cooled Cooling capacity (1) kw 5,7 7,4 11,1 14,1 5,7 7,3 10,4 kw 1,4 1,8 2,4 3,0 1,4 1,8 2,3 kg 88,7 91,4 101,5 106,3 88,7 91,4 101,5 Sound pressure (2) db(a) 42,0 42,0 44,0 44,0 42,0 42,0 44,0 Cooling capacity (1) kw 13,3 15,1 17,4 20,1 24,8 30,5 kw 2,9 3,4 4,0 4,5 5,6 6,3 kg 106,3 114,5 116,0 118,5 141,7 147,4 Sound pressure (2) db(a) 44,0 47,0 51,0 48,0 50,0 50,0 (1) Gross value - Referred to chilled water temperature 12/7 C and condenser water inlet temperature at 30 C (2) Sound pressure 1m far in free field conditions HP reversible heat pump - water/water Cooling capacity (1) kw 5,6 7,6 10,5 13,0 5,3 6,8 9,5 Heating capacity (2) kw 7,6 9,5 13,1 17,2 7,2 9,2 12,7 kw 1,4 1,8 2,3 3,0 1,4 1,8 2,3 Power input (2) kw 1,9 2,3 3,1 3,9 1,9 2,4 3,0 kg 90,8 93,5 103,6 108,4 90,8 93,5 103,6 Sound pressure (3) db(a) 42,0 42,0 44,0 44,0 42,0 42,0 44,0 Cooling capacity (1) kw 12,3 13,9 16,6 18,6 23,4 30,0 Heating capacity (2) kw 16,5 18,5 21,8 24,7 30,8 37,4 kw 2,9 3,5 4,0 4,5 5,6 6,2 Power input (2) kw 3,8 4,3 5,2 5,8 7,1 8,6 kg 108,4 116,6 118,1 120,6 143,8 149,5 Sound pressure (3) db(a) 44,0 47,0 51,0 48,0 50,0 50,0 (1) Gross value - Referred to chilled water temperature 12/7 C and condenser water inlet temperature at 30 C (2) Gross value - Referred to hot water temperature 40/45 C and chilled water inlet temperature at 15 C (3) Sound pressure 1m far in free field conditions according to ISO3744 norms 19632013 fiftycoolyears RCGROUP SpA

175 TECHNICAL DATA AND NOMINAL PERFORMANCES A air cooled motoevaporating unit Cooling capacity (1) kw 5,4 7,1 9,2 12,1 5,4 6,9 9,2 kw 1,6 2,3 3,1 3,8 1,6 2,2 2,9 kg 88,5 90,3 99,5 103,4 88,4 90,3 99,5 Sound pressure (2) db(a) 42,0 42,0 44,0 44,0 42,0 42,0 44,0 TEAM MATE STD M 11 M 11 M 14 M 17 M 11 M 11 M 14 Cooling capacity (1) kw 12,0 13,6 16,2 17,7 21,5 26,0 kw 4,0 4,3 5,0 5,9 7,0 8,4 kg 103,4 110,6 111,7 112,8 134,2 138,0 Sound pressure (2) db(a) 44,0 47,0 51,0 48,0 50,0 50,0 TEAM MATE STD M 17 M 20 M 25 M 25 M 30 M 35 (1) Gross value - Referred to chilled water temperature 12/7 C and outdoor temperature 35 C (2) Sound pressure 1m far in free field conditions according to ISO3744 norms A HP air cooled heat pump motoevaporating unit Cooling capacity (1) kw 5,5 7,3 9,4 12,3 5,2 6,7 8,9 Heating capacity (2) kw 6,4 8,3 10,9 14,1 6,1 7,7 10,3 kw 1,6 2,3 3,1 3,9 1,6 2,2 2,9 Power input (2) kw 1,8 2,4 3,1 3,8 1,8 2,3 3,0 kg 90,6 92,4 101,6 105,5 90,5 92,4 101,6 Sound pressure (3) db(a) 42,0 42,0 44,0 44,0 42,0 42,0 44,0 TEAM MATE HP STD M 11 M 11 M 14 M 17 M 11 M 11 M 14 Cooling capacity (1) kw 11,6 13,1 15,6 17,0 21,5 25,0 Heating capacity (2) kw 13,6 15,0 17,7 19,6 24,9 29,3 kw 3,9 4,3 4,9 5,8 7,0 8,3 Power input (2) kw 3,9 4,4 4,9 5,6 7,0 8,0 kg 105,5 112,7 113,8 114,9 136,3 140,1 Sound pressure (3) db(a) 44,0 47,0 51,0 48,0 50,0 50,0 TEAM MATE HP STD M 17 M 20 M 25 M 25 M 30 M 35 (1) Gross value - Referred to chilled water temperature 12/7 C and and outdoor temperature 35 C (2) Gross value - Referred to hot water inlet temperature 40/45 C and outdoor temperature 7 C (3) Sound pressure 1m far in free field conditions according to ISO3744 norms RCGROUP SpA 19632013 fiftycoolyears

176 dimensions (mm) 900 555 650 air cooled condenser The A / A HP series is planned for the matching to the TEAM MATE condenser series. 19632013 fiftycoolyears RCGROUP SpA