Instruction Manual. Satellite Switched, Power Monitoring Unit. RS2 Series

Similar documents
Instruction Manual Environmental Monitoring Unit with Output Relay

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

IFS Fiber Module Installation & Operation Instructions

Ion Gateway Cellular Gateway and Wireless Sensors

TLM-1 TOWER LIGHT MONITOR V3.0. INSTALLATION and OPERATING INSTRUCTIONS

KONICA MINOLTA GP-502 OPERATION MANUAL

General. General. Input. (1) 16 AMP Circuit Breaker. Communication. (1) RJ45 for Ethernet. Current Meter. Operation. Nominal Input Voltage 230V

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

RACK MONITORING SYSTEM - RAMOS Ultra

IndigoVision Alarm Panel. User Guide

Installation Instructions

SEE DISCLAIMER ON REVERSE

Batt-Safe Battery String Monitoring System

ECO PDU PE7214/PE7216/PE7324/PE7328

S541.RF 4G Product Guide

SKU# LC54225 Please retain these instructions for future reference. Adult assembly required.

IFS Fiber Module Installation & Operation Instructions


field SENSE EC-FS2-001-A

Powercom Ltd Powercom Building A, Ramat Hakovesh Israel Tel: +972 (9) Fax: +972 (9)

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

Pet Immune SAW PIR Motion Sensor

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

KWX N4 PDU. Intelligent, Rack Mounted, Power Distribution Units. The most innovative PDU on the market KWX-N16A10C3-H4F MONITORED & SWITCHABLE PDU

LORAIN CIP 4890/48120 DC Power System

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

Digijock Home Security

2 x screws. 2 x wall plugs

IFS Fiber Module Installation & Operation Instructions

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

Environmental Monitoring and Alarming

Intrinsically Safe Digital Float Monitor Instruction Manual

SensorHawk 4 PoE. For more information please visit us at or call us at 1 (800)

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

safety & regulatory information

IFS Fiber Module Installation & Operation Instructions

Installation and Operation Manual Low Power (LP) DC Power System

User Manual. Power Distribution Unit. Version: 1.0

ICT180S-12I INTELLIGENT MODEL (SERIES 2)

ADT. Pulse 2017ADT LLC

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

LORAIN CSP DC Power System

METEOROLOGICAL INSTRUMENTS

KWX- N1 N2 N3 N4 Remote Monitored PDU

Concord 5 TouchScreen Installation Sheet

Cisco TelePresence MCU 4200 Series safety and compliance information

Dominion PX. Intelligent Rack Power Distribution. Dominion PX Series. Broadest portfolio of smart PDUs to enable energy management in the data center

Using ANM Mobile CHAPTER

RACK MONITORING SYSTEM RAMOS Ultra

Innovative Circuit Technology Ltd.

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

Based on years of Industry experience it s ready to run right out of the box, simply assign the IP address and connect to the embedded web server.

ThermoControl 0 C - 10 C - 20 C - 30 C

Disclaimer. Trademarks. Copyright. Warranty

Performance Thermal Binder

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

ecobee 3 Quick Start Guide Installation Guide DRAFT

Galaxy Pulsar Plus Digital Battery Plant Controller

IntelliDoX Operator Manual

Knürr RMS Compact II. Knürr RMS Compact II 2.81

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

23-IN Electric Logset

T M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power

Monitoring Solutions

Pour & Float Froggy TM

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

3M Benchtop Air Ionizer 963E. User s Guide

DATAssure. Laboratory wireless alarm & monitoring system

[ [ ADMIN PANEL USER GUIDE

C-Bus Four Channel General Input Unit Installation Instructions

Proliphix Thermostat Installation Guide. Release 2.0

Code Alert Series 30 Software User Guide

Added password for IP setup page : Password must be in IP format!

MILLA ELECTRIC FIREPLACE

Please Keep This Manual For Future Reference REV.01

IFS Fiber Module Installation & Operation

DC-RMCU1 DC-Powered Remote Monitoring and Control Unit Owners Guide

Operating Manual. Gasgard 100 Control System. Order No.: /00. MSAsafety.com

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

SYSTEM OVERVIEW. Environmental Monitoring. Simplified.

Outdoor Temperature Sensor

Typical applications include the vibration detector. Detection of vibrations and shocks

ShockLink. Important Product Information.

Raytec Avigilon Integration User Guide Integrating Raytec Network Illuminators with Avigilon Control Center Document Revision 2.0

BROADBAND MODEL WITH REMOTE POWER CONTROL (SERIES 2) ICT180S-12BRC (FOR POSITIVE GROUND SYSTEMS) ICT180S-12BRCP (FOR NEGATIVE GROUND SYSTEMS)

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

KT-100 Door Controller

O2LPR67 Full HD Bullet IP LPR Camera

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Combined CAN Sensor Unit Temperature, Humidity and Smoke

CODE ALERT Enterprise Software User Guide

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

Quick start guide. SB3014-WM DECT 6.0 expansion wireless mic for use with AT&T model SB3014

Transcription:

Instruction Manual Satellite Switched, Power Monitoring Unit RS2 Series Geist. 1821 Yolande Ave., Lincoln, NE 68521 800.432.3219 402.474.3400 F: 402.474.4369 www.geistglobal.com

Contents Contents... 2 Specifications... 3 Overview 3 Environmental 3 Electrical 3 Receptacle Ratings 3 EMC Verification 3 Installation... 5 Guidelines 5 Mounting 5 Web Interface... 7 Overview 7 Sensors Page 7 Logging Page 8 Display Page 9 Alarms Page 10 Sensors... 12 Overview 12 Internal Sensors 12 Data Logging and Display 12 Service and Maintenance 12 More Technical Support 12 Table of Figures... 13 Revision History... 14 GM1104 2 Revision Date: 12/22/2014

Specifications Overview The RS2 Series expands the power of your Geist R-Series RSMINI, RSE, RSO, RCX, RSM, RCM, or RCU units (firmware version 3.00 and higher ONLY) with the addition of 2 outlets with remote switching and monitoring. RS2 Series units use the host unit s built in web server to display power monitoring data and give users control for installations needing switching of either one or two outlets. No software other than a web browser is required for operation and several data formats are available. RS2 Series units monitor Voltage, Current, Real and Apparent Power, and also provide a calculated Power Factor. The measurements are per unit, so both outlets are measured as one circuit. A single, Ethernet equipped host can connect multiple units within a cabinet or row by tethering units. Optional external sensors can monitor other environment factors. Note: On boot-up the RS2 will only turn on Outlet 1. After the RS2 has completed boot-up (about 5 seconds) Outlet 2 will turn on. This is to prevent a large inrush current if the RS2 is supplying power to certain devices. Environmental Temperature Operating: 10 C (50 F) min 45 C (104 F) max Storage: -25 C (-13 F) min 65 C (149 F) max Humidity Operating: 5% min 95% max (non-condensing) Storage: 5% min 95% max (non-condensing) Elevation Electrical Operating: 0 m (0 ft) min 2000 m (6561 ft) max Storage: 0 m (0 ft) min 15240 m (50000 ft) max See nameplate for unit ratings. Receptacle Ratings NEMA 5-15R 125 Volts, 15 Amp IEC-320 C13 125/250 Volt, 15 Amp (North America) or 10 Amp (Global) 1 IEC-320 C19 125/250 Volt, 20 Amp (North America) or 16 Amp (Global) EMC Verification This Class A device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 1 Given ratings are per receptacle bank GM1104 3 Revision Date: 12/22/2014

This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment. GM1104 4 Revision Date: 12/22/2014

Installation Guidelines Each host unit can support up to 16 attached sensors including RS2 units. Each host can support up to 600 feet of aggregate sensor cable length connecting the RS2 units, and other sensors, to the host. RS2 units are ONLY supported by Geist R-Series units with firmware version 3.00 or higher. If the RS2 is installed in a cabinet the ambient temperature of the rack should be no greater than 45C. Install the RS2 such that the amount of airflow required for safe operation of equipment is not compromised. Mount the RS2 so that a hazardous condition is not achieved due to uneven mechanical loading. Follow nameplate ratings when connecting equipment to the branch circuit. Take into consideration the effect that overloading of the circuits might have on over-current protection and supply wiring. The RS2 relies on the building installation for protection from over-current conditions. A Listed circuit breaker is required within the building installation. The circuit breaker should be sized according to the RS2 s nameplate ratings and local/national electrical codes. Reliable earth grounding of rack-mount equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit. The RS2 must be connected to an earthed socket-outlet. For pluggable equipment, install the RS2 so that the input plug or appliance coupler may be disconnected for service. Sequential power-up of devices powered by the RS2 is recommended to avoid high inrush current. Caution: Disconnect all power cords before servicing. Mounting The RS2 is made to be mounted to any flat surface using four (4) screws, as shown in Figure 2. The mounting holes are 1/4 diameter, so screws should be selected to fit and strong enough to securely hold the RS2 in place. The mounting hole dimensions are shown in Figure 1. Figure 1: RS2 Mounting-Hole Dimensions GM1104 5 Revision Date: 12/22/2014

Figure 2: Mounting the RS2 GM1104 6 Revision Date: 12/22/2014

Web Interface Overview The RS2 must be attached to a host unit via RJ-12 patch cable in order to view the RS2 on a network. The host unit is accessible via a standard, unencrypted HTTP connection as well as an encrypted HTTPS (SSL) connection. The following web pages change or contain added content after the RS2 Series unit is connected: Sensors Page The front page, Sensors, gives both instantaneous and historical views of the host unit s data. Real time readings are provided for all power strip and sensor data next to historical graphs. Each attached RS2 Series units will show a remote sensor section on the host unit s Sensors page. All power monitoring information will be shown here. Figure 3: Sensors Page - Remote Sensor GM1104 7 Revision Date: 12/22/2014

Logging Page The host unit s Logging page allows the user to access the historical data of the RS2 by selecting the desired readings and time range to be graphed. This is done the same way the sensor readings are graphed on the host unit. A new section will be shown for each RS2 added to the host unit. Figure 4: Logging Page GM1104 8 Revision Date: 12/22/2014

Display Page The host unit s Display page allows the user to assign friendly names to the RS2 unit. This friendly name is shown as the name of the RS2 on the host unit s other pages. This feature is helpful to distinguish one RS2 from another RS2 or from another sensor when attached to the same host device. Figure 5: Display Page GM1104 9 Revision Date: 12/22/2014

Alarms Page The host unit s Alarms page allows the user to establish alarm conditions for each sensor reading. Alarm conditions can be established with either high or low trip thresholds. To set an alarm, select the alarm type from the dropdown menu. Then select whether the alarm will trip above or below the threshold. Finally, set the threshold limit in the text box. If a notification is required, select the amount of time the alarm must be tripped before sending the notification and how often to repeat the notification. Then check the boxes for the desired notification types. Alarm notification options differ with each host but include a buzzer, e-mail and SNMP Trap. The RS2 adds the option of switching each outlet off or on when an alarm is tripped. Select the outlet that is desired to be switched and then go to the Control page to select the action to be taken. When an alarm is triggered the outlet will perform the selected action. Note: To enable alarm switching the user must read and accept the disclaimer located on the Config page s Admin tab. Figure 6: Alarms Page GM1104 10 Revision Date: 12/22/2014

Control Page The host unit s Control pages will become active after the RS2 is attached, if they are not already. The Control pages include an Actions tab and a Settings tab. The Settings tab gives the user the ability reset the kilowatt hours or to change the friendly names of the outlets on the RS2. The Actions tab contains the controls for the switching capabilities of the RS2. There are six options for switching the outlet: Manual off Turns off outlet. Manual on Turns on outlet. Alarm trips off Sets outlet to be turned off when alarm trips. Outlet will be on whenever the alarm is untripped. Alarm trips off, latching Sets outlet to be turned off when alarm trips. The outlet stays off until the Release to ON control button is pressed, even if the alarm is cleared. Alarm trips on Sets outlet to be turned on when alarm trips. Outlet will be off whenever the alarm is untripped. Alarm trips on, latching Sets outlet to be turned on when alarm trips. The outlet stays on until the Release to OFF control button is pressed, even if the alarm is cleared. Figure 7: Control Actions Page Figure 8: Control Settings Page GM1104 11 Revision Date: 12/22/2014

Sensors Overview The RS2 updates its measurements every 5 seconds. Like all external sensors, the RS2 s measurements are read by the host every 10 to 30 seconds, depending on the number of other sensors connected. Sensor data collected by the RS2 gives useful trend analysis data, and allows users to view changes and draw useful conclusions about what is happening over time in the monitored environment. Internal Sensors The RS2 contains the following onboard sensors: Volts: Measures instantaneous RMS voltage. Volts(Peak): Measures the highest reported voltage since the last time the data was updated, typically every 5 seconds. Amps: Measures instantaneous RMS current. Amps(Peak): Measures the highest reported current since the last time the data on the screen was updated, typically every 5 seconds. Real Power: Average of instantaneous voltage and current over the last 1.5 seconds. Apparent Power: The product of instantaneous RMS Voltage and RMS Current. This is the value used by circuit breakers. Power Factor: The ratio of Real Power to Apparent Power. Data Logging and Display All data collected by the RS2 can be graphed by the host unit. The host unit s Logging page allows the user to select graphed content to be logged. Selected sensor values are logged by the host unit at a rate of one point per minute and are shown on the Sensors page. Host units with LCD displays can optionally show sensor measurements there as well. The number of selected sensors determines the maximum data logging time span. This period is calculated and displayed on the Logging page. The oldest data will be deleted when the onboard memory fills up in order to make room for new data. All RS2 sensor values are shown on the RS2 s onboard display. Service and Maintenance No service or maintenance is required. Do not attempt to open the RS2 or you may void the warranty. No serviceable parts inside. It is recommended that power be removed from the unit before installing or removing any equipment. More Technical Support http://www.geistglobal.com (800) 432-3219 Email: support@geistglobal.com Or contact your distributor. GM1104 12 Revision Date: 12/22/2014

Table of Figures Figure 1: RS2 Mounting-Hole Dimensions... 5 Figure 2: Mounting the RS2... 6 Figure 3: Sensors Page - Remote Sensor... 7 Figure 4: Logging Page... 8 Figure 5: Display Page... 9 Figure 6: Alarms Page... 10 Figure 7: Control Actions Page... 11 Figure 8: Control Settings Page... 11 GM1104 13 Revision Date: 12/22/2014

Revision History Revision Date Notes Approved By 1.0 3/22/2011 Initial Version CDG, AK, BP 1.1 8/16/2011 Alarms outlet control features added CDG 1.2 6/5/2012 Logo and Website Update CDG GM1104 14 Revision Date: 12/22/2014