MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

Similar documents
MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

14 AC x

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

2 shp 13 lc 1 36 t - 1 a

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

T S A 048 S 4 N 4 1 T

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

T P A 120 S 4 S N 1 Y

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

T P A 048 S 4 N 4 1 T

ELITE Series R-410A - Two-Stage Compressor

ELITE Series Variable Capacity

Visit us at For the latest technical information,

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

ELITE Series Variable Capacity

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

MERIT SERIES Up Flow / Horizontal

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes August 2008

SSB. S CLASS SPLIT SYSTEM R 410A Two Stage Compressor 60 HZ A I R C O N D I T I O N E R S

13 GEP A L P - 1 A

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

CB X 32 mv

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

RGE 13 A T - 1 A

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

XC21. DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

C22FC Bulletin # October 1993 Supersedes May 1993

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

Ruud Achiever Series Air Conditioners

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Commercial High-Efficiency Condensing Units

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Lennox 8 Series Single Zone - R-410A

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

PACKAGE AIR CONDITIONER

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

TECHNICAL SPECIFICATIONS

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

PAJ3. Product Specifications

C22 Bulletin # October 1993 Supersedes May 1993

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

MERIT SERIES Downflow

16 SEER TWO-STAGE AIR CONDITIONERS

MACH N-407 Heat Pump Air-Cooled Chiller

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

PRODUCT SPECIFICATIONS

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

MERIT SERIES Downflow

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

ELITE SERIES Downflow - High Efficiency Blower Motor

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

R4H4. Product Specifications

Transcription:

PRODUCT SPECIFICATIONS AIR CONDITIONERS ML4XC MERIT Series R-40A Bulletin No. 20834 March 209 Supersedes March 208 SEER up to 7.00.5 to 5 Tons Cooling Capacity - 8,000 to 60,000 Btuh MODEL NUMBER IDENTIFICATION Product Tier ML = Merit Series ML 4 X C - 036-230 A 0 Revision Level Nominal SEER 4 = 4 SEER Ratings Revision Level Refrigerant Type X = R-40A Voltage 230 = 208/230V- phase-60hz Unit Type C = Air Conditioner (Condenser) Cooling Stages = Single Stage Compressor Regional Standards (dash) = All Regions) S = Southeast and North Regions Nominal Cooling Capacity 08 =.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 04 = 3.5 tons 042 = 3.5 tons 047 = 4 tons 048 = 4 tons 059 = 5 tons 060 = 5 tons

FEATURES B CONTENTS Dimensions - Unit... 8 Electrical Data... 6 C Features... 2 Field Wiring... 9 D Installation Clearances... 9 Model Number Identification... Optional Accessories... 6 Sound Data... 0 Specifications... 6 TXV/Orifice Usage... 0 WARRANTY Compressor - limited warranty for five years in residential installations and five years in non-residential installations. All other covered components - five years in residential installations and one year in non-residential installations. Note - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPROVALS AHRI Certified to AHRI Standard 20/240. For AHRI Certified system match-ups and expanded ratings, visit www.lennoxpros.com. Sound rated in Lennox reverberant sound test room in Accordance with test conditions included in AHRI Standard 270-2008. Tested in the Lennox Research Laboratory environmental test room. Rated According to U.S. Department of Energy (DOE) test procedures. Region specific models meet the minimum efficiency requirements for U.S DOE Federal Regional Standards in that area. Units and components within bonded for grounding to meet safety standards for servicing required by UL, NEC and CEC. Units are ETL certified for the U.S. and Canada. ISO 900 Registered Manufacturing Quality System. ML4XC -.5 to 5 Ton Air Conditioner / Page 2 E F APPLICATIONS.5 through 5 ton. Sound levels as low as 73 db. Single-phase power supply. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See AHRI System Matches. See Indoor Coils and Air Handlers sections for data. Units shipped completely factory assembled, piped and wired. Each unit test operated at the factory ensuring proper operation. Installer must set air conditioner, connect refrigerant lines and make electrical connections to complete job.

B C FEATURES REFRIGERATION SYSTEM R-40A Refrigerant Non-chlorine, ozone friendly, R-40A. Unit pre-charged with refrigerant. See Specification table. Outdoor Coil Fan Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor has sleeve bearings (-08 through -048 and -060 models), ball bearings (-059 model) and is inherently protected. Motor totally enclosed for maximum protection from weather, dust and corrosion. Rain shield on motor provides additional protection from moisture. Louvered steel top fan guard furnished as standard. Fan service access accomplished by removal of top panel. High Pressure Switch Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Manual reset. Quantum Coil Lennox designed and fabricated coil. Enhanced aluminum alloy tube/enhanced fin coil for superior corrosion resistance. Ripple-edged aluminum fins. Aluminum tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to ensure leakproof construction. Steel louvered panels provide complete coil protection. Panels can be completely removed for servicing. High Capacity Liquid Line Drier Furnished with unit for field installation. Approved for use with R-40A systems. Traps any moisture or dirt that could contaminate the refrigerant system. Refrigerant Flow Control Units applicable to expansion valve systems or RFC systems when matched with specific indoor coils. RFCIV: Accurately meters refrigerant in system. Refrigerant control is accomplished by exact sizing of refrigerant metering orifice. The principle involves matching indoor coil with proper bore size of orifice in metering device. Equalizes pressure shortly after compressor stops, unit starts unloaded, eliminating need for additional controls. Furnished with air conditioner. Optional Accessories O RING RFCIV METERING SYSTEM ORIFICE BODY RFCIV (On Coil) LIQUID LINE SCREEN SEAL NUT ORIFICE LIQUID LINE SWEAT CONNECTION Expansion Valve Kits Must be ordered extra and field installed on certain indoor units. See Refrigerant Metering Devices table. Chatleff-style fittings. Freezestat Installs on or near the vapor line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it s setpoint. Opens at 29 F and closes at 58 F. Loss of Charge Switch Kit Helps protect the compressor from damage due low refrigerant charge conditions. SPST, normally-closed switch, automatic reset switch mounted on suction line. Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at factory. Suction line fully insulated. Lines are stubbed at both ends. Not available for -059-060 models. Must be field fabricated. ML4XC -.5 to 5 Ton Air Conditioner / Page 3

FEATURES D COMPRESSOR Scroll Compressor Compressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Compressor is installed in the unit on resilient rubber mounts for vibration free operation. Compressor Crankcase Heater (-04, -047, -048, -059 & -060 Models) Protects against refrigerant migration that can occur during low ambient operation. Optional Accessories Compressor Crankcase Heater (Optional for 08-024-030-036-042) Protects against refrigerant migration that can occur during low ambient operation. Compressor Sound Cover A reinforced vinyl compressor cover containing a -/2 inch thick batt of fiberglass insulation. All open edges are sealed with a one-inch wide hook and loop fastening tape. CONTROLS Optional Accessories icomfort M30 Smart Wi-Fi Thermostat Wi-Fi-enabled, electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/2 Cool. Auto-changeover. Dual-fuel control with optional outdoor sensor. Controls dehumidification during cooling mode and humidification during heating mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy to read 4.3 in. color touchscreen (measured diagonally). LCD display with backlight shows the current and set temperature, time, inside relative humidity, system status (operating mode and schedules) and outside temperature (optional outdoor sensor required). Smooth Setback Recovery starts system early to achieve setpoint at start of program period. Compressor short-cycle protection (5 minutes). Up to four separate schedules are available plus Schedule IQ. One-Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away. Smart Away - Uses geo-fencing technology to determine when the homeowner is within a predetermined distance from the home to operate the system when leaving, away and arriving. Amazon Alexa-enabled, smart-home-compatible. It works with Amazon Echo, Echo Dot and Tap devices. Wi-Fi remote monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. See the icomfort M30 Smart Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. Remote Outdoor Temperature Sensor Used with the icomfort M30 Smart Thermostat. When installed outdoors, sensor allows thermostat to display outdoor temperature. Sensor is auto-detected when connected to thermostat. NOTE - Sensor is required for the Enhanced Dehumidification Accessory (EDA). ML4XC -.5 to 5 Ton Air Conditioner / Page 4

FEATURES CONTROLS (continued) Optional Accessories (continued) Thermostat Thermostat (programmable/non-programmable) is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book for selection. Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor. This type of motor normally doesn t need a potential relay and start capacitor. In conditions such as low voltage, this kit may be required to increase the compressor starting torque. Compressor Low Ambient Cut-Off Switch Non-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35 F. Compressor Time-Off Control Kit prevents compressor short-cycling and allows time for suction and discharge pressure to equalize. Permits compressor start-up in an unloaded condition. Automatic reset with 5 minute delay between compressor shut-off and start-up. Indoor Blower Off Delay Relay Delays the indoor blower-off time during the cooling cycle. See AHRI System Matches for usage. Low Ambient Kit Air conditioners operate satisfactorily in the cooling mode down to 45 F outdoor air temperature without any additional controls. Kit can be added in the field enabling unit to operate properly down to 30 F in the cooling mode. Crankcase heater and freezestat should be installed on compressors equipped with a Low Ambient Kit. A compressor lock-out thermostat should be added to terminate compressor operation below recommended operation conditions. E F CABINET Heavy gauge steel cabinet with five station metal wash process. Louvered heavy gauge steel panels surround unit on all four sides to prevent damage to the coil. Powder paint finish provides superior rust and corrosion protection. Control box is conveniently located with all controls factory wired. Corner patch plate allows access to compressor components. Drainage holes are provided in base section for moisture removal. PermaGuard Unit Base Durable zinc-coated base section resists rust and corrosion. Refrigerant Line Connections, Electrical Inlets, Service Valves Sweat connection suction and liquid lines are located on corner of unit cabinet. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Refrigerant line connections and field wiring inlets are located in one central area of cabinet for easy access. See dimension drawing. Optional Accessories Unit Stand-Off Kit Black high density polyethylene feet are available to raise unit off of mounting surface away from damaging moisture. Four feet are furnished per order number. ML4XC -.5 to 5 Ton Air Conditioner / Page 5

SPECIFICATIONS General Model No. All Regions ML4XC-08 ML4XC-024 ML4XC-030 ML4XC-036 ML4XC-04 Data Southeast and North Regions ML4XCS08 ML4XCS024 ML4XCS030 ML4XCS036 - - - Nominal Tonnage.5 2 2.5 3 3.5 Indoor Unit Expansion Valve (TXV) (If needed) 2J8 2J8 2J8 2J9 2J20 RFCIV Metering Orifice Usage 0.052 0.060 0.060 0.07 N/A Connections Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8 (sweat) Suction line o.d. - in. 3/4 3/4 3/4 7/8 7/8 Refrigerant (R-40A) furnished 4 lbs. 9 oz. 4 lbs. 9 oz. 5 lbs. 8 oz. 8 lbs. 0 oz. 9 lbs. 0 oz. Outdoor Coil Outdoor Fan Net face area sq. ft. Outer coil 3.22 6.33 2.00 8.67 2.00 Inner coil - - - - - - - - - 7.96 20.25 Tube diameter - in. 5/6 5/6 5/6 5/6 5/6 Number of rows 2 2 Fins per inch 26 26 26 22 22 Diameter - in. 8 22 22 22 22 Number of blades 3 3 3 3 3 Motor hp /0 /6 /6 /6 /6 Cfm 2290 360 360 360 3050 Rpm 075 825 825 825 825 Watts 60 25 25 90 90 Shipping Data - lbs. package 34 52 69 90 92 ELECTRICAL DATA Line voltage data - 60 hz - ph 208/230V 208/230V 208/230V 208/230V 208/230V 2 Maximum overcurrent protection (amps) 20 25 25 30 30 3 Minimum circuit ampacity.9 4.6 7 8.6 9.3 Compressor Rated load amps 9.0 0.9 2.8 4. 4.7 Locked rotor amps 48 59.3 67.8 83 75 Power factor 0.97 0.97 0.97 0.96 0.96 Condenser Full load amps 0.7 Fan Motor Locked rotor amps.3.9.9.9.9 CONTROLS icomfort M30 Smart Wi-Fi Thermostat 5Z69 Remote Outdoor Temperature Sensor X2658 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 Factory Compressor Hard Start Kit Copeland 0J42 LG 88M9 Compressor Low Ambient Cut-Off Switch 45F08 Compressor Sound Cover 69J03 Compressor Time-Off Control 47J27 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M8 Loss of Charge Switch Kit 84M23 4 Low Ambient Kit (Fan Cycling) 34M72 Refrigerant Line L5-4-20, L5-4-30, Sets L5-4-40, L5-4-50 L5-65-30, L5-65-40, L5-65-50 Unit Stand-Off Kit 94J45 NOTE - Extremes of operating range are plus 0% and minus 5% of line voltage. Refrigerant charge sufficient for 5 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type circuit breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. ML4XC -.5 to 5 Ton Air Conditioner / Page 6

SPECIFICATIONS General Model No. All Regions ML4XC-042 ML4XC-047 ML4XC-048 ML4XC-059 ML4XC-060 Data Southeast and North Regions ML4XCS042 - - - - - - - - - - - - Nominal Tonnage 3.5 4 4 5 5 Indoor Unit Expansion Valve (TXV) (If needed) 2J20 2J20 2J20 2J20 2J20 RFCIV Metering Orifice Usage 0.08 N/A 0.083 N/A 0.097 Connections Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8 (sweat) Suction line o.d. - in. 7/8 7/8 7/8 -/8 -/8 Refrigerant (R-40A) furnished 8 lbs. 2 oz. lbs. 0 oz. 9 lbs. 2 oz. lbs. 3 oz. 2 lbs. 0 oz. Outdoor Coil Outdoor Fan Net face area sq. ft. Outer coil 2.00 22.7 2.00 29.09 29.09 Inner coil 20.25 2.33 20.25 28.6 28.6 Tube diameter - in. 5/6 5/6 5/6 5/6 5/6 Number of rows 2 2 2 2 2 Fins per inch 22 22 22 22 22 Diameter - in. 22 26 22 26 26 Number of blades 3 4 4 4 4 Motor hp /6 /3 /4 /3 /3 Cfm 3050 4400 3600 4550 4550 Rpm 825 825 825 820 825 Watts 90 30 30 25 30 Shipping Data - lbs. package 2 23 28 253 267 ELECTRICAL DATA Line voltage data - 60 hz - ph 208/230V 208/230V 208/230V 208/230V 208/230V 2 Maximum overcurrent protection (amps) 40 35 40 45 50 3 Minimum circuit ampacity 23.4 2.9 24.2 28.8 29.6 Compressor Rated load amps 7.9 6. 8 20.8 22.2 Locked rotor amps 2 05.5 7 27. 27.9 Power factor 0.96 0.98 0.96 0.98 0.98 Condenser Fan Motor CONTROLS Full load amps.8.7 2.8.8 Locked rotor amps.9 2.9 3.2 - - - 2.9 icomfort M30 Smart Wi-Fi Thermostat 5Z69 Remote Outdoor Temperature Sensor X2658 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 Factory Compressor Hard Start Kit Copeland 0J42 LG 88M9 Compressor Low Ambient Cut-Off Switch 45F08 Compressor Sound Cover 69J03 Compressor Time-Off Control 47J27 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M8 Loss of Charge Switch Kit 84M23 4 Low Ambient Kit (Fan Cycling) 34M72 68M04 Refrigerant Line L5-65-30, L5-65-40, Sets L5-65-50 Field Fabricate Unit Stand-Off Kit 94J45 NOTE - Extremes of operating range are plus 0% and minus 5% of line voltage. Refrigerant charge sufficient for 5 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type circuit breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. ML4XC -.5 to 5 Ton Air Conditioner / Page 7

DIMENSIONS INLET AIR 4-3/8 4-3/8 () () 4-3/8 4-3/8 () () INLET INLET OPTIONAL UNIT STAND-OFF KIT (4) (Field Installed) COMPRESSOR AIR AIR COIL DRAIN OUTLETS (Around perimeter of base) SUCTION LINE CONNECTION 6-3/8 (62) 4-3/8 () INLET AIR TOP VIEW LIQUID LINE CONNECTION 6-3/8 (62) 4-3/8 () TOP VIEW BASE SECTION A OUTDOOR COIL FAN A DISCHARGE AIR COMPRESSOR C B ELECTRICAL INLETS SUCTION AND LIQUID LINE CONNECTION 2-3/4 (70) 2 (5) SIDE VIEW 3/4 (9) OPTIONAL UNIT STANDOFF KIT (4) (FIELD INSTALLED) SIDE VIEW Model A B C inches mm inches mm inches mm 08 24-/4 66 29-/4 743 28-/2 724 024 28-/4 78 29-/4 743 28-/2 724 030 28-/4 78 37-/4 946 36-/2 927 036 28-/4 78 33-/4 845 32-/2 826 04 28-/4 78 37-/4 946 36-/2 927 042 28-/4 78 37-/4 946 36-/2 927 047 32-/4 87 33-/4 845 32-/2 826 048 28-/4 78 37-/4 946 36-/2 927 059 32-/4 87 43-/4 099 42-/2 080 060 32-/4 87 43-/4 099 42-/2 080 ML4XC -.5 to 5 Ton Air Conditioner / Page 8

FIELD WIRING INSTALLATION CLEARANCES DISCONNECT SWITCH (By Others) THERMOSTAT (Optional) DISCONNECT SWITCH (By Others) See NOTES B D A LENNOX AIR CONDITIONER C LENNOX HEATING UNIT OR AIR HANDLER UNIT See NOTES See NOTES See NOTES CONTROL BOX A - Two Wire Power (not furnished). See Indoor Unit Electrical Data B - Two Wire Power (not furnished). See Electrical Data C - Four Wire Low Voltage (not furnished). 8 ga. minimum D - Five Wire Low Voltage (not furnished). 8 ga. minimum All wiring must conform to NEC or CEC and local electrical codes. NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (94 mm) Clearance to one of the remaining two sides may be 2 in. (305 mm) and the final side may be 6 in. (52 mm). A clearance of 24 in. must be maintained between two units. 48 in. (29 mm) clearance required on top of unit. ML4XC -.5 to 5 Ton Air Conditioner / Page 9

SOUND DATA Unit Model Octave Band Linear Sound Power Levels db, re 0-2 Watts Center Frequency - HZ Sound Rating Number (db) ² Estimated Sound Pressure Level at Distance From Unit (db at distance in ft.) 25 250 500 000 2000 4000 8000 3 5 0 5 50 08 53.0 58.5 66.5 69.5 65.0 62.5 54.5 73 66 6 55 52 4 024 56.0 66.0 72.0 7.0 67.0 63.0 56.5 76 69 64 58 55 44 030 55.0 64.5 70.5 72.5 67.5 6.0 54.0 76 69 64 58 55 44 036 58.0 67.5 7.5 70.5 66.5 6.5 55.0 76 69 64 58 55 44 04 56.5 64.0 70.0 69.0 66.0 62.5 56.0 74 67 62 56 53 42 042 56.0 65.0 7.0 7.5 67.5 62.0 55.0 76 69 64 58 55 44 047 6.5 7.5 76.5 75.5 7.5 65.5 56.5 80 73 68 62 59 48 048 6.5 68.0 73.5 72.5 69.0 64.0 56.5 78 7 66 60 57 46 059 62.0 69.5 73.0 7.0 69.0 63.5 55.0 77 70 65 59 56 45 060 63.5 70.0 75.0 75.0 70.5 68.0 6.0 80 73 68 62 59 48 NOTE - the octave sound power data does not include tonal correction. Tested according to AHRI Standard 270-2008 test conditions. 2 Estimated sound pressure level at distance based on AHRI Standard 275-200 method for equipment located on the ground, roof, or on side of building wall with no adjacent reflective surface within 9.8 feet. Sound pressure levels will increase based on changes to assumptions. For other applications, refer to AHRI Standard 275. TXV/ORIFICE USAGE Use this table for C35, CH23, CH33, CH35 and CR33 Field Installed TXV/Orifice Match-Ups. Model Refrigerant Metering Orifice (RFC) Order No. Orifice Size ML4XC -.5 to 5 Ton Air Conditioner / Page 0 Thermal Expansion Valve (TXV) 08 0W94 0.052 2J8 024 0W97 0.060 2J8 030 W00 0.067 2J8 036 W0 0.07 2J9 04 N/A N/A 2J20 042 W06 0.08 2J20 047 N/A N/A 2J20 048 W07 0.083 2J20 059 N/A N/A 2J20 060 0M3 0.097 2J20 CX35 and CX38 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. If a change out is required it will be listed in the TXV SUBSTITUTIONS table. The correct TXV must be ordered separately and field installed. C35, CH33/CH35 coils - Use the orifice shipped with the outdoor unit or replace the factory installed orifice with the expansion valve listed. CR33 and CH23 coils - Use the orifice shipped with the outdoor unit or use the expansion valve listed. MOST POPULAR MATCHES Outdoor Unit Model Indoor Unit Model No 08 CX38-25B 024 CX38-25B 030 CX38-3B 036 CX38-38B 04 CX38-49C 042 CX38-49C 047 CX38-62C 048 CX38-62C 059 CX38-62C 060 CX38-62C *TXV SUBSTITUTIONS Use this table to determine if the factory installed TXV in the indoor unit needs to be replaced. Model Indoor Coil or Air Handler Factory TXV Replacement TXV 030 CX35-48 2J20 2J8 * CX35 coils - The factory installed expansion valve must be replaced with the expansion valve listed (ordered separately). If the combination is not listed above, the factory installed TXV is used. AHRI STANDARD 20/240 Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation. Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 250 Btu/h per,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per,000 cfm of indoor air circulated.

REVISIONS Sections Optional Accessories Added icomfort M30 Smart Thermostat. Description of Change Visit us at www.lennox.com For the latest technical information, www.lennoxpros.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 209 Lennox Industries, Inc.