Digital Switchgear Communication at Eye Level The new xeffect Digital Series planb.eu

Similar documents
Arc Fault Protection ARCON. ARCON. The Lightning Fast Airbag for Your Switchboard.

xcomfort Make your house smarter

Installation and user manual for the BiWire / Conventional Repeater Panel

xcomfort Climate protection starts in your home

New GuideLed safety luminaires

D1000 Arc-fault Protection System

Arc Fault Protection ARCON ARCON. The Lightning Fast Airbag for Your Switchboard.

PGR-8800 TECHNICAL FAQ

Welcome to Hager Presentation

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

Arc Fault Protection System D1000

Effective, efficient response for emergency situations Risk Management

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Electric Shock Drowning

Sirios LED Emergency Lighting Instruction and Operation Manual

AmpLight Lighting Management System

MAINTENANCE OF LV SWITCHGEAR SECTOR / ENGINEERING TECHNICAL & CERTIFIED TRAINING COURSE

Eaton training solutions Accredited CPD seminars. LED Emergency and Mains Lighting Contents. Knowledge for your business

PRO Installation. Thermostat Wi-Fi

SEL Arc-Flash Solutions

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

SEL Arc-Flash Solutions

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

PRO Installation. Touch Wi-Fi Thermostat

PROCESS AUTOMATION TIME TO RELAX ADVANCED DIAGNOSTICS EXPERT SYSTEM AT WORK

THERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR

Operation and use. Functions and characteristics

Security System. User Guide for the LED Command Center

User s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE

PRO Installation. Touch Wi-Fi Thermostat

F3SJ Overview. Three Versions available to meet your exact safety needs. Safety Light Curtains NEW! Introducing the F3SJ Series

xcomfort Climate protection starts in your home

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Operation & Maintenance Manual

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

Control Products & Systems OEM

JA-63 Profi User manual

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

AmpLight group management

Swedish design and manufacture since 1967

Electrical Safety Compliance: NFPA 70E

3 User s settings. 3.3 Internal clock setting

5SM6 AFD unit preventive, proven, standard-compliant

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

DOCUMENTATION IPS640

DOCUMENTATION IPS640

ABB Medium Voltage Days MEA 2016 Proactive safety ABB medium-voltage switchgear

Sirios LED Product overview. When Safety depends on the decisions you make

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

EOTec 2C32 Installation Guide

FB10000 Error Messages Troubleshooting

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

Side-by-side combined refrigerator-freezer

Control Products & Systems OEM

Operation Manual Airbrush Compressor AH28A ARTICLE 34247

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

Wireless thermostat SI-3 Installation and user guide

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Operation Manual. Programmable Logic Controller

compact office 24V compact office 24V Lux

Preliminary Operations and Maintenance Plan Baron Winds Project

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

The electrical installation like you ve never seen before

Air Cooled Scroll Chiller / Heat Pump

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS: RESIDUAL CURRENT DEVICES

Powerohm Resistors Digital HRG System

Load monitoring with integrated potential distribution maxguard the innovative control voltage distribution system Let s connect.

GradeShift G2r/G3r INSTallaTIoN MaNUal

Security System. User s Guide for the Text Command Center

BTICINO HOME AUTOMATION. THE NATURAL EVOLUTION OF YOUR HOME.

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

2. Safety. 4. Function

Operating instructions

Enhanced FOUNDATION Fieldbus Physical Layer Diagnostics with the DeltaV System

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

PRESENTS AQUADUCT AUTOMATED WATER-LEAK MONITORING SYSTEM A KINGPIN TECHNOLOGY

600 Range Dialer Installation Manual. Version 1.0

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

Products :: Circuit Protection :: Thermal Circuit Breakers

MDS-15. High-throughput Microwave Sample Preparation Workstation. The Transformer of Microwave Digestion

THE INTELLIGENCE BEHIND THE MOST INNOVATIVE FIRE DETECTION SYSTEMS

ECO-IR 360C NT. Presence detector. Art. Nr Bedienungsanleitung 2. Notice d utilisation 22. Installation manual 42

compact office 24V compact office 24V Lux

DAY/TIME Button: Selects hour, minute and day setting.

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Complete the table to show which size fuse, 3 A or 13 A, should be fitted to each of the appliances. Appliance Power Fuse

TFD-1 Installation & User s Guide

Total overview with a web-based alarm service centre.

Arc Fault Detection Devices (AFDDs) Protecting People and Property

Spectron LSN (Life Safety Network) Suggested Specifications

Transcription:

Digital Switchgear Communication at Eye Level The new xeffect Digital Series planb.eu 1

Yesterday, the future was yet to come. Today, it s already here. The future has already begun. For us, innovation is tradition: in 1957 Eaton s Moeller segment developed the first fault current protection switch, and with this, a new era of electrical safety engineering began. And now, Eaton is still ahead of its time: the new digital switchgear range in the Eaton xeffect series communicates potential problems in advance and sets new standards in precision, security and convenient service. Maximal safety with optimal ease Modern Residual Current Circuit Breakers (RCCB) protect people and technical equipment conveniently and reliably against faulty currents. The digital RCCB from the xeffect series do more than just switch off. They monitor electrical installations and give advance warning of critical current flows. So plant / factory shutdowns and the resulting costs can be avoided. Precise Release Highest Reliability Short-time fault currents or other briefly occurring malfunctions do not cause the digital protection switch to shut down, thanks to the short time delay and optimized tripping threshold. So the electrical installation is optimally protected against power failures. Easy and adaptable installation for fast modernization The big Eaton Plus: It is very easy to upgrade a switchboard! Simply replace the RCCB and you have all advantages of digitalization. 2

Digital protection switches the new era has begun. More security through proactive communication! The new xeffect models exceed the IEC/EN-61008 standard: their trigger reaction is much more precise than that of conventional switches to the 100% fault current threshold. With a fault current, the information is reported to the security center of the industrial plant, and troubleshooting would begin before there would be a shutdown or plant failure. So the cause of the fault current can be determined precisely and the system service can be easily planned ahead. Therefore, system availability is increased and service is improved because of the convenience of the remote control. Numerous advantages at a glance The difference between harmless and critical fault currents is detected Precise switching and reduction of nuisance tripping Continuous monitoring of plant/factory status prompt warning of a change in status quo Convenient troubleshooting by precise location of the malfunction As easy to install as a conventional RCCB Longer intervals between servicing Ideal for system monitoring thanks to preventive information Warning of tripping at leakage current Clear status display of the fault current problem with tri-colored LEDs Real contact position indicator Indicator for fault current tripping Comprehensive range of accessories available Can be integrated in several bus systems 3

Yesterday, the future was yet to come. Today, it s already here. The future has already begun. To us, innovation is tradition: in 1957, Eaton s Moeller segment developed the first fault current protection switch, and with this, a new era of electrical safety engineering began. And now, Eaton is still ahead of its time: the new digital switchgear range in the Eaton xeffect series communicates potential problems in advance and sets new standards in precision, safety and convenience. Maximal safety with optimal ease Modern Residual Current Circuit Breakers (RCCB) protect people and technical equipment conveniently and reliably against faulty currents. The digital RCCB from the xeffect series do more than just switch off. They monitor electrical installations and give advance warning of critical current flows. So plant / factory shutdowns and the resulting costs can be avoided. Precise Release Highest Reliability Thunderstorms or other briefly occurring malfunctions do not cause the digital protection switch to shut down, thanks to the short time delay and optimized tripping threshold. So the electrical installation is optimally protected against power failures. Easy and adaptable installation for fast modernization The big Eaton Plus: It is very easy to upgrade a switchboard! Simply replace the RCCB and you have all advantages of digitalization. 4

Digital protection switches the new era has begun. Better safety in your home thanks to proactive communication! The new xeffect series digitalizes the residual current protection of every house and makes the entire building considerably safer than with the use of conventional protection switches. The installation of digital switchgears by Eaton has additional advantages, especially with bus system installations. In the case of fault currents, the information goes to the central office of the building and troubleshooting can begin before there is a shutdown or failure of the system. So the cause of the fault current can be investigated precisely and the system can be serviced effortlessly. Through the connection to a GSM module, status reports can also be sent to mobile terminals. This means that system availability can be increased and service enhanced through the convenience of remote maintenance. Numerous advantages at a glance Simple upgrade of the switchgear cabinet in a few simple steps The difference between harmless and critical fault currents is detected Precise switching and reduction of nuisance tripping Continuous monitoring of plant/factory status prompt warning of a change in status quo Convenient troubleshooting by precise location of the malfunction As easy to install as a conventional RCCB Warning of tripping at leakage current Clear status display of the fault current problem with tri-colored LEDs Indicator for fault current tripping No monthly test necessary Comprehensive range of accessories available Can be integrated with the xcomfort wireless system and other bus systems 5

Highly qualified controllers offer their services PROMOTION Allow us to introduce ourselves: FRCdM and FRBdM would like to work in your switchbox. We re two highly qualified control robots from the famous EATON talent factory the first of the new digital generation. The LEDs set off an alarm when fault currents or a shut down are coming. This makes the troubleshooting faster and much easier. The service mode of the fault current protection switch quickly indicates the extent of the flowing fault current in milliamp increments. By pushing the service button, the blinking LED identifies the area where the fault current is located in. It s not only that I work completely reliably as a Residual Current Operated Circuit Breaker with integrated Overcurrent Protection (RCBO), but I also display the cause and extent of the flowing fault current. This enables fast actions quickly take measures to maintain system availability. And since I m the RCCB a fault current protection switch, I don t wait until the tripping threshold is reached; I continuously check the present status and register any possible failures, sending this information by remote warning immediately to the central control system. This increases system safety, application availability and minimizes maintenance costs. Hire us and finally experience communication at eye level! Mains voltage-independent residual current protection and additional protection with other digital functions Auto-reclosure is possible Red When the red LED lights up, the leakage current is already higher than 50 percent of the nominal fault current. Therefore the system is in a critical status the digital RCCB only trips when the fault current continues to increase. Yellow The yellow LED shows a residual current in the ambit of 30 to 50 percent of the nominal fault current. Before the system is shut down, professional countermeasures can be taken. Green If the current flow in the system to ground is in the ambit from 0 to 30 percent of the nominal fault current, the green LED indicates the proper status. 6

FRBdM and FRCdM offer several other advantages The LED allows for a fault current display directly on site. In the service mode, malfunction causes can be determined quickly and without complication. The digital display facilitates real-time diagnostics directly at the switch. By means of the LEDs, the system status can be seen at anytime, and with one glance. Digital Combi-switch FRBdM: With help of the service mode, the exact extent of the leakage current can be identified. This is a big advantage for industrial plants and any locations where the maximum security of supply must be ensured in time before the shut down of the plant. All models have at least a short time delay to prevent from nuisance tripping due to transient disruptions (lightning, engine start). Digital RCCB type A Protection in case of specific, non-smooth types of DC fault currents. Digital RCCB type B In addition to fault currents in the AC and pulse current range, type B also detects DC fault currents, which can occur in frequency inverter controls, photovoltaic systems as well as through the electronic use in households, and increases safety considerably. Digital RCCB type B+ Complies with the standard VDE 0664-400 (formerly VVDEV 0664-110) for elevated fire protection as required by the Association of German Insurance Companies. Digital RCCB type Bfq Adjusted frequency range (insensitive to higher frequencies) prevents nuisance tripping errors in industrial plants with powerful frequency inverter controllers. 7

Eaton is dedicated to ensuring that reliable, efficient and safe power is available when it s needed most. With unparalleled knowledge of electrical power management across industries, experts at Eaton deliver customized, integrated solutions to solve our customers most critical challenges. Article number xxxxxx Our focus is on delivering the right solution for the application. But, decision makers demand more than just innovative products. They turn to Eaton for an unwavering commitment to personal support that makes customer success a top priority. For more information, visit /electrical To contact an Eaton salesperson or local distributor/agent, please visit /electrical/customersupport Eaton Industries (Austria) GmbH Scheydgasse 42 1215 Wien Austria Eaton Industries Manufacturing GmbH EMEA Headquarters Route de la Longeraie 71110 Morges Switzerland 2012 Eaton Industries (Austria) GmbH Subject to technical modifications. No responsibility is taken for misprints or errata. Printed in Austria (11/12) Publication number Grafics: SRA DigiPics, Lithos: Print: