COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE

Similar documents
FIRE & LIFE SAFTEY STANDARD

Full Service Central Station Fire Alarm Listing Evaluation

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Unified Fire Authority - Fire Prevention Bureau

Bold items are particular to the City of Euless

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

Brighton Area Fire Authority

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS

El Reno Fire Department Fire Alarm Plan Review Worksheet

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

INSPECTION AND TESTING FORM

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

Idaho Surveying & Rating Bureau, Inc South Cobalt Point Way Tel: (208) Meridian, Idaho FAX: (208)

2019 COURSE CATALOG (rev )

Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance

SECTION : FIRE ALARM & DETECTION SYSTEMS

ORDINANCE NO. _ THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

CAN/ULC-S561. To comply, or not to comply. actually it s not even a question! Underwriters Laboratories of Canada. By Alan Cavers & Brian McBain

September 30, Dear Fire Suppression System Contractor/Designer:

Fire Permit Application

Florida Building Code 2010

You are required to READ ALL PAGES. of this application

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Valuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

APPENDIX H (DESIGN SUBMISSION CRITERIA)

Changes in NFPA

Southaven Fire Department Fire Marshal s Office 8710 Northwest Drive Southaven, Mississippi Phone: Fax:

Fire Alarm, Water Flow Alarm & Signaling Systems

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Fire - Rescue. November 2016

1.3 REFERENCE STANDARDS

SECTION WET-PIPE SPRINKLER SYSTEMS

PIKES PEAK REGIONAL BUILDING DEPARTMENT Fire Alarm Contractor License Application

Narrative Reports As Regulated by 780 CMR, Section 903.0

DATE: CHECK AMOUNT: CHECK NUMBER: RENEWAL APPLICATION. COMPANY CERTIFICATE OF REGISTRATION And INDIVIDUAL LICENSE RENEWAL

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

Please think twice about printing this matrix. You can it, along with your ballot to or

Sec False alarms.

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

STANDARDS UPDATE NOTICE (SUN) ISSUED: February 5, 2018

Design & Construction Standards, Revised January

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

HIGH-RISE RETROFIT ORDINANCES - NO and NO

May 1, Dear Fire Suppression System Contractor/Designer:

FIRE ALARM SYSTEMS INFORMATION PACKET. Des Moines Fire Department Fire Prevention Bureau

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

DONALD H. BERG, ARCHITECT

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

Design & Construction Standards, Revised January

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

Residential-based Care Facility R-4 Guideline

PROTECTED PROPERTY. City: State: Zip Code: ALARM SERVICE COMPANY. City: State: Zip Code: COMMENTS AND CLARIFICATIONS ALARM SYSTEM DESCRIPTION

Norfolk Fire Department Fire Prevention & Information

DEPARTMENT OF PUBLIC SAFETY DIVISION OF FIRE PREVENTION AND CONTROL

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

D. Reference Standards (Utilize latest editions available):

PERFORMANCE TECHNICAL SPECIFICATION *************************************************************************** SECTION D40 FIRE PROTECTION 02/18

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING.

Photovoltaic (Solar) Array Installation Guide

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

New Construction Fire Inspection Process

BIRCH RUN TOWNSHIP SAGINAW COUNTY, MICHIGAN ORDINANCE NO ALARM SYSTEM ORDINANCE AMENDMENT

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

Council of the City of York, PA Session 2008 Bill No. Ordinance No. INTRODUCED BY: Genevieve Ray DATE: November 18, 2008

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

DEPARTMENT OF PUBLIC SAFETY. Division of Fire Prevention and Control 8 CCR FIRE SUPPRESSION RULES

780 CMR: STATE BOARD OF BUILDING REGULATIONS AND STANDARDS

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

BIRCH RUN TOWNSHIP SAGINAW COUNTY, MICHIGAN ORDINANCE # ALARM SYSTEM ORDINANCE

Large Family Daycare Guideline

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

Chapter ALARM SYSTEMS

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau. Permit fees shall be assessed in accordance with the Permit Fee Schedule

SECTION FIRE ALARM SYSTEMS

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

The definitions provided in , C.R.S., shall apply to these rules and regulations. The following additional definitions shall also apply:

The definitions provided in , C.R.S., apply to these rules and regulations. The following additional definitions also apply:

PRIVATE FIRE SERVICE INSTALLATION PACKET

Town of York Alarm Systems Ordinance

Transcription:

COMMERCIAL (IBC) FIRE ALARM SUBMITTAL GUIDE SUPERVISION OF AUTOMATIC FIRE SPRINKLER SYSTEMS SUPERVISION OF ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS FIRE ALARM AND DETECTION SYSTEMS The Fire Alarm Ordinance of Manheim Township, applies to all systems whether they are required systems or not. As the authority having jurisdiction we will not waive major criteria found in the applicable NFPA standards. The codes and standards utilized provide for minimum standards. Equipment and designs, which do not meet minimum standards, shall be considered substandard. Any deviation from a listed standard must be requested in writing and is subject to approval by the Director of Code Compliance. 1840 Municipal Drive, Lancaster, PA 17601 (717) 569-6406, ext. 6 codecompliance@manheimtownship.org 1 P a g e

MANHEIM TOWNSHIP DEPARTMENT OF CODE COMPLIANCE FIRE ALARM ORDINANCE OF MANHEIM TOWNSHIP FIRE PROTECTION SIGNALING SYSTEMS AND AUTOMATIC FIRE DETECTION SYSTEMS INSTALLED WITHIN MANHEIM TOWNSHIP APPLICABILITY. Certification of Systems: All newly installed required fire alarm systems shall be certificated by UL, FM or other recognized NRTL as required in the National Fire Alarm Code also known as National Fire Protection Association, NFPA 72 referenced herein. NEW SYSTEMS. Fire alarm systems for new buildings or other structures shall be installed as provided in the building, fire and other applicable codes in effect in Manheim Township. Permits shall be applied for & obtained as provided in this ordinance. EXISTING SYSTEMS. Additions or Alterations to or Rehabilitation of Structures: Enclosed additions or interior alterations to, change in use of, or major rehabilitation of any building shall require that existing fire alarm systems shall conform to the requirements for new fire alarm systems as described herein. DUTIES AND POWERS OF CODE OFFICIALS AND FIRE OFFICERS. Inspections: The Director of Code Compliance or a Code Official shall make all required inspections of premises to enforce compliance with the provisions of this ordinance. Inspections shall include, but are not limited to, a final acceptance test. DUTIES AND POWERS OF CODE OFFICIALS AND FIRE OFFICERS. Application and Permits: The Department of Code Compliance shall receive applications, plans, specifications, monitoring/ supervisory information, permit fees and shall issue permits for the installation of, additions, extensions or alterations to fire alarm systems. A Code Official shall inspect the premises for which such permits have been issued and enforce compliance with the provisions of this ordinance. APPLICATION FOR PERMIT. When Permit is Required: It shall be unlawful to alter or add to existing fire alarm systems or to install a fire alarm system or related components of a fire alarm system for which provisions are made or the installation of which is regulated by this ordinance, without first filing the appropriate application, paying the applicable fee, and submitting the required design information with the Department of Code Compliance in writing and obtaining the required permit. FIRE ALARM CONTRACTORS LISTED FOR CENTRAL STATION SERVICE: Fire alarm contractors shall be listed by an established and nationally recognized organization (such as UL, FM or other approved NRTL), which approves the qualifications of fire alarm service contractors for Central Station Service. (Exception Installations in 1 & 2 Family Dwellings Only) 2 P a g e

SUBMITTAL & INSPECTION PROCEDURES Submit the following information for review and approval. System installations are not to start until a Code Official has reviewed and approved the submittal. All work is subject to field inspection and approval. For standalone projects submit applicable permit fee for proposed Fire Alarm Systems + UCC Mandated Education Fee. If proposed fire alarm system is associated with a larger project being constructed under a valid building permit, no additional permit fees beyond the building permit fee are due. Fees are based on current fee resolution. This applies to existing structures and new construction, which are not included in the original building permit application. The fee must accompany the application. Submit valid UL Central Station UUFX Certificate(s) of Compliance or FM 3011 Central Station Certificate(s) of Compliance legitimizing Central Station Service. All fire alarm contractors shall be at least one (1) of the following. Check the applicable box for this project and provide the noted UL, FM or other NRTL Certificate(s) for all companies. Listed Central Station will provide all six (6) elements of Central Station Service (1)Installation, (2)Testing/Maintenance, (3)Runner Service, (4)Monitoring of Signals, (5) Retransmission of Signals, and (6) Record Keeping. UL UUFX/FM 3011 Certificates needed for runner service with maximum 2 hour service distance Listed Central Station will provide the three (3) elements at the supervising station and subcontract one or more of the three (3) elements at the protected premises. Provide valid UL UUFX or FM 3011 Certificates for ALL fire alarm companies. UL UUFX/FM 3011 Certificates needed for runner service with maximum 2 hour service distance Listed Fire Alarm Service Local Company will provide Installation, Testing and Maintenance at the protected premises and subcontract the supervising duties to a listed Central Station. Provide valid UL UUFX or FM 3011 Certificates for all fire alarm companies. UL UUFX/FM 3011 Certificates needed for runner service with maximum 2 hour service distance Submit current Certificate(s) of Insurance listing both Worker s Compensation and Liability Insurance with Manheim Township Code Compliance, 1840 Municipal Drive, Lancaster PA 17601 listed as the Certificate Holder Two (2) sets of construction documents must be submitted for review. All plans shall be dimensioned. One (1) set of construction documents will be returned to the applicant upon permit issuance. (Note: Submittals that are for required systems shall be signed and sealed by a NICET level III or IV, or a professional engineer licensed in Pennsylvania.) Riser diagrams and floor plans must accompany the submittal. Zone layouts must be clearly indicated. Battery calculation sheets must be submitted, which clearly show 24-hour standby calculations and five-minute alarm power calculations. Catalog cuts or manufacturer s information must be submitted which shows the devices and equipment to be installed to be UL listed. Listed spacing of devices must be indicated. 3 P a g e

SUBMITTAL & INSPECTION PROCEDURES Submit the following information for review and approval. System installations are not to start until a Code Official has reviewed and approved the submittal. All work is subject to field inspection and approval. Fire alarm control panels must bear the UL protective services label (for commercial fire use). DACT s installed within commercial facilities shall communicate per NFPA 72. Communication methods must be detailed as part of the plan submittal. All new or existing required systems being modified shall be certified by UL, FM or other approved NRTL. Trouble signals and supervisory signals shall be transmitted to the alarm company or property owner not to the Manheim Township Police Department. Lock boxes must be installed prior to scheduling a final inspection of either a newly installed or altered system. Final acceptance tests must be conducted with a Township Inspector present. 48-hour notice must be given for scheduling inspection(s). The necessary keys for the lock box must be made available at the final acceptance test. The Code Official will secure said keys within the lock box at that time. The fire alarm contractor shall be present for all final acceptance testing. Prior to Manheim Township witnessing the final acceptance test, the system shall be tested 100% by the fire alarm contractor. Certificate of Completion forms must be completed and presented to the Township code official at the time of the final test. Upon completion of a required fire alarm system, submit a copy of the UL, FM or other NRTL System Certification, a copy of the Central Station monitoring contract (if applicable), and a copy of an Inspection, Testing and Maintenance contract (if applicable). 4 P a g e

TO BE COMPLETED BY PERMIT APPLICANT Project Street Address Subdivision Architect/Engineer Contractor Name Address Phone # Sub-contractor Name Address Phone # I hereby certify that the proposed work is authorized by the owner of record and that I have been authorized by the owner to make this application as his authorized agent and agree to conform to all Manheim Township zoning ordinances, and applicable IBC Code and NFPA requirements, as adopted or referenced by Manheim Township. Submittal by: Permit Applicant Name & Name of Company Address Phone # Date Provide a general description of the fire alarm system, including basic components. Type of system, for example automatic fire detection system, fire alarm system, supervision of automatic fire sprinkler system by central station., etc. 5 P a g e

Provide a clear description of the system ground here: Size and type of grounding electrode conductor and point of attachment, i.e. Cold Water Pipe. Provide battery calculations for 24-hour standby and 5 minute alarm power: System Power Supplies a. Fire Alarm Control Panel: Normal Voltage: Amps: Overcurrent Protection: Type Amps: Location of Fire Alarm Control Panel: b. Secondary (Standby): Storage Battery: Amp Hr. Rating Calculated capacity to operate system, in hours: 24, 60 Engine-driven generator dedicated to fire alarm system: c. Emergency or Standby System used as backup to Primary Power Supply, instead of using a Secondary Power Supply: Emergency System described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701. Provide a clear description of the type and number of batteries to be installed here; type of charging unit. Location of Lock boxes must be shown on plans. 6 P a g e

CODE COMPLIANCE SUBMITTAL REVIEW CHECKLIST Building Permit # Project Address NFPA 72 Central Station Service Central station Monitoring Agreement signed by subscriber Manufacturer s information sheets for all devices & equipment: Fire alarm control panel Alarm verification Smoke detectors - Spot-type or Projected Beam Duct detectors Heat detectors Manual fire alarm boxes Alarm notification appliances Wiring type Fire Sprinkler supervision flow, control valve tamper, & low air devices Fire Pump supervision pump running, power failure & phase reversal Elevator recall System grounding Battery calculations Riser & Point to Point wiring diagrams Floor plans with ceiling construction type(s), & ceiling heights Location of annunciator panels Zone description(s) local & transmitted to central station Supra Lock Box - location & supervisory circuit NFPA 72 Inspection, Testing & Maintenance contracts Final Acceptance Test & Certificate of Compliance Date of Review: Reviewer: Date of Approval: Code Official Signature Comments: 7 P a g e