Bathroom Exhaust Fan

Similar documents
Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

READ AND SAVE THESE INSTRUCTIONS

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

Easy installation in both new construction and retrofit

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Self-Cleaning Range Hoods

Easy installation in both new construction and retrofit

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

e Bath Fan with Light User s Guide

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

e Heater/Exhaust Fan/Light User s Guide

Self-Cleaning Range Hoods

Bathroom Exhaust Fan/Fluorescent Light Combination

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

breeze easytm model # F100-1W

Bathroom Exhaust Fan/Fluorescent Light Combination

HUMIDITY SENSING BATH FAN

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

VENTILATION FAN WITH LIGHT AND HEATER

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Easy installation. T080LP ENERGY STAR Lo Profile Ventilation Fan INSTALLATION GUIDE

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

VENTILATION FAN / LED LIGHT

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

READ AND SAVE THESE INSTRUCTIONS

Please Read and Save These Instructions Safety Information

Use, Care, and Installation Guide

READ AND SAVE THESE INSTRUCTIONS

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

MH70230AS MH70236AS MH70248AS

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

VENTILATION FAN WITH BLUETOOTH SPEAKER

READ AND SAVE THESE INSTRUCTIONS

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

RP, GP, XP Pro Series Installation Instructions

UNDER CABINET RANGE HOOD

READ AND SAVE THESE INSTRUCTIONS COOKING ONLY.! WARNING

High Power Range Hood

Pro Ventilation Hood Liners

INSTALLATION MANUAL AND USER GUIDE

Insulated Ventilators. Operating Instructions & Parts Manual

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

Installation Instructions Remote Blowers

READ AND SAVE THESE INSTRUCTIONS

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

READ AND SAVE THESE INSTRUCTIONS

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

INSTALLATION MANUAL AND USER GUIDE

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

Use, Care, and Installation Guide

DBF 4XL Dryer Booster Fans

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Use, Care, and Installation Guide

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Humidity and Thermostat control box for Attic Fan

Integrated Ventilation System


User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Installation Instructions Exhaust Fan With Light

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Use and Care & Installation Guide

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d

IVI WARNINGS: Must be followed carefully to avoid personal injury. [VL

Use, Care, and Installation Guide

Imperial. Read Before Starting Installation!

Model KER222. BEST BY BROAN P.O. Box 140 Hartford, WI ENGLISH...3 FRANÇAIS...12 ESPAÑOL

READ AND SAVE THESE INSTRUCTIONS GENERAL SAFETY INFORMATION

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

Use, Care, and Installation Guide

SF180 Installation Instructions

Imperial Cal Products, Inc.

User s Manual WS-5830SS WS-5836SS WS-5842SS

CVS Model Inline Multi-Port Ventilators

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

PRO VENTILATION HOOD USE AND CARE GUIDE CLEANING, MAINTENANCE, AND MORE

User s Manual HI30SS HI36SS HI42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

Installation & Maintenance Instructions

Installation. Professional Built-in Hoods

Transcription:

Bathroom Exhaust Fan Models: Installation and Operation Instructions Please read all instructions before installing and operating. All wiring and installation must be in accordance with CEC, NEC and local electrical codes. READ AND SAVE THESE INSTRUCTIONS

2 Bathroom Exhaust Fan Installation- English

IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. f ). Ducted fans must always be vented to the outdoors. g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only). h).this unit must be grounded. i). Not for use in kitchens. j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages. k).warning: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device. l). The fan must not be installed in a ceiling thermally insulated to a value greater R40. CAUTION Do not use for cooking ventilation. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. This product can be installed in a wall if mounted 8 feet or more above the floor. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. Please read specification label on product for further information and requirements. *The manual in electronic format can be download from our company web, or obtained from our dealer. Bathroom Exhaust Fan Installation - English 3

BATH FAN INSTALLATION - TOOLS AND MATERIALS REQUIRED Electrical drill or ratchet driver ½ drill bit for drilling pilot holes 1 ¼ drill bit for drilling electrical wiring access hole (if applicable) Phillips screwdriver #2 or driver bit Wire stripper or cutter Aluminum foil tape and/or duct tape Electrical supplies for wiring (i.e. marrets, electrical tape) PARTS SUPPLIED 1 Fan 1 Grille Assembly (Includes 2 Grill Spring) 4 Mounting Bracket 4 Flange Screws PLAN THE INSTALLATION 1. Do not use in a cooking area. 2. Two ways to connect ductwork to a factory-shipped unit. DO NOT MOUNT OVER COOKING AREA 4 Bathroom Exhaust Fan Installation- English

INSULATION* (Place around and over Fan Housing.) ROOF CAP* (with built-in damper) POWER CABLE* FAN HOUSING Keep duct runs short Seal gaps around Housing. * Purchase separately ROUND DUCT* Seal duct joints with tape. ROUND ELBOW(S) * WALL CAP* (with built-in damper) ROOF EXHAUST OR SIDE WALL EXHAUST Note: For best performance, use the shortest, straightest duct routing possible and avoid installing with smaller ducts than suggested. INSTALLATION STEPS 1. REMOVE PACKAGING AND SWITCH OFF POWER 2. THREE TYPES OF TYPICAL MOUNTING a) For housing mounted to I-joists (Begin at FOR JOIST OR I-JOIST MOUNTING ) b) For housing mounted to joists (Begin at FOR HANGER BARS MOUNTING ) c) For housing mounted to truss (Begin at FOR TRUSS MOUNTING ) FOR JOIST OR I-JOIST MOUNTING Step 1: Hold the housing so that it is in contact with the bottom of the joist. Attach the housing with four (4) screws to the joist through the holes in each mounting flange. FOR HANGER BARS MOUNTING Step 1: Sliding hanger bars have been provided, which allow the housing to be positioned accurately anywhere between the framing. The bars span up to 24 inches and can be used on all types of framing: I-joist, standard joist, and truss construction. Slide hanger bars onto housing and adjust as needed to fit between framing. HANGER BAR Step 2: Extend the hanger bars to the width of the framing. Position the ventilator with the hanger bar tabs wrapped around the bottom edge of the framing, holding the ventilator in place. Step 3: Secure hanger bars to framing using one screw on each end of hanger bar. Select a proper hole and secure the hanger bars together using the flange screws(provided). SCREW NAIL Bathroom Exhaust Fan Installation - English 5

FOR TRUSS MOUNTING Step 1: Snap the damper/duct connector onto the fan housing. The connector must be flush with the top of the housing, and the damper flap should fall closed. DUCT Optional: Insulated flexible duct is recommended for the quietest possible installation. If rigid duct is used, a short (1-3 feet) section of insulated flexible duct will ensure quiet operation. * FOR MODEL CB50, PLEASE READ ADDITIONAL STEPS Snap-in ans secure housing. 3. INSTALL ROUND DUCTWORK Step 1: Connect the round ductwork (not included) to the damper/duct connector, and run the ductwork to a roof or wall cap (not included). Step 2: Using aluminum tape (not included), secure all the ductwork connections so that they are air tight. 4. CONNECT ELECTRICAL WIRING FAN FAN BLACK (BLK) GROUND (GRD) Wire Panel WHITE(WHT) UNIT fan receptacle SWITCH BOX power supply 120V AC Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the wiring plate. Refer to the wiring diagram, and connect the wires as shown. INSTALL GRILLE Step 1: Install ceiling material to complete the ceiling construction. Then, cut around the fan housing. Step 2: To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille assembly, and position the grille into the housing with the grille springs in the appropriate slots. Step 3: Push the grille assembly towards the ceiling to secure. 6 Bathroom Exhaust Fan Installation- English

OPERATION Use an on/off switch to operate this fan. See Connect Wiring for details. CLEANING & MAINTENANCE For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting brush attachment. The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. The impeller should also be replaced. SERVICE PARTS WARNING: Ensure that the fan is switched off from the supply mains before replacing. PART PART NAME Qty. 1 GRILLE 1 2 SPRING 2 3 MOTOR ASSEMBLY 1 4 MOTOR 1 5 BLOWER WHEEL 1 6 WIRE PANEL ASSEMBLY 1 7 WIRE COVER 1 8 HOUSING 1 9 HANGER BARS 4 10 DUCT CONNECTOR 1 a NUTS 4 b GROMMETS 4 c MOTOR BRACKETS 1 d MOTOR MOUNTING PLATE 4 e SCREWS 1 10 9 8 7 e 9 6 5 4 d 3 c * Blower Assembly includes part 5, 4, d, 3, c, b, a. 2 b a 1 Replacement installation: Remove the screw (part c), then take out the motor plate (part 3) from the housing (part 8) by pushing down the rib in the plate while pulling out on the side of the housing. Replace the broken parts. Bathroom Exhaust Fan Installation - English 7

TROUBLESHOOTING For additional service inquiries, contact Cyclone servicing department at 1-888-293-5662 or Service@CycloneRangeHoods.com ISSUE CAUSE SOLUTION Unit does not work after installation. 1. The power source is not turned ON. A. Ensure power is ON for the circuit breaker and unit. B. Check for an open fuse or circuit breaker in the building s service panel. Light indicates power ON but motor doesn t turn. 1. Plug-in connections for motor may be loose. 1. Check that the two plug-in connections for the motor and the control are seated firmly in place. 2. Motor wiring may be damaged. 2. Change the motor. Servicing may be required. 3. The motor is not secured. 3. Tighten the motor in place. 4. Damaged blower wheel. 4. Replace the blower wheel. Servicing may be required. 5. Blower wheel assembly may be loose. 5. Check that the blower wheel is firmly attached to the motor shaft and both spin freely. Motor works but lights 1. The light bulb is loose. 1. Tighten the light bulb. do not turn on. The unit vibrates. 1. Damper in duct connector may be blocked. 1. Check that the back draft damper in the fan s duct connector pivots freely. Screws used to attached the duct to the duct connector may be preventing the damper from opening 2. Damper may be blocked or sealed shut. 2. Check that the back draft damper in the wall or roof cap pivots freely. These dampers are sometimes mistakenly painted shut or obstructed by bird and insect debris. 3. Venting duct too small or blockage in the duct opening or ductwork. 3. Check the venting duct and the wall cap or roof cap. Bath fan is not venting out properly. 1. Used the wrong size of ducting. 1. Use 6 duct work for best results. 8 Bathroom Exhaust Fan Installation- English

CYCLONE BATHROOM EXHAUST FAN LIMITED WARRANTY North America Range Hoods Inc. (hereunder called The Company ) provides a warranty that its products are free from defects in workmanship and materials for a period of one (1) year from the date of purchase for the following models: C50, C80, CB50, CB80 and for a period of three years for the following models: ESCB80 (H/L/S/HL/HM/SL/SM), ESCB110 (H/L/S/HL/HM/SL/SM), CBD120 (H/L/S/HL/HM/SL/SM), ESCB150(H/L/S/HL/HM/SL/SM). During that time period, The Company will, at the Company s option, repair or replace, without charge, any parts or complete unit found to be defective. This warranty is not transferable from the original purchaser. The company reserves the right to use functionally equivalent reconditioned parts or products as warranty replacement or as part of warranty service. Warranty does not cover the costs of removal, installation and/or transportation of defective products. THE COMPANY WILL NOT BE HELD RESPONSIBLE FOR ANY CLAIMS OVER THE ORIGINAL PURCHASE PRICE OF THE PRODUCTS NOR BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some provinces/states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. The unit removal and re-installation works are under the customer responsibility. This warranty does not cover any costs related to the products including but not limited to: a) Normal maintenance service required for the products; b) light bulbs, grill covers, adapters and other accessories for ducting; c)natural wear of the finish of the products or wear caused by improper maintenance, use of corrosive and abrasive cleaning products; d) products or parts which have been subject to freight damage, misuse, negligence, accident or any other circumstances beyond the control of The Company. e) In addition, this warranty does not apply to the following items: Damage or loss sustained in natural calamity such as fire, earthquake, flood, thunder, electrical storm, etc. Damage or loss resulting from any unreasonable use, misuse, abuse, negligence, or improper maintenance of the product. Damage or loss resulting from removal, improper repair, or modification of the product. Damage or loss resulting from sediments or foreign matter contained in a water system. Damage or loss resulting from improper installation or from installation of a unit in a harsh and/or hazardous environment. Acts of God or any circumstances beyond The Company. The warranty will be automatically void if any of the following apply: i. Used for cooking ventilation; ii. Commercial use of the products or use otherwise inconsistent with its intended purpose; iii. The function of part or the complete assembly has been modified or repaired by unauthorized person; iv. Faulty installation or installation contrary to recommended installation instructions: v. Ventilation system has not been vented to the outside or ventilation system stuck; vi. The venting duct turned downward anywhere in the venting system; vii. Wrong electrical wire connection for the fan. To qualify for warranty service you must: (a) notify us at the address and telephone number, stated below within 2 days of the discovery of the defect; (b) provide the model number and serial number; and (c) describe the nature of any defect in the product or part. At the time of requesting for service, you must present evidence of your proof of purchase and proof of the original purchase date. If we determine that the warranty exclusions listed above apply or if you fail to provide the necessary documentation to obtain service, customer will be responsible for all shipping, travel, labor and other costs related to the service. Warning! The Company will not be responsible for any defects caused by kitchen installation applications. This Product is not intended for kitchen exhaust applications. For warranty services or repair, please contact the dealer from whom you purchased the product or the address shown below. North America Range Hoods Inc. Canada: 1361 Huntingwood Drive, Unit 16, Scarborough, ON M1S 3J1 USA: 64 Salem Street, Medford, MA 02155 Tel: 1-888-293-5662 or (416) 293-0933 Fax (416) 293-4793 Email: Info@CycloneRangeHoods.com Website: www.cyclonerangehoods.com Bathroom Exhaust Fan Installation - English 9