APS-Series 1500VDC OUTDOOR SOLAR INVERTER

Similar documents
APS-Series 1000VDC OUTDOOR SOLAR INVERTER

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Incident resolution workflow

EON TM. 10 kw - 55 kw THREE PHASE. Centralized Emergency Lighting Inverters MODEL EL3

Get connected with Xantrex Grid-Tie Inverters

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

PHOTOVOLTAIC HEAT CONTROLER PVHC 2.01 USER MANUAL

AC THOR. Assembly Instructions

Instructions for the fan motor control system, SILVER C

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

» EN50171» Lighting» Reliable

Symmetra MW Modbus Data Points

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Installation, Operating and Maintenance Manual

For Complete Fire and Gas Solutions

TPF Series Ozone Generators

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Quality assurance and safety aspects. Dipl.Ing. Udo Siegfriedt DGS-Berlin Brandenburg

Multi-Gas-Controller MGC2

LORAIN CIP 4890/48120 DC Power System

User instructions and quick-fit guide

DANFOSS OPTYMA PLUS INVERTER UNITS

Ozonated Water System

Dust Alert 75. *shown with optional external keypad and display

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

PART 4 ELECTRICAL STANDARDS

Rittal roof-mounted fans Efficiency on top

On the job around the clock 24/7: Fire detection systems

SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature F Humidity < 80 % Gas and Noxious Vapors

APPLICATION DATA SHEET

PLW PLW TOP LOAD. PV Hot Water Controller. PV Solar Hot Water Controller PLASMATRONICS. Manual. Read this before installing. Rev. U3.

Power Plants with Webel Solar Modules

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Advance Split

and 4 alarm extensions provide system conditions. The controller can be accessed through the front panel craft port or optional modem connectivity.

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Instruction Manual (Supplementary) Open Type Inverter

Billion Watts Technologies. Professional Solar Monitoring & Management System

Electronic timeswitch

LORAIN CSP DC Power System

Installation Instructions CS3 Three Phase Solid State Relay

Safety Instrumented Fire & Gas Systems

EFBW series - BiWire Ultra control panel

Dissolved Oxygen Analyzers

Excel-EN Conventional Fire Control Panel

DEKO 260 Washer - Disinfector - Dryer

UltraLITE. Centralized Emergency Lighting Inverters MODEL ELU

Temperature Control Systems

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

SECTION SOLAR PHOTOVOLTAIC (PV) POWER GENERATION SYSTEM

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

MODULAR TRACTION SUBSTATIONS CITY ELECTRIC TRANSPORT

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Off-Grid CyboInverter Installation Guide. For CI-Mini-1200H Solar Mini-Inverter for Electric Water Heaters

Safety Cabinets / Width 1200 mm / 2 Doors. Height 1968 and 1298 mm Height 1968 mm Height 1968 mm. Folding door. Type 90. Type 30

Use. For 2-pipe fan coils

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

TRACENET TM TN SERIES

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

General safety precautions English

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

RE-PR3-E-27 3-Phase Panel Mount 27kW

APC BC300 Series 40kW 208/450/480V User Guide

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Smoke Vent Control Panel PCB4 V4 Installation Manual

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

User Manual. Power Distribution Unit. Version: 1.0

Home Energy Management (Device Control): Immersion Heater Controller Use Cases, Application Note

Room Temperature Controllers

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

Intelligent addressable fire alarm control panel

Gas Controller Module GC-06

Product Line Introduction. Karl Zhang Technical support engineer

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

Passive Cooling Systems Air Conditioning Without the Need of Energy

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

IT system floor-standing distribution

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

APPLICATION DATA SHEET

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Excellent performance with low operating costs, Energy saving and environmentally friendly

Central Emergency Lighting Inverter Systems

Aquaflair TRAC-TRAF-TRAH

PRODUCT DATA SHEET. Models ASDCA/HSDCA & ASDCHA

Smart Series TAS-05-11, TAS-05-12

Light Support Power Systems CENTRAL EMERGENCY LIGHTING INVERTER SYSTEMS

elite TM SERIES Centralized Emergency Lighting Inverters MODEL ELE

PowerWizard Range. Digital Control Systems & Remote Communication Options. PowerWizard Providing Safe Control of Your.

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

PowerWave 2 Busway System

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Transcription:

OUTDOOR SOLAR INVERTER The APS-Series are outdoor PV central inverters for large PV fields with voltages up to 1500 VDC. The APS-Series is a plug and play solution for your installations. It includes all necessary parts: IP65 outdoor cabinet made for desert installations cooling system with heat exchanger o o automatic cleaning function of the water to air heat exchanger Easy to clean air to air heat exchanger with no filter mats internal maintenance free air dryer to avoid corrosion AC circuit breaker fuse protected DC combiner optionally with current monitoring DC coupling in case of an inverter fault Modbus TCP or Real Ethernet communication interfaces Hybrid System for Solar and Storage (connect PV and batteries at different dc inputs) The cabinet is completely closed. By the aid of an air to air heat exchanger the cabinet is cooled, a water cooling circuit is used for the IGBTs and inductances. With this cooling concept the APS-Series is very robust against dust and moisture. The APS-Series is supplied with all necessary control systems. In standard an optical MODBUS TCP interface is installed, optionally a PC-based monitoring system can be integrated.

Electrical Data TECHNICAL DATA Product APS1500 APS2250 APS 3000 APS4500 Maximum AC-power 1500 kva 2250 kva 3000 kva 4500 kva at rated grid voltage Rated AC-power 1500 kw 2250 kw 3000 kw 4500 kw cos ϕ = 1.0 Rated grid voltage 550 V, 3-phase, 50 Hz/60 Hz Other values on request Max. short circuit level 50 ka Maximum AC-current 2 x 787 A 3 x 787 A 4 x 787 A 6 x 787 A Line power factor (cos φ) > 0.98 > 20 % of rated power AC-current distortion (THD) < 3 % Rated PV-power 2 764 kw 3 764 kw 4 764 kw 6 764 kw Maximum PV-current 2 849 A 3 849 A 4 849 A 6 849 A Maximum PV power unlimited limited by max. AC power Maximum PV no-load-voltage 1500 VDC Number of MPPTs 2 3 4 6 MPP-range 900 VDC...1320 VDC at rated PV-power Control strategy Maximum-power-point tracking CCCV if battery connected Efficiency in % 97.8 98.4 98.4 98.3 98.2 97.9 98.4 98.4 98.3 98.2 97.9 98.4 98.4 98.3 98.2 97.9 98.4 98.4 98.3 98.2 at (10 30 50 75 100) % power EU efficiency 98.3 % 98.3 % 98.3 % 98.3 % including all inverter losses Feed-in starting at 400 W 600 W 800 W 1200 W Standby losses (at night) 90 W 140 W 150 W 200 W Maximum auxiliary power < 2000 W < 3500 W < 3500 W < 5000 W + heating power

General Data Product APS1500 APS2250 APS3000 APS4500 Ambient temperature -10 C...60 C (32 F...140 F) Others on request. Maximum altitude 1500 m above sea level without derating in power Cooling type Forced air and water cooling Protection class IP65 Dimensions (L W H) 1860 1142 3468 3503 1142 3468 5054 1142 3468 in mm Weight < 1900 kg <2900 kg <3400 kg < 4500 kg Shelter surface Painted Colour RAL7035 Different colours on request. EMI Complies EN61000-6-2, EN61000-6-4 Medium voltage directive BDEW CE-conformity Complies Features DC disconnector Separately secured DC-inputs Air dehumidifier inside the shelter AC circuit breaker Low voltage ride-trough (LVRT) handling Surge arresters with monitoring on DC-side Earth leakage monitor Status displays in the shelter Surge arresters with monitoring on AC-side External heat exchanger for dusty/moist ambient and extreme climatic conditions Options Positive or negative earthing of solar field DC-Inputs and control for energy storage (battery) Heating for inverter section Measuring and monitoring of single input currents Industrial PC and monitor

TECHNICAL DATA EFFICIENCY

TECHNICAL DATA - DERATING

TECHNICAL DATA - DIMENSIONS

TECHNICAL DATA INTERNAL VIEWS Number Component 1 Water to air heat exchanger 2 Air to air heat exchanger 3 Control cabinet 4 touch display (HMI) 5 Power stack with IGBTs 6 Inductances 7 AC-Circuit breaker 8 Water pump 9 AC-connection to transformer