Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS

Similar documents
SECTION AIR DUCT ACCESSORIES

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

Fire, Smoke, and Combination Fire Smoke Dampers

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SMOKE DAMPERS AIRFOIL STAINLESS STEEL

INSTALLATION INSTRUCTION BOOKLET FOR SMOKE DAMPERS

WHEN IT COMES TO FIRE / SMOKE DAMPERS, NAILOR S 1220 SERIES THE WALL PROVIDES THE ULTIMATE CLOSURE!

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

SMOKE DAMPERS SMOKE DAMPERS

COMBINATION FIRE/SMOKE DAMPERS

SECTION Overhead Coiling Doors

Life Safety Dampers Selection and Application Manual

WHEN IT COMES TO FIRE / SMOKE DAMPERS, NAILOR S 1220 SERIES THE WALL PROVIDES THE ULTIMATE CLOSURE!

COMBINATION FIRE/SMOKE DAMPERS

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

COMBINATION FIRE/SMOKE DAMPERS

COMBINATION FIRE/SMOKE DAMPERS

15900 HVAC INSTRUMENTATION AND CONTROLS

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

Fire, Smoke and Control Dampers

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Replacement of pneumatic actuators on Ruskin negator spring dampers with Belimo FSxx Series

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Chilled Water DOAS Fan Powered Terminal Units

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

City of Duluth Festival Center 04/25

SECTION (15767) - UNIT HEATERS

ARCHITECTURAL SPECIFICATIONS

AIR DUCT ACCESSORIES

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

DACC Health Sciences Building Air Handler Assessment/Study

SINGLE DUCT TERMINAL UNITS

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

HIGH-RISE RETROFIT ORDINANCES - NO and NO

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

SECTION OVERHEAD COILING FIRE DOORS

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

Duct Smoke Detector - D4120

SECTION FAN COIL UNITS

SECTION (15820) - AIR DUCT ACCESSORIES

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

FCC Fan-Coil Units High-Performance, Vertical

DUCT SMOKE DETECTOR D4120

Linear Floor Heaters

Contents INDEX. TDM Series Indirect Fired Heaters

SECTION (15900) - INSTRUMENTATION AND CONTROL FOR HVAC

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Architectural Specification Sheet

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

Modular Supply Make-Up Air Unit

SECTION DUCTWORK

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

UNIVERSITY OF ALASKA FAIRBANKS DIVISION 25- INTEGRATED AUTOMATION DESIGN STANDARDS SECTION INTEGRATED CONTROL OF FACILITY LAB FUME HOODS

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

TOTALPAC2 Integrated Fire Protection System

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

Modular Heating & Ventilating Unit Model IGX-HV

Direct Fired Heater Model AD Specification

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

SECTION AIR COILS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

INSTRUCTION SHEET - Replacement of Ruskin Phillips P150 to Belimo FSNF or FSAF Actuator

WARNING! Before replacing actuator, damper must be inspected and determined to be fully functional.

SECTION AIR OUTLETS AND INLETS

WARNING! Before replacing actuator, damper must be inspected and determined to be fully functional. See NFPA 80 & NFPA 105 below for recommendations.

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DESIGN & CONSTRUCTION GUIDELINES

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

SECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE

Installation Instructions

A. Section Masonry Assemblies: Anchor placement in masonry.

Transcription:

Louvers & Dampers April 2008 P.O. Box 606 7435 Industrial Road Florence, Kentucky, 41042 Phone: (859) 647-2299 Fax: (859) 647-7810 Web Site: www.louvers-dampers.com Product Guide Specification SECTION 15820 COMBINATION FIRE SMOKE DAMPERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Combination fire smoke dampers with blades using triple reinforcement grooves meeting the requirements of the latest edition of UL Standard 555 and UL Standard 555S. 1.2 RELATED SECTIONS A. Section 15810 - Ducts. 1.3 REFERENCES A. AMCA 500 - Test Methods for Louvers, Dampers and Shutters. B. AMCA 511 - Certified Ratings Program for Air Control Devices. C. BOCA Building Officials and Code Administrators. D. ICBO International Conference of Building Officials. E. SBCCI Southern Building Code Congress International. F. IBC International Building Code. G. CSFM - California State Fire Marshall Listing for Fire Damper and Smoke Damper. H. NFPA 90A - Installation of Air Conditioning and Ventilating Systems. I. NFPA 92A - Smoke-Control Systems. J. NFPA 92B Smoke Control Systems in Atria, Covered Malls, and Large Areas. K. NFPA 101 Life Safety Code. MR Series 15820-1

L. UL 555 - Standard for Safety; Fire Dampers. M. UL 555S - Standard for Safety; Leakage Rated Dampers for Use in Smoke Control Systems. 1.4 SUBMITTALS A. Product Data: Submit manufacturer's product data. 1. Include UL ratings, leakage, pressure drop, and maximum pressure data. 2. Indicate materials, construction, dimensions, and installation details. 3. Verify conformance to NFPA, UL, CSFM, and applicable building code. 4. Include damper pressure drop data based on tests and procedures performed in accordance with AMCA 500. 1.5 QUALITY ASSURANCE A. Dampers shall be warranted against manufacturing defects for a period of 5 years. B. Dampers shall be tested, rated and labeled in accordance with the latest UL requirements. C. Damper pressure drop ratings shall be based on tests and procedures performed in accordance with AMCA 500 and certified by AMCA (if applicable). 1.6 DELIVERY, STORAGE, AND HANDLING A. Delivery: Deliver materials to site in manufacturer's original, unopened containers and packaging, with labels clearly indicating manufacturer and material. B. Storage: Store materials in a dry area indoor, protected from damage and in accordance with manufacturer's instructions. C. Handling: Handle and lift dampers in accordance with manufacturer's instructions. Protect materials and finishes during handling and installation to prevent damage. PART 2 PRODUCTS 2.1 MANUFACTURER A. Louvers & Dampers, P.O. Box 606, 7435 Industrial Road, Florence, Kentucky, 41042. Phone (859) 647-2299, Fax (859) 647-7810, Web Site www.louvers-dampers.com 2.2 COMBINATION FIRE SMOKE DAMPERS A. Model: MR series combination fire smoke dampers. B. Ratings: 1. Fire Resistance: 1-1/2 hours in accordance with UL555. 2. Smoke Rating: MR Series 15820-2

MR - Leakage Class II Smoke Damper in accordance with UL555S. A Class II smoke 3 damper leaks no more than 20 cubic feet per minute (.57 m /min) at 4 in. wg. (1 kpa) differential pressure. MR - Leakage Class I Smoke Damper in accordance with UL555S. A Class I smoke 3 damper leaks no more than 8 cubic feet per minute (.23 m /min) at 4 in. wg. (1 kpa.) differential pressure. 3. Elevated Temperature Rating: 250 F (121 C) in accordance with UL555S. 350 F (177 C) in accordance with UL555S. 4. Air Flow Rating: 2000 fpm (10.2 m/s) in accordance with UL555S. 5. Differential Pressure Rating: 4 in. wg. in accordance with UL555S. 6. Pressure Drop: Pressure drop for a 12 x 12 (305 mm x 305 mm) unit at a face velocity of 2000 fpm (10.2 m/s) unit shall be no more than 0.164 in. wg. (40.9 Pa). C. Construction: 1. Frame: Sizes 24 W x 24 H (610 mm x 610 mm) and smaller shall be constructed with an integral sleeve/frame design and use a single blade through 12 (304 mm) high for maximum free area. One set of perimeter mounting angles shall be factory attached to stiffen the frame design and to supply a fool-proof, user-friendly construction to reduce field installation labor. 2. Blades: a. Style: Single skin with 3 longitudinal grooves. b. Action: Parallel. c. Material: Minimum 18-GA (1.6 mm) galvanized steel. d. Width: Maximum 11 ½ (152 mm). 3. Bearings: Self-lubricating oil impregnated bronze sleeve type, turning in an extruded hole in the damper frame. 4. Seals: a. Blade: Silicone material to maintain smoke leakage rating to a minimum of 350 F (177 C). b. Jamb: Stainless steel, flexible metal compression type. 5. Linkage: On blade. 6. Axles: Plated steel mechanically attached to the blade. MR Series 15820-3

7. Mounting: Vertical and/or Horizontal. 8. Temperature Release Device: Heat-Actuated, Quick Detect. a. Close (in a controlled manner) and lock damper during test, smoke detection, power failure, or fire conditions through actuator closure spring. At no time shall actuator disengage from damper blades. b. Allow damper to be automatically and remotely reset after test or power failure conditions. After exposure to high temperature or fire, inspect damper before reset to ensure proper operation. c. Gradual closing and locking of damper in 7 to 15 seconds to allow duct pressure to equalize. Instantaneous closure is not acceptable. 9. Release Temperature: 165 degrees F (74 degrees C). 212 degrees F (100 degrees C). 250 degrees F (121 degrees C). 350 degrees F (177 degrees C). 10. Actuator: a. Type: Electric 120 V, 60 Hz, two-position, fail close. Electric 24V, 60 Hz, two-position, fail close. Pneumatic, 20-psi minimum control pressure, two-position, fail close. b. Mounting: External. 5. Finish: Mill galvanized. 2.3 ACCESSORIES A. Sensotherm: 1. UL classified dual temperature device allows the damper to be re-opened after initial closure from high heat. 2. Electrically and mechanically locks damper in closed position when duct temperatures exceed 165 degrees F (74 degrees C) or 212 degrees F (100 degrees C). MR Series 15820-4

3. Allow damper to remain operable through a high limit temperature sensor for smoke management purposes while temperature is below 250 degrees F (121 degrees C) or 350 degrees F (177 degrees C). 4. Replaces single heat actuated temperature release devices on standard dampers. 5. Blade position indicator switches: Two position indicator switches directly keyed to jackshaft in order to allow remote indication of damper blade position. B. Indicator or Auxiliary Switch Package: Switch Package two-position indicator switches linked directly to damper to remotely indicate damper blade position. C. Duct Smoke Detector: 1. Model: SM-501-P. 2151 (requires factory supplied remote test station). 2. Mounting: Factory Mounted, unwired (SM-501-P only). Factory Mounted and wired. Shipped Loose for Field Installation. 3. Type: Photoelectronic. D. Factory Sleeve: 1. 20-GA (1.0 mm) thickness; optional thickness to 16-GA (1.5 mm). 2. Standard sleeve depth is 16 inches (406 mm) long; optional depth to 20 inches (508 mm). 3. Silicone caulk is factory applied to sleeve and damper frame or jamb seal to comply with Class 1 and 2 leakage ratings. E. Mounting Angles: a. 1 ½ x 7/8 x 16-GA (38 mm x 20 mm x 1.5 mm) galvanized steel perimeter tab lock mounting angles; one set factory mounted. 2.4 SOURCE QUALITY CONTROL A. Factory Tests: Factory cycle damper and actuator assembly to assure proper operation. PART 3 EXECUTION MR Series 15820-5

3.1 EXAMINATION A. Inspect areas to receive dampers. Notify the Engineer of conditions that would adversely affect the installation or subsequent utilization of the dampers. Do not proceed with installation until unsatisfactory conditions are corrected. 3.2 INSTALLATION A. Install dampers at locations indicated on the drawings and in accordance with manufacturer's UL approved installation instructions. B. Install dampers square and free from racking with blades running horizontally. C. Do not compress or stretch damper frame into duct or opening. D. Handle damper using sleeve or frame. Do not lift damper using blades, actuator, or jackshaft. END OF SECTION MR Series 15820-6