Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Similar documents
TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION FIRE EXTINGUISHER CABINETS

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

Shop Drawings: For fire protection cabiaets, lnclode plans, elevations, sections, details, and attachments to other work.

DIVISION 10 SPECIALTIES

ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for detention furniture.

A. Provide products and workmanship in accordance to: (Where applicable)

B. Product Schedule: For appliances. Use same designations indicated on Drawings.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

Consult the manufacturer for assistance in editing this guide specification for specific Project applications where necessary.

1. Vinyl wall covering. 2. Woven glass-fiber wall covering. 3. Textile wall covering. 4. Wallpaper. 5. Heavy-duty, synthetic, textile wall covering.

A. Section includes ground-mounted flagpoles made from aluminum.

University of Missouri St. Louis UMSL Project #S7628 Campus Police Building Building Modifications & Renovations R&B Project # Building Upgrades

GUIDE SPECIFICATION Los Angeles World Airports SECTION TOILET COMPARTMENTS

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories for each type of product indicated.

EXAMPLE SPECIFICATION ONLY

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Hinesville First United Methodist Church SECTION RESIDENTIAL APPLIANCES

Springpoint Architects, pc SECTION Childcare Center Architect s Project No TABLE OF CONTENTS Monroe County Comm. Sch. Corp.

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

University of Rochester October 17, 2008 Brooks Landing Business Center

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

SECTION Overhead Coiling Doors

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

A. This Section includes the following emergency plumbing fixtures:

HOW TO SELECT CABINETS

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

SECTION DRY-PIPE SPRINKLER SYSTEMS

B. Shop Drawings: Details of electrified door hardware, including wiring diagrams.

ONONDAGA COMMUNITY COLLEGE FERRANTE HALL RENOVATIONS - PHASE

SECTION GYPSUM PLASTER

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SECTION FIRE-RATED GLASS AND FRAME

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

WALLCOVERINGS WALLCOVERINGS

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

B. Shop Drawings: Include diagrams for power, signal, and control wiring.

Product Guide Specification

ASI Guide Specification

TRUMAN STATE UNIVERSITY PRESIDENT S RESIDENCE RENOVATION

RESIDENTIAL APPLIANCES DIVISION 11 - EQUIPMENT PN A

Construction Standards Page

Richmond Hill Primary Renovation SECTION STAGE CURTAINS

PART 1 GENERAL 1.01 SUMMARY

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

SECTION AIR DUCT ACCESSORIES

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

SECTION ELECTRIC WATER HEATERS

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

SECTION AIR COILS

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

c. Oko-Tex (European environmental health standard)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

Element C Interiors Interior Construction

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

SECTION DRY-PIPE SPRINKLER SYSTEMS

SECTION DOOR HARDWARE

UNIFIED FACILITIES GUIDE SPECIFICATIONS

B. Manufacturer s color charts consisting of actual units or section of units showing the full range of colors available for the following:

Vanilla Box Design Criteria

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

ARBOR SERIES DIVISION FLEXIBLE WOOD VENEER WALLCOVERING

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

A. Curtains: Provide curtain fabrics with the following characteristics:

A. Section Includes: Fire extinguishers and cabinets including necessary accessories.

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers.

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

SECTION (15767) - UNIT HEATERS

Product Guide Specification

About the Instructor & Presenter:

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

SECTION COMMERCIAL-KITCHEN HOODS

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

ARCHITECTURAL SPECIFICATIONS

Transcription:

SECTION 104413 - FIRE PROTECTION CABINETS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Fire-protection cabinets for the following: a. Portable fire extinguishers. B. Related Requirements: 1. Section 104416 "Fire Extinguishers." 1.3 ACTION SUBMITTALS A. Product Data: For each type of product. Show door hardware, cabinet type, trim style, and panel style. Include roughing-in dimensions and details showing recessed-, semirecessed-, or surfacemounting method and relationships of box and trim to surrounding construction. B. Shop Drawings: For fire-protection cabinets. Include plans, elevations, sections, details, and attachments to other work. C. Samples: For each type of exposed finish required. D. Samples for Initial Selection: For each type of exposed finish required. E. Samples for Verification: For each type of exposed finish required, prepared on Samples 6 by 6 inches (150 by 150 mm) square. F. Product Schedule: For fire-protection cabinets. Indicate whether recessed, semirecessed, or surface mounted. Coordinate final fire-protection cabinet schedule with fire-extinguisher schedule to ensure proper fit and function. 1.4 CLOSEOUT SUBMITTALS A. Maintenance Data: For fire-protection cabinets to include in maintenance manuals. FIRE PROTECTION CABINETS 104413-1

1.5 COORDINATION A. Coordinate size of fire-protection cabinets to ensure that type and capacity of fire extinguishers indicated are accommodated. B. Coordinate sizes and locations of fire-protection cabinets with wall depths. 1.6 SEQUENCING A. Apply decals on field-painted fire-protection cabinets after painting is complete. PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. Fire-Rated Fire-Protection Cabinets: Listed and labeled to comply with requirements in ASTM E 814 for fire-resistance rating of walls where they are installed. B. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. 2.2 FIRE-PROTECTION CABINET FEC A. Cabinet Type: Suitable for fire extinguisher. 1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to the following: a. Babcock-Davis. b. GMR International Equipment Corporation. c. Guardian Fire Equipment, Inc. B. Cabinet Construction: Nonrated. 1. Fire-Rated Cabinets: Construct fire-rated cabinets with double walls fabricated from 0.043-inch- (1.09-mm-) thick cold-rolled steel sheet lined with minimum 5/8-inch- (16- mm-) thick fire-barrier material. Provide factory-drilled mounting holes. C. Cabinet Material: Cold-rolled steel sheet. D. Semirecessed Cabinet: One-piece combination trim and perimeter door frame overlapping surrounding wall surface with exposed trim face and wall return at outer edge (backbend). 1. Square-Edge Trim: 1-1/4- to 1-1/2-inch (32- to 38-mm) backbend depth. FIRE PROTECTION CABINETS 104413-2

E. Cabinet Trim Material: Steel sheet. F. Door Material: Steel sheet. G. Door Style: Fully glazed, frameless, backless, acrylic panel. 1. Acrylic Sheet Color: Clear transparent acrylic sheet. H. Door Hardware: Manufacturer's standard door-operating hardware of proper type for cabinet type, trim style, and door material and style indicated. 1. Provide. 2. Provide manufacturer's standard hinge permitting door to open 180 degrees. I. Accessories: 1. Mounting Bracket: Manufacturer's standard steel, designed to secure fire extinguisher to fire-protection cabinet, of sizes required for types and capacities of fire extinguishers indicated, with plated or baked-enamel finish. 2. Lettered Door Handle: One-piece, cast-iron door handle with the word "FIRE" embossed into face. 3. Door Lock: Cam lock that allows door to be opened during emergency by pulling sharply on door handle. 4. Identification: Lettering complying with authorities having jurisdiction for letter style, size, spacing, and location. Locate as directed by Architect. J. Materials: a. Identify fire extinguisher in fire-protection cabinet with the words "FIRE EXTINGUISHER." 1) Location: Applied to cabinet door. 2) Application Process: Decals. 3) Lettering Color: White. 4) Orientation: Horizontal. 1. Cold-Rolled Steel: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B. a. Finish: Factory primed for field painting. b. Color: As selected by Architect from full range of industry colors and color densities. 2. Transparent Acrylic Sheet: ASTM D 4802, Category A-1 (cell-cast sheet), 1.5 mm thick, with Finish 1 (smooth or polished). 2.3 FABRICATION A. Fire-Protection Cabinets: Provide manufacturer's standard box (tub) with trim, frame, door, and hardware to suit cabinet type, trim style, and door style indicated. FIRE PROTECTION CABINETS 104413-3

1. Weld joints and grind smooth. 2. Provide factory-drilled mounting holes. B. Cabinet Doors: Fabricate doors according to manufacturer's standards, from materials indicated and coordinated with cabinet types and trim styles. 1. Fabricate door frames with tubular stiles and rails and hollow-metal design, minimum 1/2 inch (13 mm) thick. 2. Fabricate door frames of one-piece construction with edges flanged. 3. Miter and weld perimeter door frames. C. Cabinet Trim: Fabricate cabinet trim in one piece with corners mitered, welded, and ground smooth. 2.4 GENERAL FINISH REQUIREMENTS A. Comply with NAAMM's AMP 500, "Metal Finishes Manual for Architectural and Metal Products," for recommendations for applying and designating finishes. B. Protect mechanical finishes on exposed surfaces of fire-protection cabinets from damage by applying a strippable, temporary protective covering before shipping. C. Finish fire-protection cabinets after assembly. D. Appearance of Finished Work: Noticeable variations in same piece are not acceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine walls and partitions for suitable framing depth and blocking where semirecessed cabinets will be installed. B. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 PREPARATION A. Prepare recesses for semirecessed fire-protection cabinets as required by type and size of cabinet and trim style. FIRE PROTECTION CABINETS 104413-4

3.3 INSTALLATION A. General: Install fire-protection cabinets in locations and at mounting heights indicated or, if not indicated, at heights indicated below: 1. Fire-Protection Cabinets: 54 inches (1372 mm) above finished floor to top of cabinet. B. Fire-Protection Cabinets: Fasten cabinets to structure, square and plumb. 1. Unless otherwise indicated, provide recessed fire-protection cabinets. If wall thickness is inadequate for recessed cabinets, provide semirecessed fire-protection cabinets. 2. Provide inside latch and lock for break-glass panels. 3. Fasten mounting brackets to inside surface of fire-protection cabinets, square and plumb. C. Identification: Apply decals at locations indicated. 3.4 ADJUSTING AND CLEANING A. Remove temporary protective coverings and strippable films, if any, as fire-protection cabinets are installed unless otherwise indicated in manufacturer's written installation instructions. B. Adjust fire-protection cabinet doors to operate easily without binding. Verify that integral locking devices operate properly. C. On completion of fire-protection cabinet installation, clean interior and exterior surfaces as recommended by manufacturer. D. Touch up marred finishes, or replace fire-protection cabinets that cannot be restored to factoryfinished appearance. Use only materials and procedures recommended or furnished by fireprotection cabinet and mounting bracket manufacturers. E. Replace fire-protection cabinets that have been damaged or have deteriorated beyond successful repair by finish touchup or similar minor repair procedures. END OF SECTION 104413 FIRE PROTECTION CABINETS 104413-5