Reflex Longtherm. Soldered plate-type heat exchanger. Operating instructions

Similar documents
SB Series Brazed Plate Heat Exchanger Installation Manual

BRAZED PLATE HEAT EXCHANGERS

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Instruction Manual. Pharma-line ESE02198-EN Original manual

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Installation and operating instructions. DK energy storage and DK energy buffer

LONGONI ENGINEERING SRL

BOILER HOUSE PRODUCTS GMS

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Air Cross 21 Installation and User Manual

SERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

Instruction and Maintenance Manual. Spiral Heat Exchanger

ANLAGENBAU HEAT EXCHANGER w w w. a nla g enba u-b oehm er. d e Version 05/2015

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

Friwa Compact. Operating instructions EN

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

BRAZED PLATE HEAT EXCHANGERS MOUNTING AND OPERATION MANUAL

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

SMK 22 SMK SMK SMK 22-82

Rycroft Supapac Plate Heat Exchangers

General safety precautions English

1. Description. 2. Application and Installation Considerations

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

FRISTAR Fresh water station

Description. Main components. Lifting eyes To used for lifting and transport securing. Carrying bar Carries the cassettes and the pressure plate.

Inverted Bucket Steam Traps

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

Instruction Manual. 1. Introduction

Model: 1100 Float-Controlled Condensate Trap, PN 25

VS SERIES NH3 STEAM VAPORIZERS OPERATION MANUAL

Quality Heat Exchangers

HKF 8180 Operating instructions

General safety precautions English

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

Ventilation and air conditioning QUALITY FOR LIFE. Refrigerating systems and heat pumps. Operating manual

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers

Installation and Operation Manual IDRA PLUS DS. Solar Solar storage cylinder. Installation and Operation Manual

BK 45 BK 45-U BK 45-LT BK 46

HELMUT KÄMPKEN GMBH OPERATING MANUAL

Daikin Water Cooling, Heating, and High Capacity Booster Coils

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

TECHNICAL INSTRUCTIONS

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Model: 1200 Model: 1200-G Model: 1200-N Float-Controlled Condensate Trap, PN 40

Brazed Plate Heat Exchangers TTP s Series

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

B 400. Operating Manual Humidifier B 400

USER S INFORMATION MANUAL Model: HSE 125 N/P, HSE 145 N/P Gas-fired, Condensing Boiler and Instantaneous Water Heater

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

General Maintenance and Operating Instructions for Heat Exchangers

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

HYDRAULIC OIL COOLER. Installation, Operation & Maintenance Guide

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

General safety precautions English

General safety precautions English

Niles Steel Tank Hot Water Generator Installation and Operation Manual

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

USER MANUAL INSTALLATION INSTRUCTIONS WARRANTY REGISTER

Decentralised ventilation units

OPTIBAR P 1010/2010 C Supplementary instructions

W A V E. Operating Manual SOLU T I O N I N A S P E C IAL D E S I G N E D ITI O N

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Thermostatic mixing valves with interchangeable cartridges

In the event of this condition, consult the Authorities Having Jurisdiction for guidance and approval.

Table of Contents. English

FIGURE 1. Model RD107

OPTIBAR DP 7060 Supplementary Instructions

SYSTEMS for CATALYTIC FILTERS

Oil burners fuel unit with solenoid valve

TTK 70 S OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK70S-TC-001-EN

Quality Heat Exchangers

STORAGE TANK INSTALLATION and OPERATION MANUAL

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

MFP14 Automatic pumps. for condensate and other industrial fluids

Installation, Operating and Servicing Instructions

ispring Whole House Water Filter Systems USER S MANUAL

RESISTENT PLUS D A CH Gebrauchsanleitung GB IRL AUS USA NZ CDN IND Instructions for Use... 12

HRS Heat Exchangers Instruction Manual

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

REG NO FM BS EN ISO HEADER TANK HEAT EXCHANGER. Installation, Operation & Maintenance Guide

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

Level Electrode NRG Original Installation Instructions English

Instruction Manual Plate Condenser. AlfaCond 400/600/800. Part number

Brazed heat exchanger XB

RX550i Electric Pressure Washer

Transcription:

Reflex Longtherm Soldered plate-type heat exchanger 09-2016 EN Operating instructions

English Refle x Longth erm Contents 09-2016 Contents 1 Safety... 3 1.1 Personnel requirements... 3 1.2 Instructions for personnel... 3 1.3 Intended use... 3 1.4 Impermissible operating conditions... 4 1.5 Residual risks... 4 2 Product description... 5 2.1 Identification... 5 3 Technical data... 6 3.1 General technical data... 6 3.2 Assemblies... 7 4 Installation... 9 4.1 Connection... 9 4.2 Connection diagram... 11 5 Commissioning, operation and decommissioning... 12 6 Maintenance... 13 7 Removal... 13 8 Annex... 14 8.1 Reflex Customer Service... 14 8.2 Inspection... 14 8.3 Warranty... 14 8.4 Glossary... 14 8.5 Conformity and standards... 15 2 English Reflex Longtherm 09-2016

1 Safety 1.1 Personnel requirements Installation and operation tasks are to be carried out by specialist personnel or specially trained personnel only. Safety 1.2 Instructions for personnel Modifications of the plate-type heat exchanger are not permitted: Welding at other locations than the connection piece. Mechanical deformations. Plate-type heat exchanger with visible damage. Ignoring this manual and the safety information in particular, may cause the destruction and defects of the plate-type heat exchanger, endanger persons and adversely affect the functioning. Any contravention voids the guarantee and liability. 1.3 Intended use Plate-type heat exchangers ("heat exchangers") are copper-soldered and used for the system isolation of contra-directional water circuits. They are used for exchanging the thermal energy between the water circuits in heating or drinking water systems. Operation with a water/glycol mixture is approved. When the heat exchanger is operated with ionised water, the increased concentration of copper ions in the water must be taken into consideration. The oxygen content must then not exceed 50 mg/litre. Reflex Longtherm 09-2016 English 3

Safety 1.4 Impermissible operating conditions The heat exchanger is not suitable for the following conditions: Use with aggressive water corroding the plate material or the copper solder. Ammonia- and sulphur-containing water, acids and brines. Water containing hydrogen sulphide, sulphate or sulphite. Use in galvanised pipe systems and in facility systems prone to water hammer. 1.5 Residual risks The heat exchanger has been manufactured using state-of-the-art technology. Despite this, residual risks cannot be excluded. Caution risk of burning! Hot surfaces in heating systems can cause burns on the skin. Wear personal protective equipment: Protective gloves, protective clothing. Please place appropriate warning signs in the vicinity of the device. Warning large weight! The devices are heavy. Consequently, there is a risk of physical injury and accidents. Use suitable lifting equipment for transportation and installation. Caution risk of injury! The devices carry a water pressure of up to 31 bar at temperatures up to 195 C. Incorrect installation, removal or maintenance work may cause burns or other injuries at the connection points, when pressurised hot water or vapour suddenly escapes. Use suitable personal protective equipment (safety clothing, gloves and goggles). Ensure proper installation, removal or maintenance work. Wait for the device to have cooled down before starting removal or maintenance tasks. Ensure that the system is de-pressurised before performing installation, removal or maintenance work at the connection points. 4 English Reflex Longtherm 09-2016

Product description 2 Product description The heat exchanger comprises several, in-series arranged stainless steel plates. Copper soldering at contact points connects the stainless steel plates. Channels are impressed in the surfaces of the stainless steel plates. These channels form two contra-directional and isolated flow spaces for two water circuits. The flow spaces differ by two channel designs: rhc - channel: Large thermally-effective length of flow channels with large flow resistance. rlc - channel: Small thermally-effective length of flow channels with small flow resistance. The plate-type heat exchangers are organised in various assemblies, see chapter 3.2 "Assemblies" on page 7. 2.1 Identification The nameplate provides information on manufacturer, year of manufacture, part number and technical data. Reflex Longtherm 09-2016 English 5

Technical data 3 Technical data 3.1 General technical data The general technical data at static operating conditions apply to the following assemblies: Max. gauge operating pressure 31 bar Max. operating temperature 195 C Max. temperature difference between the flow spaces t Kelvin 100 k Plate material Stainless steel 1.4401 Solder material Copper The corrosion behaviour of stainless steel 1.4401 and copper must be taken into consideration. Comply with these values for the media used. Component of water Unit Characteristic value ph value -- 7 9.0 Electric conductivity µs / cm 10 500 Sulphate < 100 Ammonia < 2 Nitrates mg / litre < 100 Iron < 0.2 Manganese < 0.1 Chlorides 50 C < 300 75 C mg / litre < 100 90 C < 10 >100 C Not permitted Free chlorine < 0.5 mg / litre Free carbonic acid < 20 Saturation index SI ph -0.2 +0.2 Total hardness dh 6 15 Suspended solids < 30 Hydrogen sulphide < 0.05 Hydrogen carbonate < 300 mg / litre Hydrogen carbonate / Sulphate > 1.0 Sulphide < 1.0 Nitrite < 0.1 6 English Reflex Longtherm 09-2016

Technical data 3.2 Assemblies Plate-type heat exchanger sizes Sizes 15 / 40 / 60 Sizes 85 / 150 / 200 Sizes 85 / 150 / 200 / 300 Channel form / size Width mm Height mm Connection B b H h rhc 15 74 40 204 170 G3/4 rhc 40 124 73 335 281 G1 rhc 60 124 73 532 478 G1 1/4 rhc 85 / rlc 85 271 200 532 460 G2 rhc 150 271 161 532 421 G2 1/2 rhc 200 271 161 802 690 G2 1/2 rhc 85 / rlc 85 271 200 532 460 DN 50 / PN 60 rhc 150 271 161 532 421 DN 65 / PN 40* rhc 200 271 161 802 690 DN 65 / PN 40* rhc 300 386 237 875 723 DN 100 / PN 40* Reflex Longtherm 09-2016 English 7

Technical data Heat insulation rhc 15 / 40 / 60 / 85 ; rlc 85 rhc 150 / 200 / 300 Two half shells from rigid polyurethane foam with connecting clips. Heat insulation from mineral wool with aluminium exterior coating. Brackets Size Bracket Dimension Mount design Transport lug a / mm b / mm c / mm rhc 85 / rlc 85 x -- 140 600 -- rhc 150 x -- 160 581 -- rhc 200 x x 160 850 966 rhc 300 x x 231 954 1088 Connection Size Screw connection with flat gasket, brass Solder connection, brass Welding connection, steel rhc 15 G¾ x G½ G¾ x 18 mm G¾ x 21.2 mm rhc 40 G1 x G¾ G1 x 22 mm G1 x 26.9 mm rhc 60 G1¼ x G1 G1¼ x 28 mm G1¼ x 33.7 mm rhc 85 / rlc 85 G2 x G1½ -- G2 x 48.3 mm rhc 150 / 200 G2½ x G2 -- G2½ x 60.3 mm Butt flanges Size Connection size Material rhc 150 / 200 DN 65 x 76.1 mm Steel or, optionally, stainless steel rhc 300 DN 100 x 114.3 mm *Butt flanges are special models and should be ordered specifically. 8 English Reflex Longtherm 09-2016

Installation 4 Installation Caution Property damage from dynamic loads from the system Dynamic loads from the facility system such as water hammer, re-evaporation, cavitation and unstable temperature regulation will damage the device. Ensure stable pressure and temperature regulation for the heat exchanger. Avoid re-evaporation and cavitation. 4.1 Connection Comply with the general instructions for connections: Connect the water circuits according to the counter-flow principle. Connect the water circuit with the larger temperature range and the small flow rate to s 1 / s 2. The s 1 / s 2 connection end is identified by a red dot. Install the devices for shut-off, draining and ventilation directly upstream of the heat exchanger to ensure unimpeded servicing. Install the draining devices directly upstream of the lower connecting lines s 2 and s 3. Install the ventilation devices directly upstream of the upper connecting lines s 1 and s 4. If appropriate, install filters in the feed pipes for protecting the heat exchanger. For open systems, filters with a mesh width of maximal 0.08 mm. For closed systems, filters with a mesh width of maximal 0.8 mm. Reflex Longtherm 09-2016 English 9

Installation Comply with the instructions for thread connection: Use only flat-sealing union nuts at the thread connection. Tighten the thread connections only to the maximum torque provided. Bending and torsion moments for thread connections Connection force Bending moments Torsion moments Size T (kn) F (kn) Mb (Nm) Mv (Nm) rhc 15 1.5 8.0 40 170 rhc 40 10 385 2.5 65 rhc 60 25 765 rhc (rlc) 85 11.5 30 740 1000 rhc 150 / 200 rhc 300 15 40 980 1300 Comply with the instructions for soldered connections: Prepare the surface of the connection of heat exchanger and copper pipe. Clean, de-grease and polish. Remove oxides. Fill the inside of the heat exchanger with nitrogen to prevent oxidation. Apply flux. Protect the heat exchanger from overheating. For example, use a wet cloth to cool the soldering area. Use only solder material with a silver portion of 45 55%. Do not exceed the maximum soldering temperature of 650 C. Do not point the soldering flame in the direction of the heat exchanger. During soldering, ensure the fixed position of the copper pipe. Comply with the instructions for welded connections: Use only TIG welding. Fill the inside of the heat exchanger with nitrogen to prevent oxidation. Protect the heat exchanger from overheating. For example, use a wet cloth to cool the soldering area. 10 English Reflex Longtherm 09-2016

4.2 Connection diagram Installation The water circuit with the large temperature range is the source of heat and the primary side in the facility system. The secondary side is the heat consumer. Ensure regulation stability with a "TC" temperature controller and a "TAZ+" temperature limiter. Install the controller immediately downstream of the secondary side outlet. Reflex Longtherm 09-2016 English 11

Commissioning, operation and decommissioning 5 Commissioning, operation and decommissioning Caution Device damage from overheating! Incorrect opening of the water circuits may overheat the heat exchanger. Open first the secondary side before opening the primary side. Proceed as follows for commissioning: 1. Fill the facility system and the heat exchanger with water. Simultaneously and slowly open the valves in the supply and return of primary and secondary side until the operating temperature is reached. 2. Vent primary and secondary side. 3. Shut off the primary side. 4. Create the circulation of the water circuit in the secondary side. Use a recirculating pump, for example. 5. Create the circulation of the water circuit in the primary side. Note! Avoid re-evaporation and cavitation. The pressure at primary and secondary side must be at least 0.5 bar above the water saturation pressure. Comply with these instructions when using pumps: Use shut-off valves. Use pressure relief valves to ensure the permissible operating pressure of the heat exchanger. Avoid air being drawn in. This prevents water hammer. Start the pumps against the closed shut-off valves. This prevents pressure surges. Commissioning is competed and the heat exchanger is ready for operation. Decommissioning: For an extended standstill time, drain the heat exchanger. This is particularly important for aggressive or bacteria-forming water (bio-fouling, for example). Proceed as follows: 1. Shut off the primary side. 2. Shut off the secondary side. 3. Shut off the outgoing pipes. Use the pressure maintenance to prevent vacuum from forming due to the water cooling down. 12 English Reflex Longtherm 09-2016

Maintenance 6 Maintenance Caution Property damage from the use of cleaning agents Cleaning agent may corrode and damage the materials used in the heat exchanger (e.g., stainless steel, copper or nickel). Comply with the safety instructions and recommendations of the cleaning agent manufacturer. Use chloride-free or low-chloride water with low hardness. Inspect and clean the unit exterior once per year. Exterior inspection: For damages. For leaks. Strain-free position in the facility system. Cleaning: Purge and clean the heat exchanger. If the water quality causes excessive deposit (due to, e.g., contamination or hardness of the water), purge and clean the unit in shorter intervals. Proceed as follows: 1. Use a suitable cleaning agent to purge the unit against the direction of flow. 2. Clean the heat exchanger in compliance with the work instruction provided by the manufacturers of the cleaning agents. 3. If required, clean the upstream filters (e.g., dirt trap). 4. Use fresh water to rinse the heat exchanger before re-installation. Comply with these instructions when using cleaning agents: Select the appropriate cleaning agent according to the type of contamination to be removed. Ensure the compatibility of the heat exchanger with each cleaning agent. 7 Removal Proceed as follows: 1. Shut off the primary side. 2. Shut off the secondary side. 3. Wait until the water in the heat exchanger has cooled down. 4. Disconnect the pipe connections of the heat exchanger to the facility system. 5. Drain the heat exchanger. 6. If required, remove the heat exchanger from the facility system vicinity. The heat exchanger has been removed. Reflex Longtherm 09-2016 English 13

Annex 8 Annex 8.1 Reflex Customer Service Central customer service Switchboard: Telephone number: +49 (0)2382 7069-0 Customer Service extension: +49 (0)2382 7069-9505 Fax: +49 (0)2382 7069-523 E-mail: service@reflex.de Technical hotline For questions about our products Telephone number: +49 (0)2382 7069-9546 Monday to Friday, 8:00 a.m. 4:30 p.m. 8.2 Inspection The Pressure Equipment Directive 97/23/EC is applicable. Comply with the applicable national regulations regarding recurring inspections. 8.3 Warranty The respective statutory warranty regulations apply. 8.4 Glossary Bio-fouling Cavitation Re-evaporation Bacterial contamination of heat-transmitting system components due to material content in the used water. Formation and dissolution of vapour-filled cavities (vapour bubbles) in fluids. Water steam from hot and pressurised water caused at a vacuum. 14 English Reflex Longtherm 09-2016

8.5 Conformity and standards Annex Declaration of conformity for assemblies Design, manufacture, and testing of pressure equipment Applied assessment of conformity procedure according to the Pressure Equipment Directive 2014/68/EU of the European Parliament and the Council of 15 May 2014 Soldered plate heat exchangers: reflex longtherm Universal use in heating, solar, drinking water and cooling water systems Tank information r... c... /... according to nameplate Operating limits according to nameplate Charging material according to installation, operating and maintenance manual Standards and set of rules Pressure Equipment Directive 2014/68/EU, ASME VIII Pressure equipment according to Directive 2014/68/EU Art. 4 Fluid group 1 (according to DGRL, Art. 13) Conformity assessment method to module B + D Labelling according to Directive 2014/68/EU CE 0090 Certificate No. of the EU design type examination: Notified body for the EU design type examination (Module B) and evaluation of the QA system (Module D) 0662/169/03 rhc 15/ 0662/043/02 rhc 40/ 0662/044/02 rhc 60/ 0662/045/02 rhc 85/ 0662/046/02 rhc 150/ 0662/059/02 rhc 200/ 0662/060/02 rhc 300/ TÜV Thüringen e. V. Melchendorfer Straße 64, 99096 Erfurt, Germany Register No. of the notified body 0090 The signatories are authorised to collate the technical documentation and undertakes to provide this documentation in a suitable format, if required by the competent authority. Manufacturer Reflex Winkelmann GmbH Gersteinstraße 19 D - 59227 Ahlen - Germany Telephone: +49 (0)2382 7069-0 Fax: +49 (0)2382 7069-588 E-mail: info@reflex.de The manufacturer hereby confirms that the design, manufacture and testing of this pressure equipment meets the requirements of Directive 2014/68/EU / ASME VIII. Norbert Hülsmann Volker Mauel Members of the Board of Directors Reflex Longtherm 09-2016 English 15

SI1581en / 9126260 / 02-16 Reflex Winkelmann GmbH Gersteinstraße 19 59227 Ahlen, Germany Telephone: +49 (0)2382 7069-0 Fax: +49 (0)2382 7069-588 www.reflex.de