Effective temperature, relative humidity and air velocity combinations to provide most effective chilling

Similar documents
PRINCIPLES OF REFRIGERATION ~ CHILLER EFFICIENCY & CONDENSATION by PM Husband

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Use this Construction/HVAC Glossary to answer the questions below.

Levels of Production

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

AIM: TO STUDY THE PERFORMANCE OF THE DOMESTIC REFRIGERATION RIG.

HVAC Fundamentals & Refrigeration Cycle

VISUAL PHYSICS ONLINE THERMODYNAMICS WHAT HAPPENS WHEN SOMETHING IS HEATED? LATENT HEAT

Air-Cooling Evaporators

DEFROSTING METHODS Adapted from material originally provided by Kenneth S. Franklin, C.M., Director of Service, Hussmann Corporation

RSES Technical Institute Training Manual 1 70 hours, 70 NATE CEHs, 7.2 CEUs

Chilled Water system

MECHANICAL SCIENCE Module 2 Heat Exchangers

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

Cooking using the sous vide technique

To accomplish this, the refrigerant fi tis pumped throughh aclosed looped pipe system.

KE2 EvaporatorEfficiency Theory of Operation

Small Commercial Business Energy Audits. Recognizing and addressing the special requirements of the small business market segment.

Unit THE NATURE OF HEAT

1. What are the scales of temperature? What are the formulas to convert among them? Fahrenheit, Celsius, Kelvin

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

BLAST FREEZING APPLICATIONS IN CONVENTIONAL ROOMS

Technical press. Quick freezing. Gently freezing with cryogenic gases

MECHANICAL SERVICES 101. Ian White

Moisture in the Atmosphere. GEOG/ENST 2331 Lecture 9 Ahrens: Chapter 4

Purpose of Refrigeration

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Last exam / sista tent

Heat Exchangers DKRCC.PF.000.G1.02 / 520H6410

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Transcritical CO2 Bottle Cooler Development

Pressure Enthalpy Charts

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

Clean, Silent and Efficient Refrigeration Solutions for Distribution and City Operations

THERMAL ICE STORAGE: Application & Design Guide

Air Conditioning Inspections for Buildings Condensers

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

Why use Blast Chiller or Freezer?

Heat Pump Assisted Drying - Freeze Drying Technology

LECTURE-18 Vapour Absorption Refrigeration System

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.


Energy Use in Refrigeration Systems

Sustainable Techniques in Refrigerated Space

Basic Principals of Air conditioning By Dr. Esam Mejbil Abed

BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

Energy use in the chilled food sector. Case study Air blast chilling of solid/liquid food mixtures. (pie fillings)

THE INSTITUTE OF REFRIGERATION

Fundamentals of Refrigeration Part 2 Refrigeration 1

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

Mechanical Engineering Department Sheet (1)

ME 354 THERMODYNAMICS LAB THE REFRIGERATION CYCLE

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

6. Within an internal combustion engine, the can-shaped component that moves up and down the cylinder

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

START-UP TRAINING AND INSTRUCTIONS HURRICHILL BLAST CHILLERS

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

The impact of water treatment on refrigeration system energy efficiency

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS

SECTION 7 AIR CONDITIONING (COOLING) UNIT 40 TYPICAL OPERATING CONDITIONS UNIT OBJECTIVES

Hygrometry. The art or science of humidity observation

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

Experimental Investigation on Domestic Refrigerator by Shell and Tube Heat Exchanger after the Condenser Using Sub Colling of Refregaring Fluid

The Refrigeration Cycle (Air Conditioners)

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Refrigeration Systems and Accessories

Available online Journal of Scientific and Engineering Research, 2017, 4(12): Research Article

2. CURRICULUM. Sl. No.

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

CTI Sponsored Educational Program

Module 1: Introduction to Radiant Cooling. Pierre Jaboyedoff

Performance Enhancement of Mini Refrigerator with Phase Change Materials

Technical Papers. 31st Annual Meeting. International Institute of Ammonia Refrigeration. March 22 25, 2009

A. GENERAL INFORMATION No. 23(1) GUIDELINES FOR CONVECTION OVENS A convection oven has a blower fan which circulates hot air throughout the oven,

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Drying rate 1. Section B to C of the curve, known as the constant rate periods, represents removal of unbound water from the product.

Class 1: Basic Refrigera0on Cycle. October 7 & 9, 2014

200L Chest Freezer / GVATCS20Q. Instruction Manual

Efficient Steam System Design

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

CO 2 EVAPORATOR DESIGN

St. Anthony's Canossian Secondary School Sec 3E Science (Physics) Chapter 9 Transfer of Thermal Energy. Name: ( ) Class: Sec Date:

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Chapter-8 Capacity Control of Refrigeration Systems

CARCASS CHILLER DESIGN

c o n d e n s e r Glossary of Terms

1. SAFETY WARNINGS INSTALLTION Location Reversing the Door Swing Levelling the Unit... 3

BASIC HEAT PUMP THEORY By: Lloyd A. Mullen By: Lloyd G. Williams Service Department, York Division, Borg-Warner Corporation

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Case 13 Food Storage & Processing Center

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

ThermoSaver TM Hot Gas Defrost System

Engineering Tomorrow's Industrial Refrigeration Solutions in KSA

Food preparation, cooking and service

Presentation on HVAC: Heating Ventilation Air Conditioning

Transcription:

Effective temperature, relative humidity and air velocity combinations to provide most effective chilling Prof Louw Hoffman Department of Animal Sciences Stellenbosch University RMAA Conference 10 May 2012 1

Contents Principles Applications Equipment Product quality The future: re-visiting an old friend 2

Principles Most meat not consumed immediately To extend shelf life and minimise bacterial growth Drying, curing, smoking, heat processing, fermentation, irradiation, canning & refrigeration Product indistinguishable from fresh product Transferring heat from one product to another 3

Principles Heat flows naturally from hot to cold Masses of material also moved around by refrigeration system Include: Air/liquid in which heat is carried from food product to air/liquid cooler Water vapour/other gases carried in the air Primary & secondary refrigerants in refrigeration system self 4

Fundamentals of heat transfer Three fundamental mechanisms Conduction Convection Radiation Most refrigeration processes contain combination of conduction & convection Radiation occasionally significant 5

Conduction Molecules of solid/liquid/gas in contact with each other Two molecules in contact one with higher energy transfers energy to one with lower level Relative energy levels indicated by temperature Thus temperature (energy) flows from molecule with high temperature to molecule with low temperature 6

Conduction Figure indicating heat conduction through slab of material The rate of heat flow (Q): k = thermal conductivity A is area over which heat is conducted X is distance through which heat is conducted T 1 & T 2 temperatures either side of the object 7

To increase rate of heat flow: Conduction Increase conductivity k Increase the area, A Decrease the thickness, x Increase temperature difference between two sides of the object (T 1 -T 2 ) Thermal conductivities for Air = 0.03 Wm -1 k -1 Lean meat = 0.5 Wm -1 k -1 Frozen meat = 1.5 Wm -1 k -1 Steel = 43 Wm -1 k -1 Copper = 380 Wm -1 k -1 Thus air surrounding a carcass when not allowed to circulate = a good insulator 8

Movement of air/fluid over surface allows heat transfer Most practical method in which heat transferred from solid to liquid or gas (or vice versa) Two forms: Convection Forced: fan Natural: differences in air density causes flow Rate of air movement determined by temperature differences 9

Refrigeration systems Heat does not flow naturally from cold to hot object To cool object below surrounding ambient temperature need to use some form of refrigeration system Types range from simple to complex (consult refrigeration engineer) Essential principles are similar 10

Cryogenic refrigeration When material changes phase: Solid liquid gas Requires heat additional to the heat required to raise the temperature of the material Latent heat of fusion / melting Latent heat of evaporation / sublimation If you have a material that melts/boils/sublimes at a low temperature, this material will draw heat from surrounding environment in order to change its phase Placing this material in contact with meat product, most of the heat required can be drawn from meat, thus cooling meat 11

Cryogenic refrigeration Materials that melt, boil, sublime at temperatures well below room temperature - known as cryogens Choice of cryogen in meat industry restricted by food safety, quality, environmental considerations: direct contact with food CO 2 & N 2 2 issues make cryogenic refrigeration expensive: Only used once and lost to atmosphere Manufactured using very low temperature processes that require lots of energy

Mechanical vapour compression refrigeration Refine cryogenic process in two ways: Refrigerant not in direct contact with meat but retained inside tubes of an evaporator part of refrigeration system 3 pieces of equipment (compressor, condenser, expansion valve) convert gaseous refrigerant back into a cold liquid that can be recycled around and evaporated again in a continuous cycle 13

Mechanical vapour compression refrigeration Diagram of a mechanical vapour compression refrigeration system. The arrows show the movement of refrigerant around the cycle, driven by the compressor, and the flows of heat and energy into and out of the system 14

Evaporator Point where heat transferred from object being cooled to evaporating refrigerant Simplest way: bring object into direct contact with evaporator Meats do not have flat, parallel sides for plate refrigeration 15

Evaporator Evaporator designed as set of tubes containing refrigerant, with fins mounted outside to increase heat transfer area Air blown by fans across evaporator tubes & fins (where air is cooled), across meat product (cold air warms, meat cooled) and back to evaporator Water/brine better because of their higher heat capacity to volume & greater heat transfer coefficient (liquid & surface vs air & surface) 16

Applications Main application: cool the meat Decreases rate of microbiological spoilage Decreases rate of chemical deterioration Also used as air conditioning: deboning plants Comfortable for staff Decrease bacterial spoilage 17

Rate of development of bacterial slime on meat surfaces at different temperatures Temperature ( C) Time (days) 0 10 1 7 3 4 5 3 10 2 16 1 18

The chilling process Moisture rich material (e.g. meat): process of decreasing temperature (normally around 38 C) to around freezing temperatures of meat (around -1 C for fresh meat) To chill outside temperature must be lower than surface temperature of object being chilled Heat flows away by conduction/convection When surface temp. lower than temp. of deeper parts, these parts will also cool via conduction of heat to the surface 19

Temperature profile and thermal centre Useful to define point in meat where temperature will remain warmest at any time during the cooling process 20

Carcass Geometry of a carcass /side and the interplay of the surface heat transfer coefficient with the geometry are complex thermal centre determined by experience Many temperature measurements during cooling Beef side: deep butt near head of thigh bone Lamb carcass: traditionally deep leg against thigh bone but a quarter way down from pelvis. In practise, slow cooling inside the whole carcass point between thickest part of the shoulder and inside of the cavity (deep shoulder) and between deepest part of the loin and inside surface can take just as long as deep leg to cool down Deep leg measured: associated with highest value cuts 21

The chilling methods Natural convention hot air rises 22

Natural convection Slow Uncontrollable - rate determined by thickness of meat and temperature of the air Rate of chilling can be accelerated by reducing air temp. Limited: if air temperature below freezing temperature of meat meat surface starts freezing product quality 23

Forced convection air chilling Common method Fans blow air over finned tubes containing evaporating refrigerant Cool air passes over warm meat Heated air passes over refrigerant evaporator to be cooled again Changing rate of air flow controls rate of chilling Ensure rate of air flow over carcasses as evenly as possible to avoid large variations in chilling rate Use vanes/slotted ceiling Normally a blast chill cycle followed by a holding cycle 24

a: slotted ceiling b: turning vanes 25

Forced convection chilling Moisture at surface and within carcass can evaporate into the air Air cooled by contact with refrigeration system evaporator coils: humidity typically saturation humidity of air leaving the evaporator Thus absolute humidity of air lower than at surface of carcass Driver for moisture evaporation: diffs between absolute humidity at surface of meat (product of water activity and saturation absolute humidity at surface of meat) and absolute humidity of air passing over meat surface Thus moisture evaporation (weight loss) 26

RH and condensation RH = amount of moisture in air relative to the capacity of air at specific temperature 30 C or can hold 27.2 g kg -1 0 C or can hold 3.8 g kg -1 Early stages, dry air extracts moisture from carcass latent heat of evaporation thus cooling carcass Minimise weight loss high RH Condensation: temp of structures below due point of air in chiller Evaporator drain trays Ducting carrying cold air discharge away from evaporators Areas having intermittent contact with outside air loading door Raising room temp too rapidly prior to deboning to soften fat During rapid loading if evaporators insufficient capacity 27

Achievable cooling rates Function of air temp, air velocity & carcass weights Loading time = 1 hrs kill Longer loading time, difficult to achieve specified cooling rate for first vs last carcass Full capacity of equipment is used for max 4 hrs during initial stage of cooling Estimated cool time for 400kg carcass, heavy fat cover Air velocity m/s Air temp C Cool time (hrs) to: 30 C 20 C 10 C 0.5 0 13.0 20.0 23.5 0.5 6 14.0 23.0 27.5 2.0 0 12.0 19.0 22.0 2.0 6 13.0 21.0 26.0 Conveyorised blast chillers? 28

Air flow distribution Air flow always follows least resistance Anemometers to measure flow Do not overload Part loading uneven air flow

Moisture evaporation Surface of meat dry undesirable appearance Mass of meat product reduced Moisture evaporation increases the effective surface heat transfer coefficient compared with pure convention increasing rate of chilling 30

Weight loss from beef sides in chiller Conditions Good-quality sides % Weight Loss Poor-quality sides 1 d at 0 C + 2 d at 20 C 1.7 3.8 3 d at 0 C 0.7 0.9 14 d at 0 C 1.6 3.2 31

How can moisture loss be avoided? Spray chilling: spraying surface of carcasses with water intermittently during chilling Note regulations for adding weight prior to selling Mixed finding on effect of spray chilling on product surface appearance Either indistinguishable Streaky appearance developed microbial growth 32

33

Product quality Essential requirement is meat tenderness Chill too rapid cold shortening Beef/lamb reach 10 C under 10 hrs Apply correct ES Also minimises two toning (heat ring) Minimise weep Fast chilling deep butt temp < 30 C under 10 hrs Deep butt < 25 C, rate of chilling can be reduced (slow fan speed, increasing refrigerant temp in evaporators) Hot deboning 34

Carcass submersion Chickens Red meat in waterproof wrapping Submersion in cold liquid (brine) Cooled rapidly high heat transfer coefficient found between liquid & solid 35

Visiting an old friend Hot deboning Then stretching and wrapping Advantages Energy saving chiller Higher deboning room temperature Worker comfort Higher yield Mince/processed products straight into process cycle 36

DANKIE / THANK YOU / ENKOSI KAHKULU