Copyright Black Box Corporation. All rights reserved.

Similar documents
Featuring enhanced biometric security with twofactor authentication, providing the perfect blend of security and simplicity.

BLACK BOX. Join fiber ends accurately and permanently. Fusion Splicer with Core Alignment

UESR MANUAL MANUAL DEL USUARIO MANUEL DEL UTILISA TEUR BENUTZER HANDBUCH

Installation Preparation DISHWASHER CAVITY MEASUREMENTS

Installation Instructions Gas Cooktops

USER MANUAL. Read manual thoroughly prior to equipment set-up, operation or maintenance. Model Model

CEILING FAN OWNER'S MANUAL

USER MANUAL. Read this manual thoroughly prior to equipment set-up, operation or maintenance. Model

INSTALLATION INSTRUCTIONS

T3/E3 Fiber Optic Line Drivers

INSTALLATION INSTRUCTIONS

Safety Information BEFORE YOU BEGIN CAUTION: CAUTION: CAUTION: IMPORTANT Observe all governing codes. IMPORTANT Use this oven only

Installation Instructions PANOS 5.25

Safety Information BEFORE YOU BEGIN CAUTION: CAUTION: CAUTION: CAUTION: IMPORTANT Observe all governing codes. IMPORTANT Use this oven only

Safety Information BEFORE YOU BEGIN CAUTION: CAUTION: CAUTION: CAUTION: IMPORTANT Observe all governing codes. IMPORTANT Use this oven only

INSTALLATION INSTRUCTIONS

PANOS. Installation Instructions Square, 5.25 Round Flangeless, Downlight. The following installation instructions relate to the options below

INSTALLATION INSTRUCTIONS

User Manual. Glass Countertop Mechandiser Refrigerator. Single Door Model: 360GSM3HCB, 360GSM3HCW Pass-Through Model: 360GSM32HCB, 360GSM32HCW

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

PANEL_RS2. Run / Standby Panel. INSTALLATION MANUAL Version 1.02 MITSUBISHI ELECTRIC FOR INSTALLERS. Page 1 of 25

PTE0705 Electric Fence Monitor

STATUS ALARM HISTORY ALARM RESET

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Mark 25 Ultrapure Water Conductivity Analyzer

INSTALLATION INSTRUCTIONS

User Manual. Ice Cream Dipping Cabinets 178CPW47HC, 178CPSS47HC, 178CPW68HC, 178CPSS68HC

VENT-FREE GAS STOVE OWNER S OPERATION AND INSTALLATION MANUAL MODELS FDSR25 & FDSR25GF PFS

21-light Remote Annunciator. Owner s Manual

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

wireless. web-based. worthy of the name RACO.

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

INTRODUCTION / TABLE OF CONTENTS

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

380 SERIES REMOTE SIREN ETSA380R

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

_00_0517 Printed in China.

Instruction manual. W440 AIS Sart Sniffer

Installation and Operation Manual

Schneider Electric Erie T155 Series

Back Bar Refrigerator User s Manual

EL1000 Mach 3 Tech Sheet Balboa Instruments

WM3000 WIRELESS MODULES

178GDC10HC, 178GDC12FHC, 178GDC15HC, 178GDC23HC, 178GDC24FHC, 178GDC40HC, 178GDC40FHC, 178GDS47HC, 178GDC69HC

SW-2 SNOW MACHINE. Item ref: UK User Manual

Dehumidifier Déhumidificateur Dehumidificador

Power Supply Display Module PSDM. Installation and Operation Manual

OG5000 Ozone Generator Model OG5000B-A. User Manual

Product Manual. The `Safety Shoe (shown below):

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

1600PSI ELECTRIC PRESSURE WASHER EQUIPO ELÉCTRICO DE LAVADO CON AGUA A PRESIÓN DE 1600 PSI

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

TECHNICAL MANUAL *MSS92, *CSS " SINGLE STAGE MULTI-SPEED GAS FURNACE UP TO 92% AFUE

INSTALLATION AND OPERATION INSTRUCTIONS FOR

Center Cable, S.L Camino del Barranco,4-6 P.I. Las Arenas de Pinto Pinto (Madrid) Tlf

AS 300/PW - AS 400/PW - AS 1000/PW / AS 600/PW

FLT93 Installation, Operation and Troubleshooting Guide

Level Alarm Control. Blender Accessories U S E R G U I D E UGB

INSTALLATION INSTRUCTIONS

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Vertical Open Air Merchandisers 189BVAC28HC, 189WVAC28HC, 189BVAC36HC, 189WVAC36HC, 189BVAC46HC, 189WVAC46HC,

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Instruction Manual Model L2 RF Switch

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

AWR-460DB 46 Bottle Built-In Compressor Wine Cooler

MSPA-MP METAPACK SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.

Installation Instructions Range

SAFETY INFORMATION AND WARNINGS

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Alarm Tone Generator Model AG17

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Installation Guide. For Models: BW248AG6 BW248SS6 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE. net weight of fan: lb (12.

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

DM-1 Drying Monitor U S E R G U I D E UGD

Global Water Instrumentation, Inc.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Beacon 800 Gas Monitor Operator s Manual

COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Omniguard 4: Features

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Exit Stopper. STI-6400 Series

Fratech Multipath-IP

Read the entire manual before using this Machine.

Cable Drum Machine Operational Manual CP1020

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Transcription:

Copyright 1995. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 15055-1018 724-746-5500 Fax 724-746-0746

NOM STATEMENT NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY STATEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. Todas las instrucciones de operación y uso deben ser seguidas. 5. El aparato eléctrico no deberá ser usado cerca del agua por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc.. 6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante. 7. El parato eléctrico debe ser montado a la pared o al techo s ólo como sea recomendado por el fabricante. 8. Servicio El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado. 9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación. 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.

DATA ALARMS 11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato. 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato. 14. El equio eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante. 15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia. 16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo. 17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación. 18. Servicio por personal calificado deberá ser provisto cuando: A: El cable de poder o el contacto ha sido dañado; u B: Objectos han caído o líquido ha sido derramado dentro del aparato; o C: El aparato ha sido expuesto a la lluvia; o D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o E: El aparato ha sido tirado o su cubierta ha sido dañada. TRADEMARKS USED IN THIS MANUAL IBM is a registered trademark of IBM Corporation. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.

1. Specifications CHAPTER 1: Specifications Interfaces Leads Monitored Data Rate Maximum Distances User Controls Indicators SW705A: EIA RS-232; SW706A: IBM PC parallel; SW707A: EIA RS-422 pinned to RS-530 SW705A: Trans. & Recv. Data; SW706A: STROBE; SW707A: Transmitted Data SW705A: Transparent to all speeds up to 115.2 Kbps; SW706A: Transparent to all speeds; SW707A: Transparent to all speeds up to 200 Kbps Comply with those given in the official specification for each interface (2) Front-mounted: (1) RESET pushbutton; (1) DISABLE toggle switch; (2) Internal: (1) DIP bar switch for ACpower selection; (1) 9-position terminal block for alarm-output selection (2) LEDs: (1) Front-mounted: OUTPUT; (1) Rear-mounted: POWER 1

DATA ALARMS Connectors (2) Front-mounted: (1) DB25 female for data output, (1) IEC 320 power outlet; (2) Rear-mounted: (1) DB25 male for data input, (1) IEC 320 power inlet Leads/Signals Supported All (transparent to all signals) Fuse 5-amp Slo-Blo MTBF 67,000 hours Maximum Altitude 15,000 ft. (4572 m) Operating Temp. 32 to 158 F (0 to 70 C) Storage Temp. 23 to 212 F ( 5 to 100 C) Humidity 0 to 95% noncondensing Enclosure High-impact plastic Power Size Weight From outlet: Either 120-VAC, 60 Hz, or 240-VAC, 50 Hz (userselectable) through detachable 6-ft. (1.8-m) line cord to internal power supply 2.5"H x 8"W x 6.3"D (6.4 x 20.3 x 16 cm) 2 lb. (0.9 kg) 2

2. Introduction CHAPTER 2: Introduction Your Data Alarm alerts your personnel to abnormal conditions by providing AC power to another device (such as an alarm light, bell, or buzzer) when data from a third device (such as a sensor, computer, or intelligent shopfloor machine) starts flowing through the Alarm on its way to a fourth device (such as a printer or modem). You can install the alarm directly into the cable path that you want it to monitor. Figure 2-1 on the next page shows a typical application. Data Alarms are currently available in three versions: The RS-232 Data Alarm (SW705A) monitors the Transmitted Data (TD) and Receive Data (RD) leads on a serial RS-232 line; the Parallel Data Alarm (SW706A) monitors the STROBE lead on a parallel line; and the RS-422 Data Alarm monitors the Transmitted Data (TD) lead on a serial RS-422 line pinned to the RS-530 specification. (If you are using a different type of interface, or if your application requires the Data Alarm to react to the absence rather than the presence of data, call your supplier for technical support. They might be able to give you a quote on a custom unit.) If you want the Data Alarm to switch dry contacts instead of AC power, you can easily select this function by rewiring the terminal strip inside the Alarm. See Section 3.2. 3

DATA ALARMS Pipeline RS-232 Pressure Sensor Wall Outlet Data In AC In RS-232 Data Alarm AC Out RS-232 Serial Printer Data Out Alarm Bell Figure 2-1. A typical application for an RS-232 Data Alarm. 4

3. Installation CHAPTER 3: Installation 3.1 Before You Install As you unpack your Data Alarm, make sure that you received (1) Alarm unit, (1) detachable power cord, and (1) copy of this manual. If you didn t receive something, or if anything is damaged, notify your supplier immediately. Before installing your Data Alarm, put on insulated gloves. (You should always wear gloves when installing cabling or in-line devices, especially when significant voltages could be transmitted across the cables.) We also recommend that, where possible, you turn off the datasource device (the one whose data transmissions you want the Data Alarm to monitor) and data-destination device and disconnect them from their power sources. CAUTION! During installation, you should never work on both sides of your data circuit at the same time. Do not connect both cables to your Alarm simultaneously if you do, you could become part of a circuit and risk electrical shock. 5

DATA ALARMS 3.2 The Installation Procedure To install your Data Alarm, take these steps: 1. Place the Data Alarm somewhere between the devices you want to connect, within 6 ft. (1.8 m) of a working AC outlet. 2. Set the Alarm s DISABLE switch to the DISABLE (up) position. 3. If you are using 120-volt AC power, go on to Step 4. If you want 240-VAC output, you will have to set the Data Alarm s internal power-selection DIP switch. 6 CAUTION! When the Data Alarm is plugged in, 120 or 240 volts of AC power passes through its circuitry. NEVER open the unit or make any internal adjustments to it while it is plugged into a source of AC power. First open the Alarm: Unscrew and remove the two Phillips screws on the bottom of the unit and remove its cover. You will see a DIP bar switch labeled S3 and 120-VAC 240-VAC on the Alarm s circuit board. Move this switch to the 240-VAC position. 4. If you want the Alarm s output to be switched-on AC power (power comes on when data is sensed), go on to Step 5. If you want switched-off AC power (power goes out when data is sensed) or dry-contact (relay switches when data is sensed) output, you will have to rewire the Alarm s terminal block. If you haven t already, open the Alarm (see the previous step). You

CHAPTER 3: Installation OUTPUT FRONT Neutral Ground Hot TERMINAL BLOCK TB1 Terminals: Number Designation 1 Normally Closed 2 Relay Arm Factory- Installed Jumper 3 Normally Open 4 AC (Hot) Out 5 AC Neutral Out 6 Earth (AC Ground) Out 7 Earth (AC Ground) In 8 AC Neutral In 9 AC (Hot) In Hot Ground Neutral INPUT REAR Figure 3-1. The internal AC-power and relay wiring of the Data Alarms. 7

DATA ALARMS 8 will see a terminal strip labeled TB1 on the Alarm s circuit board. The terminals are wired as shown in Figure 3-1 on the next page. To get switched-off AC-power output, remove the jumper between terminals 3 and 4 and install a jumper between terminals 1 and 4. To get dry-contact output, remove the jumper wire between terminals 3 and 4, then connect your common lead to terminal 2 and your switched lead(s) to terminal 1 and/or terminal 3. The simple way to do this is to disconnect the AC-out wires from terminals 2, 5, and 6, take out the Data Alarm s removable outlet block, and run your wiring through the hole. You could also do this by detaching one or both of the AC neutral out and AC ground out wires from terminals 5 and 6 and reattaching it/them to terminal 1 and/or 3; this way, you can easily plug your wiring into, and unplug it from, the Data Alarm s outlet. (As long as no jumpers or wiring are connected to terminal 4, there is no danger of AC power coming out of the Data Alarm s outlet.) For help with this rewiring, call Black Box for technical support. 5. If you opened the Alarm in step 3 or 4, close it by replacing its cover and screwing the two screws back in. 6. If you haven t already, plug one of your data cables into the data-source device (the one whose output you want the Alarm to monitor). (As you attach your cables to devices, make sure the connectors are firmly seated.)

CHAPTER 3: Installation 7. Run this cable to the Data Alarm s location and plug its other end, which must be a DB25 male connector, into the INPUT port on the Alarm s rear panel, making sure to tighten the screwlocks. 8. If you haven t already, plug the other cable into the data-destination device. Run that cable to the Data Alarm s location and plug its other end into the OUTPUT port on the Alarm s front panel, again tightening the screwlocks. 9. Once you ve finished connecting the data lines, plug the alarm device (the one you want to get power if the Data Alarm detects data traffic) into the outlet on the Data Alarm s front panel. 10. Now plug the female end of the Data Alarm s power cord into the power inlet on the Alarm s rear panel. Plug the male end of the cord into a working AC outlet. The POWER LED on the Alarm s rear panel should light up. 11. Move the DISABLE switch on the Data Alarm s front panel to the ENABLE (left) position. 12. Plug in and turn on the data-source and datadestination devices. If the alarm device has a POWER ON/OFF switch, turn it on as well. This completes your Data Alarm installation. The Alarm system should be ready for continuous operation. 9

DATA ALARMS 4. Operation Once you have installed the Data Alarm and plugged it in, nothing further needs to be done to make the Alarm operational. Unless it stops receiving power or is damaged, the Alarm will monitor the connected data line indefinitely. However, we strongly recommend that you test your Alarm system before you depend on it to function properly in an emergency situation. To do this, force your datasource device to send data; you might be able to do this easily if the data-source device has a test setting. As soon as the Data Alarm senses the presence of data (both now, for this test, and in all future alarm conditions), the OUTPUT LED on the front panel of the Data Alarm should light up, the alarm device should emit its alarm, and the data-destination device should begin receiving the data. Assuming everything works, then to stop the alarm (both now, in this test, and in all future alarm conditions), press the RESET button on the Data Alarm s front panel. This will cut power to the alarm device, but it will not stop data from flowing to the destination device. Be aware, however, that as long as it continues to sense data, the Data Alarm will resume providing AC power as soon as you release the RESET button. For the Data Alarm to be fully restored to its normal monitoring state, you must wait until the data stops flowing through it, then press RESET. 10

CHAPTER 4: Operation If the first test fails, check each of these possibilities and repeat the test: Make sure all of your data cables and AC power cords are securely attached. Make sure all of the devices connected to the Data Alarm are plugged in and turned on. (The Data Alarm has no POWER ON/OFF switch it begins operating as soon as it is plugged in.) Make sure the Data Alarm s DISABLE switch is in the ENABLE (left) position. If the second test fails and you can t figure out why, call Black Box for technical support. If at any time you want to send data from the source device to the destination device without triggering the Data Alarm, move the Data Alarm s DISABLE switch to the DISABLE (right) position but be very careful to return this switch to the ENABLE (left) position when the transmission is finished. 11

DATA ALARMS 5.1 Calling Black Box 5. Troubleshooting If you determine that your Data Alarm is malfunctioning, do not attempt to alter or repair it. Contact Black Box Tech Support. The problem might be solvable over the phone. Before you do, make a record of the history of the problem. We will be able to provide more efficient and accurate assistance if you have a complete description, including: The nature and duration of the problem. When the problem occurs. The components involved in the problem. Any particular application that, when used, appears to create the problem or make it worse. 5.2 Shipping and Packaging If you need to transport or ship your Data Alarm: Package it carefully. We recommend that you use the original container. If you re shipping the Alarm for repair or return, include everything you received with it. Before you ship the Alarm for repair or return, contact Black Box to get a Return Materials Authorization (RMA) number. 12

NOTES

FEBRUARY 1995 SW705A SW706A SW707A Data Alarms OUTPUT RS-422 Data Alarm O U T P U T E T R E S D I S A B L E CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday: 877-877-BBOX FREE technical support, 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mail order: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com