Inspection Report. 1 Inspection Way Orlando, FL Prepared for: Wanda Figueroa Prepared by: ACF Home Inspections Inc

Similar documents
Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

Home Inspection Report

Home Inspection Report

Home Inspection Report

American Property Inspectors of Northwest Florida, Inc.

Home Inspection Report

Property Condition Report

All Around Home Inspections Ltd 1346 Hurford Ave Courtenay, BC. 123 Sample 6 Plex

Home Inspection Report

The following report was prepared for the buyers of the home and property at 1400 Main St. Anywhere City, Tennessee. The inspection was conducted on

Inspection Report. Prepared for: Tonia Mann. Property Address: 402 Leslie Court McDonough, GA Date: March 07, 2013

Jeff Brown Inspections

Axiom Property Inspections

Canadian Property Inspections

1710 ANYWHERE DRIVE, MONTGOMERY, AL 36109

Attention To Detail Home Inspections, LLC Marchester Dr. Wesley Chapel, FL Report prepared by: Steven Milek Certified NACHI Inspector

1921 River Birch Dr., Shawnee, OK Inspection prepared for: Vicki Jager Date of Inspection: 7/27/2015 Time: 8am Weather: Sunny

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

Watson Home Inspection Services, LLC.

Inside Out Home Inspections

Patriot Home Inspections

FAIRA TRANSPARENCY REPORTS th Ave NE B-3, Kenmore, WA March 28 th, 2017

Troy's Home Inspection Services LLC

Bayshore House Inspections LLC

FAIRA TRANSPARENCY REPORTS. November 21, 2016

Inspection Report 123 My Street Midland, GA

Extra Mile Inspection, Inc.

RW West Consultants. Property Inspection Report NE 199th St, Kenmore, WA Inspection prepared for: FAIRA/ Chris Ellis Real Estate Agent: -

Steve Ramsey Home Inspections

FAIRA TRANSPARENCY REPORTS S 236th St, 10-5, Kent, WA 98032

Inspector FX Field Forms

Hope Home Inspections LLC rd Ln E Sarasota, FL

FAIRA TRANSPARENCY REPORTS SE Woody Creek Ln, Snoqualmie, WA October 12, 2017

SPS Home Inspections, LLC

This Report Was Prepared For: Property Address Inspected:

Inspector Gadget Homes

FAIRA TRANSPARENCY REPORTS. November 21, 2016

Asurity 1. Property Inspection Report S Gurd Rd., Hastings, MI Inspection prepared for: Beretta Lenos Real Estate Agent: Stan Labinski -

Cascade Inspection Services, LLC

Excellent Home Inspection Services, LLC

RW West Consultants. Property Inspection Report

FAIRA TRANSPARENCY REPORTS SE 265th St, Covington, WA October 10, 2017

FAIRA TRANSPARENCY REPORTS Hazel Loop SE, #D, Auburn, WA 98092

Amendment to the Inspection Report

McKinney Inspection Company

Inspection Report. Mr. Happy Homeowner. Property Address: Focal Point Home Inspection Ltd.

Maintence/Renewal Report

PREPARED FOR: (Name of Client) CONCERNING: (Address of Property) BY: P Home. YOUR HOME CHECK 1305 FM 359, Suite G F

All In One Home Inspections

FAIRA TRANSPARENCY REPORTS Spruce Way, Lynnwood, WA August 21, 2017

John Sample. Property Address: 123 Main St. Alpharetta GA Inspector: Jason David. Residential Inspector of America, Inc.

FAIRA TRANSPARENCY REPORTS NE 117th Pl, #F8, Kirkland, WA 98034

FAIRA TRANSPARENCY REPORTS NE 108th St, Redmond, WA April 4 th 2017

FAIRA TRANSPARENCY REPORTS Country Club Dr, B-203, Mill Creek, WA April 5 th, 2017

FAIRA TRANSPARENCY REPORTS Stone Ave N, #205, Seattle, WA 98133

FAIRA TRANSPARENCY REPORTS Brighton Pl, Mukilteo, WA 98275

Hearth and Homes Inspections, llc

Space Coast Home Inspections LLC

FAIRA TRANSPARENCY REPORTS S 248th Pl, Des Moines, WA March 12, 2018

FAIRA TRANSPARENCY REPORTS th Dr NE, Marysville, WA June 14 th, 2017

fieldwork report contains the Functional

FAIRA TRANSPARENCY REPORTS. January 27 th, 2017

FAIRA TRANSPARENCY REPORTS Alaskan Way, 514, Seattle, WA 98101

FAIRA TRANSPARENCY REPORTS. July 6, 2016

Inspection Report. Cheri Maisonneuve. Property Address: 103 Dogleg Dr Moultrie GA. Welcome Home! Premier Home Inspections of Valdosta, LLC

Ph: (907) Quality Homes

FAIRA TRANSPARENCY REPORTS th Ave SE, Renton, WA June 13 th, 2017

FAIRA TRANSPARENCY REPORTS st Pl SE, Sammamish, WA May 18 th, 2017

FAIRA TRANSPARENCY REPORTS Highland Dr, Bellevue, WA 98006

The Salvation Army Southern Territory OFFICERS QUARTERS PROPERTY INSPECTION FORM

FAIRA TRANSPARENCY REPORTS SE 279th St, Maple Valley, WA March 7, 2018

FAIRA TRANSPARENCY REPORTS nd Ave SE, Renton, WA March 21, 2018

FAIRA TRANSPARENCY REPORTS Bothell Everett Hwy, D304, Bothell, WA February 6, 2018

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

FAIRA TRANSPARENCY REPORTS th Ave S, Auburn, WA June 15 th, 2017

Inspection Report. Prepared For: Joe Smith. Property Address: 1234 Slick Lane. #2 Chicago, IL. Inspectrum Inc.

FAIRA TRANSPARENCY REPORTS th Dr NE, Lake Stevens, WA April 4th, 2017

FAIRA TRANSPARENCY REPORTS th St SW, Lynnwood, WA 98037

Property Description: (1) level condominium in a multi-story building Property age/ size: Built 2006, 1,137 s.f. per listing Occupancy Status: Vacant

Peconic Home Inspections, LLC Inspection Report. 123 Lane Suffolk, New York 11900

FAIRA TRANSPARENCY REPORTS th Ave, Seattle, WA April 28 th, 2017


FAIRA TRANSPARENCY REPORTS S 259th St, Des Moines, WA October 2, 2017

Tennessee Valley Property Inspections

FAIRA TRANSPARENCY REPORTS nd Ave S, E-2, SeaTac, WA 98198

FAIRA TRANSPARENCY REPORTS Harbour Pointe Blvd, #301h, Mukilteo, WA 98275

MHI Services Inc. Property Inspection Report

Canadian Property Inspections

FAIRA TRANSPARENCY REPORTS. 405 SW 346th Pl, Federal Way, WA Nov 09th, 2015

Savannah Station Price List

FAIRA TRANSPARENCY REPORTS. 553 Chelan Pl NE, Renton, WA March 3 rd, 2018

Residential * Commercial * Mobile Homes * New Construction

FAIRA TRANSPARENCY REPORTS Waverly Dr, Snohomish, WA May 10 th, 2017

FAIRA TRANSPARENCY REPORTS th St SE, #13A, Auburn, WA January 25, 2018

Homes in Cates Bay - Overview

FAIRA TRANSPARENCY REPORTS th St SE, Lake Stevens, WA June 14 th, 2017

All Waters Edge homes come with the following standard features throughout:

FAIRA TRANSPARENCY REPORTS SE 240th Pl, Maple Valley, WA June 5th, 2017

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

FAIRA TRANSPARENCY REPORTS

Transcription:

Inspection Report 1 Inspection Way Orlando, FL 32825 Prepared for: Wanda Figueroa Prepared by:

Page 1 of 25 Needs Service Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. The list of concerns below should be further evaluated by a professional licensed contractor that specializes in that field. Exterior 1. Entry Doors: Wood -- Missing weather seal 2. Exterior Lighting: Surface mount, Light -- Exposed wiring should be in conduit 3. Hose Bibs: Rotary -- Missing anti-siphon valves Garage/Carport 4. Attached Garage Entry Doors: Hollow core -- Entry door is not rated for fire, hollow core, Missing seal 5. Attached Garage Service Doors: Metal, With glass insert -- Missing seal, the glass insert is missing components

Page 2 of 25 Garage/Carport (Continued) Service Doors: (continued) Plumbing 6. Exterior, Closet Water Heater Drain Pan Present -- No visible drain pipe noted Electrical 7. Ground: Plumbing and rod in ground -- There is no visible clamp to secure the ground cable( loose connection ) 8. Main Panel, Left side Electric Panel Manufacturer: Federal Pacific -- damaged latch noted, Federal Pacific panel breakers have a history of not tripping when circuit overloading exists 9. Main Panel, Left side Electric Panel Smoke Detector: None Present -- no smoke detectors present recommend installing smoke detectors 10. Sub Panel, Garage Electric Panel 120 VAC Branch Circuits: Aluminum -- Evaluation by a licensed electrician is recommended 11. Sub Panel, Garage Electric Panel 240 VAC Branch Circuits: Aluminum -- Evaluation by a licensed electrician is recommended

Page 3 of 25 Needs Service Summary (Continued) Air Conditioning 12. Condensing Unit, Right side AC System Exterior Unit: Pad mounted -- Unit Not secured to pad Bedroom 13. Master, Right, Front Bedroom Doors: Hollow core -- The door does not have a privacy lock, Undercut where rubbing on carpet 14. Master, Right, Front Bedroom Electrical: Light(s), Fan, Outlet(s) -- Reversed polarity, Loose outlet ( s ) should be properly secured 15. Right, Rear Bedroom Doors: Hollow core -- The door does not have a privacy lock, Undercut where rubbing on carpet, The door(s) need hardware service or adjustment to latch properly 16. Rear, midway Bedroom Doors: Hollow core -- The door does not have a privacy lock, Undercut where rubbing on carpet

Page 4 of 25 Needs Service Summary (Continued) 17. Rear, midway Bedroom Windows: Aluminum,single pane,single hung -- Broken / cracked glass Living Space 18. Family Room Living Space Electrical: Outlet(s) -- Loose outlet ( s ) should be properly secured 19. Hallway Living Space Doors: Hollow core -- The door is sticking or rubs and should be serviced at HVAC closet 20. Hallway Living Space Smoke Detector: None Present -- no smoke detectors present recommend installing smoke detectors Bathroom 21. Master bath Bathroom Windows: Aluminum,single pane,single hung -- The window (s) will need hardware serviced to function as intended, window will not open 22. Master bath Bathroom Shower/Surround: Tile floor, Tile wall -- The control valve should be further evaluated does not appear to allow hot water to fully engage ( warm water only ), The control valve should be evaluated when fully on hot water there is a pulsating effect 23. Hall bath Bathroom Tub/Shower: Porcelain tub and ceramic tile walls -- loose shower head pipe, The control valve should be further evaluated does not appear to allow hot water to fully engage

Page 5 of 25 Needs Service Summary (Continued) Kitchen 24. Range: Electric, General Electric -- The drip dishes are missing and should be installed, Oven heating element not functional at left rear, the oven top element does not turn off 25. Disposal: In-Sinkerator -- There are exposed wires that should be fully protected in conduit, There are exposed wire connection that should be properly sealed Laundry Room/Area 26. Garage Laundry Room/Area Dryer Vent: Rigid metal -- vent has been sealed Attic 27. Garage Attic Insulation: Blown in -- There are areas that are missing or do not have the required insulation, Loose fill altered, redistribute evenly 28. Garage Attic Wiring/Lighting: 110 VAC -- There are loose wires that should be properly secured

Page 6 of 25 Needs Service Summary (Continued) 29. Garage Attic Bathroom Fan Venting: Not properly vented -- Exhaust vent not properly vented

Page 7 of 25 Table of Contents Definitions 8 General Information 8 Lots and Grounds 9 Exterior 10 Structure 11 Garage/Carport 12 Roof 13 Plumbing 13 Electrical 14 Air Conditioning 16 Heating System 17 Bedroom 17 Living Space 20 Bathroom 21 Kitchen 23 Laundry Room/Area 24 Attic 24

Page 8 of 25 Definitions Not inaccessible, Obstructions, disconnected at time of or excluded by General Information Property Address 2014 Inspection way City Orlando State FL Zip 12345 Contact Name Wanda Figueroa Client Name City State FL Zip Phone (407) 466-8921 E-Mail acf@aol.com Inspector Name Company Name Property Information Client Information Inspection Company Amount Received 445.00 Present at Inspection Buyer, Buyers Agent Property Status Vacant Estimated Age 40 Inspection Date 1/1/2014 Conditions

Page 9 of 25 General Information (Continued) Start Time 10 AM Furnished No Electric On Yes Gas/Oil On Not Applicable Water On Yes Temperature 60 Weather Overcast Soil Conditions Dry Building Type Single family Stories 1 Garage Attached Water Source City How Verified Visual Inspection Space Below Grade None Additions/Modifications N/A Lots and Grounds Florida Inspection Standards of Practice General https://www.flrules.org/gateway/ruleno.asp?id=61-30.801&section=0 Not inaccessible, Obstructions, disconnected at time of or excluded by 1. 2. 3. 4. 5. 6. 7. Vegetation: Trees, Shrubs/Weeds Grading: Minor slope Exterior Surface Drain: Surface drain Driveway: Concrete Walks: Concrete Patio: Concrete, screen room Fences: Wood

Page 10 of 25 Exterior Exterior Standards of Practice https://www.flrules.org/gateway/ruleno.asp?title=home%20inspectors&id=61-30.810 The Inspection Excludes all areas that are the beyond a condo,townhouse,villas or duplex that are the responsibility of the association unless otherwise informed in writing prior to the Inspection. Not inaccessible, Obstructions, disconnected at time of or excluded by 1. Siding Type Stucco, Masonry, Block, Wood 2. Trim: Wood 3. Fascia: Wood 4. Soffits: Wood, Metal vent 5. Door Bell: functional 6., Needs Service Entry Doors: Wood -- Missing weather seal 7., Near End of Service Life Exterior Door: Aluminum Sliding Glass door ( s ) 8., Needs Service Exterior Lighting: Surface mount, Light -- Exposed wiring should be in conduit 9. Exterior Electric Outlets:

Page 11 of 25 Exterior (Continued) 10., Needs Service Hose Bibs: Rotary -- Missing anti-siphon valves 11. Exterior closet Acceptable condition Structure Florida Standards Of Practice Structure https://www.flrules.org/gateway/ruleno.asp?title=home%20inspectors&id=61-30.802 Not inaccessible, Obstructions, disconnected at time of or excluded by 1. 2. 3. 4. 5. 6. 7. Structure Type: Masonry Foundation: Poured slab Beams: Masonry Bearing Walls: Masonry Joists/Trusses: Engineered Trusses Piers/Posts: Masonry, Metal / Aluminum Floor/Slab: Poured slab

Page 12 of 25 Garage/Carport Not inaccessible, Obstructions, disconnected at time of or excluded by Attached Garage 1. Type of Structure Attached 2. Car Spaces: 2 3. Garage Doors: Metal 4. Door Operation: Mechanized 5. Door Opener: Genie 6., Needs Service Entry Doors: Hollow core -- Entry door is not rated for fire, hollow core, Missing seal 7., Needs Service Service Doors: Metal, With glass insert -- Missing seal, the glass insert is missing components 8. Ceiling: Drywall 9. Walls: Drywall, Masonry 10. Electrical: Light(s), Outlet(s), No Gfci Present 11. Floor/Foundation: Poured concrete 12., Near End of Service Life Windows: Aluminum,single pane,single hung

Page 13 of 25 Roof Florida Roof Standards of Practice https://www.flrules.org/gateway/ruleno.asp?title=home%20inspectors&id=61-30.805 Not inaccessible, Obstructions, disconnected at time of or excluded by All visible surface Roof Surface 1. Method of Inspection: Walked on roof 2. Material: Architectural Shingles 3. Type: Gable 4. Approximate Age: New 5. Flashing: Metal 6. Valleys: Asphalt shingle 7. Plumbing Vents: ABS with lead boot Plumbing Florida Standards of Practice Plumbing https://www.flrules.org/gateway/ruleno.asp?title=home%20inspectors&id=61-30. Not inaccessible, Obstructions, disconnected at time of or excluded by 1. 2. 3. 4. Service Line: Copper Main Water Shutoff: At water meter Water Lines: Copper Drain Pipes: ABS/PVC

Page 14 of 25 Plumbing (Continued) 5.Not Service Caps: None Visible 6. Vent Pipes: ABS/PVC Exterior, Closet Water Heater 7. Water Heater Operation: Functional at time of 8. Manufacturer: Whirlpool 9. Type: Electric 10. Capacity 40 Gal. 11. Approx. Age: New less than 1 year 12. Area Served: Living Areas 13. TPRV and Drain Tube: PVC 14., Needs Service Drain Pan Present -- No visible drain pipe noted Electrical Florida Standards of Practice Electical https://www.flrules.org/gateway/ruleno.asp?title=home%20inspectors&id=61-30.803 Not inaccessible, Obstructions, disconnected at time of or excluded by 1. Service Amps: 150 2. Volts: 110-240 VAC 3. 4. 5. 6. Electrical Service: Underground utilities Service Line: Aluminum Aluminum Wiring: Present through out the home Conductor Type: Romex

Page 15 of 25 Electrical (Continued) 7., Needs Service Ground: Plumbing and rod in ground -- There is no visible clamp to secure the ground cable( loose connection ) Main Panel, Left side Electric Panel 8., Needs Service Manufacturer: Federal Pacific -- damaged latch noted, Federal Pacific panel breakers have a history of not tripping when circuit overloading exists 9. Maximum Capacity: 200 Amps 10. Main Breaker Size: 150 Amps 11. Breakers: Copper and Aluminum 12. Carbon Monoxide Detector: 13., Needs Service Smoke Detector: None Present -- no smoke detectors present recommend installing smoke detectors 14. Visible panel bonding noted? No Sub Panel, Garage Electric Panel 15. Manufacturer: General Electric 16. Maximum Capacity: 200 Amps 17. Main Breaker Size: 150 Amps 18. Breakers: Copper and Aluminum 19., Needs Service 120 VAC Branch Circuits: Aluminum -- Evaluation by a licensed electrician is recommended 20., Needs Service 240 VAC Branch Circuits: Aluminum -- Evaluation by a licensed electrician is recommended 21. Visible panel bonding noted? No

Page 16 of 25 Air Conditioning Florida, Florida Standards of Practice Hvac https://www.flrules.org/gateway/ruleno.asp?title=home%20inspectors&id=61-30.804 Not inaccessible, Obstructions, disconnected at time of or excluded by Condensing Unit, Right side AC System 1. A/C System Operation: Responds to normal controls 2. Condensate Removal: PVC 3., Needs Service Exterior Unit: Pad mounted -- Unit Not secured to pad 4. Number of units 1 5. Manufacturer: Goodman 6. Area Served: Living areas 7. Approx. Age 8 8. Fuel Type: Electric 9. Temp. Differential: Acceptible 10. Type Condensing unit 11. Capacity 2.5 Ton 12. Refrigerant Lines: Serviceable condition 13. Electrical Disconnect: Breaker disconnect 14. Visible Ductwork: Fiberglass 15. Filter Location: Located at, Air handler 16. Thermostats: Individual, Located at, Hallway 17. Flow shut off switch present Yes

Page 17 of 25 Heating System Florida Standards of Practice Hvac https://www.flrules.org/gateway/ruleno.asp?title=home%20inspectors&id=61-30.804 Not inaccessible, Obstructions, disconnected at time of or excluded by Hallway, Closet Heating System 1. Heating System Operation: Responds to normal controls 2. Number of units 1 3. Manufacturer: Goodman 4. Type: Electric furnace, Forced air 5. Capacity Not labeled or identified 6. Area Served: Living areas 7. Approx. Age 5 8. Fuel Type: Electric Bedroom Not inaccessible, Obstructions, disconnected at time of or excluded by Master, Right, Front Bedroom 1. 2. 3. 4. Closet: Single Ceiling: Drywall Walls: Drywall Floor: Carpet

Page 18 of 25 Bedroom (Continued) 5., Needs Service Doors: Hollow core -- The door does not have a privacy lock, Undercut where rubbing on carpet 6., Near End of Service Life Windows: Aluminum,single pane,single hung 7., Needs Service Electrical: Light(s), Fan, Outlet(s) -- Reversed polarity, Loose outlet ( s ) should be properly secured 8. HVAC Source: Heating / cooling system register / forced air 9. Smoke Detector: Right, Rear Bedroom 10. Closet: Single 11. Ceiling: Drywall 12. Walls: Drywall 13. Floor: Carpet 14., Needs Service Doors: Hollow core -- The door does not have a privacy lock, Undercut where rubbing on carpet, The door(s) need hardware service or adjustment to latch properly 15., Near End of Service Life Windows: Aluminum,single pane,single hung 16. Electrical: Light(s), Fan, Outlet(s) 17. HVAC Source: Heating / cooling system register / forced air

Page 19 of 25 Bedroom (Continued) 18. Smoke Detector: Rear, midway Bedroom 19. Closet: Single 20. Ceiling: Drywall 21. Walls: Drywall 22. Floor: Carpet 23., Needs Service Doors: Hollow core -- The door does not have a privacy lock, Undercut where rubbing on carpet 24., Needs Service, Near End of Service Life Windows: 25. 26. 27. Aluminum,si gle pane,sin le hung -- Broken / cracked glass Electrical: Light(s), Fan, Outlet(s) HVAC Source: Heating / cooling system register / forced air Smoke Detector:

Page 20 of 25 Living Space Not inaccessible, Obstructions, disconnected at time of or excluded by Entry way Living Space 1. Closet: Single 2. Ceiling: Drywall 3. Walls: Drywall 4. Floor: Tile 5. Doors: Hollow core 6. Electrical: Light(s) 7. Smoke Detector: Family Room Living Space 8. Ceiling: Drywall 9. Walls: Drywall 10. Floor: Tile 11., Near End of Service Life Windows: Aluminum,single pane,single hung 12., Needs Service Electrical: Outlet(s) -- Loose outlet ( s ) should be properly secured 13. 14. Dining Room Living Space 15. 16. 17. 18. 19. HVAC Source: Heating / cooling system register / forced air Smoke Detector: Ceiling: Drywall Walls: Drywall Floor: Tile Electrical: Light(s), Fan, Outlet(s) HVAC Source: Heating / cooling system register / forced air

Page 21 of 25 Living Space (Continued) 20. Smoke Detector: Hallway Living Space 21. Closet: Double 22. Ceiling: Drywall 23. Walls: Drywall 24. Floor: Tile 25., Needs Service Doors: Hollow core -- The door is sticking or rubs and should be serviced at HVAC closet 26. Electrical: Light(s), Outlet(s) 27. HVAC Source: Heating / cooling system register / forced air 28., Needs Service Smoke Detector: None Present -- no smoke detectors present recommend installing smoke detectors Bathroom Not inaccessible, Obstructions, disconnected at time of or excluded by Master bath Bathroom 1. Ceiling: Drywall 2. Walls: Drywall 3. Floor: Tile 4. Doors: Hollow core 5., Needs Service Windows: Aluminum,single pane,single hung -- The window (s) will need hardware serviced to function as intended, window will not open 6. 7. Electrical: Light(s), Outlet(s), Gfci Present Counter Tops: Formica

Page 22 of 25 Bathroom (Continued) 8. Cabinet: Laminate and wood 9. Sink/Basin: Porcelain coated 10. Faucets/Traps: fixtures with a PVC trap 11., Needs Service Shower/Surround: Tile floor, Tile wall -- The control valve should be further evaluated does not appear to allow hot water to fully engage ( warm water only ), The control valve should be evaluated when fully on hot water there is a pulsating effect 12. Toilets: Standard style 13. Ventilation: Window 14. HVAC Source: Heating / cooling system register / forced air Hall bath Bathroom 15. Ceiling: Drywall 16. Walls: Drywall 17. Floor: Tile 18. Doors: Hollow core 19. Electrical: Light(s), Outlet(s), Gfci Present 20. Counter Tops: Formica 21. Cabinet: Laminate and wood 22. Sink/Basin: Porcelain coated 23. Faucets/Traps: fixtures with a PVC trap 24., Needs Service Tub/Shower: Porcelain tub and ceramic tile walls -- loose shower head pipe, The control valve should be further evaluated does not appear to allow hot water to fully engage 25. 26. 27. Toilets: Standard style HVAC Source: Heating / cooling system register / forced air Ventilation: Electric ventilation fan

Page 23 of 25 Kitchen Not inaccessible, Obstructions, disconnected at time of or excluded by 1., Needs Service Range: Electric, General Electric -- The drip dishes are missing and should be installed, Oven heating element not functional at left rear, the oven top element does not turn off 2. Ventilator: Broan 3., Needs Service Disposal: In-Sinkerator -- There are exposed wires that should be fully protected in conduit, There are exposed wire connection that should be properly sealed 4. Dishwasher: Frigidaire 5. Refrigerator: 6. Sink: Stainless Steel 7. Electrical: Light(s), Outlet(s), Gfci Present 8. Plumbing/Fixtures: Standard Fixtures 9. Counter Tops: Formica 10. Cabinets: Laminate and composite materials 11. Pantry: Single 12. Ceiling: Drywall 13. Walls: Drywall 14. Floor: Tile 15. Doors: Hollow core 16., Near End of Service Life Windows: Aluminum,single pane,single hung 17. HVAC Source: Heating / cooling system register / forced air 18. Air Gap Present? No

Page 24 of 25 Laundry Room/Area Not inaccessible, Obstructions, disconnected at time of or excluded by Garage Laundry Room/Area 1. Ceiling: Drywall 2. Walls: Drywall 3. Floor: Poured slab 4. Windows: 5. Electrical: Outlet(s) 6. Washer Hose Bib: Rotary 7. Washer and Dryer Electrical: 110 VAC, 220 VAC 8. Washer 9. Dryer 10. Washer Drain: Present 11., Needs Service Dryer Vent: Rigid metal -- vent has been sealed Attic Not inaccessible, Obstructions, disconnected at time of or excluded by

Page 25 of 25 Attic (Continued) Garage Attic 1. Method of Inspection: Entered Attic 2. Unable to Inspect: 10% 3. Roof Framing: Engineered Trusses 4. Sheathing: Plywood 5. Ventilation: Soffit vents, Roof vent, Gable vent 6., Needs Service Insulation: Blown in -- There are areas that are missing or do not have the required insulation, Loose fill altered, redistribute evenly 7. Insulation Depth: 8" 8., Needs Service Wiring/Lighting: 110 VAC -- There are loose wires that should be properly secured 9., Needs Service Bathroom Fan Venting: Not properly vented -- Exhaust vent not properly vented