Self-Priming* Portable Multi-Use Pump

Similar documents
CWS Series. Operating Instructions and Parts Manual PERFORMANCE SPECIFICATIONS CONSTRUCTION. * Refer to Page 13 for Jet Assembly Part Numbers

Operating Instructions and Parts Manual MOTOR HOUSING MOTOR SHAFT IMPELLER VOLUTE PUMP DISCHARGE PERFORMANCE. Model Discharge Head Max Flow

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Shallow Well Jet Pump Water Systems

Installation Instructions

200i User s information manual

Installation Instructions

Installation Instructions If you have questions, call or visit our website at:

LS Condensate Removal Pump Installation, Operation and Service Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Alpine CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER

USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER.

PUREFIRE GAS BOILERS USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER

Operating Instruction Manual

INSTALLATION INSTRUCTIONS

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Installation Instructions

APEX CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER

CAUTION CAUTION WARNING. Vulcan RT Heater With Remote Temperature Controller

Operating Instruction Manual

O w n e r s M a n u a l

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

Vulcan Fire Module WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

AGA TOTAL CONTROL. Model No. - TC3

CHUGGER PUMP Chugger Max Models

Air Pump Up to 800 gallons

FES - Series Portable Electric Heaters

Operating Instruction Manual

Installation & Operation Manual. AromaFlo. mr.steam. Feel Good Inc.

GE Monogram. Installation Instructions. Built-In Dishwashers. with Optional Trim Kit. Models ZBD5600 ZBD5700 ZBD5900

Instruction Manual. Counter Showcase Models HNC-120BA-L/R-SL HNC-150BA-L/R-SL HNC-180BA-L/R-SL HNC-210BA-L/R-SL. hoshizakiamerica.

INSTRUCTION BOOK FOR. Professional Electrol

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

QUICK PRIME INSTALLATION AND SERVICE MANUAL

USER'S INFORMATION MANUAL SERIES 2 GAS - FIRED

INSTALLATION INSTRUCTION In-Ground Color Changing

SG-DEH-PEX Vertical Dehumidifier Pump Operating Instructions

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

QUICK PRIME INSTALLATION AND SERVICE MANUAL

OWNER S MANUAL. Important: Read carefully before assembly and use. PORTABLE CANISTER U #961A00007 ID111867

Operating Instruction Manual

Installation, Operation and Maintenance Manual

ICE MAKER. 26 Lbs. Capacity HME010019N. Before using your Ice Maker, please read this manual.

WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

INSTRUCTION BOOK FOR. Senior Electrol

Illuminated Stopper Station Push Button

SM-909/SM /2" Sweat 3/4" Sweat 3 3/8" F.L. Max. Max. Line Weight Model No. HP Inlet/Outlet Volts Amps Fluid Temp. Pressure (Lbs.

USER'S INFORMATION MANUAL ES2 GAS - FIRED

Air Conditioner

Outdoor Refrigerator USER S MANUAL

SOLA SM II Light Engine Instruction Manual

Installation, Operation and Maintenance Manual

Installation Instructions If you have questions, call or visit our website at:

Installation Instructions If you have questions, call or visit our website at:

INSTALLATION INSTRUCTION In-Ground

OWNER S MANUAL INSTALLATION, OPERATION, & PARTS SAVE THIS INSTRUCTION MANUAL

Installation Instructions

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

Owner s Manual Phoenix CAM Pro

Operation & Care Instructions Save For Future Reference ABOUT THE MACHINE

USER'S INFORMATION MANUAL SERIES 2 GAS - FIRED

WARNING WARNING WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

7 1/4" 3 3/8" Pump Max. Max. Line Weight Model No. HP Housing Inlet/Outlet Fluid Temp. Pressure (Lbs.)

Instruction Sheet. ECM High-Efficiency Circulator. SUPERSEDES: January 24, 2016 EFFECTIVE: March 29, 2016

OWNERS GUIDE TO INSTALLATION AND OPERATION

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

- Do not store or use gasoline or other

Installation, Operation and Maintenance Manual

1495D. Installation and Operation Manual, 230 Voltage 2/16/2017

Owner s Manual Phoenix Stackable CAM Pro

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

Plastic Housing Plastic Housing Stainless Housing SM /8" 3 3/8"

Operating Instruction Manual

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Location Requirements

Pressurized Filter Up to 1250 gallons

An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. WARNING

WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

Floating Pond Pump System 1/2, 3/4 & 1 HP 230V Models FPS05021, FPS07021, FPS10021

Installation, Operation and Maintenance Manual

K Series (Model A) Fan Forced Wall Heaters

Lumination TM Volumetric Retrofit Kit

DELTA HEAT SIDE BURNER

Straight Suction Canister. Owner s Manual

OWNERS MANUAL MODEL: Portable Snow Cone Machine PART NUMBER: 120 volts, 60 hz WARNING ELECTRICAL SHOCK HAZARD.

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

20 High velocity Air

Upright Freezer Congélateur vertical Congelador vertical

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Aquatron 4, 8, /95 Form Number Instructions For Use. Advance Models , , , ,

O w n e r s M a n u a l

OWNERS MANUAL MODEL: Portable Snow Cone Machine PART NUMBER: 120 volts, 60 hz WARNING ELECTRICAL SHOCK HAZARD.

SolidFlo G2 Solid Handling Pumps Product Manual

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

Transcription:

Self-Priming* Portable Multi-Use Pump Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. 50TK SPECIFICATIONS POWER SUPPLY REQUIREMENTS 120 V, 60 Hz MOTOR Brush Type HORSEPOWER 1/2 HP CIRCUIT REQUIREMENT 15 A (minimum) LIQUID TEMPERATURE RANGE 40 F- 120 F MOTOR HOUSING MOTOR SHAFT IMPELLER VOLUTE PUMP SUCTION PUMP DISCHARGE CONSTRUCTION Cast Iron Stainless Steel Thermoplastic Cast Iron 3/4 in. Brass Hose Fittings 3/4 in. Brass Hose Fittings PERFORMANCE Model HP Discharge Head 10 ft. 20 ft. 40 ft. 60 ft. 80 ft. 50TK 1/2 Gal/hr 1600 1500 1240 950 660 2018, BLue Angel/Scott Fetzer Company www.blueangelpumps.com 620003-026 B 08/18

DESCRIPTION This *self-priming portable Multi-Use pump is designed to be used as a transfer pump for such applications as emptying water heaters, livestock tanks, etc. The motor is air cooled; it is not designed to operate under water. This pump is not suitable for drinking water. NOTE: This pump is not intended for permanent installation or long, extended periods of continuous operation. *Self-Priming if used with a foot valve on suction hose or if gravity fed. UNPACKING After unpacking the Multi-Use pump, carefully inspect for any damage that may have occurred during transit. Check for loose, missing or damaged parts. If you need assistance, call our Customer Support Department at 1-888-636-6628. SAFETY SIGNAL WORDS This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols. GENERAL SAFETY INFORMATION CALIFORNIA PROPOSITION 65 This product can expose you to chemicals, including DEHP, which is known to the State of California to cause cancer, birth defects and reproductive harm. For more information, go to www.p65warnings.ca.gov. AVERTISSEMENT Ce produit peutvous exposer à des produits chimiques, notamment du DOP, reconnus par l État de Californie comme étant cancérigènes et à l origine d anomalies congénitales et de problèmes de l appareil reproductif. Pour plus de renseignements, visiter le site www.p65warnings.ca.gov. Danger indicates an imminently hazardous situation which, if NOT avoided, WILL result in death or serious injury. La mention Danger indique une situation dangereuse imminente qui, si elle n est pas évitée, ENTRAÎNE la mort ou des blessures graves. Warning indicates a potentially hazardous situation which, if NOT avoided, COULD result in death or serious injury. La mention avertissement indique une situation potentiellement dangereuse qui, si elle n est pas évitée, risque d entraîner des lésions corporelles graves ou même la mort. Caution indicates a potentially hazardous situation which, if NOT avoided, MAY result in minor or moderate injury. MISE EN GARDE La mention mise en garde indique une situation potentiellement dangereuse qui, si elle n est pas évitée, pourrait entraîner des blessures mineures ou modérées. Notice indicates important information, that if NOT followed, MAY cause damage to equipment. This is the safety alert symbol. It is used to alert you to potential bodily injury hazards. Obey all safety messages that follow this symbol to avoid possible harm. Do not submerge motor or allow motor to be exposed to water. Personal injury and/or death WILL result, and void warranty. Ne pas submerger le moteur ni laisser le moteur exposé à l'eau. Des blessures corporelles et/ou la mort pourraient en découler. Do NOT use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do NOT use in explosive atmospheres. Pump only clear water. Failure to follow this warning WILL result in personal injury and/or property damage. NE PAS utiliser pour pomper des fluides inflammables ou explosifs tels que l'essence, le mazout, le kérosène, etc. NE PAS utiliser dans des atmosphères explosives. Pomper uniquement de l'eau claire. Le nonrespect de cet avertissement entraînera des blessures corporelles et/ou des dégâts matériels. Risk of Electrical Shock! All wiring SHOULD be performed by a licensed or certified electrician. Risque de choc électrique! Tout le câblage DOIT être effectué par un électricien qualifié ou certifié. NOTE: Information that requires special attention. REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. 2

50TK GENERAL SAFETY INFORMATION (CONT T) INSTALLATION Do NOT walk on wet areas until ALL power is turned off. Failure to follow this warning WILL result in fatal electrical shock. Ne PAS marcher sur les zones humides jusqu'à ce que le courant est coupé. Le défaut de suivre cet avertissement entraînera une décharge électrique mortelle. 1. Read all instructions before operation. 2. Disconnect power and release all pressure within the system before servicing any component. 3. Drain all liquids from system before servicing. Secure the discharge line before starting the pump. An unsecured discharge line MAY whip. Personal injury and/or property damage COULD result. Fixer la conduite de décharge avant le démarrage de la pompe. Toute conduite de décharge non fixée pourrait donner fouetter. Des blessures corporelles et/ou des dégâts matériels pourraient en résulter. 4. Before each use inspect pump and system components, checking for weak and/or worn hoses. Insure all connections are secure. Pump motor is equipped with an automatic resetting thermal protector and MAY restart unexpectedly. Protector tripping is an indication of motor overheating because of operating pump at low heads (low discharge restriction), excessively high or low voltage, inadequate wiring, excessive surrounding air temperature, inadequate ventilation, and/or defective motor or pump. Le moteur de la pompe est doté d'un protecteur thermique à réinitialisation automatique et POURRAIT redémarrer de manière imprévue. Le déclenchement du protecteur est une indication de surchauffe du moteur à cause d'une utilisation de la pompe à faible hauteur de chute (restriction de faible décharge), d'une tension excessivement haute ou basse, d'un câblage inadéquat, d'un branchement incorrect du moteur, d'une température ambiante excessive, d'une ventilation inadéquate ou d'une pompe ou d'un moteur défectueux. 5. Provide a means of pressure relief in the case of an obstructed discharge line. 6. Protect electrical cord from sharp objects, hot surfaces, oil and chemicals. Do not operate with damaged or kinked cord. ALWAYS disconnect power source before attempting to operate, service, or maintain the pump. NEVER handle a pump with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock WILL occur. TOUJOURS débrancher le cordon d'alimentation avant d'essayer d'installer, de réparer ou de faire l'entretien de la pompe. Ne JAMAIS manipuler de pompe avec les mains humides ou debout sur une surface humide ou mouillée, ou dans l'eau. RISQUE de choc électrique mortel! 1. A ground fault circuit interrupter (GFCI) is required. Risk of electrical shock! This pump is supplied with a grounding conductor and grounding type attachment plug. A grounded receptacle in conformance with current NEC and local codes must be used. Risque de choc électrique! Cette pompe est fournie avec un conducteur de mise à la terre et une fiche de terre. Utiliser une prise de courant mise à la terre conforme au CNE et aux codes locaux en vigueur. 2. This pump operates on 115V. 3. Use an extension cord only if necessary. Contact Customer Support (888-636-6628) for guidance. Risk of fatal electrical shock. NEVER cut off the round grounding prong. Cutting the cord or plug WILL void the warranty and make the pump inoperable. Risque de choc électrique mortel. Ne JAMAIS couper la broche de terre ronde sur le cordon. Couper le cordon ou les bornes de la batterie ANNULERA la garantie et rendra la pompe inutilisable. 4. Figure 1 shows a typical installation. Threaded adapters are furnished for attaching garden hose where conditions permit its use. In no case should the pump be more than 15 feet above or away from water source. Install a foot valve to keep it selfpriming. 5. The inlet line may be galvanized pipe, plastic pipe, or reinforced hose. Small leaks in suction line greatly reduce efficiency of pump and may prevent priming. 3

INSTALLATION (CONTINUED) MAINTENANCE Ordinary garden hose will collapse under suction pressure and should not be used for the inlet line. 6. Use a foot valve when pumping from a creek, pond, or source where foreign objects may be sucked into the pump. The foot valve should prevent solids from entering the inlet line. 7. A regular garden hose may be used as a discharge line. wildlife, and debris. Protect the pipe from damage by swimmers, Protéger le tuyau contre les dommages causés par les nageurs, les animaux et les débris. PRIME PLUG Let pump cool for at least 20 minutes before attempting to service. Motor MAY be extremely hot. Personal injury MAY result. Laisser refroidir la pompe pendant au moins 20 minutes avant d'essayer de la réparer. Le moteur PEUT être extrêmement chaud. Des blessures PEUVENT en résulter. 1. Pump should be checked before each use for proper operation. ALWAYS disconnect the electrical supply before attempting to operate, service, or perform any maintenance. If the power source is out of sight, lock and tag in the open (off) position to prevent unexpected power application. Failure to do so WILL result in fatal electrical shock. Only qualified electricians SHOULD repair this unit. Improper repair WILL result in fatal electrical shock. OUTLET HOSE ADAPTERS INLET TOUJOURS débrancher l'alimentation électrique avant d'essayer de faire fonctionner, d'entretenir ou d'effectuer toute opération de maintenance. Si la source d'alimentation est hors de vue, verrouiller et étiqueter en position ouverte (off) pour éviter une décharge électrique inattendue. Ne pas le faire ENTRAÎNERA un choc électrique mortel. Seuls les électriciens qualifiés DOIVENT réparer cet appareil. Une réparation incorrecte ENTRAÎNERA un choc électrique mortel. Figure 1 OPERATION Pump must be filled with water before operation. Running the pump dry will cause damage to the shaft seal. 1. This unit is not waterproof or weatherproof and is not intended to be used in showers, saunas, or other potentially wet locations. The motor is designed to be used in a clean, dry location with access to adequate cooling air. Ambient temperatures around the motor should not exceed 104 F (40 C). 2. Remove priming plug and fill with water. Replace plug (plumbers seal tape should be used on priming plug to prevent air leaks). 3. Plug power cord into GFCI protected electrical outlet. The pump will prime in a few minutes depending on suction line length. Use of foot valve on suction line is recommended for self-priming. 4. Unplug cord to turn unit off. BRUSH REPLACEMENT Brushes for this pump should be inspected after 100 hours of operation. Pumps with excess of 100 hours of operation may stop operating or fail to start. This could be due to worn brushes or carbon buildup. The brushes should be removed and carbon removed. Worn brushes are not covered under warranty. Replacement brushes may be available online. 1) Disconnect electrical cord from power supply. 2) Remove brush caps with screwdriver. 3) Remove old brush assembly. 4) Replace brushes, make sure springs do not pinch during assembly. Align/center tabs on the back of the brush spring with the flats on the brush hlder. Ref. fig 2. 5) Replace brush caps. For other problems, consult troubleshooting chart. 4

SERVICE PART REPLACEMENT ROTOR ASSEMBLY THRUST WASHER 50TK Instructional video available at www.blueangelpumps.com 1. Make sure the pump is unplugged and cooled down before disassembling the pump. 2. Release any pressure from the pump then disconnect any hoses or plumbing and drain the product. 3. Remove brush holder caps and brushes (make note of which side of the pump the brush was in also the orientation of the brush as you will want to put them back the same way they came out). Ref fig.3. Remove the (4) ¼-20 screws and lock washers holding the volute to the motor housing. Ref fig.3 BRUSH HOLDER CAP HEAD SEAL CERAMIC SEAL IMPELLER LOOSE TIGHT Figure 4 BRUSH ALIGN TABS ON BRUSH WITH FLATS ON BRUSH HOLDER Figure 2 VOLUTE GASKET 1/4-20 SCREW WASHER MOTOR HOUSING 7. Holding the rotor assembly with one hand unscrew the impeller from the rotor shaft (do not use a vise or other such device to hold the rotor as it may damage the rotor). 8. Remove both parts of the seal assembly from the back head and impeller. 9. Push the new head seal (part with the blue metal housing) over the rotor shaft and into the back head making sure the flange on the seal seats against the back head and making sure the black carbon side of the seal is facing away from the back head towards the impeller. 10. Push the ceramic seal into the impeller pocket making sure the white ceramic surface faces away from the back of the impeller. 11. Holding the rotor with one hand thread the new impeller onto the rotor shaft making sure it is tight on the shaft and the white face of the ceramic seal contacts the black carbon face of the head seal. Figure 3 4. Remove the volute. 5. Remove the gasket and discard. PRIMING FEATURE 6. Remove the rotor assembly from the motor housing. There is a thrust washer in the bearing pocket at the back of the motor housing, if the thrust washer falls out make sure it is put back into the pocket before reassembling. Ref fig. 4 12. Make sure the thrust washer is in the bearing pocket in the back of the motor housing and guide the rotor assembly back into the motor housing. Make sure the priming feature on the back head is on the bottom of the pump, the pump won t prime properly if this isn t in the correct location. Ref. fig. 3 13. Put the new gasket on the motor housing then reattach the volute to the motor housing using the four ¼-20 screws and lock washers. Torque the screws to 75 in. lbs. 14. Replace the brushes and caps, make sure to put them back in the same way they came out. Make sure the springs do not pinch during assembly and align/center the tabs on the back of the brush spring with the flats on the brush holder. Ref. fig. 2 15. Test thoroughly and check for leaks before use. 5

For Replacement Parts or Customer Support, Call 1-888-636-6628 Please provide following information: - Model number - Serial number (if any) - Part description and number as shown in parts list Address any correspondence to: Blue Angel Pumps 101 Production Drive Harrison, OH 45030 U.S.A. 1 2 Ref. No. Description Part Number Qty. 1 Brush kit 62015-WYN1 1 2 Impeller and seal kit 56671-WYN1 1 Note: Replacement parts are available in kit form only 6

50TK LIMITED WARRANTY For three years for 50TK model from the date of purchase, from an authorized dealer, Blue Angel Pumps will repair or replace, at its option for the original purchaser, any part or parts of its Multi-Use Pumps or Water Pumps ( Product ) found upon examination by Blue Angel Pumps to be defective in materials or workmanship. Please call Blue Angel Pumps (888-636-6628) for warranty instructions. Be prepared to provide the model number and the serial number when exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser. This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with Blue Angel Pumps written instructions. THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, OBLIGATIONS OR AGREEMENTS, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE SALE OF THE PRODUCT. THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING WITH RESPECT TO OR IN ANY WAY CONNECTED WITH THE PRODUCT, REGARDLESS OF THE SOURCE OR PROVIDER OF SUCH GOODS. IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT, WARRANTY TORT (INCLUDING NEGLIGENCE) OR OTHERWISE, SHALL BLUE ANGEL PUMPS OR ANY AFFILIATE BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along with the material or correspondence. Please call Blue Angel Pumps (888-636-6628) for return authorization and instructions. DO NOT MAIL THIS FORM TO Blue Angel Pumps. Use this form only to maintain your records. MODEL NO. SERIAL NO. INSTALLATION DATE ATTACH YOUR RECEIPT HERE 7

NOTES 8 www.blueangelpumps.com