METS MODEL E-106. (115 VAC, 60 Hz) USER S MANUAL INSTALLATION OPERATION MAINTENANCE

Similar documents
METS MODEL E-112. (115 VAC, 50/60 Hz) USER S MANUAL INSTALLATION OPERATION MAINTENANCE TABLE OF CONTENTS

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

2364 Leicester Road, P.O. Box 175, Leicester, NY Phone (585) Fax (585)

WITH BATCH CONTROLLER, DIGITAL DISPLAY, MICROPROCESSOR CONTROLS, AND CAUSTIC DOSER TIMER (230 VAC, 50/60 Hz) USER S MANUAL

OPERATING INSTRUCTION MANUAL. Mark 3XE Silver Recovery Unit

Model # VWK-2 INSTRUCTION MANUAL

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Instruction Manual. Pressure Washer. Get ready to deep clean! Wards.com Wards.com ITEM:

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

WHEATGRASS JUICER C O M M E R C I A L. INSTRUCTION MANUAL Model No

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

aquamanta the experts in aquatic technology

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

STAINLESS STEEL ELECTRIC KETTLE

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Turbo Stick Vac. OWNER S MANUAL Model EP V., 60Hz., 7.5 Amps.

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTION MANUAL. Mark 2DC Silver Recovery Unit

BL250. Pulse Blender OWNER S GUIDE

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Instruction Manual. Cheese Warmer with Pump

USER MANUAL. Bottled Water Dispenser SAVE FOR FUTURE USE. Model #

Air Pump Up to 800 gallons

Pressurized Filter Up to 1250 gallons

REIMERS ELECTRA STEAM, INC. INSTRUCTION MANUAL JG & JJ MODELS

100 Series Maxi Internal Filters

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Garment Steamer Model SC620

Use and Care Instructions

52 BAYTOWNE CEILING FAN

SANI-VAC MODEL #750 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL. & WEAR EYE PROTECTION

Professional Stackable Chopper

Instruction Manual Item No.: V~, 60Hz

music hall wcs-2 wet vacuum record cleaner music hall audio llc

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

Master Prep Professional

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

Instruction Manual for the Revolutionary Science RS-IF-203 Incufridge

P/N CC-100. Coolant Circulator. Operation manual

QB1000 series OWNER S GUIDE. Professional. Master Prep. ninjakitchen.com

OPERATIONS MAINTENANCE MANUAL

Installation & Service Guide

jug kettle 1.7 litres/quarts

PWC 7000 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model Copyright 2012 Vertex Water Products

48 TAYLOR CEILING FAN

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

Alkaline RO System INSTALLATION MANUAL

2 Gallon Water Boiler

Autotrol Performa FA Valve

MODEL 7000 SUCTION UNIT

MODEL # ES

Revolutionary Science RS-IF-202

User Manual. 40 Tower Fan MODEL: WFTR40W

PWC-500/1000/1010/1500

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

A2Z Ozone, Inc. PRODUCT MANUAL

Thank You & Congratulations On Your Purchase of: ARBE Model # SS-206 Table Top Dust Collector

USE & CARE INSTRUCTIONS 10- SPEED HAND MIXER FSHM100


Wilbur Curtis Company, Inc. Service Manual WB-10 Water Boiler

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

SERVICE MANUAL. Bradford White ElectriFLEX HD (Heavy Duty) Commercial Electric Water Heater CEHD SERIES Immersion Thermostat Models

INSTALLATION & OPERATING INSTRUCTIONS

Canister Vacuum. OWNER S MANUAL Models CV520HB/HR/HY 120V., 60Hz., 10 Amps

1 P a g e. G4 Counter Top OPERATION MANUAL

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

LIMITED LIFETIME WARRANTY

High Speed Personal Blender

16 9.2QT Electric Skillet Instruction Manual MODEL FPB

InstructIon Manual KrEs EQuIPMEnt stands

Instruction Manual. Bucket Oil Pump

THE DAVENPORT CEILING FAN INSTALLATION INSTRUCTIONS

NJ100 Series OWNER S GUIDE. Express Chop

USE AND CARE MANUAL. Before operating the iron, please read these instructions carefully and keep them for future reference.

RELIABLE. RIGHT THERE WITH YOU. At Reliable, we do what we love, and take pride in doing it right. You want what s best for the people, places and thi

SOUP COOKER/WARMER 120V, 240V MODEL 6423 INSTRUCTIONS. Installation Operation Maintenance

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

Salad Assistant Instruction Manual

Eliza HLK 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Instruction Manual MODEL: GDUF Cu. Ft. Capacity 120V~, 60Hz, 115W

Instruction Manual. Double Candy Apple Cooker

CONSTANT SUCTION UNIT

Towel Warmer. Luxurious warmth for towels, robes and blankets

IRENE-HLK 60", 52" or 42" CEILING FAN

Bravetti. Please insert picture of unit. Stick Blender/Chopper. Use and Care Instructions. Read These Instructions Before Use

VARIABLE SPEED GRINDER OWNER S MANUAL R MANUAL VERSION SERIAL #

Eco-Steamer SSC-0312 INSTRUCTION MANUAL CONTENTS

DISCOVERY Instruction Manual Model #2556

Instruction Manual for the Revolutionary Science RS-PB-200 Dual Poly Pro Bath

SuperKlean Washdown Products

QUAD BLADE FOOD PROCESSOR

MIGHTY PRO 1/4 HP CHILLER

Transcription:

METS MODEL E-106 (115 VAC, 60 Hz) USER S MANUAL INSTALLATION OPERATION MAINTENANCE CPAC Equipment, Inc. 2364 Leicester Road, Leicester, NY 14481 Phone (585)382-3223 Fax (585)382-9481 www.cpacsilver.com 11/16

TABLE OF CONTENTS Recommendations 3 Important Safeguards 3 Introduction 4 Installation 4 Operation 5 How to Change a METS-E-106 Cartridge 6 Draining METS Cartridge for Shipping 7 Poppet Valve Removal 7-8 Bellows Pump Flow Adjusting Instructions 9 Optimal Performance Notice 10 Disclaimer 10 Statement of Warranty 10 2

RECOMMENDATIONS Read the entire instruction manual before installation or operation of the METS mini environmental treatment system. It will help you to understand the operation of the system, how various sub assemblies work together and the operating sequence of the controls. WARNING: NEVER ATTEMPT TO PERFORM ANY ELECTRICAL TROUBLESHOOTING ADJUSTMENT(S) OR SERVICE(S) UNLESS YOU ARE A QUALIFIED ELECTRICIAN, ELECTRONICS TECHNICIAN OR FACTORY TRAINED SERVICE TECHNICIAN. IMPORTANT SAFEGUARDS When using your METS mini environmental treatment system, these basic safety precautions should be followed: 1. Read and understand all instructions. 2. Care must be taken to avoid burns from touching hot parts. 3. Do not operate this appliance with a damaged cord or if appliance has been dropped or damaged until it has been examined by a qualified service technician. 4. Do not let power cord hang over edge of table or counter or touch hot surfaces. 5. An extension cord should not be used with this unit. The unit should be plugged directly into a power outlet. 6. To protect against electrical shock hazard, do not immerse this appliance in water or other liquids. 7. To avoid electrical shock hazard, do not disassemble this appliance. Call a qualified service technician when service or repair work is required. Incorrect reassembly can cause electric shock hazard when the appliance is switched ON. SAVE THESE INSTRUCTIONS 3

INTRODUCTION The METS E-106 is designed to pump silver bearing liquid through two metallic replacement cartridges. The METS metering pump controls the flow rate (factory set at 100 mls/minute) to ensure the maximum amount of silver is recovered. The METS unit is ideal for minilabs, allowing them to meet though environmental regulations for silver of 1mg/L (1 ppm) or less when used with RePAC 250 steel wool cartridges. Capacity performance will depend on silver concentration, flow rate, solutions composition and ph (which must be below 7.8). These simple to operate units are easy to install and monitor. INSTALLATION The METS E-106 unit was designed to be installed under most darkroom sinks, plumbed with a quick dump box. Refer to the typical under the sink installation drawing below. Only fix and pre-rinse water can be poured into the METS E-106 (not continuous wash water). NOTE: DO NOT RUN DEVELOPER THROUGH THE METS UNIT! 4

OPERATION BIG-MO cartridges are recommended for METS E-106 units. They can be ordered from CPAC at 800-828-6011. When using these cartridges, a flow rate of 100 ml/minute is used. The first cartridge should be changed after treating 500 gallons (based upon a starting concentration of 1.8 gm/l). This is equivalent to 315 hours of operation. If your silver discharge limit is 5mg/L (ppm), the cartridges may sustain a longer operating period. For safety reasons, the METS E-106 unit is equipped with a 6 PSI pressure relief valve. Pump flow rate is factory set at 100 ml/minute. If an adjustment is necessary, refer to BELLOWS PUMP FLOW ADJUSTING instructions. For optimal performance and efficiency, the paper bleach-fix (and washless stabilizer) and film fixer (& washless stabilizer) should be drained into the METS collection tank together. This allows a uniform solution to be treated. METS units plumbed directly to the processor will automatically receive this mixture. Weekly Maintenance Procedure EXTREMELY IMPORTANT! Run two to three gallons of warm (or hot) water through the unit once a week by pouring water into the holding tank. This reduces build-up in the cartridges, lines and quick disconnects. Control Box Power A green LED illuminates when the METS E-112 unit is plugged in. Overflow An audible alarm is constant when an overflow condition exists. When this alarm sounds do not add solution to the holding tank. Circuit Breaker A circuit breaker is located on the control box to protect against electrical overloads. 5

How to Change a METS-E106 Cartridge 1. Fill the holding tank of the METS E-106 unit. 2. Allow all the water to pump through the cartridges (2 gallons will take 1 ¼ hours). 3. Turn off the power by using the CRT BRK button on the control box. 4. Remove the new cartridge from the shipping container. DO NOT THROW AWAY THE BOX. 5. Using the quick disconnect fittings on the cartridges, remove cartridge #1 from the machine. Set aside for draining. 6. Move cartridge #2 to the #1 position and reconnect the unit s quick disconnect fitting to the bottom of the cartridge. 7. Place the new cartridge in the #2 position and connect top fitting of #1 to bottom fitting of #2 cartridge. 8. Connect top fitting of #2 cartridge to drain or waste tank. 9. Turn machine on. Pour four gallons of water in the holding tank. 6

DRAINING METS CARTRIDGE FOR SHIPPING The draining procedure does not interfere with the operation of the METS unit. Once a cartridge is drained, it cannot be reused (refer to drawing below). 1. Place cartridge just removed in a convenient area to drain the liquid into a plastic bucket or container. 2. Connect the matching quick disconnect fitting into the quick disconnect fittings installed on the cartridge. 3. Place the lower hose into a plastic bucket or container. 4. Allow the cartridge to drain completely (approximately one or two hours). 5. Remove insert fitting from top disconnect on cartridge being drained. 6. Disconnect bottom fitting from cartridge drain fitting on METS E-106 unit. FOLLOW THE PROVIDED INSTRUCTIONS FOR SHIPPING. IF YOU HAVE ANY QUESTIONS OR CONCERNS PLEASE CALL 800-828-6011. POPPET VALVE REMOVAL, CLEANING AND INSTALLATION PROCEDURES 1. Pinch off tubes near the pump s connectors. 2. Unscrew connector nuts, pull off tubing and nut connector assemblies. 3. Remove valves from valve body; a) Suction side Pull valve out by the stem, the O-ring will come out with the valve. b) Discharge side Use a small flat screwdriver to remove the o-ring. With o-ring removed, pull valve out of the valve body with needle nosed pliers. 4. Wash poppet valve assemblies or discard and replace. 5. Reinstall in reverse order of removal. Suction and discharge valves are interchangeable. Valves are always installed before o-ring. 7

8

BELLOWS PUMP FLOW ADJUSTING INSTRUCTIONS 1. Do not attempt to adjust flow while pump is running. 2. Clockwise rotation of the adjusting screw increases pump stroke until achieving 100% stroke. Do not attempt forced rotation of the adjusting screw after indicator reaches 100% and a bottoming resistance is experienced. 3. Counter-clockwise rotation of adjusting screw decreases stroke. 4. Only eight clockwise revolutions adjust stroke from 0% to 100%. One-half inch bellows pump requires only four revolutions. 5. It is not necessary to loosen set screw. NOTE: Do not add lubricants to any pump mechanism. 9

FOR BEST PERFORMANCE AND EFFICIENCY, THE PAPER BLEACH-FIX (AND WASHLESS STABILIZER) AND FILM FIXER (AND WASHLESS STABILIZER) SHOULD BE DRAINED INTO THE METS COLLECTION TANK TOGETHER. THIS ALLOWS A UNIFORM SOLUTION TO BE TREATED. METS UNITS PLUMBED DIRECTLY TO THE METS UNITS WILL AUTOMATICALLY RECEIVE THIS MIXTURE. EVERY EFFORT HAS BEEN MADE TO INSURE THE COMPLETE ACCURACY OF THE CONTENTS OF THIS MANUAL. NO LIABILITY ARISING FORM ITS USE, HOWEVER, CAN BE ACCEPTED BY THE COMPANY, WHO RESERVES THE RIGHT, WITHOUT PRIOR NOTICE, TO ALTER THE SPECIFICATIONS, CONSTRUCTION, OR CONTENT OF ITS EQUIPMENT AT THE COMPANY S OWN DISCRETION. Statement of Warranty All equipment is manufactured to exacting standards and has been tested and inspected for proper workmanship and performance before shipping. Any parts which are defective will be repaired or replaced within a one year period after date of shipment, provided the equipment has been used according to the instruction manual and have not been abused or tampered with. The company will not be responsible for any damage resulting from leakage of water or chemicals caused by improper installation, operator carelessness or defective/loose plumbing fittings associated with installation and operation of the equipment. The company assumes no responsibility for damage in transit and the customer should resent any claim for such damage to the carrier. This warranty gives you specific legal rights. You may also have additional rights that vary from state to state. Any unit to be repaired under warranty must be shipped, freight prepaid, or delivered to a facility authorized to render services provided hereunder. Returned unit must be either in its original package or a similar package affording an equal degree of protection. All units must have a Return Material Authorization code (RMA) visible on the returned item. RMA s can be obtained by calling 585-382-3223. 10