Saving energy while ensuring an enhanced room climate

Similar documents
Install intelligent room automation flexibly and future-proofed

Semi flush-mount communicating room thermostats

Answers for infrastructure. HVAC control with Synco simple and energy-efficient

Application Guide siemens.com/thermostats

Save energy while maintaining a constant room climate

Flush-mounted room thermostats

Wall-mounted room thermostat with LCD

Room thermostats with LCD for wall mounting

Flush-mounted room thermostat

Synco living combines individual room control with consumption data acquisition

Touch Screen Flush-mount Room Thermostats with KNX Communications

Semi flush-mount room thermostat

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

A comprehensive range of controllers, from stand-alone to communicating for any requirement. HVAC control with Synco Simple and energy-efficient

Application guide RDG160 Remote control

Semi-flush mount communicating room thermostats RDF301, RDF , RDF600KN

Application Sheet Fan coil unit with staged fan, 6-way heating/cooling coil (4 pipe) on analog output

Room thermostats with KNX communications RDG100KN, RDG160KN, RDG165KN

Room thermostats with KNX communications RDG100KN, RDG160KN

Wireless room thermostat with LCD

Cerberus FIT conventional system

Room thermostat with KNX communications RDG100KN

Room thermostat with KNX communications RDG400KN

Siemens room thermostats. For maximal comfort and energy efficiency

Room thermostat with Auto Timer, Option External Input

Synco-Gamma Application Guide. Retirement and nursing homes.

Application Sheet Chilled/heated ceiling (4 pipe) with 6-way valve on analog output

Synco-GAMMA Application Guide. Hotel buildings. Answers for infrastructure.

Room thermostat with KNX communications RDG400KN

Coziness and comfort in every room

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

ROOM THERMOSTATS KNX BASIC DOCUMENTATION

Room thermostat with Auto Timer, Option External Input

Room thermostats with LCD for wall mounting RDG100 RDG100T RDG110, RDG110U RDG160T, RDG160TU RDG100T/H

Room thermostat with Auto Timer, Option External Input

Room thermostat with independent DHW control

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Flush-mounted room temperature controllers for VAV / CAV applications, with LCD RDU340

Room thermostats with LCD RDD100..

Room thermostat with Auto Timer, Option External Input

A comfortable temperature throughout the home

Room thermostats with KNX communications RDG100KN, RDG160KN, RDG165KN

DESIGO - Answers for infrastructure. Energy-efficient applications: h,x-controlled Economizer tx2. Application data sheet

Room thermostat with display, for VAV RDG400

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Semi-flush mount room thermostats with KNX communications RDU341. Basic Documentation. Edition: 1.2. CE1P3172en Building Technologies

Smart Thermostat RDS110

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Applications for correctional facilities. Greater efficiency and cost-effectiveness with GAMMA building control. Answers for infrastructure.

Room thermostats with display, for fan coil units RDG100, RDG100T, RDG110, RDG140, RDG160

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM.

Installer Manual KNX Touchscreen Thermostat

1. Product description

Room Temperature Controllers

Room thermostats with LCD for wall mounting RDG100, RDG100T, RDG110, RDG140, RDG160, RDG100T/H

Application Sheet Fan coil unit with staged fan, heating and cooling coil (4 pipe) on triac output including lighting and blinds operation

Self-learning Room Temperature Controller

Control Products & Systems OEM

Room thermostat with 24-hour time switch and large LCD

RAA30 RAA30.16/GR RAA30.26/GR. Room Thermostat. Adjustable room thermostat for heating only or cooling only systems

Use. For 2-pipe fan coils

Your specialized partner for intelligent building technology

Semi flush-mount room thermostats

Room Temperature Controller

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller

Acvatix PICV hydronics made easy. The simple and flexible way to energy-efficient HVAC plants with pressure-independent combi valves

Saving energy with Synco

New semi flush-mount room thermostats RDD310 / RDE410

Preliminary Release. Room Temperature

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

Immersion Temperature Controller

Room Temperature Sensors

SIMPLICITY FULL MODULARITY?

SIMPLICITY OR FULL MODULARITY?

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

REA22 Room Temperature Controller

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

Room Temperature Controller with LCD

HVAC Products. SAPHIR AirGo OEM Air Handling Unit Concept

Self-learning Room Temperature Controller

Sinorix Silent Extinguishing Technology protecting the quiet way

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

Heating and D.h.w. Controller RVL482 Basic Documentation

Room thermostat with Auto Timer, independent DHW

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

RVD120, RVD140 Controllers for district heating and d.h.w. Basic Documentation

Optimal control for superior lighting performance

Room Temperature Controller

RVL479. Heating Controller. for use with a partner unit

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Control Products & Systems OEM

Applications in banks. Economically efficient, customer friendly and ready for the future with GAMMA building control. Answers for infrastructure.

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Self-learning Room Temperature Controller

District Heating Controller

Frost Units for air temperature monitoring

Transcription:

he worldwide standard for home and building control Saving energy while ensuring an enhanced room climate Lower operating costs without loss of room comfort, thanks to communicating room thermostats Energy-efficient operation he communicating room thermostats RDG and RDF increase your building s energy efficiency, irrespective of usage private or commercial. his way, compliance with performance class A as per efficiency class EN 15232 can be attained. hanks to the open communication standard KNX, the room operator units can be straight-forwardly and seamlessly integrated into existing or new building automation and control systems. Additional cost savings in terms of operation and energy consumption are made possible via the time programs, which ensure timely heating or cooling. Ease of operation he room thermostats excel in modern design and user-friendly operation. hanks to their large displays and clear characters, temperature and time of day are easy to read. emperature can be displayed in degrees Celsius or Fahrenheit. he measured values acquired by the room thermostats can be monitored by the building automation and control system. Very versatile suited for heating and cooling he communicating compact devices with built-in sensors are suited for a host of applications, such as fan coil units, VAV plants, chilled ceilings, heating systems or heat pumps. Consistent design and uniform operation can thus be implemented in buildings operating with different types of heating and cooling systems. Highlights Energy-efficient and costsaving temperature control Intuitive and user-friendly design ensuring ease of operation Great control accuracy for optimum room comfort Straightforward integration into building automation and control systems High level of functionality thanks to versatile connection facilities Applications of the RDG160KN may reach efficiency class AA according to eu.bac www.siemens.com/thermostats

Fan coil unit Legend: 1 hermostat 3 2 External air temperature sensor 2 1 3 Window contact 4 Heating/cooling fan coil unit 5 Presence detector/card reader 5 KNX 6 Radiator valve 4 6 Heat pumps 4 Legend: 1 hermostat 3 2 External air temperature sensor 2 1 3 Window contact 4 Dewpoint sensor 5 Presence detector/card reader 5 KNX 6 Heat pumps 6 Universal applications 4 6 Legend: 1 hermostat 3 2 External air temperature sensor 2 1 3 Window contact 4 Dewpoint sensor 5 Presence detector/card reader 5 KNX 6 Refrigerant valve 7 7 Radiator valve Variable air volume 4 Legend: 1 hermostat 3 2 External air temperature sensor 2 1 3 Window contact 4 Damper actuator 5 Presence detector/card reader 5 KNX 6 Radiator valve 6

echnical Specifications ype RDG100KN RDG160KN RDF800KN Description RDG100KN Room thermostat with KNX communication Fan coil system and universal heating/cooling applications Operating modes: Comfort, Economy and Protection mode On/Off, 3-positions or PWM control outputs Fan automatic or manual for 1- or 3-speed fan 3 multifunctional inputs for keycard contact, external room/ return air sensors, heating/cooling switchover, switchover mode, window contact On/Off, dew point monitoring, electrical heater enable, faults, monitor input Automatic or manual heating/cooling mode switchover Adjustable commissioning and control parameters Minimum and maximum limitation of setpoint Backlit display 2-pipe systems 2-pipe systems with electrical heating 2-pipe systems with radiator/ floor heating 4-pipe systems 4-pipe systems with electrical heating 2-pipe, 2-stage heating/cooling systems Operating voltage: AC 230 V, 50/60 Hz Power consumption: 8 VA RDG160KN Room thermostat with KNX communication Fan coil system, universal heating/cooling, heat pump applications Operating modes: Comfort, Economy and Protection mode For applications with DC 0...10 V and On/Off control outputs and DC fan For applications with DC 0...10 V control outputs and DC / 3-/ 1-speed fan Fan automatic or manual 3 multifunctional inputs for keycard contact, external room/ return air sensors, heating/cooling switchover, switchover mode, window contact On/Off, dew point monitoring, electrical heater enable, faults, monitor input, supply air temperature sensor Automatic or manual heating/cooling mode switchover Adjustable commissioning and control parameters Minimum and maximum limitation of setpoint Supply air temperature limitation Backlit display 2-pipe systems 2-pipe systems with electrical heating 2-pipe systems with radiator/ floor heating 4-pipe systems 2-pipe, 2-stage heating/cooling systems RDF800KN Flush-mount room thermostat with KNX communication and touch screen Fan coil system, universal heating/cooling, heat pumps Operating modes: Comfort, Economy and Protection mode For heating and/or cooling applications Outputs for On/Off, 3-positions signal Outputs for conduit 1- or 3-speed fan 2 multifunctional inputs for keycard contact, external room/ return air sensors, heating/cooling switchover, presence detector, window contact On/Off, dew point monitoring, electrical heater enable, faults, monitor input Automatic or manual heating/cooling mode switchover Adjustable commissioning and control parameters Minimum and maximum limitation of setpoint Backlit display Housing color: Ivory white 2-pipe systems 2-pipe systems with electrical heating 4-pipe systems Control algorithm 2P/PI Ambient temperature for operation: 0...50 C emperature measuring range: 0...49 C Switching differential: heating: 0.5...6 K, cooling: 0.5...6 K Communication: KNX (S-mode and LE mode) Commissioning via tool (ES, ACS) or HMI Analog input signals: NC 3k, switch Digital input: 1 Relay outputs: Fan: 1- or 3-speed Relay outputs: 3 x AC 230 V, 5 (4) A riac outputs: valve, el. radiator, On/Off, PWM, 3-position Number of riac outputs: 3 x 230 V AC, max. 1 A Wall mounted unit using screws Operating voltage: AC 24 V, 50/60 Hz Power consumption: 2 VA Control algorithm 2P/PI Ambient temperature for operation: 0...50 C emperature measuring range: 0...49 C Switching differential: heating: 0.5...6 K, cooling: 0.5...6 K Communication: KNX (S-mode and LE mode) Commissioning via tool (ES, ACS) or HMI Analog input signals: NC 3k, switch Digital input: 1 Relay outputs: fan: 1- or 3-speed, 2 x valve, electric radiator Relay outputs: 3 x AC 24...230 V, 5 (4) A Analog output: 2 x Valve, 1 x fan, 3 x DC 0 10 V, max. +/- 1 ma Wall mounted unit using screws Operating voltage: AC 230 V, 50/60 Hz Power consumption: 6 VA Control algorithm 2P/PI Ambient temperature for operation: 0... 50 C Switching differential: heating: 0.5...6 K, cooling: 0.5...6 K emperature measuring range: 0...49 C Communication: KNX (S-mode and LE mode) Comissioning via tool (ES, ACS) or HMI Analog input signals: NC 3k, switch Relay outputs: Fan: normally open contact, non-floating, Valve: normally open contacts, non-floating Relay outputs: 5x AC 230 V, 5 (2) A Bus current 5 ma Mounting on round conduit boxes with min. 60 mm diameter, min. 40 mm depth an on rectangular conduit box ARG71 (BS4662), distance of fixing holes 60.3 mm

ype RDF600KN RDF301.50 RDF301.50H Description RDF600KN, RDF301.50, RDF301.50H Flush-mount room thermostats with KNX communication Fan coil system and heat pump applications Flush-mount room thermostat with LCD For heating and/or cooling applications Outputs for On/Off, 3-positions signal Outputs for 1- or 3-speed fan 2 multi-functional inputs for keycard contact, external room/return air sensors, heating/cooling switchover, switchover mode, window contact On/Off, dew point monitoring, electrical heater enable, faults, monitor input Operating modes: Comfort, Economy and Protection mode Automatic or manual heating/cooling mode switchover Adjustable commissioning and control parameters Minimum and maximum limitation of setpoint Backlit display Housing color : white (RAL 9003) 2-pipe systems 2-pipe systems with electrical heater 4-pipe systems Operating voltage: AC 230 V, 50/60 Hz Power consumption: 4 VA Control algorithm 2P/PI Ambient temperature for operation: 0...50 C emperature measuring range: 0 49 C Switching differential: 0.5...6 K Communication: KNX (S-mode and LE mode) Commissioning via tool (ES, ACS) or HMI Analog input signals: NC 3k, switch Relay outputs: Fan: normally open contact, non-floating, Valve: normally open contacts, non-floating Relay outputs: 5 x AC 230 V, 5 (2) A RDF600KN Room thermostat Bus current 5 ma Mounting on round conduit boxes with min 60 mm diameter, min. 40 mm depth Multifunctional input also for presence detector RDF301.50 Room thermostat Mounting on rectangular conduit box ARG71 (BS4662), Distance of fixing holes 60.3 mm 4 buttons to control KNX actuators via KNX S-mode (Functions: switching, dimming, blinds, 8-bit-scene) RDF301.50H Room thermostat Mounting on rectangular conduit box ARG71 (BS4662), Distance of fixing holes 60.3 mm 4 buttons to control KNX actuators via KNX S-mode (Hotel functions: Please do not disturb; Make Up Room) RDG400KN RDG400KN Room thermostat with KNX communication VAV heating and cooling systems Operating modes: Comfort, Economy and Protection mode Control depending on the room or return air temperature Output DC 0 10 V VAV box/damper and additional output for On/Off, PWM or 3-position or output for 3-position VAV box/damper and additional output DC 0 10 V Automatic or manual heating/cooling mode switchover 1 multifunctional input for keycard contact, external room/ return air sensor, heating/cooling switchover, switchover mode, window contact On/Off, dew point monitoring, electrical heater enable, faults, monitor input 1 input DC 0 10 V for damper position feedback Adjustable commissioning and control parameters Minimum and maximum limitation of setpoint Minimum and maximum limitation of air flow signal Output signal inversion (DC 10 0 V) as option Backlit display Single-duct systems Single-duct systems with electrical heating Single-duct systems and radiator/floor heating Single-duct systems with heating and cooling coil Operating voltage: AC 24 V, 50/60 Hz Power consumption: 2 VA Control algorithm P/PI Ambient temperature for operation: 0...50 C emperature measuring range: 0...49 C Switching differential: heating: 0.5...6 K, cooling: 0.5...6 K Communication: KNX (S-mode and LE mode) Commissioning via tool (ES, ACS) or HMI Analog inputs: NC 3k, DC 0...10 V Analog output: VAV box/damper, electrical heater Analog output: 1 x DC 0 10 V, max. +/- 1 ma Digital input: 1 riac output: VAV box/damper, valve, electrical heater, On/Off, PWM, 3-position riac output: 1 x AC 24 V, max. 1A Wall mounted unit using screws

ype RDU341 Description RDU341 Flush-mount room thermostat with KNX communication VAV heating and cooling systems Flush- mount room thermostat with LCD Modulating PI control Room or return air temperature control Outputs for a DC 0...10 V actuator and AC 230 V electrical heating (On/Off) Automatic or manual heating/cooling mode switchover Operating modes: Comfort, Economy and Protection function 2 multifunctional inputs for keycard contact, external room / return air sensors, heating/cooling switchover, switchover mode, window contact On/Off, dew point monitoring, electrical heater enable, faults, monitor input Adjustable commissioning and control parameters Minimum and maximum limitation of setpoint Minimum and maximum limitation of of air flow signal Output signal inversion (DC 10 0 V) as option Single-duct systems Single-duct systems with electrical heating Operating voltage: AC 24 V, 50/60 Hz Power consumption: 4 VA Control signal: DC 0...10 V Control algorithm P/PI Ambient temperature for operation: 0 50 C emperature measuring range: 0...49 C Switching differential: 0.5...6 K Communication: KNX (S-mode and LE mode) Commissioning via tool (ES, ACS) or HMI Analog input signals: NC 3k, switch Analog output: 1 x DC 0...10 V, max. 1 ma Relay output: normally open contact, floating Relay output: 1 x AC 230 V, max. 5 (2) A Mounting on rectangular conduit box ARG71 (BS4662), distance of fixing holes 60.3 mm RDF600KN RDF301.50 RDF301.50H RDG100KN RDG160KN RDG400KN RDU341 RDF800KN Dimensions Height mm 86 86 128 86 86 Width mm 86 86 93 86 86 Depth mm 46 57 30,8 57 47

Dimensional drawings RDF301... RDF600KN RDF800KN I201_18966 I201_18966 86 86 86 86 30 I201_18967 I201_18968 14 41 16 30 17 52 47 47 I201_18969 51 67 I201_18965 80 51 60 60 80 60

Selection and ordering data ype Version D Order No. PU (Unit, Set, M) PS*/ P.unit PG Weight per PU approx. kg RDG100KN RDG100KN Room thermostat with KNX communication Fan coil system and universal applications B S55770-163 1 1 Unit A08 0,380 S55770-163 RDG160KN RDG160KN Room thermostat with KNX communication Fan coil system, universal and heat pump applications B S55770-297 1 1 Unit A08 0,320 S55770-297 RDF800KN RDF800KN Flush-mount room thermostat with KNX communication and touch screen Fan coil systems, universal heating/cooling and heat pump applications B S55770-350 1 1 Unit A08 0,320 S55770-350 RDF600KN RDF600KN Flush-mount room thermostat with KNX communication Fan coil system and heat pump applications B S55770-293 1 1 Unit A08 0,220 S55770-293 S55770-105 S55770-334 RDF301.50 RD301.50H RDF301.50 Flush-mount room B S55770-105 1 1 Unit A08 0,320 thermostat with KNX communication 1) Fan coil system and heat pump applications, 4 buttons to control KNX actuators via KNX S-mode (switching, dimming, blinds, 8-byte scene) RDF301.50H Flush-mount room B S55770-334 1 1 Unit A08 0,320 thermostat with KNX communication 1) Fan coil system and heat pump applications, 4 buttons to control KNX actuators via KNX S-mode (hotel functions: Please do not disturb, Make up room) RDG400KN RDG400KN Room thermostat with KNX communication VAV heating and cooling systems B S55770-165 1 1 Unit A08 0,337 S55770-165 RDU341 RDU341 Flush-mount room thermostat B S55770-106 1 1 Unit A08 0,243 with KNX communication 1) VAV heating and cooling systems S55770-106 ARG71 ARG71 Flush-mounting boxes B S55770-137 1 1 Unit A08 0,081 For all RDU/RDF acc. to BS4662 Dimensions (H x W x D): 82 x 82 x 47 mm S55770-137 1) he matching ARG71 conduit box must be ordered separately.

Siemens Switzerland Ltd Building echnologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland el +41 41 724 24 24 Siemens Building echnologies Brunel House Sir William Siemens Square, Frimley Camberley Surrey, GU16 8QD United Kingdom el +44 1276 696000 Siemens Ltd Building echnologies Division 22/F, AIA Kowloon ower, Landmark East 100 How Ming Street Kwun ong, Hong Kong el +852 2870 7888 he information in this document contains general descriptions of technical options available, which do not always have to be present in individual cases. he required features should therefore be specified in each individual case at the time of closing the contract. he document contains a general product overview. Availability can vary by country. For detailed product information, please contact the company office or authorized partners. Siemens Switzerland Ltd, 2014 B_0038_EN Our world is undergoing changes that force us to think in new ways: demographic change, urbanization, global warming and resource shortages. Maximum efficiency has top priority and not only where energy is concerned. In addition, we need to increase comfort for the well-being of users. Also, our need for safety and security is constantly growing. For our customers, success is defined by how well they manage these challenges. Siemens has the answers. We are the trusted technology partner for energy-efficient, safe and secure buildings and infrastructure. www.siemens.com/thermostats