Compendium DES July 2016, CARN

Similar documents
Pressure Enthalpy Charts

(Refer Slide Time: 00:00:40 min)

ENSC 388. Assignment #6

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Chapter 9. Refrigeration and Liquefaction

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

Performance of an Improved Household Refrigerator/Freezer

Week 9. Refrigeration Cycles I. GENESYS Laboratory

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

The Refrigeration Cycle

Last exam / sista tent

The Refrigeration Cycle

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Mechanical Engineering Laboratory

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

pdfmachine trial version

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Thermodynamics II Chapter 5 Refrigeration

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

ISSN Vol.08,Issue.21, November-2016, Pages:

Refrigeration Systems

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

R07. Answer any FIVE Questions All Questions carry equal marks *****

Vapour Compression Refrigeration Systems

LECTURE-17. Multi-Stage Vapour Compression Refrigeration. 1. Introduction

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

HVAC Fundamentals & Refrigeration Cycle

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

S.A. Klein and G.F. Nellis Cambridge University Press, 2011 = 90 F. compressor. condenser. 5 evaporator 1. evap

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Experiment Instructions. Basic Heat Pump Demonstrator

Refrigeration & Air-Conditioning. Author. Dr. A. G. Bhadaniya. Head, Dairy Engineering Department, Anand Agriculture University, Anand

Enhancement of COP in Vapour Compression Refrigeration System

RAC. Unit 1. Previous year Questions

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering

UNIT - 3 Refrigeration and Air - Conditioning

LISTOF EXPERIMENTS. S. No. NAME OF EXPERIMENTS PAGE No.

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Figure 1: Overview of CO 2 evaporator types

THE FIVE W s SYSTEMES LMP MECHANICAL SUB-COOLING. I.G.A. GIRARD, TERREBONNE, Qc. INCREASED SYSTEM EFFICIENCY & LOWER ENERGY COSTS

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Chapter 10. Refrigeration and Heat Pump Systems

VAPOR COMPRESSION HEAT PUMP USING LOW TEMPERATURE GEOTHERMAL WATER: A CASE STUDY OF NORTHERN THAILAND

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Brazed Plate Heat Exchanger for CO Applications

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Thermodynamics: Homework A Set 7 Jennifer West (2004)

MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

Tube-in-tube heat exchanger Type HE

Engineering Thermodynamics. Chapter 7

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2013) 2 / 25 T270 COP R = Q L

Energy Use in Refrigeration Systems

Sarthak Thakar, 2 R.P.Prajapati 1

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Refrigeration Cycles. Refrigerators, Air-conditioners & Heat Pumps. Refrigeration Capacity/Performance. Dr. Md. Zahurul Haq

T270 COP R = Q L. c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2017) 2 / 23 T354

INSTITUTE OF AERONAUTICAL ENGINEERING

Sabroe MatchMaster Program COMP1

Steam Power Cycles Part II

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

4.1 Refrigeration process comparison

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Refrigeration and Air Conditioning

Design of a Low capacity Evaporator of a Refrigeration Unit

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

ADVANCES in NATURAL and APPLIED SCIENCES

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

Refrigerant Glide and Effect on Performances Declaration

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

Natural gas liquefaction cycles


Homework Chapter2. Homework Chapter3

Transcription:

Compendium DES July 2016, CARN 1

Contents Contents... 2 1. Energy balance... 4 Using Energy Balance for analyzing energy systems... 4 Energy Balance definition... 4 Steady state, steady flow... 4 Methodology... 4 Energy balance examples... 5 Overall system, refrigeration or heat pump... 5 Evaporator, air cooled... 5 Evaporator, water cooled... 6 Compressor... 6 2. Refrigeration cycle... 7 Refrigeration cycle and log p,h diagram... 7 Evaporaration process (4-1)... 8 Condensation process (1-2)... 8 Expansion process (3-4)... 9 Compression process (1-2)... 9 3. Coefficient of Performance - COP... 10 COP definition... 10 COP calculation... 10 Refrigeration system... 10 Heat pump... 10 Seasonal performance factor -SPF... 10 4. Mass flow and capacities... 11 Cooling capacity... 11 Condenser capacity... 11 Compressor capacity and volumetric efficiency... 11 5. Details in the refrigeration cycle... 13 Superheating... 13 Subcooling... 13 Superheating and subcooling with internal heat exchanger... 13 A Cooled Compressor... 15 2

6. Refrigerating plants with CO2 and HC... 16 CO2 refrigerant... 16 One stage refrigeration plant with direct expansion... 17 Two stage refrigeration plant for freezing and cold storage... 18 Refrigeration plants with HC refrigerants... 20 7. Pipe dimensioning... 21 3

1. Energy balance Using Energy Balance for analyzing energy systems Energy Balance definition Energy cannot be created or destroyed, only modified in form (First Law of Thermodynamics). For a defined control volume there is a balance between supplied and extracted energy if the system is steady state. If there is no balance energy will be added to (stored) or removed from the control volume, and the system is non-steady (dynamic). A control volume can be defined for a total system (eg. a cold storage room, a refrigeration system/heat pump) or for a component (eg. a heat exchanger, a compressor, an expansion valve, a tank). Control volume Energy in Energy out Figur 1 Steady state, steady flow Mass balance: Σq m_in = Σq m_out [kg/s] Energy balance: ΣE in = ΣE out [kw] Heat Work or electricity ΣΦ in + ΣP in = ΣΦ out + ΣP out [kw] Heat: Heat to or from environment Mass flow with latent heat change Mass flow with sensible heat change ΣΦ = ΣΦ + Σ(q m h) + Σ(q m c p Δt) [kw] Methodology Draw a simple model of the system using standard symbols 4

Add numbers to identify the different parts of the process Add know information on eg. massflow, temperatures, pressure to the drawing Draw Control Volumes for the total system and parts of the system to be analyzed. Find enthalpies for latent processes: Refrigerants (log P h-diagram), air with condensation or humidification (hx-diagram). Find c p values for sensible processes: Water, dry air and other substances (tables) Calculate energy flow in and out of each control volume using energy balance equations. Energy balance examples Overall system, refrigeration or heat pump Φ evaporator + P compressor = Φ condenser [kw] Φ c 3 2 P comp 4 1 Φ e Evaporator, air cooled Refrigerant Air qma, tin, RHin qmr, P4, t4 qmr1, P1, t1 qma, tout, RHout q mr h 4 + q ma h in = q mr h 2 + q ma h out [kw] or q mr (h R1 h R2 ) + q ma (h A1 h A2 ) = 0 [kw] 5

Specific enthalpy is found in tables Evaporator, water cooled Refrigerant Water qmw, tin, Pin qmr, P4, t4 qmr1, P1, t1 qmw, tout, Pout q mr h 4 + q mw c p_in t in = q mr h 1 + q mr c p_out t out [kw] or q mr (h 4 h 1 ) + q mw (c pwin t Win c pwin t Wout ) = 0 [kw] Compressor q mr, P2, t2 Refrigerant Shaft q mr, P1, t1 Pshaft q mr h 1 + P shaft = q mr h 2 [kw] 6

2. Refrigeration cycle Refrigeration cycle and log p,h diagram The diagram shows different phases: Liquid, saturated liquid (transition from liquid to wet region), wet region (mixture between vapour and liquid), saturated vapour (transition between wet region and superheated) and superheated phase. Furthermore, the following curves are depicted in the diagram: Isothermal, isochoric and isentropic curves. 7

Single stage refrigeration cycle in log P,h diagram: To draw the refrigeration process in a log P h diagram the following steps can be used. Evaporaration process (4-1) The evaporation pressure is determined by the evaporation temperature and the chosen refrigerant. Because of the evaporation pressure and temperature will be constant during the process. The evaporation temperature t o depends on the purpose of use. If the evaporator is to cool the air in a cold store to a given storage temperature t s, the evaporation temperature t o must be lower than t s in order for the heat from the cold store to flow into the evaporator. The evaporation temperature t o is normally 5-10 C lower than t s. The quality x is connected to the wet area and expresses the ratio between the vapour and liquid fractions. If the suction state 1 is in the wet region then x 1 is less than 1. This will not be acceptable since the compression of wet vapour will damage the compressor. Fluid droplets that are sucked into the compressor will evaporate promptly and be highly damaging to the compressor. The temperature t 1 must hence be equal to or larger than (=superheated) the temperature in saturated vapour state. Condensation process (1-2) The condensing temperature t c is determined by the fluid to which the heat from the condenser is transferred. This heat is often given off to outside air or cooling water e.g. seawater. The condensing temperature t c is normally 10-15 C higher than the outside air/cooling water temperature. The quality x 3 must be equal to 0 and the temperature t 3 must be equal to or smaller than (=subcooled) the temperature in saturated liquid state. 8

The temperature t3 after the condenser should be the same or lower than the condensation temperature, meaning that the refrigerant is liquid to avoid flash gas in the expansion valve. If state 3 is on the liquid side of the saturation curve (=subcooled). Expansion process (3-4) During the expansion process there will be no transfer of energy to or from the environment so h4=h3. Compression process (1-2) The temperature t 2 after the compressor is determined by the efficiency of the compressor and cooling of this. The ideal process is isentropic, which is defined as adiabatic (Q 12= 0) and frictionless (W diss12 = 0). The actual temperature t 2 will be higher than the theoretical t 2s since frictional heat cannot be avoided. Immediately after the compressor, the gas is strongly superheated. The superheated gas is cooled down in the condenser from t 2 to the condensing temperature t c. The calculation of the actual enthalpy h 2 after the compressor depends on its isentropic efficiency η s. The ideal compression process will have constant entropy, meaning that the process vill follow the isentropic curve and the intersection with the condensation pressure will be stage 2s. h 2s is enthalpy at discharge valve for the ideal compression process. For a real process and if the compressor is uncooled, the friction losses are transferred to the refrigerant gas. In this case η s is defined only by the enthalpies: h h h 2s 1 2 h1 s [kj/kg] h 2 is enthalpy at discharge valve for the real compression process. h 1 is enthalpy at compressor inlet suction valve. η s is the compressors isentropic efficiency. It is depending on compressor type and pressure ratio between condensing pressure and evaporation pressure. The diagram below shows typical values for η. (η v is volumetric efficiency). 9

3. Coefficient of Performance - COP COP definition As a measure of the efficiency of a refrigeration system or a heat pump, Coefficient Of Performance = COP is used. This factor cannot be compared to an efficiency as COP is normally greater than 1. Of course, this relationship does not mean that a refrigeration system or a heat pump work as perpetual motion machines. The COP can be formulated as useful energy divided by supplied energy. COP = Useful energy Paid energy COP calculation Refrigeration system COP cool = q o w i If the efficiency of the electrical motor, fans and pump is included, we get: COP cool = Φ o P el Heat pump COP HP = q c w i If the efficiency of the electrical motor, fans and pumps is included, we get: COP HP = Φ c P el COP factors provides a snapshot of the operating conditions at certain temperatures and loads. It is evident that a high COP value yields the lowest operational expenses. Seasonal performance factor -SPF The COP factor is measured by using specific test data and often describe performance for worst case based on design data. Since the outdoor temperatures change during the year, the COP for the plant will also vary according to the season. To achieve an exact calculation of the operational expenses, a seasonal performance factor SPF must be used instead. To get an accurate picture of how efficient the heat pump functions over longer time, we can calculate the seasonal COP of the heat pump, where the whole year, summer and winter is taken into account. Seasonal performance factor COP season is an average for the whole year. The factor is called SPF and is defined by: SPF COP season Annual energy production ( J or kwh) Annual electricit y consumption ( J or kwh) Often annual SFP is found using monthly values for energy demand and COP. 10

4. Mass flow and capacities Refrigerant mass flow Refrigerant mass flow rate q mr is calculated from evaporator or condenser capacity. For a cooling plant a given cooling capacity Φ o is needed: q mr = Φ o h 1 h 4 [kg/s] For a heat pump a given condenser capacity Φ c is needed: q mr = Φ c h 2 h 3 [kg/s] Cooling capacity The cooling capacity is describing the cooling performance of the refrigeration systems. The cooling capacity is the same as the evaporator capacity. Φ o = q mr (h 1 h 4) = q mr q o [W] Condenser capacity The condenser capacity is describing the heat from the condenser to the environment. Φ c = q mr (h 2 h 3) = q mr q c [W] Compressor capacity and volumetric efficiency The compressors capacity is characterized by the real volume flow rate q v1 in the suction inlet valve. The volume flow rate in the suction pipe depends on the compressors teortical swept volume q v,s and the pressure ratio between evaporation pressure and condenser pressure. The real volume flow rate q v1 will always be lower than the theoretical q v because of e.g. recompression of refrigerant vapour from cylinder top space, pressure drop in valves, leak from high pressure side to low pressure side, heating of refrigerant in suction inlet. The volumetric efficiency η v is defined as the ratio between actual volume flow rate and the theoretically swept volume: η v = q v1 q v,s = q mr v 1 q v,s The diagram below shows typical values for η v. 11

For a compressor with a given q v,s and η v, the capacity is given by: Φ o = q mr q o = q v,sη v v 1 q o = q v,s η v q o,v [W] where q o,v is the specific volumetric refrigerating capacity q o,v = q o v 1 [kj/m 3 ] 12

5. Details in the refrigeration cycle Superheating The state 1 at the compressor suction inlet can be saturated vapour state or superheated. The actual state is linked to the regulation of the evaporator. If t 1 = t o the vapour at the compressor inlet is saturated. If t 1 > t o the vapour to the compressor is superheated. The superheating is controlled by the expansion valve. We are often dealing with a superheating in the range of Δt sh = 2-8ºC. The main purpose of superheating is to avoid liquid in the compressor. Subcooling The state 3 right after the condenser must be saturated liquid or subcooled. A liquid is said to be subcooled, when its temperature t 3 is lower than the condensing temperature t c that corresponds to the condensing pressure. The subcooling Δt sc = t c t 3 occurs by cooling in the bottom part of the condenser where there is liquid. Furthermore, the subcooling can also occur in pipes- and the receiver after the condenser- it is normal practice that these pipes are not insulated. Subcooling avoids flash gas in the expansion valve. If the refrigerant just before the expansion valve enters the wet region state, gas bubbles in the liquid are formed- this is called flash gas. Flash gas can lead to disruptions in the operation, as the expansion valve gets a lower capacity. We are often dealing with a subcooling of Δt sc = 2-10ºC. Another benefit of subcooling is increased cooling capacity Φ o. Superheating and subcooling in the log p,h diagram is shown below: Log p,h Subcooling Δt sc 3 t c 2s 2 to Δt sh 4 q o = h 1 h 4 1 Superheating h Superheating and subcooling with internal heat exchanger Super heating and subcooling can be obtained using an internal heat exchanger. 13

The figure shows a system with an internal heat exchanger. In this, heat is exchanged between the liquid flow from the condenser and the suction gas to the compressor. The process is drawn in the log p, h diagram: Evaporator Condenser qmr1, h1 qmr3, h3 qmr1, h1 qmr3, h3 Since the mass flow of liquid from the condenser and the suction gas to the compressor are the same, the energy balance will yield the following equation: Φ 33 = Φ 11 = q mr3 (h 3 h 3 ) = q mr1 (h 1 h 1) [W] If there is only one evaporator (q mr1 = q mr3) then q ih = h 3 h 3 = h 1 h 1 [kj/kg] 14

It is seen that the internal heat exchanger gives both increased subcooling and increased superheating. Therefore, for certain refrigerants, a higher COP is achieved while the opposite will be true for other refrigerants, cf. the paragraph on superheating. Internal heat exchange decreases the risk of flash gas in the liquid pipe and in certain cases it can reduce the risk of intake of wet suction gas or liquid chock in the compressor. Please also note the increased temperature t 2 after the compressor. A Cooled Compressor Cooling a compressor means that heat is removed from during the compression process. Φ 12 is the heat flow from the compressor to the surroundings (compressor cooling). q mr, h2 Refrigerant qmr, h2 P 12 Using the energy balance for the compressor we get: P i12 + Φ 12 = q m,r (h 2 h 1) or P i12 = q m,r (h 2 h 1) - Φ 12 [W] If we want to determine the enthalpy h 2 in the compressor outlet valve we will find: h 2 Pi 12 h1 q m, R 12 h 1 Pi 12s s q m, R 12 [KJ/kg] (3.8) The enthalpy h 2 can then be plotted into the log p,h diagram. 15

6. Refrigerating plants with CO 2 and HC CO2 refrigerant The critical point is reached at 31 C and 74 bar Generally, plants operate in trans-critical mode a part of the year. In this case there is no condensation after the compressor; the refrigerant is cooled in a gas-cooler. It is possible to have traditional operation (sub-critical) in winter time when outdoor temperature is low. The different phases of CO2 is shown on the log p,h diagram below: 16

One stage refrigeration plant with direct expansion There are several possible plant designs. A typical circuit with direct expansion has expansion in two steps and a build-in inter-stage receiver. To ensure sub-cooling before the second expansion valve there is mounted an internal heat exchanger (see figure below): Traditional sub-critical operation: The refrigerant is condensed in gas-cooler and high pressure expansion valve is fully open. The process is as usual. Trans-critical operation: The high pressure gas from compressor flows to the gas-cooler where the gas is cooled. The outlet temperature is regulated by the high pressure expansion valve. After the first throttling the refrigerant is in liquid / vapour region and stored in the receiver. The liquid flows through the internal heat exchanger which ensures sub-cooling. The second expansion valve is overheat regulated and works as usual thermostatic expansion valve. See the principal process in log p,h diagram below: 17

Two stage refrigeration plant for freezing and cold storage In most cases there will be more than one room to cool down and each room will have different temperatures. A cold store often contains a cold store room with minus temperature and cold storage rooms with plus temperatures. In this case a possible design could be with a two-stage compression and an interstage receiver as shown below: Traditional sub-critical operation: Expansion valve 1 is fully open and the pressure regulated valve is closed. The principal process in log p,h diagram can be seen below: 18

Trans-critical operation: There is a throttling from gas-cooler to interstage pressure in expansion valve 1. The interstage pressure is regulated by the pressure regulated valve. The liquid flows from the receiver through the internal heat exchanger, which ensures sub-cooling. The second expansion valve is overheat regulated and works as usual thermostatic expansion valve. See principal process in log p,h diagram below: Alternatively of two-stage compression cascade cooling plants could be used 19

Refrigeration plants with HC refrigerants R 600a (Isobutane) for small plants/fridges R 290 (Propane) for large plants The substance has good thermal qualities and is an effective refrigerant (high COP). You can easily buy all main components and regulators. The problem is that the substance is highly flammable. Therefore, it is difficult to use it in extensive plants, for example plants with direct expansion in cold storage rooms. A possibility is plants with indirect expansion and with circulating brine to cool air coolers in cold storage rooms. In this case the circuit with HC refrigerant is very compact and easier to protect against fire. Diagram for indirect expansion and brine: 20

7. Pipe dimensioning The choice of pipes which connect the components is a compromise between: - Minimum velocity so that the oil is transported back to the compressor - Not too high pressure loss due to operational expenses - Not too large pipes due to investment The piping system must hence be designed so that the oil is led through the pipes and back to the compressor. The choice of refrigerant velocity, c, in the pipes and hereby choice of dimension is a complex area where one should consult special literature or a refrigeration consultant. The following velocity indications are guidelines: Suction pipe: Discharge pipe: Liquid pipe: 5 20 m/s 8 18 m/s 0.4 1 m/s The internal pipe dimension d i is calculated based on the volume flow q v and the velocity c: q v = q mr v = c π 4 d i 2 d i = q mr v 4 c π v Specific volume, m 3 /kg c Velocity, m/s The specific volume, v, can be determined from the log p,h diagram and the type of pipe: Specific volume and type of pipe. 21

The pressure drop Δp [Pa] lost to friction is calculated from: Straight pipes: Δp = λ L d i 0,5 ϱ c 2 Minor losses: Δp = ζ 0,5 ϱ c 2 Where ρ = 1 v Density, kg/m3 λ Pipe friction factor L Pipe length, m 22