TABLE OF CONTENTS EKHWS

Similar documents
EEDEN technical data EKSOLHWAV1

TABLE OF CONTENTS EKHTS-A

General Outline: Altherma

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWS150B3V3 EKHWS200B3V3 EKHWS300B3V3 EKHWS200B3Z2 EKHWS300B3Z2

INSTALLATION MANUAL. Domestic hot water tank with option kit for air to water heat pump system EKHWSU150B3V3 EKHWSU200B3V3 EKHWSU300B3V3 EKUHWB

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3

TABLE OF CONTENTS ERSQ-AAY1

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

EEDEN technical data. Altherma TM

EEDEN technical data ERHQ AA. Altherma. Altherma

Service Manual ESIE Altherma. - Outdoor unit - ERHQ011~016AAV3* - ERHQ011~016AAW1*

EEDEN technical data ERHQ AA

EEDEN technical data EKRTR. Altherma. Altherma

DESIGN MANUAL Version 1.0

INSTALLATION AND OPERATION MANUAL

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

TABLE OF CONTENTS ERHQ BAV3

TABLE OF CONTENTS EDLQ AA6V3

TABLE OF CONTENTS EBLQ01-016AA6V3

TABLE OF CONTENTS RMXS-E8V1B

Split Type System. Air to Water Heat Pump

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

DACA-EEDEN technical data. Engineering Data. DaikinAltherma

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

WH-TD20B3E5 WH-TD30B3E5

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

Heating. Technical Data EEDEN ERRQ-AY1

Air Conditioning Technical Data RZASG-MV1

technical data air conditioning systems RZQ B8W1B Split Sky Air

The natural fit, all-in-one. Daikin Altherma monobloc heat pump for the installer

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

Air Conditioning Technical Data RZAG-MV1

EHS. EHS (Mono, LT, 50Hz)

This presentation is posted for public use. ACEEE does not endorse any product or service.

High temperature hydrobox for VRV

Heating. Catalogue. Climate comfort. All seasons. Heating. Air conditioning. Applied Systems. Refrigeration. Heating - Domestic hot water - Cooling

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

Heating. Daikin Altherma Flex Type. Catalogue ALL SEASONS PERFECT C MFORT. Centralised 3-in-1 heating solution with the scope for individuality

Daikin Altherma Selection Report

Service Manual. Air Cooled Refrigeration Condensing Unit

UNVENTED WATER HEATERS. Water Heater Display Stand

INSTALLATION MANUAL. System air conditioner RXYQ8P7Y1K RXYQ10P7Y1K RXYQ12P7Y1K RXYQ8P7YLK RXYQ10P7YLK RXYQ12P7YLK

INSTALLATION MANUAL. Domestic hot water tank for air to water heat pump system EKHTS200A EKHTS260A EKHTSP200AA EKHTSP260AA

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

Installation & Technical Guide. Domestic & Commercial.

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Air Conditioners. Technical Data FBQ-C

Air Conditioning Technical Data AZAS-MY1

technical data air conditioning systems Indoor Units FBQ-C7VEB

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Frequently Asked Questions. A 3 in 1 Renewable Energy Solution For Home Heating, Cooling and Domestic Hot Water

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

Public. Altherma by Daikin. Altherma Commissioning Service Field Settings

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

Digital Inverter 4 series 8 & 10HP

INSTALLATION MANUAL. Domestic hot water tank with UK kit for air to water heat pump system EKHTS200AC EKHTS260AC EKHTSU200AC EKHTSU260AC EKUHWHTA

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

A +++ R32 Daikin Altherma 3 powered by Bluevolution. Why choose Daikin Altherma 3? 65 C

technical data air conditioning systems RZQ C7Y1B Split Sky Air

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

Air Conditioning. Technical Data. VRV IV heat recovery EEDEN14-200_4 REYQ-T

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

Sanitary Water Tank INSTALLATION & SVC MANUAL

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

Exceeding the Standard

The world s most advanced direct electric water cylinder

Exceeding the Standard

EDUS D Engineering Data RXYQ-TAYCU, 575 V. Heat Pump 60 Hz

Experienced. Flexible. Reliable. Approachable. Genuine

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

Powerflow Unvented water heater

Broag Pressurisation equipment

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

S-Therm Air to Water Heat Pumps

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

Daikin Altherma 3. Product catalogue Setting the new heat pump standard

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

your comfort. our world. Altherma Flex Type Renewable heat pump system for every environment

Heating. Pricelist Heating PERFECT C MFORT. Catalogue. All seasons PERFECT C MFORT. Heating. Air Conditioning. Applied Systems.

DESIGN & TECHNICAL MANUAL

Central Home Heating and Hot Water Supply

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

Transcription:

Domestic hot water tank DOMESTIC HOT WATER TANK EKHWS TABLE OF CONTENTS EKHWS 1 Features............................................................ 68 2 Specifications...................................................... 69 Technical Specifications............................................ 69 Electrical Specifications............................................ 69 Capacity tables.................................................... 70 Heating capacity tables............................................. 70 4 Dimensional drawing & centre of gravity....................... 71 Dimensional drawing................................................ 71 5 Piping diagram..................................................... 72 6 Wiring diagram..................................................... 7 Wiring diagram...................................................... 7 7 Operation range................................................... 74 Altherma Domestic hot water tank 67

Domestic hot water tank DOMESTIC HOT WATER TANK EKHWS 1 Altherma Domestic hot water tank 68 1 Features D o m e s t i c h o A l t h e r m a E K H W S D o m e s t i c h o

2 Specifications Domestic hot water tank DOMESTIC HOT WATER TANK EKHWS EKHWS150A V EKHWS200A V EKHWS00A V EKHWS200A Z2 EKHWS00A Z2 EKHWSU150 AV EKHWSU200 AV EKHWSU00 AV 2-1 TECHNICAL SPECIFICATIONS Casing Colour Neutral white Material Epoxy-coated mild steel Dimensions Packing Height mm 950 1,200 1,650 1,200 1,650 1,040 1,280 1,75 Width mm 600 600 600 600 600 600 600 600 Depth mm 600 600 600 600 600 600 600 600 Unit Height mm 900 1,150 1,600 1,150 1,600 1,015 1,265 1,715 Width mm 580 580 580 580 580 580 580 580 Depth mm 580 580 580 580 580 580 580 580 Weight Unit kg 7 45 59 45 59 8 46 60 Packed Unit kg 40 49 64 49 64 41 50 65 Packing Material EPS Carton Weight kg 4 5 4 5 4 5 Main components Tank Water volume l 150 200 00 200 00 150 200 285 Material Stainless steel (DIN 1.4521) Max. temperature C 85 85 85 85 85 85 85 85 Max. water pressure bar 10 10 10 10 10 10 10 10 Tank Insulation Material Polyurethane foam Min. thickness mm 40 40 40 40 40 40 40 40 Main components Temperature sensor Piping connections Heat Quantity 1 1 1 1 1 1 1 1 exchanger Material Duplex steel LDX 2101 Booster heater Quantity 1 1 1 1 1 1 1 1 Capacity kw Cable length m 12 12 12 12 12 12 12 12 Water inlet H/E Diameter inch /4 FBSP Water outlet H/E Diameter inch /4 FBSP Cold water in Diameter inch /4 FBSP Hot water out Diameter inch /4 FBSP 1 2 EKHWS150A V EKHWS200A V EKHWS00A V EKHWS200A Z2 EKHWS00A Z2 EKHWSU150 AV EKHWSU200 AV EKHWSU00 AV 2-2 ELECTRICAL SPECIFICATIONS Unit Power Supply Phase 1~ 1~ 1~ 2~ 2~ 1~ 1~ 1~ Frequency Hz 50 50 50 50 50 50 50 50 Voltage V 20 20 20 400 400 20 20 20 Nominal running current A 1 1 1 7.5 7.5 1 1 1 Fuse Size A 20 20 20 20 20 20 20 20 Phase 1~ 1~ 1~ 2~ 2~ 1~ 1~ 1~ S Altherma Domestic hot water tank 69

Capacity tables - 1 Heating capacity tables Domestic hot water tank DOMESTIC HOT WATER TANK EKHWS The ALTHERMA by Daikin heat-pump in combination with the optional domestic hot water tank provide hot water for household usage. The below mentioned date allow a proper selection of the domestic hot water tank size for maximum comfort and efficiency. (1) Sanitary hot water volume: The volume of hot water available for domestic sanitary usage depends on the physical volume of the sanitary tank, on the sanitary water setpoint temperature and on the temperature spreading in the tank. Therefor we define the equivalent hot water volume (EHWV). Definition: EHWV = the volume of hot water available for domestic sanitary usage at a temperature of 40 C. 40 C is considered a comfortable sanitary hot water temperature. Tank Setpoint temp. Usage pattern EHWV (l) ( C) Modest Medium High 55 110 - - - 150L 65 150 + - - 75 175 ++ + - 55 160 + - - 200L 65 200 ++ + - 75 240 ++ ++ - 55 295 ++ ++ - 00L 65 85 ++ ++ + 75 45 ++ ++ ++ Grade ++ Excessive availability of sanitary hot water. + Sufficient availability of sanitary hot water. - Temporary shortage of sanitary hot water can occur. Usage pattern Modest Daily demand up tp 220 l -> typcial 2-persons usage pattern. Medium Daily demand up to 25 l -> typical to 4 persons usage pattern. High Daily demand up to 550 l -> 4 to 6 persons usage pattern. (2) Heat-up time: Definition: Heat-up time The time required to reheat the domestic hot water tank to 55 C after tapping a certain volume of hot water at 40 C. note: changing the field settings (see installation manual) can influence the heat-up time. Tank Setpoint temp. Heat-up time for 150 L (bath) Heat-up time for 50 L (shower) ( C) <min> <min> 150L 55 60 45 200L 55 60 40 00L 55 50 0 Conditions for testing: Ta = 7 CDB / 6 CWB, Troom = 20 C, Tstart = 10 C, outdoor unit type: ERYQ007 () Efficiency of sanitary hot water production: In the ALTHERMA by Daikin system both the heat-pump and the electric booster heater supply the energy to produce sanitary hot water. The higher the portion of energy supplied by the heat-pump, the more energy efficient the system is. Lowering the setpoint temperature increases the portion of energy supplied by the heat-pump and thus the efficiency of the system. Definition: Heat-pump portion Percentage of energy supplied by the heat-pump in the total energy need for sanitary hot water. Heat-pump portion Setpoint temp. ( C) Conditions: Real life condition Simulation of a daily usage based upon medium usage pattern. Outdoor temperature 7 CDB / 6 CWB Room temperature 20 CDB Outdoor unit type ERYQ007 Tank type 200l Field settings Default field settings (see installation manual). 4TW5789-1 70 Altherma Domestic hot water tank

Domestic hot water tank DOMESTIC HOT WATER TANK EKHWS 4 Dimensional drawing & centre of gravity 4-1 Dimensional drawing EKHWS j1 Water mains in female /4 BSP j2 Water mains out female /4 BSP j Thermistor connection j4 Flow (from EKHB(H/X)*) female /4 BSP j5 Return (to EKHB(H/X)*) female /4 BSP j6 j7 Thermal protector j8 Anode j9 Cable entry power, booster heater and thermal protection cable j10 Re-circulation connection female /4 BSP j11 Cable entry from EKHB(H/X)* (see EKSOLHWAV1) j12 Cable entry (to EKSOLHWAV1) j1 Thermistor connection (See EKSOLHWAV1) 1 Required service space around the tank 4 TW5784-1 EKHWSU Water connections j1 Water IN (cold) 22MM j2 Water OUT (hot) /4 female BSP j Flow from EKHB(H/X)* /4 female BSP j4 Return to EKHB(H/X)* /4 female BSP j5 Temperature relief valve 15MM j6 Thermistor connection j7 Thermistor connection (SeeEKSOLHWAV1) 1/2 female BSP j8 Re-circulation hole /4 female BSP Water connections kit j9 Pressure reducing valve 22MM-22MM j10 Expansion relief valve 22MM-22MM j11 T-piece (to tundish) 15MM-15MM-1/2 female BSP j12 Tundish 22MM-15MM j1 T-piece (to expansion vessel) 22MM-22MM-22MM j14 Adapter (expansion vessel) 22MM-/4 female BSP j15 Expansion vessel female BSP j16 Drain valve 22MM-/4 hale BSP j17 Solenoid valve /4 female BSP-/4 hale BSP Other j18 j19 j20 j21 j22 j2 j24 j25 j26 Thermal protector 1+Thermostat Cable entry power, booster heater, therminal protector Cable entry power solenoid valve Cable entry solenoid valve Blind stop + 2 plastic screw-on closing caps for pressure reducing valve Thermal protector 2+Thermostat Cable entry (to EKSOLHWAV1) Cable entry from EKHB(H/X)* (see EKSOLHWAV1) Required service space Model H1 H2 H H4 EKHWSU150AV 900 1015 255 10 EKHWSU200AV 1150 1265 410 200 EKHWSU00AV 1600 1715 410 200 TW5784-2 Altherma Domestic hot water tank 71

5 Piping diagram Domestic hot water tank DOMESTIC HOT WATER TANK EKHWS EKHWSU Field installation (delivered with indoor unit) Field supply -way motorized valve Outdoor Indoor Shut off valve Load Shut off valve Water return Water flow Option domestic hot water tank 5 Water return Water flow Water main OUT Option domestic hot water tank Water main IN Expansion relief valve Pressure reducing valve with integrated non return valve line strainer T-piece 2-way solenoid valve Tundish Expansion vessel *Field installation delivered with EKUHWA kit Drain valve T-piece RST Y1S MS Domestic hot water thermistor Solenoid valve -way motorized valve TW5785-1 Check valve Flare connection Screw connection Flange connection Pinched pipe Spinned pipe 72 Altherma Domestic hot water tank

Domestic hot water tank DOMESTIC HOT WATER TANK EKHWS 6 Wiring diagram 6-1 Wiring diagram EKHWSU 1 EKHB/X* E4H F2B F2U KM L N Q2T Q2L QL X2M X4M X5M1 X7M Y1S : Booster heater : Fuse booster heater : Fuse 5A/250V : Contactor booster heater : Line : Neutral : Thermostat Domestic hot water tank : Thermostat protector domestic hot water tank Thermal protector Booster heater : Terminal block : Terminal block : Solenoid valve 6 EKHWSU**0AV Water tank Switch box Notes: 1 This wiring diagram applies to the EKHWSU option 2 : Field wiring : Field wiring : Wire colour : Terminal strip : Protective earth BLK=Black RED=Red BLU=Blue WHT=White PNK=Pink YLW=Yellow BRN=Brown GRY=Grey GNR=Green ORG=Orange VIO=Violet 4 Please refer to the EKHWSU**DAV option manual for more installation details. TW5786-1 Altherma Domestic hot water tank 7

7 Operation range Domestic hot water tank DOMESTIC HOT WATER TANK EKHWS EKHW DOMESTIC HOT MODE outdoor temp ( CDB) 7 water temperature sanitary tank ( C) BOOSTER HEATER OPERATION ONLY 4TW5775-1A 74 Altherma Domestic hot water tank

Solar Kit SOLAR KIT EKSOLHWAV1 TABLE OF CONTENTS EKSOLHWAV1 1 Features............................................................ 76 2 Specifications...................................................... 77 Technical Specifications............................................ 77 Electrical Specifications............................................ 77 Dimensional drawing & centre of gravity....................... 78 Dimensional drawing................................................ 78 4 Piping diagram..................................................... 80 5 Wiring diagram..................................................... 81 Wiring diagram...................................................... 81 Altherma Solar Kit 75

Solar Kit SOLAR KIT EKSOLHWAV1 1 Altherma Solar Kit 76 1 Features S o l a r K i t A l t h e r m a E K S O L H W A V 1 S o l a r K i t

2 Specifications Solar Kit SOLAR KIT EKSOLHWAV1 2-1 TECHNICAL SPECIFICATIONS EKSOLHWAV1 Dimensions Packing Height mm 795 Width mm 40 Depth mm 295 Unit Height mm 770 Width mm 05 Depth mm 270 Weight Unit kg 8 Packed Unit kg 9 Packing Material Carton Weight kg 1 Heat Type Brazed plate Exchanger Pressure drop Solar side kpa 21.5 Maximum inlet Solar side C 110 temperature Capacity W 1,400 Logarithmic mean temperature difference (LMTD) K 5 Pump Type water cooled Number of speeds Power input W 46 Sound Sound Pressure dba 27 Water circuit Piping connections diameter inch /4" FBSP Insulation material EPP Ambient Maximum C 5 temperature Minimum C 1 2 2-2 ELECTRICAL SPECIFICATIONS EKSOLHWAV1 Unit Power Supply Phase 1~ Frequency Hz 50 Voltage V 220-240 Voltage range Minimum -10% Maximum +10% Power Supply Intake indoor unit Altherma Solar Kit 77

Solar Kit SOLAR KIT EKSOLHWAV1 Dimensional drawing & centre of gravity - 1 Dimensional drawing EKSOLHWAV1 + EKHWS150* EKSOLHWAV1 + EKHWS200-00* Detail 1 Detail 1 Components j1 Pump + switch for speed setting j2 Heat exchanger j EPP casing j4 Non return valves domestic hot water tank j11 Cable entry (Altherma indoor unit) j12 Cable entry (Pump cable) Accessories (delivered with EKSOLHWAV1) Connection type j1 Thermistor sockel (thermistor solar pump station) (internal diameter 6.1mm) j14 Adapter /4 M BSP-/4 MBSP j15 Adapter /4 F BSP-/4 M BSP j16 Adapter /4 M BSP-/4 MBSP CONNECTIONS j5 Inlet connection from solar pump station /4 F BSP j6 Return connection to solar pump station /4 F BSP j7 Inlet connection from Altherma indoor unit /4 F BSP j8 Return connection to Altherma indoor uint /4 F BSP j9 EKSOLHWAV1 return connection to the domestic hot water tank heatexchanger /4 F BSP j9a 200-00l Tank j9b 150l Tank j10 EKSOLHWAV1 inlet connection from the domestic hot water tank heatexchanger /4 F BSP Minimum space for service & ventilation Service space Scale: 1/20 Detail 1 Scale: 1/4 TW57844-1 78 Altherma Solar Kit

Solar Kit SOLAR KIT EKSOLHWAV1 Dimensional drawing & centre of gravity - 1 Dimensional drawing EKSOLHWAV1 + EKHWS150* EKSOLHWAV1 + EKHWS200-00* Detail 2 Scale: 1/4 Detail 2 Detail 1 Components j1 Pump + switch for speed setting j2 Heat exchanger j EPP casing j4 Non return valves domestic hot water tank j11 Cable entry (Altherma indoor unit) j12 Cable entry (Pump cable) Accessories (delivered with EKSOLHWAV1) Connection type j1 Thermistor sockel (thermistor solar pump station) (internal diameter 6.1mm) j14 Adapter /4 M BSP-/4 M BSP j15 Adapter (Field supply) /4 F BSP-/4 M BSP CONNECTIONS EKUHWA Kit j5 Inlet connection from solar pump station /4 F BSP j16 Solenoid valve /4 F BSP-/4 F BSP j6 Return connection to solar pump station /4 F BSP j17 Adapter /4 M BSP-/4 M BSP j7 Inlet connection from Altherma indoor unit /4 F BSP Solenoid valve j8 Return connection to Altherma indoor uint /4 F BSP j9 EKSOLHWAV1 return connection to the domestic hot water tank heatexchanger /4 F BSP j9a 200-00lTank j9b 150lTank j10 EKSOLHWAV1 inlet connection from the domestic hot water tank heatexchanger /4 F BSP Minimum space for service & ventilation Model H1 EKHWSU150* 40 EKHWSU200* 400 EKHWSU00* 400 Service space Scale: 1/20 TW57844-2 Altherma Solar Kit 79

4 Piping diagram Solar Kit SOLAR KIT EKSOLHWAV1 EKSOLHWAV1 Field installation (delivered with indoor unit) Field supply -way motorized valve Overview Y1S MS Solenoid valve -way motorized valve Outdoor Indoor Shut off valve Load 4 Field supply Solar collector Shut off valve Field supply Solar pump station Water from indoor Medium from solar collector Medium to solar collector Water to indoor Option solar kit Water to tank Water from tank Option domestic hot water tank Detail 1 Only for EKHWSU* * Delivered with EKUHWA kit Water from indoor Detail 1 Water to tank 2-way solenoid valve * Medium from solar collector Plate heat exchanger For EKHW(S/E)* Medium to solar collector Non return valve Pump Water to indoor Non return valve Check valve Flare connection Screw connection Flange connection Pinched pipe Spinned pipe Water from tank TW57845-1 80 Altherma Solar Kit

Solar Kit SOLAR KIT EKSOLHWAV1 5 Wiring diagram 5-1 Wiring diagram EKSOLHWAV1 with EKHWS*V EKHWS*V EKHB/X* Solar pump 5 E4H : Booster heater F2B : Fuse booster heater F2U : Fuse 5A/250V KM : Contactor booster heater L : Line N : Neutral Q2T : Thermostat protector 1 domestic hot water tank Q2L : Thermal protector QL : Thermal protector 2 Booster heater QT : Thermostat protector 2 domestic hot water tank X2M X4M : Terminal block X5M1 X7M : Terminal block Y1S : Solenoid valve EKHB/X* Notes: 1 : Field wiring : Field wiring : Wire colour : Terminal strip : Protective earth 2 BLK=Black RED=Red BLU=Blue WHT=White PNK=Pink YLW=Yellow BRN=Brown GRY=Grey GNR=Green ORG=Orange VIO=Violet For more installation details please refer to the relevant installation manual. TW57846-1 EKSOLHWAV1 with EKHWS*Z2 EKHWS*Z2 EKHB/X* Solar pump E4H : Booster heater F2B : Fuse booster heater F2U : Fuse 5A/250V KM : Contactor booster heater L : Line N : Neutral Q2T : Thermostat protector 1 domestic hot water tank Q2L : Thermal protector QL : Thermal protector 2 Booster heater QT : Thermostat protector 2 domestic hot water tank X2M X4M : Terminal block X5M1 X7M : Terminal block Y1S : Solenoid valve EKHB/X* Notes: 1 : Field wiring : Field wiring : Wire colour : Terminal strip : Protective earth 2 BLK=Black RED=Red BLU=Blue WHT=White PNK=Pink YLW=Yellow BRN=Brown GRY=Grey GNR=Green ORG=Orange VIO=Violet For more installation details please refer to the relevant installation manual. TW57846-1 Altherma Solar Kit 81

5 Wiring diagram 5-1 Wiring diagram EKSOLHWAV1 with EKHWSU Solar Kit SOLAR KIT EKSOLHWAV1 EKHWS*V EKUHWA EKHB/X* 5 Notes: 1 : Field wiring : Field wiring : Wire colour : Terminal strip : Protective earth 2 BLK=Black RED=Red BLU=Blue WHT=White PNK=Pink YLW=Yellow BRN=Brown GRY=Grey GNR=Green ORG=Orange VIO=Violet For more installation details please refer to the relevant installation manual. EKSOLHWAV1 EKHB/X* E4H : Booster heater F2B : Fuse booster heater F2U : Fuse 5A/250V KM : Contactor booster heater L : Line N : Neutral Q2T : Thermostat protector 1 domestic hot water tank Q2L : Thermal protector QL : Thermal protector 2 Booster heater QT : Thermostat protector 2 domestic hot water tank X2M X4M : Terminal block X5M1 X7M : Terminal block Y1S : Solenoid valve TW57846-1 82 Altherma Solar Kit