LAPP GROUP NORTH AMERICA CABLE ATTRIBUTES QUICK GUIDE

Similar documents
MORE VALUE MORE BENEFITS MORE THAN YOU IMAGINE ÖLFLEX TRAY II ÖLFLEX TRAY II CY

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

Flame Retardant Polyethylene Tubing

Pneumatic Tubing POLYTUBING O.D. 5/32"

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Nuclear Power Plant LSZH Cable Overview

DNVGL-CP-0402 Edition February 2016

FieldLink Cable solutions for Automation & Drives

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Fiber Optic Distribution Cables (6-144 Fibers)

North America Regulatory & Safety Standard Agencies

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

UL 94 Flammability Ratings: Introduction

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement

fire resistant cables

Brand Portable Power Cord & Control Cable Solutions

Cat 6 Unshielded Patch cords

WIRE & CABLE SOLUTIONS

Flexible Power Cable DLO

A Look at General Cable s GenFree II Product Line

HELKAMA. Optical Fibre Cables

/Oct/2014 Rev E

Cat 6 Shielded Patch cords

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

STANDARD FOR INDOOR-OUTDOOR OPTICAL FIBER CABLE

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

The Quality Connection. BETAflam Fire Resistant Safety Cables

Photovoltaic Cables EN H1Z2Z2-K

DualGuard Fluoropolymer Barrier FRP Duct. Composites USA. Fluoropolymer Barrier FRP Duct. A Critical Process Systems Group Company LISTED

PERFORMANCE POLYMER SOLUTIONS

Tech Notes. TESTING PROTOCOL Fire Retardant Gel Coats. INTERPLASTIC CORPORATION Thermoset Resins Divison ISSUE 5

CONNECTION SYSTEMS TRANSIT APPLICATIONS

FM Approval Standard For Cavity Walls And Rainscreens

Belden Infinity C-TC+ Cables for Extreme Flexing

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

/Oct/2014 Rev B

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Market-Leading Non-Metallic Enclosure Brands

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Pasto Sous vide water bath

Firestone Reinforced Polypropylene (fpp-r) Geomembrane

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

industry solutions: military

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

CATALOG LIQUID-TUFF FLEXIBLE LIQUIDTIGHT CONDUIT CATALOG. Industrial & Commercial Liquidtight Conduit Flexible Metal Conduit A PART OF

speed pipe indoor system. Secure indoor networks.

Duct Cable GYTS-144B1.3

Oberon s NEC Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

EUTECTIC EC-10DV Series

Public Comment No. 1-NFPA [ Section No ]

CAN THE CONE CALORIMETER BE USED TO PREDICT FULL SCALE HEAT AND SMOKE RELEASE CABLE TRAY RESULTS FROM A FULL SCALE TEST PROTOCOL?

Oberon s National Electric Code (NEC)Compliance Statement and Underwriters Laboratories (UL ) Considerations for Oberon Products

Jul07 Rev C

D U R ETHAN AND POCAN F OR THE ELECTRI CAL IN D U STRY N EW HALOGE N-FRE E FLAME-RETARDANT

WIRE & CABLE GEON CONNECTED SOLUTIONS

STANDARD CONFORMANCE

Navigating the Safety Certification Process for LED Lighting Products Todd Straka, Director Lighting Services

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Thermocouple Cable TRANSMITTING, SENSING, MEASURING

Wiring Duct Product Selection Guide

G4 Pulsed Fiber Laser

Tyco Electronics Solar Identification Labels

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Second Revision No. 601 NFPA [ Section No [Excluding

EU RO Mutual Recognition Technical Requirements

Fire Performance of Translucent Systems

HOOK-UP AND LEAD WIRE. UL: 3284, Non VW-1 CSA: AWM I A/B, CL-1254, FT-2. AWG Size. Number of Strands. Note: AWG 20 is available upon request.

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

DNVGL-CP-0401 Edition February 2016

Fire Testing of Foams

Approval Standard for Electric Equipment for use in Hazardous (Classified) Locations General Requirements

Qualification Test Report LC Duplex Adapter For LC Cutouts

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Amerex Clean Agent System with FM200. Potential Applications: System Coverage Overview: Approvals and Standards:

Custom-designed and standard Multiconductor (Multicore) Cables

Class 1E Cable Qualification to the Latest IEEE Standards

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Determination of Fire Exposure Heat Flux in Cable Fire Tests

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Cable Ties JULY The electronic pdf version of this document found through is the officially binding version

Tyco Thermal Controls provides complete heat tracing and speciality. wiring solutions for the industrial, commercial, and residential markets.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Are Your Kitchen Hood Filters Compliant?

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

INTERNATIONAL STANDARD

Transcription:

LAPP GROUP NORTH AMERICA CABLE ATTRIBUTES QUICK GUIDE

LAPP User Guide Through continual Research & Development and the extensive knowledge of our engineers; the Lapp Group has developed criteria which will aid the cable user in deciding which cable is best suited to application needs. As you will find on the following pages, the Lap Group has brought cable specifying to a new level for the following product attributes: Oil Resistance, Flame Resistance, Motion Types, and Mechanical Properties. By setting the criteria for such important attributes, our engineers have given the cable buyer a more precise and definitive way to choose the cable that s right for their specific application or environment. To help you choose the Lapp cable that best suits your requirements, we suggest you review the criteria and definitions on the following pages and familiarize yourself with the different levels. The Lapp Group will strive to continue to provide creative solutions and the highest quality products you ve come to expect.

Oil Resistance The type of industrial environment and other factors such as the duration of oil exposure and quantity of the liquid all attribute to the specific level of oil protection needed. Other parameters such as the surrounding ambient, temperature of the oil and the cable itself will also play a role in determining the cables ability to withstand this type of chemical exposure. In general, the greater the ability of the cable jacket to resist the possible devastating effects of oil, the longer it will perform uninterrupted in the application. Certain industries (grinding, machine tools, painting, etc.) will require the highest degree of oil resistance available, while other applications (office buildings, residential dwellings, etc.) will only need a minimal amount of this type of protection. The Lapp Group provides a large product offering of cables in a wide array of different construction that will meet varying degrees of oil resistance required for your application. Level USA CSA* Europe* OR-00 No oil resistance characteristics OR-01 UL 62 One week test In oil for 7 days @ 60 C 75% Unaged Tensile Strength 75% Unaged Elongation C22.2 No. 49 In oil for 7 days @ 60 C 75% Unaged Tensile Strength 75% Unaged Elongation VDE 0281 Part 1 In oil for 7 days @ 60 C +/- 30% Unaged Tensile Strength +/- 30% Unaged Elongation OR-02 UL Oil Res. I In oil for 4 days @ 100 C 50% Unaged Tensile Strength 50% Unaged Elongation C22.2 No. 230 In oil for 4 days @ 100 C 50% Unaged Tensile Strength 50% Unaged Elongation VDE 0472 Sect. 803A In oil for 1 day @ 100 C +/- 25% Unaged Tensile Strength +/- 25% Unaged Elongation OR-03 UL Oil Res. II In oil for 60 days @ 75 C 65% Unaged Tensile Strength 65% Unaged Elongation C22.2 No. 210.2 In oil for 4 days @ 100 C 65% Unaged Tensile Strength 65% Unaged Elongation SEV TP 20 B In oil for 30 days @ 70 C No cracking after bending OR-04 UL AWM 21098 In oil for 60 days @ 80 C 65% Unaged Tensile Strength 65% Unaged Elongation C22.2 No. 0.3 In oil for 60 days @ 80 C 65% Unaged Tensile Strength 65% Unaged Elongation VDE 0472 Sect. 803B In oil for 7 days @ 90 C +/- 25% Unaged Tensile Strength +/- 25% Unaged Elongation OR-05 In oil for 3 Weeks @ 100 C 100% Unaged Tensile Strength 110% Unaged Elongation OR-06 In oil for 7 days @ 180 C 80% Unaged Tensile Strength 60% Unaged Elongation *Note: These oil immersion standards are mentioned for the sole purpose of reference. Some Canadian and European test standards are not necessarily represented here as complete equivalents to the US standards but have been referenced due to similarities in requirements. Refer to the individual standards for detailed test procedures and any comparable evaluations.

Fire Resistance Lapp cables are manufactured to comply with varying degrees of flame resistance requirements. Depending upon your application, certain levels of flame resistance are necessary in order to meet specific end use requirements. Flammability ratings generally determine the end use application, which is generally dictated by local or national electrical codes. Certain applications require a minimal amount of flame resistance such as UL 62 or CSA FT2 for flexible cordage. In this instance, the end use of these products do not deem the necessity of imposing a high flammability requirement. Other applications such as cables that will be installed permanently within an industrial building, commercial dwelling, or family residence will most likely require a higher degree of flammability resistance such as UL Vertical Tray or CSA FT4. Whatever the end use application, the Lapp Group offers a wide variety of cable products meeting different levels of flame resistance to meet your requirements. Level USA CSA* Europe* FR-00 FR-01 Little or no flame retardancy, cable ignites and burns easily, and will not extinguish itself. UL 62 Horizontal Flame test One 30 second flame application Must not emit flame or glowing particles FT2 : One 30 second flame application Must not emit flame or glowing particles VDE 0472 Part 804 One 1-minute flame application Must not ignite or emit flames FR-02 UL VW-1 (UL 1581): Vertical Flame test with Bunsen burner Five 15 second flame applications Must not emit flame or glowing particles FT1: Vertical flame test Five 15 second flame applications Must not emit flame or glowing particles IEC 60332-1: Flame application time varies by cable diameter Must self-extinguish FR-03 UL 1581: 70,000 BTU Vertical Tray test Damage cannot exceed 8 feet FT4: Vertical Tray test Damage cannot exceed 5 feet IEC 60332-3-24 Damage cannot exceed 8.2 feet FR-03.1 UL Vertical Tray Fire Propagation Damage cannot exceed 8 ft. Smoke release not to exceed 95m² FT4-ST1: Vertical Tray Fire Propagation Damage cannot exceed 8 feet Smoke release not to exceed 95m² IEC 60332-3-25 Exposed flame for 20 min. Damage cannot exceed 8.2 feet FR-04 UL 1666: 527,500 BTU Flame test for Riser cables Flame spread cannot exceed 12 ft. Measured temperature at any point cannot be greater than 850 F FR-05 UL 910: 300,000 BTU Flame test for Plenum cables Damage cannot exceed 5 ft. Peak smoke optical density not to exceed 0.50 FT6: Damage cannot exceed 5 ft, Peak smoke optical density not to exceed 0.50 IEC 61034-2: Exposed to flame for a maximum of 40 min. Minimum value of 60% light transmittance *Note: These flame standards are mentioned for purposes of reference only. Some Canadian and European test standards are not necessarily represented here ad complete equivalents to the US Standards but have been referenced due to some similarities in requirements. Refer to the individual standards for detailed test procedures and any comparable evaluations.

Motion Resistance The Lapp Group s cable designs are evaluated under the most extreme test conditions. The cycle life testing ranges mentioned above do not indicate cable flex cycle failure, but is only an indicator of suggested range for the intended application. When Lapp continuous flex cables are installed correctly in the application, a longer service life will result. For almost half a century, Lapp products have been expertly designed, processed and manufactured with state of the art equipment, guaranteeing the finest flexible cable products available. Our credibility and expertise have classified Lapp as the innovator in the industrial flexible cable and robotic industry. Level Description Definition Cycle Life Range* FL-00 Very stiff (Static) Low strand count and difficult to work with, used in static applications FL-01 Flexible FL-02 Highly Flexible CF-01 Continuous Moderate Flexing CF-02 Continuous High Flexing CF-03 Continuous High Flexing Can be easily installed in machines, conduit and cable tray when applicable High flexibility with continuous flexing design attributes Designed for continuous flexing and cable track applications Applications - Chain length up to 300 ft. Designed for High Cycle Continuous Flexing and Long Cable Track Applications - Chain length up to 30 ft. Designed for High Cycle Continuous Flexing and Long Cable Track Applications - Chain length up to 300 ft. 2-8 million 8-20 million 8-20 million T-01 Torsion Designed to withstand Torsion applications 2 million TCF-01 Torsion & Continuous Flex Designed for High Cycle Continuous Flexing and Torsion applications 10 million *When comparing cycle life data between cables, the following critical variables must be evaluated.

Flex Life Testing Parameters Test Conditions for Continuous Flex Cables Minimum Bend Radius Range Factor Bending Radius Range Factor During Testing Travel Distance Under Test Conditions Acceleration Under Test Conditions 5.0-15.0 x Cable Diameter 4.0-12.0 x Cable Diameter 18 Feet Varies up to 26 Feet per second Temperature Range During Test 10 C to 22 C Speed of Travel During Test Varies from 6.5 to 13 Feet per second Test Conditions for Torsion Cables Standard Torsion Stress Severe Torsion Stress Bending Radius Range Factor During Test ± 450 / 1 meter ± 450 / 0.5 meters 10.0-12 x Cable diameter

Mechanical Depending upon the specific application, a cable may be exposed to external factors and various types of abuse. The explicit type of industrial manufacturing and processing environment will determine the actual degree of mechanical protection that a cable requires. CNC machine centers, Mining, Food and Beverage plants, Automotive Assembly facilities, Machine tools, Data Processing, Automation, etc. applications all requiring a certain level of mechanical protection. The unintentional mishaps that occur everyday during routine manufacturing can range anywhere from a cable being struck by a falling object Level Description Impact Crush Cold Impact Tensile Elongation Standard MP-00 No extra-mechanical resistance properties MP-01 Average * * 1500 Psi 100% ASTM D-412 MP-02 Good - Independent lab tested for crush & impact. 10/50 Lbs. 1000/2000 Lbf. 1700 Psi 175% UL 1277 ASTM D-412 MP-03 Very good - Rated for Exposed Run use (-ER) 10/50 Lbs. 2000/4000 Lbf. 25 C (CSA-TC) 2300 Psi 275% UL 1277 ASTM D-412 MP-03.1 Very good - Rated for Exposed Run use (-ER) 10/50 Lbs. 2000/4000 Lbf. 40 C (CSA-TC) 2300 Psi 275% UL 1277 ASTM D-412 MP-04 Excellent ** ** 3400 Psi 325% ASTM D-1457 MP-05 Superior ** ** 4200 Psi 500% ASTM D-412 * Impact and Crush tests not applicable for intended end use of product ** Testing not required, however, if tested, these groups would meet or exceed UL 1277 Impact and Crush requirements by virtue of their superior mechanical properties.

ÖLFLEX Power and Control Cables SKINTOP Cable Glands SILVYN Conduit ETHERLINE Industrial Ethernet EPIC Connectors UNITRONIC Data Cables FLEXIMARK Marking Systems HITRONIC Fiber Optic Cables LAPP USA 29 Hanover Road Florham Park, NJ 07932 800-774-3539 www.lappusa.com LAPP CANADA 3505 Laird Road, Unit 10 Mississauga, Ontario L5L 5Y7 877-799-5277 www.lappcanada.com LAPP MEXICO Metalurgia 2730 Alamo Industrial, C.P. 44490 800-024-5277 www.lappmexico.com