AFRL-RB-WP-TR

Similar documents
HALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM]

Vision Protection From Lasers Overview for Dr. Beagley, Australia

Converting Existing Copper Wire Firing System to a Fiber-Optically Controlled Firing System for Electromagnetic Pulsed Power Experiments

MINIMUM PERFORMANCE REQUIREMENT FOR AIR FORCE FLIGHTLINE FIRE EXTINGUISHERS:

EXTINGUISHMENT AND BURNBACK TESTING OF FIRE FIGHTING AGENTS

REPORT DOCUMENTATION PAGE

EVALUATION OF FIKE CORPORATION S EXPLOSION SUPPRESSION SYSTEM FOR ULTRA-HIGH SPEED FIRE SUPPRESSION APPLICATIONS

The Conservation Fund The Center for Conservation and Development

Low Impact Development at Naval Facilities: Opportunities and Constraints

FIRE PROTECTION FOR. Dist A. MILITARY GROUND VEHICLES. Steve McCormick US Army RDECOM-TARDEC.

Direct measurement of the aerosol absorption and extinction cross section for a variety of chemical and biological simulants in the LWIR

Industrial Workshop Gettysburg, PA February 26, 2004

A Novel Approach for a Hostile Arms Fire Sensor

DURIP: Fast Oscilloscope and Detectors for Air Laser Research

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

Force Protection Joint Experiment (FPJE) Battlefield Anti-Intrusion System (BAIS) Sensors Data Analysis and Filtering Metrics

ECBC SBIR/STTR Projects. ECBC SBIR/STTR MSCoE STRF Conference

Recent Advances in Mercuric Iodide Detector Fabrication and Instrument Development*

Design Considerations for Abrasive Blast Rooms & Recovery Systems

Sustainability Criteria for Planning, Constructing, and Operating Contingency Bases

FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY ABSTRACT

lighting control systems Division - Name - Date - Language 1

EEENE. AD-AIII 4"- AIR FORCE OCCUPATIONAL AND ENVIRONMENTAL HEAL.TH LAS --ETC F/S 13/11 r

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

MEMORANDUM FOR U.S. Army Developmental Test Command (TEDT-DTC-TMAIC. Pritts), 314 Longs Comer Road, Aberdeen Proving Ground, MD

Sensor Grand Challenges: An NVESD Perspective

HANTAVIRUS PREVENTION: CLEANUP OF RODENT CONTAMINATION

BRITE II Characterization and Application to a New Advanced Flight Motion Simulator

REPORT DOCUMENTATION PAGE

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

AFRL-RX-TY-TR

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

REPORT DOCUMENTATION PAGE

How Wicks and Orientation

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Distribution Restriction Statement

How Computer Simulation Helps to Design Induction Heating Systems

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Thermal Performance of a Loop Thermosyphon

IMPLEMENTATION OF A NOVEL STRUCTURAL HEALTH MANAGEMENT SYSTEM FOR STEEL BRIDGES

EIA STANDARD TP-38B EIA B. Cable Pull-Out Test Procedure for Electrical Connectors. EIA/ECA B (Revision of EIA A)

Certification Report of the ST3000 Pressure Transmitter

COOLING ENERGY SAVING SYSTEM USING A WATER MIST DEVICE ON WINDOWS

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

Operation of a Two-Phase Reverse Loop Thermosyphon

Form DOT F (8-72) Technical Report Documentation Page 2. Government Accession No. 3. Recipient's Catalog No.

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

High Temperature Water Heat Pipes for Kilopower System

Wildland fire phenomenology experiments:

Low GWP Refrigerants for Air Conditioning Applications

Certification Report of the ST 3000 Pressure Transmitter with HART 6

TESTS OF ADSIL COATING

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

TWO-PHASE MICRO-CHANNEL HEAT SINK FOR SPACE CRAFT THERMAL CONTROL

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

(12) United States Patent (10) Patent No.: US 6,361,301 B1

Performance of non-cfc refrigerator driven by chilled water from 35 kw LiBr/H2O solar absorption cooling system

(12) United States Patent

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

Optimization of Thin Film Heater/Sensor Design for Miniature Devices Using Finite Element Analysis

AFRL-ML-TY-TR

ANALYSIS OF LGWP ALTERNATIVES FOR SMALL REFRIGERATION (PLUGIN) APPLICATIONS

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

Tom Miesner Principal Pipeline Knowledge & Development

IC Chapter Severe Weather Warning Sirens

Variable far infrared radiation (VFIR) technique for cubic carrot drying

Experimentation of Heat Pipe Used In Nano-Fluids

Failure Modes, Effects and Diagnostic Analysis

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Minco SmartHeat SLT Self-Limiting Thin-Film Heater Technology

Experimental study on mass transfer comparison of two liquid desiccants aqueous solutions

SCIENCE CHINA Technological Sciences

High Temperature Water-Titanium Heat Pipes for Spacecraft Fission Power

Standard Operating Procedure Ottawa Fire Services. Fire Safety Plan Approval - Revised

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

THE ROLE OF SUCTION IN THE PERFORMANCE OF CLAY FILL RONALD F. REED, P.E. 1 KUNDAN K. PANDEY, P.E. 2

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Standard method for measuring and using the temperature coefficient of resistance to determine the temperature of a metallization line

TSP-6: Solar Water Heater

POWER Selecting Shell Side Design Temperature for Feedwater Heaters

Efficiency of Non-Azeotropic Refrigerant Cycle

Investigation of the Potential Use of Blue Light in Forward Scattering Optical Smoke Chambers to Detect all UL217 Fires in the New Standard

THE A.A.B. COMPANY 615 McCallie Avenue Chattanooga, TN

Air-Cooled Thermosyphon for Press-Pack Stack of Semiconductors

VISUAL STUDY ON TWO-PHASE FLOW IN A HORIZONTAL CLOSED-LOOP OSCILLATING HEAT PIPE , Thailand , Thailand

Development of a Transient Simulation Model of a Freezer Part II: Comparison of Experimental Data with Model

Development of a Compensation Chamber for Use in a Multiple Condenser Loop Heat Pipe

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Modeling water-mist based suppression of 34 GJ car-deck fires using FDS

Hot Water System Performance Testing at PG&E s Applied Technology Services: Mimicking a Full-Service Restaurant in the Laboratory

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

p?:uam SYSTEMS Technical Progress Report Jane H. Davidson NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING February 1,1996 to March 31,1996

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

Hot-air distribution in the floor heating

VARIABLE REFRIGERANT FLOW FOR LODGING

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

Transcription:

AFRL-RB-WP-TR-2012-0191 NOVEL HEAT TRANSFER DEVICE RESEARCH Ryan E. Mikus Advanced Structural Concepts Branch Structures Division Kenneth D. Kihm University of Tennessee APRIL 2012 Interim Report See additional restrictions described on inside pages STINFO COPY AIR FORCE RESEARCH LABORATORY AIR VEHICLES DIRECTORATE WRIGHT-PATTERSON AIR FORCE BASE, OH 45433-7542 AIR FORCE MATERIEL COMMAND UNITED STATES AIR FORCE

NOTICE AND SIGNATURE PAGE Using Government drawings, specifications, or other data included in this document for any purpose other than Government procurement does not in any way obligate the U.S. Government. The fact that the Government formulated or supplied the drawings, specifications, or other data does not license the holder or any other person or corporation; or convey any rights or permission to manufacture, use, or sell any patented invention that may relate to them. This report was cleared for public release by the USAF 88 th Air Base Wing (88 ABW) Public Affairs Office (PAO) and is available to the general public, including foreign nationals. Copies may be obtained from the Defense Technical Information Center (DTIC) (http://www.dtic.mil). AFRL-RB-WP-TR-2012-0191 HAS BEEN REVIEWED AND IS APPROVED FOR PUBLICATION IN ACCORDANCE WITH THE ASSIGNED DISTRIBUTION STATEMENT. *//Signature// RYAN E. MIKUS, 1st Lt, USAF Research Engineer Advanced Structural Concepts Branch Structures Division //Signature// ANDREW D. SWANSON, Chief Advanced Structural Concepts Branch Structures Division This report is published in the interest of scientific and technical information exchange, and its publication does not constitute the Government s approval or disapproval of its ideas or findings. *Disseminated copies will show //Signature// stamped or typed above the signature blocks.

REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202-4302. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YY) 2. REPORT TYPE 3. DATES COVERED (From - To) April 2012 Interim 01 June 2010 01 April 2012 4. TITLE AND SUBTITLE NOVEL HEAT TRANSFER DEVICE RESEARCH 6. AUTHOR(S) Ryan E. Mikus (AFRL/RBSA) Kenneth D. Kihm (University of Tennessee) 5a. CONTRACT NUMBER In-house 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 62201F 5d. PROJECT NUMBER 2401 5e. TASK NUMBER 5f. WORK UNIT NUMBER A03I03 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION Advanced Structural Concepts Branch (AFRL/RBSA) Structures Division Air Force Research Laboratory, Air Vehicles Directorate Wright-Patterson Air Force Base, OH 45433-7542 Air Force Materiel Command, United States Air Force 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) Air Force Research Laboratory Air Vehicles Directorate Wright-Patterson Air Force Base, OH 45433-7542 Air Force Materiel Command United States Air Force 12. DISTRIBUTION/AVAILABILITY STATEMENT University of Tennessee 13. SUPPLEMENTARY NOTES PAO Case Number: 88ABW-2012-3265; Clearance Date: 07 Jun 2012. Report contains color. REPORT NUMBER AFRL-RB-WP-TR-2012-0191 10. SPONSORING/MONITORING AGENCY ACRONYM(S) AFRL/RBSA 11. SPONSORING/MONITORING AGENCY REPORT NUMBER(S) AFRL-RB-WP-TR-2012-0191 14. ABSTRACT Qu Tubes or Advanced Thermal Transport Devices (ATTD s) use a new heat transfer principal and are believed to be superior to standard heat pipes. Inventor claims that the ATTD s are entirely dry on the inside and consist of three thin layers of material and a powder. Other claims state that the ATTD s act independently of gravity, exhibit very high conductivity, work over large distances and temperature ranges, and operate at a lower pressure than traditional heat pipes. The Air Vehicles Directorate of Air Force Research Laboratory purchased Qu tubes and equipment to thoroughly examine the operation limits of such a device in a highly controlled environment. 15. SUBJECT TERMS Qu tube, heat pipe, thermosyphon, advanced thermal transport device, solid state heat pipe 16. SECURITY CLASSIFICATION OF: 17. LIMITATION a. REPORT Unclassified b. ABSTRACT Unclassified c. THIS PAGE Unclassified OF ABSTRACT: SAR 18. NUMBER OF PAGES 20 19a. NAME OF RESPONSIBLE PERSON (Monitor) Ryan E. Mikus 19b. TELEPHONE NUMBER (Include Area Code) N/A Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39-18

TABLE OF CONTENTS SECTION PAGE 1.0 RESEARCH OBJECTIVE... 1 2.0 PROPOSED TASKS... 2 3.0 SUMMARY OF ACHIEVEMENT... 3 3.1 X-Ray Verification of the Existence of Working Fluids Inside the Qu Tubes... 3 3.2 IR Thermography Comparison of the Qu Tube with the Wicked Heat Pipe... 4 3.3 Quantitative Characterization of both Qu Tube and Heat Pipe Operations... 7 4.0 FUTURE DIRECTIONS... 11 i

LIST OF FIGURES FIGURE PAGE Figure 1: X-Ray Images of Aluminum Qu Tubes... 3 Figure 2: X-Ray Images of Copper Heat Pipes.... 4 Figure 3: IR Images Of the Qu Tube (The Left Column in Each Image) and the Wicked Heat Pipe (The Right Column in Each Image) Simultaneously Heated By a Single Heat Gun. 6 Figure 4: Schematic of the Experimental Set Up... 8 Figure 5: The Experimental Set Up To Adjust the Orientation of the Test Article... 9 Figure 6: Cincinnati Sub-Zero (CSZ) Chamber for Controlling Test Environment... 9 Figure 7: Front-End Interface of the Labview VI Data Acquisition Program... 10 LIST OF TABLES TABLE PAGE Table 1: Experimental Matrix for Infra-Red (IR) Imaging... 5 Table 2: Heater Insert Properties... 8 Table 3: Test Matrix... 11 ii

1.0 RESEARCH OBJECTIVE The main objective for this research is to validate the claims and performance of the Novel Heat Transfer Device (Qu Tubes) against conventional wicked and un-wicked heat pipes with water as the working solution. 1

2.0 PROPOSED TASKS I. Verification of the claim that there is no working fluid inside the Qu Tubes using high-resolution x-ray imaging. II. III. Qualitative characterization of the Qu Tube operations in comparison with a wicked water heat pipe using the IR thermography. Quantitative characterization of both Qu Tubes and water heat pipes using a sophisticated data acquisition system to verify the comparative performance of the two devices. 2

3.0 SUMMARY OF ACHIEVEMENT 3.1 X-Ray Verification of the Existence of Working Fluids Inside the Qu Tubes The test articles include aluminum Qu Tubes of 5/8-inch and ½-inch diameters, manufactured by Posnett Corp., and copper wicked heat pipes of 5/8-inch and ½-inch diameters, manufactured by Thermacore Inc. All of the test articles are 3 ft in length. The high-resolution X-ray imaging facility at the Air Force Research Laboratory (AFRL) Materials & Manufacturing Directorate at Wright-Patterson Air Force Base reviewed the existence of a working fluid inside the Qu Tubes. Despite the inventor s claim that the Qu Tubes are entirely dry on the inside, Fig. 1 clearly identifies the existence of a working fluid for all of our tested Qu Tubes. It is hypothesized that Qu Tubes are dependent on gravity. Therefore, it will be essential to examine various orientations of the Qu Tubes in evaluating their performance. The heights of the fluid meniscus range from 3.1 to 3.2 measured from the bottom end. Figure 2 shows the water coolant contained inside the wicked as well as non-wicked copper heat pipes. The heights of the water meniscus range from 3.5 to 4.0 measured from the bottom end. 5/8-inch diameter 1/2-inch diameter Figure 1: X-Ray Images of Aluminum Qu Tubes 3

Wicked Water Heat Pipes Non-wicked Water Heat Pipes Figure 2: X-Ray Images of Copper Heat Pipes 3.2 IR Thermography Comparison of the Qu Tube with the Wicked Heat Pipe In order to achieve a qualitative understanding of the operations of both Qu Tubes and water heat pipes, a total of twenty (20) IR video files were recorded. The detailed test conditions for these IR recordings are summarized in Table 1. Heating was provided by a heat gun, which expelled hot air to either the bottom of the evaporator ( bottom ) or the approximate meniscus area ( meniscus ). The average meniscus locations were 3.12 inches from the bottom for the Qu-tube, 3.75 in. for the HP-wicking, and 3.33 inches for the HP-no wicking. Figure 3 shows representative IR images extracted from the case identified in red-font in Table 1, which simultaneously imaged both the Qu Tube (left) and the wicked heat pipe (right) in nearly horizontal orientation (5-degree) under heating near the approximate meniscus areas. 4

With the heater on, at t = 45 sec (Fig. 3-A), the temperature near the meniscus area of the Qu Tube rises more rapidly than the rest, while the wicked heat pipe develops a more uniform temperature rise. It is believed that this distinction is attributed to the fact that the Qu Tube has no wick inside. For the tube surface area above the meniscus, the aluminum Qu Tube develops relatively higher temperature and seemingly steeper temperature gradients, in comparison with those of the copper heat pipe. This implies that the effective thermal conductivity of the Qu Tube may be lower than that of the heat pipe if we assume identical cooling heat transfer rate for both, which is proportional to the effective thermal conductivity multiplied by the temperature gradient along the tube surface. Similar observations prevail as time progresses showing the steeper temperature gradient and higher maximum temperature for the Qu Tube while more uniform and gradual temperature increases are observed for the heat pipe (Fig. 3-B). When the temperature non-uniformity of the Qu Tube exceeds a certain limit (the left inset image of Fig. 3-C), the first very sudden surging of the working fluid is triggered and the inside is seemingly flooded with the fluid resulting in the uniform temperature distributions at least for a short period of time (the right inset image of Fig. 3-C). The surging continues repeatedly, but with progressively shorter intervals with reduced strength (Fig. 3-D). In contrast, the heat pipe raises the surface temperature gradually and uniformly ensuring far more stable operation. Table 1: Experimental Matrix for Infra-Red (IR) Imaging Dimension: 0.5 φ x 36 L Qu-tube Qu-tube HP-wicking HP-no wicking V-bottom V-meniscus H-bottom H-meniscus HP-wicking V-bottom V-meniscus H-meniscus H-meniscus (4 fps) NH-meniscus (4 fps) V-bottom V-meniscus H-bottom H-meniscus HP-no wicking V-bottom V-meniscus H-meniscus (4 fps) NH-meniscus (4 fps) V-meniscus V-bottom V-meniscus V: Vertical orientation H: Horizontal orientation 5

Qu Tube Wicked H 2 O Heat Pipe Heat Gun (A) t = 45 sec (B) t = 90 sec (C) t = 210/211 sec (D) t = 290/291 sec Figure 3: IR Images Of the Qu Tube (The Left Column in Each Image) and the Wicked Heat Pipe (The Right Column in Each Image) Simultaneously Heated By a Single Heat Gun 6

In summary, based on comprehensive observations of all the recorded image files, the Qu Tube responds more rapidly to heat input during start-up while the water heat pipe provides slow but more stable operation. In addition, the Qu Tube appears somewhat less effective in conduction heat transfer than the wicked water heat pipe. However, considering that the present experimental conditions, such as heating and cooling, were not rigorously controlled, a more concrete conclusion is deferred until a quantitative study under a controlled environment is completed. The detailed heat flux and temperature profiles for all of the selected test articles will be accurately measured. 3.3 Quantitative Characterization of both Qu Tube and Heat Pipe Operations The experimental setup for quantitative characterization of the test articles has been designed, fabricated, and installed in-house at the Facility for Innovative Research in Structures Technology (FIRST) (Fig. 4). The test stand enables accurate setting of the predetermined orientation of the test articles (Fig. 5). The entire set up, including the heat pipe, the heater shoe with 24 electrical heater elements, and the cooling jacket of coiled copper tubing, is wrapped in insulation and placed inside the Cincinnati Sub-Zero (CSZ) environment control unit, which will be held at the heat sink coolant temperature (Fig. 6). A data acquisition (DAQ) system has been developed to control the power to the heating elements and to monitor the temperature data from seventeen thermocouple probes of which, twelve probes are placed along the adiabatic region of the heat pipe, one placed at each end of the heat pipe, two measuring the inlet/outlet temperatures of the condenser flow path and the last one measuring the chamber temperature. The condenser coolant flow rate is detected by a digital flow meter and also monitored by the DAQ system (Fig. 7). A number of necessary refinements and preparations have been conducted to facilitate quantitative characterization of the test articles. Three major tasks have been completed: 1. In order to meet the stringent requirements for temperature measurement accuracy, all of the industry-standard thermocouple probes (±1.0ºC measurement uncertainties) have been calibrated by elaborate laboratory processes to ensure ±0.1ºC uncertainties. 2. Erroneous detection of the coolant flow rate was identified and then corrected by inputting the correct flow meter calibration numbers for the LabView VI DAQ program. 3. Noise in the thermocouple probe readings was found to be caused by cross-talk between the heater power electrical current and the thermocouple probe voltages when they are mounted on the test article surfaces that are interfaced with the copper heater shoes via a pair of stainless steel inserts. The stainless inserts have been replaced by MACOR, a glass ceramic material with extremely high electrical resistance yet with acceptable thermal conductance as shown in Table 2 below. 7

Table 2: Heater Insert Properties Heater Insert Material Thermal Conductivity (25ºC) Electrical Resistivity Stainless Steel 16 W/m K 7.2 x 10-3 Ohms/m MACOR 1.4 W/m K > 10 19 Ohms/m Figure 4: Schematic of the Experimental Set Up 8

Heater Shoe Heaters Test Article Cooling Coil Figure 5: The Experimental Set Up To Adjust the Orientation of the Test Article Figure 6: Cincinnati Sub-Zero (CSZ) Chamber for Controlling Test Environment 9

Figure 7: Front-End Interface of the Labview VI Data Acquisition Program 10

4.0 FUTURE DIRECTIONS Upon completion of the aforementioned refinements and preparations of the DAQ system, a series of comparative studies between the Qu Tubes and the wicked heat pipes will be performed to validate the claims and performance of the Qu Tubes. The test matrix for planned experimental conditions is presented in Table 3. Further, X-ray imaging will be conducted of the evaporator end of a Qu Tube in an inverted orientation (evaporator end above the condenser end) to prove or disprove the existence of a solid working solution inside. In addition, destructive characterization of tested Qu Tubes will determine their chemical composition. Table 3: Test Matrix Test Articles 5/8 diameter: Qu Tube vs. wicked heat pipe vs. non-wicked heat pipe ½ diameter: Qu Tube vs. wicked heat pipe vs. non-wicked heat pipe Orientation (degrees from horizontal) 5 1-5 Heater Power Input P min = 20 Watts P min = 20 Watts P min = 20 Watts (P) P max at dryout P max at dryout P max at dryout ( P = 10 Watts) ( P = 10 Watts) ( P = 10 Watts) Coolant Chamber Temperature ( C) 10 50 10 50 10 50 11