Education Title Solutions

Similar documents
Office Title Solutions

Healthcare Title Solutions

Hospitality Title Solutions

Restaurants IECC 2015 Solutions

Restaurants ASHRAE Solutions

Code Review TITLE PRESENTED BY POURIA NIKNAM

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

Here we see the list of auto shutoff controls we will cover in the next few slides

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

24 Volt DC Edition EMerge Alliance Registered Products

INSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

California Title Design Guide for Smart Lighting Control and Energy Solutions

TITLE 24 ICONOGRAPHY. Iconography System

CRESTRON GREEN LIGHT ARCHITECTURAL DIMMING CONTROLS (GLPD)

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

ANSI/ASHRAE/IES

Wireless Lighting Control Made Easy

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

SECTION LIGHTING CONTROLS

LIGHTING CONTROLS

ANSI/ASHRAE/IES

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

Code Compliance Commercial Application Guide

Indoor Controls. SpaceWise SWZG2. Wireless technology

ASHRAE October 18, 2013

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Crestron Zūm. Wireless lighting control made easy

WSA120: New Energy Codes and Lighting Controls

CRESTRON MEDIAMANAGER INTELLICLASS

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

C-Bus Application Note. Function Rooms and Ballrooms. Overview

LIGHTING CONTROLS. Smart Enough to Work Right Out of the Box

A. This Section includes the following lighting control devices:

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

Mini Product Guide.

CHV-TSTAT-FCU Heating and Cooling Fan-Coil Thermostat. Supplemental Guide Crestron Electronics, Inc.

Aesthetic, energyefficient. control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS

Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors

visual environment technologies etcconnect.com

Applied Lighting Controls

IN2 Lighting Control Devices

Application Guide to CA Title 24

2015 IECC. Design Guide for Smart Lighting Control and Energy Solutions

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

Hubbell Controls Application Guide to ASHRAE 90.1 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING CONTROL

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

C-Bus Application Note. Standard Meeting Room. Overview

Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

Sensors and Detectors

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 26 ELECTRICAL

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

A Guide for Applicants and Lighting Designers

Product Specifications Dialog Room Controller* (*patent pending)

Reduce lighting energy costs with controls

ARCHITECTURAL DIMMING PANEL - MAIN/SECONDARY

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

Wireless Plug Load Control

A. This Section includes the following lighting control devices:

SECTION LIGHTING CONTROL DEVICES

Product Comparison Guide

Ever evolving energy code requirements and the large demand for energy

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

CLS-EXP-DIM. Functional Summary. Specifications

Reference Design. classrooms. Eckerd College, Florida

1. Section [ Lighting Control Panel Boards:] Lighting panels (switching) controlled by ControlKeeper

H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared

miniz Quick Start Guide

Hubbell Controls Application Guide to CA Title 24 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING CONTROL

CA TITLE 24 QUICK SOLUTIONS GUIDE FOR

LIGHTING CONTROL DEVICES

VESICA LINEAR SUSPENDED VES L

0ACDT2000MV Ultasonic/Infared Occ Sensor

IECC. nlight Applications Guide.

visual environment technologies etcconnect.com

Waste not, want not. As part of our efforts to ensure we practice sustainability in our business, we ve printed this brochure on recycled paper.

GE LightSweep Lighting Control System Guideform Specification

Douglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) LTG-1-A

Note: A summary of the applicable code sections is shown in the CEC _Table100A.

C ontrolsystems Themostadv ingenious a n cedsensor-basedcontrols.now integratedintoourmostpopularfixtures.

Distributed Low-Voltage Power System. design and application guide

Lighting Summary - Interior

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

The Power To Supply... All Your Electrical Products

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Design and Commissioning of Lighting Control Systems. Rick Miller, PE, LC, LEED AP RNM Engineering, Inc. October 18, 2012

Lighting Controls: The Next Big Thing in Lighting. June 18th, 2014

Stellar Panelboard Dimming Systems

Lighting Control Solutions for Parking Facilities

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Transcription:

Education Solutions Design Guide Crestron Electronics, Inc.

Contents About 1 Design Guide Information 1 Code Standards 2 Classroom 4 Zūm... 4 GLPP... 5 Higher Education Classroom 6 Zūm... 6 GLPAC... 7 Private Office 8 Zūm... 8 GLPP... 9 Corridor 10 Zūm... 10 GLPP... 11 Public Restroom 12 Zūm... 12 GLPP...13 Cafetorium 14 GLPAC + DMX...14 i crestron.com Doc. 8293A

About is a residential and commercial building energy code that is designed to reduce energy consumption. The goal of this code is to reduce energy consumption by providing design and construction requirements for lighting controls. Lighting controls such as occupancy status sensors, multi-level controls, and demand response provisions allow you to synchronize indoor light levels with daylight levels in accordance with. Design Guide Information Crestron offers this Design Guide for Education - solutions to use as a reference for typical layouts. Use it as guidance to make code compliance quick and easy. The Crestron team is also available to support with detailed design, submittal, and installation requirements. For additional information, please contact your Crestron representative at CLCDesign@crestron.com or (888) 330-1502. Doc. 8293A crestron.com 1

Code Standards Summary ON/OFF CONTROLS LIGHT LEVEL CONTROL Code Provision Minimum Requirement Code Standards Code Description 130.1(a) 1 control. Each space and area enclosed by ceiling-height partitions Luminaires must be controlled with accessible manual on/off local must be independently controlled. 130.1(b) 130.1(c) 2 130.1(c)5/6/7 Sensor Lighting of any enclosed area 100 square feet or larger with more than one luminaire and a load >0.5 watts per square foot should provide multi-level lighting control that meets uniformity requirements in accordance with Title24 Table 130.1-A. Lighting control can not override local on/off or any other control requirements. Lighting must be controlled by either 1) an occupant sensing control, 2) automatic time-switch control with 2 hour maximum override and holiday scheduling, or 3) other control capable of automatically shutting off lighting. Indoor shut-off zones must be separated using ceiling high partitions and can be no larger than one floor with a maximum of 5,000 sq. ft. Occupant Sensing s are required to shut off all lighting. Full or partial off to at least 50% via occupant sensing controls is required. 130.1(d) Daylight Zones 3 in all daylit zones as defined by 130.1(d). Lighting controls should have multilevel functionality to at least the number of control steps Automatic daylighting controls should be installed and configured defined in Title 24 Table 130.1-A. 130.1(e) Demand Response Ready 4 Buildings >10,000 square feet with a lighting power density 0.5 watts per square foot are required to receive a standards-based messaging protocol, which automatically reduces lighting power by at least 15% and remains consistent with uniform illumination requirements defined in Title 24 Table 130.1-A. PLUG LOAD CONTROL 130.5(d) led Receptacles 50% of receptacles are required to automatically turn off based on occupancy or after a vacancy of 20 minutes or less. Each uncontrolled receptacle must have at least one controlled receptacle within 6 feet. Primary Solutions Zūm Wireless Light GLPP GLPAC 1. General lighting must be separately controlled from all other lighting systems in an area. Floor and wall display, window display, case display, track, ornamental, and special effects lighting should be separately controlled and placed on circuits that are 20 amps or less. 2. Countdown timer switches should not be used to comply with the automatic shut-off control requirements in Section 130.1(c)1, except in single-stall bathrooms and closets that are <70 square feet where the lights must shut off within ten minutes, or in a server aisle/room where the lights must shut off within 30 minutes. 3. The photosensor should be readily accessible to authorized personnel for calibration adjustments. To prevent unauthorized access, the photosensor may be mounted inside a case that is secured with a locking mechanism. 4. Add a networked Crestron control system for demand response (130.5(d)) control. For networked Zūm applications, add a ZUM-FLOOR-HUB and ZUMNET-GATEWAY for demand response. 2 crestron.com Doc. 8293A

Small Private Office 250 sq. ft. Space Type Public Restroom Corridor Classroom Cafeteria & Gym Doc. 8293A crestron.com 3

Classroom Zūm Whiteboard Sensor (130.1(c)5/6/7) Daylight Zones (130.1(d)) Demand Response Ready Zūm Net Wireless Zūm Mesh Wireless Classrooms with a connected general lighting load of 0.7 watts per square feet should have at least one control step between 30-70 percent of full rated power. Symbol Qty. Product Description 3 ZUMMESH-JBOX-5A-LV Junction Box Zone ler, 0-10V Dimming, 5A 1 ZUMMESH-NETBRIDGE Zūm Network Bridge 2 ZUMMESH-KP10CBATT 6-Button Battery-Powered Keypad 2 ZUMMESH-PIR-VACANCY-BATT PIR Vacancy Sensor (AUTO-OFF) 1 ZUMMESH-OL-PHOTOCELL-BATT Open-Loop Daylight Sensor 4 crestron.com Doc. 8293A

Classroom GLPP Whiteboard Sensor (130.1(c)5/6/7) Daylight Zones (130.1(d)) Demand Response Ready 18/4 18/2 Classrooms with a connected general lighting load of 0.7 watts per square feet should have at least one control step between 30-70 percent of full rated power. Product Qty. Product Description 1 GLPP-1DIMFLV3-CN-PM 3-Ch 0-10V Dimmer with Cresnet 2 GLPPA-KP In-Wall Keypad for GLPP 1 GLS-ODT-C-NS Dual-Technology Ceiling Mount Occupancy Sensor 1 GLS-LOL Crestron Green Light Photosensor, Open-Loop Doc. 8293A crestron.com 5

Higher Education Classroom Zūm Whiteboard RS-232 to AV System Sensor (130.1(c)5/6/7) Daylight Zones (130.1(d)) Demand Response Ready Zūm Mesh Wireless Zūm Net Wireless UL924 emergency lighting devices are available for life safety. Classrooms with a connected general lighting load of 0.7 watts per square feet should have at least one control step between 30-70 percent of full rated power. Symbol Qty. Product Description 4 ZUMMESH-JBOX-5A-LV Junction box Zone ler, 0-10V Dimming, 5A 1 ZUMMESH-NETBRIDGE Zūm Network Bridge 1 ZUMMESH-AVBRIDGE AV Bridge Wireless Integration Module 3 ZUMMESH-KP10CBATT 6-Button Battery-Powered Keypad 1 ZUMMESH-OL-PHOTOCELL Open Loop Daylight Sensor 3 ZUMMESH-PIR-VACANCY-BATT Zum Wireless Battery-Powered Vacancy Sensor, Auto-Off, 500 Sq. Ft. 6 crestron.com Doc. 8293A

Higher Education Classroom GLPAC Whiteboard RS-232 to AV System Sensor (130.1(c)5/6/7) Daylight Zones (130.1(d)) Demand Response Ready Cresnet 18/3 UL924 emergency lighting devices are available for life safety. Classrooms with a connected general lighting load of 0.7 watts per square feet should have at least one control step between 30-70 percent of full rated power. Symbol Qty. Product Description 1 GLPAC-DIMFLV4 Green Light Integrated Lighting System, 4-Channel 3 C2N-CBD-P Cameo Keypad, Standard Mount 1 C2N-IO Port Expansion Module 1 GLS-LOL Crestron Green Light Photosensor, Open-Loop 2 GLS-ODT-C-NS Dual-Technology Ceiling Mount Occupancy Sensor, 2000 sq. ft. Doc. 8293A crestron.com 7

Private Office Zūm Sensor (130.1(c)5/6/7) Demand Response Ready led Receptacle (130.5(d)) Zūm Net Wireless Zūm Mesh Wireless Daylight zones (130.1(d)) may be required if windows are present. Symbol Qty. Product Description 1 ZUMMESH-5A-LV Zūm Wall-Box Dimmer, 5A 1 ZUMMESH-JBOX-20A-PLUG Zūm J-Box Load ler, Plug Load Switch 1 ZUMMESH-NETBRIDGE Zūm Network Bridge 1 ZUMMESH-PIR-VACANCY-BATT PIR Vacancy Sensor (AUTO-OFF) 8 crestron.com Doc. 8293A

Private Office GLPP Sensor (130.1(c)5/6/7) Demand Response Ready led Receptacle (130.5(d)) 18/4 18/2 Daylight zones (130.1(d)) may be required if windows are present. Symbol Qty. Product Description 1 GLPP-DIMFLVCN-PM 1-Ch 0-10V Dimmer with Cresnet 1 GLPP-SWCN Crestron Green Light Power Pack, 1-Channel Switch with Cresnet 1 GLPPA-KP In-Wall Keypad for GLPP 1 GLS-ODT-C-NS Dual-Technology Ceiling Mount Occupancy Sensor, 2000 sq. ft. Doc. 8293A crestron.com 9

Corridor Zūm Sensor (130.1(c)5/6/7) Demand Response Ready Zūm Net Wireless Zūm Mesh Wireless 18/3 UL924 emergency lighting devices are available for life safety. Daylight zones (130.1(d)) may be required if windows are present. Lighting installed in a corridor should meet the following requirements in addition to complying with Section 130.1(c)1: The corridor must be controlled with occupant sensing controls that automatically reduce lighting power in unoccupied areas by at least 50 percent. The occupant sensing controls should be capable of automatically turning the lighting fully on only in the separately controlled corridor, and should be automatically activated from all designed paths of egress. Lighting installed in a common area corridor that provides access to guest rooms and dwelling units should comply with 130.1(c)7: Common area corridors must be controlled with occupant sensing controls that automatically reduce lighting power in unoccupied areas by at least 50 percent. The occupant sensing controls should be capable of automatically turning the lighting fully on only in the separately controlled corridor, and should be automatically activated from all designed paths of egress. When the installed lighting power is 80 percent or less of the value allowed under the Area Category Method, occupant sensing controls should reduce the power by at least 40 percent. Symbol Qty. Product Description 1 ZUMMESH-JBOX-5A-LV Junction Box Zone ler, 0-10V Dimming, 5A 1 ZUMMESH-JBOX-SIM Zūm Junction Box Sensor Integration Module 1 ZUMMESH-NETBRIDGE Zūm Network Bridge 1 ZUMMESH-KP10ABATT Rocker-Button Battery Powered Keypad 1 GLA-US-HALLWAY-COM1-24 40 khz Ultrasonic Presence Detector, Ceiling Mount, Hallway Coverage, 18-24 VAC/VDC 10 crestron.com Doc. 8293A

Corridor GLPP Sensor (130.1(c)5/6/7) Demand Response Ready 18/3 18/2 UL924 emergency lighting devices are available for life safety. Daylight zones (130.1(d)) may be required if windows are present. Lighting installed in a corridor should meet the following requirements in addition to complying with Section 130.1(c)1: The corridor should be controlled by occupant sensing controls that separately reduce the lighting power by at least 50 percent when the corridor is unoccupied. The occupant sensing controls should be capable of automatically turning the lighting fully on only in the separately controlled corridor, and should be automatically activated from all designed paths of egress. Lighting installed in a common area corridor that provides access to guest rooms and dwelling units should comply with 130.1(c)7: Common area corridors must be controlled with occupant sensing controls that automatically reduce lighting power in unoccupied areas by at least 50 percent. The occupant sensing controls should be capable of automatically turning the lighting fully on only in the separately controlled corridor, and should be automatically activated from all designed paths of egress. When the installed lighting power is 80 percent or less of the value allowed under the Area Category Method, occupant sensing controls should reduce the power by at least 40 percent. Product Qty. Product Description 1 GLPP-1DIMFLVCN-PM 1-Ch 0-10V Dimmer with Cresnet 1 GLPPA-KP In-Wall Keypad for GLPP 1 GLA-US-HALLWAY-COM1-24 40 khz Ultrasonic Presence Detector, Ceiling Mount, Hallway Coverage, 18-24 VAC/VDC Doc. 8293A crestron.com 11

Public Restroom Zūm Demand Response Ready led Receptacle (130.5(d)) Zūm Mesh Wireless Zūm Net Wireless 18/3 Public restrooms with two or more stalls may use a manual control not accessible to unauthorized personnel. Daylight zones (130.1(d)) may be required if windows are present. Public restrooms should have at least one control step between 30-70 percent of full rated power. Symbol Qty. Product Description 2 ZUMMESH-JBOX-5A-LV Junction Box Zone ler, 0-10V Dimming, 5A 1 ZUMMESH-JBOX-SIM Zūm Junction Box Sensor Integration Module 1 ZUMMESH-NETBRIDGE Zūm Network Bridge 1 ZUMMESH-KP10ABATT Rocker-Switch Battery Powered Keypad 2 GLS-ODT-C-NS Dual-Technology Ceiling Mount Occupancy Sensor 12 crestron.com Doc. 8293A

Public Restroom GLPP Demand Response Ready led Receptacle (130.5(d)) 18/4 18/2 Public restrooms with two or more stalls may use a manual control not accessible to unauthorized personnel. Daylight zones (130.1(d)) may be required if windows are present. Public restrooms should have at least one control step between 30-70 percent of full rated power. Product Qty. Product Description 1 GLPP-1DIMFLV2CN-PM 2-Ch 0-10V Dimmer with Cresnet 1 GLPPA-KP In-Wall Keypad for GLPP 2 GLS-ODT-C-NS Dual-Technology Ceiling Mount Occupancy Sensor Doc. 8293A crestron.com 13

Cafetorium GLPAC + DMX Demand Response Ready Cresnet DMX Ethernet Daylight zones (130.1(d)) may be required if windows are present. Symbol Qty. Product Description 1 C2N-CBD-P Cameo Keypad, Standard Mount 1 TSW-760 7 Touch Screen SpaceBuilder System Components: 1 GLPAC-DIMFLV8 Green Light Integrated Lighting System, 8-Channel 1 DIN-EN-2x18 Enclosure for DIN Rail Devices, 2 DIN Rails, 18 Units Wide 1 DIN-AP3 DIN Rail 3-Series Automation Processor 1 DIN-DMX-1UNIVERSE DIN, CONTROLLER, DMX, 1 Universe 1 CEN-SW-POE-5 5-Port PoE Switch 14 crestron.com Doc. 8293A

Notes Doc. 8293A crestron.com 15

Notes 16 crestron.com Doc. 8293A

Crestron, the Crestron logo, 3-Series, Cresnet, Crestron Green Light, Cameo, Zūm are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. This document was written by the Technical Publications department at Crestron Electronics, Inc. 2018 Crestron Electronics, Inc. Doc. 8293A crestron.com 17

Crestron Electronics, Inc. 15 Volvo Drive, Rockleigh, NJ 07647 Tel: 888.CRESTRON Fax: 201.767.7576 www.crestron.com Design Guide Doc 8293A (2051449) 10.18 Specifications subject to change without notice