Lubrication Systems. Operating Manual Version 1

Similar documents
Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Operating Manual MS220DA

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Translation of the assembly instructions with operating instructions and technical appendix

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

TTV 4500 / TTV 4500 HP / TTV 7000

Original operating instructions Safety switch with guard locking AC901S AC902S

Waste water ejection unit

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

Energy management function at adsorption dryer PDAD

TDS 20 R / TDS 30 R / TDS 50 R

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Copyright LIQUIDYN GmbH 08/2013 Version

Speedpocket. Sewing unit for runstitching of rectangular piped pockets. Operating Instructions. Installation Instructions. Service Instructions

CoMo-Control. Operating Manual. English (translation of original instructions) Documentation no.: a

Explosion Protection Enclosure with integrated measuring system

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Operating Manual. VIENNA Hot Display

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

MANUAL Overflow sensor NVF-104/34-PF

Temperature Sensor TRG Original Installation Instructions English

Snifter ATEX22 VERSION. User Manual. Distributor

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Advance Optima Module Magnos 17

Instruction Manual. Electronic gas and smoke detector GRM

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

MANUAL Oil Level Sensor

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

GMA Panels with double busbar

Flameproof Manual Call Points

Vacuum Controller with Control Unit VC 900

WIO200 Water in oil sensor

GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Operating instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Installation Manual. SiCOMS. Oil mist Concentration monitoring Diesel- and `-Version. Part No.: Release: (revision )

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

Test Unit GTL 100 for Fire Detectors

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

CE Marking and Technical Standardisation

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

ED3002 ED3004 ED3007 ED3030 ED3100

Adsorption dryer PDAD. (en) Operating instructions g [ ]

Operating Manual MS220KA and MSR220KA

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Electronic Temperature Controller 70304,

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

Procedure for the Approval of New Fire Detection and Alarm Technologies

TRG 5-6x. GESTRA Steam Systems. Installation Instructions

Installation and Operating Manual

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

OPTIBAR DP 7060 Supplementary Instructions

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

Monitored Pneumatic Valves On Series Ported Manifold

USER S MANUAL ATH WH220

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Branching and Connection Box AAB. Operating manual AAB EN11. GTE Industrieelektronik GmbH

Manual Power relay SR853

Operating instructions. for radial fans for use in potentially explosive atmospheres

INSTALLATION GUIDE Ultrasonic Sensors Series UPR-A Atex

Conductivity Electrode LRG Original Installation Instructions English

Service package PDAD- -SP (en) Assembly instructions d [ ]

½ Monitored Pneumatic Valve Patented Technology

Laser Distance Sensor Type M Analog-Output

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

Version 1.6. Operating instructions HYDROMETTE BL COMPACT TF 2. Hydromette BL Compact TF 2

Operating Instructions

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

SINAMICS G130. Cabinet design and EMC. Operating instructions 03/2011 SINAMICS

Operating manual. a Look Solutions 1 product

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

½ Monitored Pneumatic Valves On Series Ported Manifold

Instructions for Use

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

SINAMICS G130. Cabinet design and EMC. Operating Instructions 05/2010 SINAMICS

Diaphragm pump 4 - headed

Operating Manual. English. Refrigerators for chemicals KRC 50 KRC 180

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

ST1. Mod. USE AND MAINTENANCE MANUAL

Mechanical seals external, single or double, to DIN EN 12756

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

FSW300 Series Flow Switch

VERSAFLOW VORTEX Supplementary instructions

OPERATING MANUAL CDP 115 Peltier cooling unit for waterbaths

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

Operating instructions

Transcription:

Aerosol Monitor AM1000 Minimum Quantity Lubrication Systems Operating Manual Version 1

Imprint The Operating Manual is a part of the scope of delivery of a SKF aerosol monitor AM1000. The manual has been edited in conformity with applicable standards and rules for technical documentation. Copyright SKF LUBRICATION SYSTEMS GERMANY AG reserves the right to changes to adapt to technical improvements. Reprinting or copying these Operating Instructions as a whole or in parts is only permitted with the agreement of SKF LUBRICATION SYSTEMS GERMANY AG. Editor Dipl.-Ing. J. Schwartz

Kapitel 0 - Contents Seite 1 EN Contents Contents... 1 1 Information Concerning the EC Declaration of Conformity and the Manufacturer s Declaration... 2 2 Notes to the Instructions... 3 3 Field of Application... 4 4 Safety Instructions... 4 4.1 Using the Aerosol Monitor...4 4.2 Personnel...5 4.3 Working on the Aerosol Monitor...5 5 Transport, Delivery, Storage... 6 6 Design and Function... 6 6.1 System Design...6 6.2 Method of Operation...7 6.3 Operation Modes...7 6.3.1 Autonomous Operation with Teach Function... 7 6.3.2 Operation with Connection to the Bus System of a SKF LUBRILEAN Digital Super MQL System... 7 6.4 Functions...7 6.4.1 Laser longlife function... 7 7 Installation... 8 7.1 Configuration...9 7.2 Installation...10 7.3 Connecting the Aerosol Lines...11 7.4 Electrical Connection...12 7.4.1 Supply Voltage and Analog Current Signal... 12 7.4.2 Bus Connection / Teach Adapter... 12 8 Operation...14 8.1 Autonomous Operation...14 8.2 Operation with Connection to the Bus System of a SKF LUBRILEAN Digital Super MQL System...15 9 Maintenance...16 10 Failures...16 11 Decommissioning...18 12 Service...18 13 Technical data...19

Kapitel 1 - Information Concerning the EC Declaration of Conformity and the Manufacturer s Declaration Seite 2 EN D 1 Information Concerning the EC Declaration of Conformity and the Manufacturer s Declaration For the product designated below: Aerosol Monitor AM1000 we herewith certify that it complies with the pertinent safety requirements set forth in the following Council Directive(s) for the harmonisation of the laws of the Member States... Electromagnetic compatibility 89/336/EEC Notes (a) This declaration certifies the conformity with the directives listed, but does not entail an express assurance of properties. (b) The safety instructions listed in the documents that come with the product are to be observed. (c) Putting the certified products into operation is only allowed after it has been ensured that the machine, the vehicle or any other unit in which the product has been installed complies with the regulations and requirements of the applicable directives. (d) Operating the products on a non-standard mains voltage, or ignoring installation instructions can have an effect on the EMC properties and/or the electrical safety. We further declare that the above-mentioned product: has been designed for installation in a machine / for assembly with other machines into a machine in accordance with the EC machinery directive 98/37/EC, Annex II B. Commissioning is not admissible until evidence has been provided that the machine in which this part is installed or to which this part is connected, complies with the regulations set forth in the EC directive 98/37/EC. with reference to the EC directive 97/23/EC concerning apparatus subjected to pressure this product must only be used as intended and in accordance with the notes in the documentation. The following must therefore be observed in particular: SKF products are not suited for use in connection with fluids of group I (hazardous fluids), definition in accordance with article 2 paragraph 2 of the Directive 67/548/EEC dtd. 27th June, 1967; and are not approved for application with such. SKF products are not designed and not approved for any utilization in conjunction with gases, liquified gases, gases dissolved under pressure, vapours, and liquids whose vapour pressure at the maximum permissible temperature is more than 0.5 bars above the normal atmospheric pressure (1013 mbars).

Kapitel 2 - Notes to the Instructions Seite 3 EN 2 Notes to the Instructions When used as intended, the products supplied by us do not reach the limit values listed in the article 3 paragraph 1, sections 1.1 to 1.3 and paragraph 2 of the directive 97/23/EC. They are thus not subject to the requirements of Appendix I of the Directive. Consequently, they do not obtain a CE mark with respect to the Directive 97/23/EG. They are classified by us to come under article 3 paragraph 3 of the directive. SKF products must only be employed in accordance with their intended use. Using the products or putting them into operation in a hazardous area according to ATEX Directive 94/9/EG with a gas atmosphere or a dust atmosphere is not permitted. If required, you may request the declaration of conformity or manufacturer s declaration for this product from our central contact address. The aerosol monitor has been built according to the generally recognized technical standards. It complies with the valid occupational safety and accident prevention regulations. Still hazards may be involved in their use, which can lead to injury of operators or other persons or damage to the machine or other property. To ensure trouble-free operation and prevent hazard, we kindly ask you to read the present manual carefully and observe the notes contained in it. Use the table of contents to locate the desired information promptly and successfully. Please take note of the symbol shown below. It calls attention to special situations: Texts marked by this icon point out specific hazards or identify work that has to be carried out with particular care. These instructions are a part of the unit. They must be handed over to the new user when the unit is sold.

Kapitel 3 - Field of Application Seite 4 EN D 3 Field of Application 4 Safety Instructions All products from SKF LUBRICATION SYSTEMS GERMANY AG may only be used as intended and only according to the specifications in the Operating Instructions that belong to the units. We particularly want to point out that any hazardous materials - in particular substances that are classified as dangerous according to EG RL 67/548/EWG Article 2, Paragraph 2 - may only be filled in SKF products and conveyed and/or distributed with these products after written authorization from SKF LUBRICATION SYSTEMS GERMANY AG has been obtained. No SKF product is approved for being used in conjunction with hot gases, liquified gases, gases dissolved under pressure, vapours and liquids whose vapour pressure at the maximum permissible temperature is more than 0.5 bars above the normal atmospheric pressure (1013 mbars). Apart from the particularly identified products, no product produced by SKF is approved for utilization in hazardous areas. The aerosol monitor is a measuring sensor used for continuously monitoring the aerosol flow of minimum quantity lubrication systems (MQL systems). Although it has specifically been developed for utilization in conjunction with the SKF LUBRILEAN Digital Super MQL system, it may as well be used independently of this system. Other use or use beyond this purpose is considered unintended. SKF will not accept liability for damages resulting from such unintended use. Please observe the following safety instructions in order to ensure a troublefree functioning of the aerosol monitor and to avoid damages. 4.1 Using the Aerosol Monitor The aerosol monitor may only be used as intended, when it is in a technically faultless state, in a safety- and hazard-conscious way and when the Operating Instructions are observed. Especially errors that could affect safety must be resolved without delay. Contact a SKF service centre (see Chapter 12, page 18) for this purpose. The aerosol monitor is intended to be used in conjunction with a minimum quantity lubrication system (MQL system). All safety instructions listed in the Operating Instructions of the MQL system must therefore be observed when the aerosol monitor is used within the MQL system. The aerosol monitor employs a class-1 laser which does not represent any risk when the unit is used as intended. However, do not look into the laser beam, and do not insert strongly reflecting objects into the aerosol channel. Unauthorized modification of the aerosol monitor and using unapproved spare parts and auxiliaries are not permitted, and would lead to losing the warranty. Units that can no longer be used must be made unusable and disposed of properly.

Kapitel 4 - Safety Instructions Seite 5 EN 4.2 Personnel The installation, electrical connection and all interventions such as repairs, component replacement, etc. may be carried out only by adequately qualified and instructed personnel. There can be significant damage and injuries when the aerosol monitor is connected improperly. Qualified personnel has been trained, instructed and specifically ordered by the owner to perform the work. Due to their training, experience and instruction, these persons are familiar with the applicable standards, regulations accident prevention regulations, and operating conditions. They are authorized to carry out the necessary activities, and are able to recognize and avoid possible hazards. The definition for qualified personnel and the prohibition of the employment of non-qualified personnel are stipulated by DIN VDE 0105 or IEC 364. 4.3 Working on the Aerosol Monitor The aerosol monitor is installed in the aerosol line of an MQL system. Any work that is carried out during the installation on the aerosol monitor, for example, thus requires the safety instructions in the Operating Instructions of the MQL system to be observed. CAUTION DANGER OF LIFE Prior to starting any installation, service or repair work, the corresponding experts must disconnect the power to the system. Working on MQL systems that are not de-energized may lead to personal injuries. Prior to starting any installation, service or repair work, the MQL system must be separated from the compressed air supply. Working on systems under pressure could lead to personal injuries.

Kapitel 5 - Transport, Delivery, Storage Seite 6 EN D 5 Transport, Delivery, Storage 6 Design and Function The aerosol monitor is packed in commercial standard packing according to the requirement of the destination country and of DIN ISO 9001. 6.1 System Design There are no limitations for road, air or sea transport. Upon receiving the package, please check the items for possible damage, and ensure the package is complete by checking the supply papers. Keep the packaging material until any and all problems have been clarified. Generally, units should be stored in dry and dust-free environment. The storage temperatures can be found in the specifications. Fig. 1. Design of the aerosol monitor 1. Connections for aerosol lines 2. Connection for supply voltage and analog signal 3. Connection for bus link or teach adapter 4. LED indicator for operating voltage 5. LED indicator for signals 6. LED indicator for bus communication 7. Bottom lid (access to DIP switches) 8. Boreholes for fixture

Kapitel 6 - Design and Function Seite 7 EN 6.2 Method of Operation The aerosol monitor is a scattered-light monitor that is installed in the aerosol line between aerosol generator and lubrication point of an MQL system. There it measures the density of the aerosol produced by the MQL system. In the SKF terminology, the term aerosol in minimum quantity lubrication technique stands for air mixed with finest lubricant droplets. The aerosol density is the quantity of the oil contained in the aerosol, related to the air flow. The aerosol monitor supplies a measured analog signal that can be employed for controlling the aerosol production. If the oil content in the aerosol drops at a constant air flow, the aerosol density and, consequently, the measured signal drop, too. The measured signal remains constant if air stream and aerosol-oil throughput change equally. Thus, the measured signal represents the concentration of the oil in the air that flows along the monitor, not for the absolute oil quantity contained in the air stream. 6.3 Operation Modes 6.3.2 Operation with Connection to the Bus System of a SKF LUBRILEAN Digital Super MQL System The aerosol monitor features a bus interface via which the monitor can be connected to the bus system of a SKF LUBRILEAN Digital Super MQL system. This provides the MQL system with information, such as the aerosol-oil volume flow, that permit the aerosol generation to be optimized. 6.4 Functions 6.4.1 Laser longlife function The laser is switched off automatically when the aerosol monitor detects that aerosol does not flow through the measuring chamber and the signal approaches zero. Next, the aerosol monitor checks at 10-second intervals whether there is aerosol in the line. The laser is switched back on as soon as aerosol flows through the measuring chamber. Note: This function is particularly suitable for slow processes to which a signal delay of up to 10 seconds is not relevant. 6.3.1 Autonomous Operation with Teach Function The aerosol monitor can also be used in stand-alone mode, i.e. without a connection to a SKF LUBRILEAN Digital Super MQL system. To be able to use the full range of the measured signal in this case, you can define a measurement range whose highest and/or lowest value correspond to the highest and the lowest value, respectively, of the measured signal (teaching).

Kapitel 7 - Installation Seite 8 EN D 7 Installation Use the following flow chart to carry out installation and commissioning of the aerosol monitor: Configuration Erection Connecting the aerosol lines Electrical connection and settings Installation work may only be carried out on the previously de-energized and de-pressurized MQL system. The aerosol monitor may only be installed and connected by properly qualified and instructed personnel. The safety instructions in the Operating Instructions of the aerosol monitor and the MQL system are to be observed.

Kapitel 7 - Installation Seite 9 EN 7.1 Configuration The unit must be configured via DIP switches on the board if it is to be connected to the internal bus system of the LUBRILEAN Digital Super MQL system. De-energize the unit, screw off the bottom lid, and remove the seal. Use the following table to select the configuration required for your application. Additional notes and explanations can also be found in Chapter 7.4.2, page 12. Carefully install seal and bottom lid after you have set the DIP switches. Please note, that the configuration of the related control unit of the LUBRILEAN Digital Super also have to be adjusted. Please refer to the related Operating Instructions and/or contact a SKF service centre to find the necessary settings. Fig. 2. View on the DIP switches. Bottom lid removed. Table 1. Configuration of the DIP switches Illustration DIP No. Status Default ex factory Action Setting 1 ON X Bus termination active OFF inactive ON 2 ON Target system for bus data 2nd control unit in UFD20-02x OFF X 1st control unit in UFD20-02x or UFD10-02x 1 2 3 4 3 ON not used - OFF X - 4 ON Laser longlife function active OFF X inactive

Kapitel 7 - Installation Seite 10 EN D 7.2 Installation The aerosol monitor should be installed on a vertical surface such that the aerosol lines run horizontally. The location of the monitor must remain the same during operation. The aerosol monitor should be installed such that it is protected against humidity and vibration, and easily accessible so that any further installation is possible without any problems. All visual indicators should be clearly visible, all control elements easily accessible. Do not install the monitor in the vicinity of a heat source. Ebenfalls ungeeignet ist ein Ort, der schnellen und starken Temperaturschwankungen ausgesetzt ist. We recommend to install the monitor directly on the machine housing. Die Einbaumaßen sind den entsprechenden Kundenzeichnungen zu entnehmen. Fig. 3. Aerosol monitor with installed lines

Kapitel 7 - Installation Seite 11 EN 7.3 Connecting the Aerosol Lines Prior to installing the aerosol lines to the aerosol monitor you must depressurize the MQL system. 1. Shift the union screw and the tapered ring onto the pipe end as shown in the figure. Aerosol monitor features screwed connections for hoses Ø 12x1 (outside Ø x wall thickness). 2. Guide the pipe end into the hollow until it hits the stop. Only pneumatic hoses which are resistant to the lubricants used and will withstand an operating pressure of least 10 bars may be used. The aerosol monitor is installed in the aerosol line, between MQL system and lubrication point. This may require the hose to be separated. Use the screwed fittings to connect the hoses (Fig. 4). Fig. 4. Threaded hose coupling 3. Tighten the union screw manually. Continue turning it by a maximum of 1 ½ revolutions. We recommend using transparent hoses, which should be screened against the ambient light at a length of approximately 20 cm before and after the aerosol monitor in order to ensure an optimum signal response of the monitor. Sufficient screening can be achieved by an additional hose sheath, for example. Guidelines and recommendations for laying the aerosol lines can be found in the Operating Instructions of the related MQL system. Please contact a SKF service centre if you have any other questions when you install your MQL system (see Chapter 12, page 18).

Kapitel 7 - Installation Seite 12 EN D 7.4 Electrical Connection The electrical connection of MQL system and aerosol monitor may only be established by appropriately qualified and instructed specialist staff. Comply with the notes in this operating manual. Please refer to the installation drawing and/or the leaflet of the aerosol monitor for recommended accessories for the electrical connection. 7.4.1 Supply Voltage and Analog Current Signal The left-hand connector of the aerosol monitor (male connector) is provided for connecting the operating voltage and the analog signal output. The pin assignments are listed in the table below. The aerosol monitor is operational and the operating voltage LED is ON as soon as the supply voltage is applied. 7.4.2 Bus Connection / Teach Adapter The right-hand connector of the monitor (female connector) is provided for connecting the bus link to the SKF LUBRILEAN Digital Super MQL system or the teach adapter. Connect the bus cable (accessory) to establish the link to the SKF LUBRILEAN Digital Super MQL system. When using the UFD20-02x, you must connect an aerosol monitor with a control unit of the MQL system. A common bus is established, since the control units of the MQL system are already interconnected with each other (Fig. 5). The line is always terminated at the end of the bus. The left-hand picture (Fig. 5) thus requires the line termination in the LUBRILEAN Digital Super control unit and in the aerosol monitor to be activated. Contact Used for Male connector* 1 Wire colours* 2 Pin 1 + 24 VDC Brown Pin 2 4..20 ma 5 White Pin 3 0 V (GND) 4 3 Blue Pin 4-1 2 Black Pin 5 - Yellow-green Table 2. Pin assignments for operating voltage and analog signal * 1 View onto the connector * 2 When using a pre-fabricated M12x1 cable Fig. 5. SKF LUBRILEAN Digital Super MQL systems with connected aerosol monitor left: UFD10-02x, right: UFD20-02x

Kapitel 7 - Installation Seite 13 EN In the right-hand picture, the termination resistors in the LUBRILEAN Digital Super control units are to de deactivated, and the ones in the aerosol monitors are to be activated. The termination resistor of the aerosol monitor is activated via a DIP switch at the bottom of the monitor (see Chapter 7.1, page 9). The teach adapter (accessory) can be connected to the right-hand connector of the aerosol monitor. The adapter can be used for adjusting the monitoring range of the aerosol monitor. To connect the teach adapter you must remove the screwed lid on the right-hand connector. Once you have completed the teaching process, remove the teach adapter and reinstall the lid. A bus line connected to the right-hand connector must be removed during the teach process, and be reconnected after teaching has been completed.

Kapitel 8 - Operation Seite 14 EN D 8 Operation Note: The colour of the signal LED shows the range of the measuring range the current aerosol density is in: 0 25 % signal LED is OFF. >25-50 % signal LED lights white >50-75 % signal LED lights green >75 % signal LED lights blue The aerosol monitor can be used in two different modes: Autonomous operation Operation with connection to the bus system of a SKF LUBRILEAN Digital Super MQL system 8.1 Autonomous Operation When the aerosol monitor is used in autonomous mode, an analog current signal (4...20 ma) is available that is related to the actual analog density. This signal can be used, for example, to generate a warning message when the measured values deviate from the specified reference values. To be able to use the complete measuring range of 4 20 ma, we recommend the setting of limit values of the aerosol density in the aerosol monitor. This process is known as "Teaching". To carry out teaching, connect the teach adapter (accessory) to the right-hand connector of the aerosol monitor, and carry out teaching according to the instructions in Table 3. Table 3. Teaching the analog signal Action Prerequisite Operation LED response Setting the maximum value (high teach) Setting the minimum value (low teach) Resetting the values to the factory setting Aerosol flows at the maximum set analog density Aerosol flows at the minimum permitted analog density None Press the button on the teach adapter 2x in short succession Press the button on the teach adapter 1x long (approximately 1s), until the signal LED lights green Press the button on the teach adapter until signal LED and bus LED light up. Release the button. with successful teach-in Signal LED blinks 4x blue Signal LED blinks 3x green Signal LED blinks 4x blue and BUS LED blinks 4x white with faulty teach-in Signal LED blinks 6x red Signal LED blinks 6x red Signal LED blinks 6x red

Kapitel 8 - Operation Seite 15 EN 8.2 Operation with Connection to the Bus System of a SKF LUBRILEAN Digital Super MQL System When the aerosol monitor is connected to the bus system of a SKF LUBRILEAN Digital Super MQL system, the measured values are transferred via the bus link to the control unit of the MQL system where they are processed to yield additional characteristic variables (see Table 4). The MQL system transfers these variables to the control system of the machine tool. Comparing the measured results with the previously determined reference values enables the user to determine and assess significant deviations. Figure 6. Aerosol monitor with teach adapter Operation with the BUS system requires a software version 17 or higher at the control unit of the SKF LUBRILEAN Digital Super MQL system. Please contact a SKF service centre for software updates. Table 4. MQL parameters in bus communication Parameter Value range Air volume flow 0...600 Nl/min Aerosol-oil volume flow 0...65355 [without unit] Aerosol density 0...1000 [without unit]

Kapitel 9 - Maintenance Seite 16 EN D 9 Maintenance 10 Failures Maintenance work may only be carried out by adequately qualified and instructed specialist staff. Maintenance work may only be carried out on an MQL system that was de-energized before by competent specialist staff. Working on an energized system may lead to personal injuries. The aerosol monitor requires little service. However, in order to ensure faultless functioning and to prevent dangers from arising, check all connections and joints regularly. Faultless functioning of the aerosol monitor requires the following prerequisites to exist: The system has been connected correctly. The bus link has been installed properly. The MQL system has properly been configured and is equipped with the correct software. The machine tool is switched on. Provided that there are no malfunctions in the system itself, any other faults can usually be eliminated quickly. Any work not described in these Instructions may only be carried out by authorized SKF service personnel. SKF LUBRICATION SYSTEMS GERMANY AG does not assume any responsibility for damages that are caused by improper maintenance on the aerosol monitor or MQL system.

Kapitel 10 - Failures Seite 17 EN Table 5 gives an overview of various problems you can eliminate yourself. You should contact us if the problem cannot be rectified by taking the measures described here. When using the unit with a SKF LUBRILEAN Digital Super MQL system, faults different to the listed error messages of the control unit are not due to faults of the aerosol monitor. Please refer to the Operating Instructions of the SKF LUBRILEAN Digital Super MQL system for details. Table 5. Possible faults when using the aerosol monitor Fault Possible cause Remedial action Autonomous operation or operation with connection to the bus system of a SKF LUBRILEAN Digital Super MQL system Analog value always 4 ma No aerosol No sensible teach setting (aerosol density high teach < low teach) Check the MQL system Reset the teach values to the factory setting (see Chapter 8.1, page 14) Operation with connection to the bus System of a SKF LUBRILEAN Digital Super MQL system The control unit of the LUBRILEAN Digital Super shows the following error codes BUS LED doesn t glow E 50 E 60 Software of the control unit of the SKF LUBRILEAN Digital Super MQL system does not correspond with version 17 or higher The aerosol monitor is not recognized by the control unit of the UFD10-02x or by the 1st control unit of the UFD20-02x The aerosol monitor is not recognized by the 2nd control unit of the UFD20-02x. Update the software version Check the bus cable connections Check whether DIP switch 8 in the control unit of the DigitalSuper is ON. If not, set it to ON. Check whether DIP switch 2 in the aerosol monitor is OFF. If not, set it to OFF. Check the bus cable connections Check whether the PROFIBUS address in the 1st system of the UFD20-02x is 0. Check whether the PROFIBUS address in the 2nd system of the UFD20-02x is 0. Check whether DIP switch 8 in the 2nd control unit of the UFD20-02x is ON. If not, set it to ON. Check whether DIP switch 2 in the aerosol monitor is ON. If not, set it to ON.

Kapitel 11 - Decommissioning Seite 18 EN D 11 Decommissioning 12 Service When decommissioning the aerosol monitor and disposing of it you must always observe the legal provisions for disposing of components that contain lubricants. Upon request, SKF takes the unit back for disposal and will charge you for the incurring costs. Please contact our sales offices or our international representatives if you have any questions or problems. You can find a list of the current addresses on the Internet at: www.skf.com/schmierung

Kapitel 13 - Technical data Seite 19 EN 13 Technical data Table 6. Technical data Designation Unit Value Fluid - Aerosol for MQL Operating pressure, aerosol bar 4... 10 Connection for aerosol line - for hose Ø12x1 Ambient temperature C + 10... + 60 Protection rating to DIN EN 60529 - IP 54 Operating voltage V DC 24 ± 25% Current consumption idle under load ma ma max. 60 max. 80 Analog signal ma 4... 20 Load for analog current signal Ω max. 400 Operation with the BUS system requires a software version 17 or higher at the control unit of the SKF LUBRILEAN Digital Super MQL system. Please contact a SKF service centre for software updates.

Kapitel 13 - Technical data Seite 20 EN D

Notes EN

Notes EN

Notes EN

Notes EN

SKF Lubrication Systems Germany AG Motzener Straße 35/37 12277 Berlin Postfach: 970444, 12704 Berlin Telefon: (++49) 30-7 20 02-0 Fax: (++49) 30-7 20 02-111 E-Mail: lubrication-germany@skf.com WWW: www.skf.com/schmierung 951-130-315 29th April, 2009