FIRE DOOR CLOSING SYSTEMS

Similar documents
FIRE DOOR. AlarmGard & FireGard. Preferred door solutions.

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

FireCurtain STANDARD, gray, with steel slats UL & C-UL LISTED. Phone: RAYNOR Fax:

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635

SECTION OVERHEAD COILING FIRE DOORS

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION Overhead Coiling Doors

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

ROLLING SERVICE FIRE. Product Line COUNTER FIRE INTEGRAL FRAME & SILL FIRE INDUSTRY LEADING COMMERCIAL & INDUSTRIAL SOLUTIONS

SECTION OVERHEAD COILING FIRE DOORS 640 SERIES OVERHEAD COILING COUNTER FIRE DOORS

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

MANUAL RESET ALARM RELEASE

UNDERSTANDING SAFETY CABINETS

INSTALLATION & MAINTENANCE CORNELL FIREGARD CHAIN & ES ECO #1515 REVISION # 0000 FIREGARD CRANK OPERATORS BY: RICKM DATE: 3/23/2011

MD Series MEDIUM DUTY SERVICE DOORS. superior product + recognized value

MANUAL RESET ALARM RELEASE

M O D E L S FIREGARD BV EXTENDED PERFORMANCE RELEASE DEVICE

SAFEPATH SAFEPATH. Emergency communications system

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

AL800ULADA. NAC Power Extender. Installation Guide

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

MAX ARM. Heavy Duty Linear Actuator for Residential / Commercial use. Super quiet Solar ready Large diameter stainless steel output shaft

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Fire Sprinkler Plan Submittal Form

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

Life safety notification

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

R OL L ING F IR E DOOR T E S T ING P R OGR AM

Dependable Solutions for Gas Detection

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

Get Your Firehouse Connected with the Next Generation of Commercial Door Operators from LiftMaster.

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

AUTOCALL FIRE DETECTION SYSTEMS.

TrueAlert Multi-Candela Notification Appliances

Smoke and Fire Curtains

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

Operation & Maintenance Manual

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

Bi-Directional Barrier Arm Turnstile

NFPA 80 Overview January 21, 2016

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

Innovative protection that combines power and flexibility

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

Product datasheet High speed door Albany HS9010PEM. ASSA ABLOY Entrance Systems

Addressable Fire Alarm Control Panel

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

Full Service Central Station Fire Alarm Listing Evaluation

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

csw-200 intro d u c t i o n

Hand Chain (Model FCF) &

Intelligent Earliest Warning Aspirating Fire Detector

Across-the-Line SERIES MP300 Combined Manual and Automatic

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

Residential Fire Protection

The Standard In Safety

good things in small packages

rpsa FIRE PROTECTION ENGINEERS

Conceal-Alarm Series FA100 & FA900. ETL listed to UL standards UL1971, UL1480, UL464

Firetex steel fire shutters

TrueAlert Notification Appliances

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Vibratone Horns. Models 350 and 450

GENERAL AREAS OF INSPECTION

OWNER S MANUAL MODEL FDCL C

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

High Speed Door ASSA ABLOY UltraFast

Variable Frequency Drive SERIES MP800 VFD

Safety Tips for the Office

FIRE FIRE FACT NO. 057 CHECKLIST(s) : Rev. 11/2006 TITLE : CHILD CARE HOMES CHECKLIST ITEM(s) : REFERENCE(s) : K.S.A

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

AL600ULADA. NAC Power Extender. Installation Guide

Objective 1: Describe fire alarm systems.

MODEL B2 INSTALLATION MANUAL

Soft Start Series MP700 Solid State, Reduced Voltage

CHIMNEYS AND VENTS CHAPTER 8

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

Distributed By: M&M Control Service, Inc Building Technologies

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Fire Safety and Whole Home Protection

ELECTRONIC SOUNDER STROBE Model : AVD-C407

THE INTELLIGENCE BEHIND THE MOST INNOVATIVE FIRE DETECTION SYSTEMS

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

Transcription:

FIRE DOOR CLOSING SYSTEMS AlarmGard & FireGard

PREVENT SMOKE AND FIRE DAMAGE According to the National Fire Protection Association (NFPA), in 2014, there were 1,298,000 fires reported in the United States. These fires caused 3,275 civilian deaths, 15,775 civilian injuries, and $11.6 billion in property damage. Our fire solutions help save property, and more importantly, lives. With our advanced Fire Door Systems offering industry-leading, intelligent operation and will: Activate thermally or electrically to contain fire and stop smoke migration Easily - or even automatically - reset or auto open after a fire event or power outage Our Rolling Fire Doors are the clear and reliable choice for building owners and designers who demand the highest level of life safety and fire protection available with the lowest cost of ownership in a modern, easily integrated package. 2

ROLLING FIRE DOORS Custom Built for Everyday Use Our Rolling Fire Doors, designed for fire rated openings, provide security and access control for use in openings that are not part of a required means of egress. Factory Mutual Approved and listed with the California Office of the State Fire Marshall. UL listed for fire protection ratings of 3/4, 1 1/2, 3 and 4 hours. STANDARD COMPONENT MATERIALS AND FINISHES Curtain Galvanized steel with GalvaNex finish in Gray, Tan, White or Brown Bottom Bar Steel with powder coating in Gray, Tan, White or Brown Guides Counterbalance Shaft Steel with powder coating in Gray, Tan, White or Brown Steel Brackets Steel with powder coating in Gray, Tan, White or Brown Hood Galvanized steel with GalvaNex finish in Gray, Tan, White or Brown OPTIONAL MATERIALS AND FINISHES Stainless steel SpectraShield powder coating in more than 180 colors ADDITIONAL BRACKET AND GUIDE OPTIONS Hot-dip galvanizing on steel components Zinc enriched corrosion resistant powder coating in gray. POPULAR OPTIONS PERFORMANCE UPGRADES Vision Windows Custom Graphics Wind Loading SmokeShield - UL 1784 S Label assembly provides protection against the infultration of smoke and gases. Firemiser Insulated Rolling Fire Doors - Provides energy savings, sound attenuation and climate control. STC rating of 32. Flame spread and smoke development index 0. 3

RATED COUNTER SHUTTERS Custom Built for Everyday Use Our Rolling Counter Shutters protect interior corridors and create structural seperation in openings where lifesafety is a priority. For use in rated walls, masonry or dry wall with metal or wood studs, our counter shutters can also be used to close full-sized door openings when compact components are required. UL listed for fire protection ratings of 3/4, 1 1/2, and 3 hours. STANDARD COMPONENT MATERIALS AND FINISHES Curtain Galvanized steel with GalvaNex finish in Gray or Tan Bottom Bar Steel with powder coating in Gray or Tan Guides Counterbalance Shaft Steel with powder coating in Gray or Tan Steel Brackets Steel with powder coating in Gray or Tan Hood Galvanized steel with GalvaNex finish in Gray or Tan OPTIONAL MATERIALS AND FINISHES Stainless steel SpectraShield powder coating in more than 180 colors ADDITIONAL BRACKET AND GUIDE OPTIONS Zinc enriched corrosion resistant powder coating in gray. POPULAR OPTIONS PERFORMANCE UPGRADES Rated Counter Top Vision Windows Custom Graphics SmokeShield - UL 1784 S Label assembly provides protection against the infultration of smoke and gases. Integral Frame and Sill - Factory-welded frame and sill configuration for a built-in look. Available in UL labels for 3/4 or 1 1/2 hours. 4

THE IMPORTANCE OF CHOOSING THE RIGHT FIRE DOOR CLOSING SYSTEM Fire doors are mandatory. A closing system can be custom tailored to your needs. Why not choose one with the features that truly benefit the owner long after the installation is complete? ALARMGARD Alarm Activated Select AlarmGard if you want the most advanced closing system that closes your doors as soon as fire is detectd and features hands-free reset. FIREGARD Fusible Link Activated Select FireGard if you wnat a fusible link closing system that is economical and easy to use. FUNCTION BENEFIT MOTOR TUBE MOTOR* CHAIN OR CRANK MOTOR CHAIN OR CRANK Wires directly to fire alarm control panel without adding a separate release device Integrated connection to create a cleaner look and simplified installation Automatically resets upon alarm clearing or restoration of power Doesn't require human interaction to reset to fully operational status Automatic close initiated by signal from fire alarm control panel Closes in advance of smoke or high temperatures reaching the opening - compartmentalizing the fire O O Operates fail-safe Performs its intended function in the event of power loss or electrical notification (fusible links are not fail-safe) O O Automatic close may be initiated by fusible link Suitable where connection to alarm system is not required or power is not available O O O Does not require manual resetting of spring tension after closing Eliminates downtime and maintenance costs associated with resetting process Allows for routine and simple testing of system to occur in minutes Can be tested at floor level with no need for hazardous ladders or resetting tools O O May be retrofit to other manufacturers doors Gain the benefits of our advanced closing systems without requiring a new fire door and keep existing UL or FM labels Controlled and safe rate of descent 9-12 ips Prevents potential danger to building occupants or objects in the opening when the door closes * Available for Counter Fire Doors x Available as a Standard o Available as an Option 5

CLOSING SYSTEM RELEASE DEVICES Automatic Response in an Emergency If a fire or smoke event occurred in the school pictured here, you would want your fire doors to immediately react to the central alarm signal, causing them to close and prevent the spread of smoke and fire so students could exit safely. Our fire door closing systems can be ordered with an integrated or optional release device, which will respond immediately when the alarm signals and when you need it most. AlarmGard Integrated Fail-Safe Release Device INTEGRATED RELEASE DEVICE On-Board Closing Device The AlarmGard Closing System comes already equipped with an integrated fail-safe release device, making it the superior choice for application where there is minimal wall space for additional devices, or where the coil box must be recessed into the ceiling construction. Activates Door to Close from Alarm Signals Does Not Require Human Interaction to Reset or Re-Open after Alarm Clears Requires Minimal Headroom Clearance Faster Installation Times Clean, Streamlined Appearance FireGard Optional Release Device OPTIONAL RELEASE DEVICE FUSIBLE LINKS Wall Mounted Closing Device The FireGard Fusible Link Closing System can be ordered with an optional fail-safe release device, which will respond to alarm signals and permit the fire door to close before smoke migration occurs or before high temperatures melt the fusible link. The FireGard optional release device is suitable for applications that can offer more wall space for the installation of the device and where aesthetics are less important. 6

CLOSING SYSTEM ACCESSORIES Available for both AlarmGard and FireGard Closing Systems A variety of accessories are available to enhance the safety and functionality of a Rolling Fire Door or Counter Shutter. Battery Backup Device The addition of a battery backup device to the fail-safe release device prevents unplanned door closure due to power failure. The device also functions as a backup power source for local warning devices and detectors during power failures. Entrapment Protection Devices To meet the UL 325-2010 standards for safety, doors without a monitored and properly functioning primary entrapment device will only function by constant pressure to close. Wireless Sensing Edge Contact with the edge during the close cycle causes the door to immediately stop downward travel and reverse direction to the fully open position. Photo Eyes Interruption of the safety beam during the close cycle causes the door to immediately stop downward travel and reverse direction to the fully open position. Floor Level Test Stations Safely and conveniently test and reset the functionality of the fire door at floor level. May be flush or recess mounted. Fire Door Annunciators ADA compliant safety devices provide a visual or audible advanced warning when the door is about to close. Can be supported by a battery backup device. Voice Warning Module Provides up to four different voice warning messages upon activation. Horn Strobe Visual strobe warning light powered by the release device. 7

ALARMGARD Model ERD10 The Most Advanced and Complete Fire Door Closing System Activated by fire alarm systems or local detectors, this closing system features an integrated release device for an immediate, fail-safe response to a fire event, even in the event of a power failure. AlarmGard Operating System Benefits Compact Design Includes Integrated Fail-Safe Release Device Automatic Reset Plus Automatic Open Eliminates Reset Downtime by 100% after Alarm Clears Operated Spring Tension Not Released Upon Activation Safe, Controlled Activated Closing speed of 9-12" Per Second Minimum Clearance Requirements Motor Operated AlarmGard System These advanced systems close the fire door in response to an alarm signal and are fail-safe by design, safely closing the door during a fire even or prolonged power failure. When the alarm is cleared and power is restored, the door is automatically reset. AlarmGard operators do not require an optional release device. AlarmGard is especially beneficial in recessed applications because there is no need for direct access to the closing system to reset the door. Retrofit Operators The AlarmGard operating system can be retrofit to most manufacturers' fire doors while maintaining the door's listing agency ratings. 8

AlarmGard Tube Motor Operator For Fire Doors and Counter Fire Shutters AlarmGard Tube Motor Operators are concealed in the shaft assembly, making them ideal for openings with tight clearances or when you need to conceal the operator drive components without adding a bulky and unsightly motor cover. The AlarmGard Tube motor operator can be used on Fire Doors or Counter Fire Shutters. Features and Benefits: Convenience of motor operation in a low-profile, concealed design Auto-Reset and selectable Auto-Open Available with or without battery back up UL 325 compliant and UL 864 listed motor assembly Rated for up to 10 cycles per day Electrical connections from the operator to wall-mounted control panel is plug and play Internal fail safe release device and internal centrifugal governor Recommended Applications: Fire Door and Counter Fire Shutters that require convenient motor operation in limited spaces conditions Conditions that will benefit from hidden components and aesthetically pleasing profile Applications requiring a back-up battery to eliminate nuisance activations from power interruptions Requirements: An AlarmGard tube motor can operate a fire door or fire counter shutter up to approximately 120 sq ft.* The tube motor requires 120 V ac/60 Hz or 230 V ac/50 Hz** input power and 24 V alarm input * Size limit varies by door configuration and gauge required. ** Special order - additional lead time will apply. Chain and Crank AlarmGard Systems Economical Function: Even with manual modes of operation, the advanced AlarmGard system includes an integrated fail-safe release device that electrically activates and automatically resets the door. Resetting spring tension or re-engaging the operator is not required Recommended Applications: Use for fire products that do not require the daily operating convenience of a motor operator. Clearance and access to the hand chain or crank eye is required Requirements: The chain and crank requires 120 V ac input power and 24 V alarm input 9

FIREGARD Model ERD10 Save Time and Money on Daily Operation, Testing and Resetting The FireGard s convenient and economical design is thermally activated. This system can be readily drop tested and reset with minimal downtime - dramatically reducing labor and inspection costs. FireGard Operating System Benefits Activates without Releasing Spring Tension Fusible Link Activation Standard Safe, Controlled Closing Speed 9-12" Per Second Will Not Automatically Close Upon Power Failure Compact Design Easy Installation Connection to Alarm System (Optional) Floor Level Test Station (Optional) Motor Operated FireGard System Features and Benefits: Convenience of motor operation Auxiliary chain for emergency operation Simple and inexpensive annual testing Chain and Crank Operated FireGard System Features and Benefits: Power not required Economical Simpole and inexpensive annual testing Retrofit Operators The FireGard operating system can be retrofit to most manufacturers' fire doors while maintaining the door's listing agency ratings 10

A FULL LINE OF ADVANCED FIRE DOOR CLOSING SYSTEMS With quality and reliability as our first priorities, our innovative fire door systems offer industryleading functionality and intelligent operation. Visit our website for more information on features, options and finishes available for our rolling fire doors and shutters. A NETWORK OF LOCAL DEALERS TO PROVIDE SUPERIOR SERVICE Whether you want to install a new closure system or are looking to service currently installed products, our Local Dealer Partners are trained and equipped with the tools and resources to ensure your satisfaction. ARCHITECTURAL DESIGN SUPPORT Our experienced Architectural Design Support Team is available to help you customize our products and develop uniquely engineered solutions to fit your specific design needs. MAKE OUR YEARS OF SUCCESS A PART OF YOURS Family owned and run since 1828, our expert design teams and ISO registered state-orthe-art facilities are focused on providing quality closure solutions that protect lives and property. Contact architecturaldesignsupport@cornellcookson.com or call 1.800.233.8366 ext. 4551 for design support. FOR MORE INFORMATION AND TECHNICAL DETAILS, VISIT CORNELLIRON.COM/FIRE 11

Your Authorized Cornell Dealer: 800.233.8366 cornelliron.com/spectrashield CornellCookson, LLC is an ISO 9001:2015 registered company 02.2019