Swing Door Operator EM EMSW

Similar documents
Motorised swing doors User manual (translation of the original instructions) IP2225EN

Ditec DAS107PLUS User Manual IP2270EN.

Swedish Technical Approval SC

Besam SW200i-Fold Folding Door Series. Owner s Manual

Ditec DOR Folding doors operator

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

23-IN Electric Logset

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Wireless Home Appliance Timer Remote Control Kit

IMPORTANT SAFETY INFORMATION

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Please Keep This Manual For Future Reference REV.01

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

The New EMC Directive 2004/108/EC

Original instructions Sense7-series Non-contact coded safety switch

Instruction Manual for Electric Ovens OO757X OO986X

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

Split System, 18,000-48,000 Btu/h Underceiling Type MCC Series 50 Hz

AUGUST 2016 CONTENTS:

FV-11VQL6. Thank you for purchasing this Panasonic product Back cover FV-15VQL6

General safety precautions English

TECHNOLOGY CORP. Taking a bite out of energy costs. Instruction Manual for the ORKA Remote Thermostat/Humidity Controller.

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Honeywell Temperature & Humidity Sensor with LCD

Operation and Maintenance Manual

Table of Contents. What s in the Box... 3 Power Requirements... 4 Quick Setup... 5 Lighting Guide With Ring, you re Always home.

General safety precautions English

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

1125 PIR Motion Detector

Operating Manual. VIENNA Hot Display

Ropox Bathtub. Keep this manual with the product at all times! User Manual & Mounting Instructions PDF 6128 /

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

COMBINATION ELECTRIC FIREPLACE/HEATER Model #FP23-1A-AKM

Blueair Classic. User Manual series

IMPORTANT SAFETY INSTRUCTIONS

Installer: (Name, address, telephone)

General safety precautions English

EVAPORATIVE COOLER W

Edition 8, From serial no Publ. no OM 5030, Orwak 5030 OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Homeowner s Installation Instructions & Operating Manual

Wireless Rain Gauge with Indoor Temperature

Installer: (Name, address, telephone)

Installer: (Name, address, telephone number)

Ditec QIK80EH Electromechanical barrier (Translation of the original instructions)

Kitchen Appliance Lift INSTRUCTION MANUAL

ISCG90SS _03 ISCG90SS

hc3 OWNER S MANUAL OMHC3US2016/07E

Installer Guide smart connect

Blueair Classic. User Manual - 500/600 series

General safety precautions English

General safety precautions English

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

CONTENTS QUICK REFERENCE GUIDE PROGRAMME CHART

POWERSHRED. 99Ci. Quality Office Products Since Please read these instructions before use. Do not discard: keep for future reference.

Conserve Socket Power Timer. User Guide

Installer: (Name, address, telephone number)

Installer: (Name, address, telephone)

Installer: (Name, address, telephone number)

The European Radio Equipment Directive 2014/53/EU

General safety precautions English

The Impact of Marking Requirements. on Design and Performance of Power Converters and Electrical Drives

Homeowner s Installation Instructions & Operating Manual

Edition 8 From serial no Publ. no OM 5030NHD; Orwak 5030-NHD OPERATING INSTRUCTIONS (IN THE ORIGINAL)

Owner Instructions Original Instructions Warning! Read instructions before using the machine. LoLine NLL 332 NLL 415

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

40 Built-in Electric Fireplace Operating and Installation Instructions

PIR Sensor. User s Guide

USER MANUAL. Intelligent toilet Primus

Homeowner s Installation Instructions & Operating Manual

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

IMPORTANT SAFETY INFORMATION:

888 TWO WAY CAR ALARM SYSTEM USER S MANUAL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

Driveway Alarm INSTALLATION MANUAL.

Ion Gateway Cellular Gateway and Wireless Sensors

MOTOR FOR SLIDING GATES SERIE GR8 220V

Little Anne. Important Product Information

Instructions for the fan motor control system, SILVER C

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

OPERATING MANUAL CUSTOMER SERVICE NO

VK902 Compact Combination Microwave Oven Installation, Use and Maintenance

Micro-Computer Induction Cooktop SR-1885SS

Pet Immune SAW PIR Motion Sensor

Blueair C User Manual

Thermometer model 02059

safety & regulatory information

Induction Cooker. User s Manual. Model: MC-STW1316

Owner s Manual. PIR-1 IR Learner

The New EMC Directive 2004/108/EC

Box60/ 70/ 90. Box60_70_90 v8

English. FCC declaration. Electro Magnetic Compatibility (EMC) Warning. This device complies with part 15 of the FCC rules.

Operating Instructions!

HEAT RECOVERY AIR HANDLING UNIT

Transcription:

Swing Door Operator EM EMSW User Manual Original instructions

CONTENTS - Original instructions Instructions for safe operation... Congratulations on your new automatic door!... Electronic equipment reception interference... Environmental requirements... Product liability... Service... Intended use... Technical specification... How the EM EMSW works... Regular safety checks... General accessories... Safety accessories... Troubleshooting... Service/Maintenance... Other products from Entrematic Nordic... Declaration of conformity... 3 4 4 4 4 5 5 5 7 10 10 10 11 11 All rights in and to this material are the sole property of Entrematic Nordic AB. Copying, scanning, alterations or modifications are expressly forbidden without the prior written consent of Entrematic Nordic AB. Rights reserved for changes without prior notice. Backtrack information: folder:workspace Main, version:a329, Date:201-0-23 time:02:41:58, state: Frozen 2 Issue 201-0-23

Instructions for safe operation Failure to observe the information in this manual may result in personal injury or damage to equipment. To reduce the risk of injury to persons - use this operator with single or double pedestrian swinging or folding doors only. Do not use the equipment if repair or adjustment is necessary. Disconnect supply when cleaning or other maintenance is to be carried out. The operator can be used by children age 8 and above, and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, if they have been given supervision or instruction by a person responsible for their safety concerning safe operator use and the possible hazards involved. This does not however prevent those persons to use the door where the operator is installed. Cleaning and user maintenance shall not be made by children without supervision. Do not let children climb on or play with the door or the fixed/remote controls. The doorset can be operated automatically by sensors or manually by activators. It can also be used manually as a door closer. Issue 201-0-23 3

Congratulations on your new automatic door! Entrematic Nordic has developed automatic doors for more than 50 years. State-of-the-art technology and carefully tested materials and components provide you with a superior product. As with all other technical products, your automatic door requires periodic maintenance and service. It is essential that you know your automatic door (system) and that you recognize the importance of maintaining it in compliance with applicable standards for safety. Your local Entrematic Nordic-authorized representative is familiar with these standards, as well as all applicable local codes and Entrematic Nordic recommendations for power-operated pedestrian doors. Service and adjustments performed by your Entrematic Nordic-authorized representative, will ensure safe and proper operation of your automatic door unit. Electronic equipment reception interference The equipment complies with the European EMC directive (US market FCC Part 15), provided installed according to Installation and Service manual. The equipment may generate and use radio frequency energy and if not installed and used properly, it may cause interference to radio, television reception or other radio frequency type systems. If other equipment does not fully comply with immunity requirements interference may occur. There is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Re-orient the receiving antenna. Relocate the receiver with respect to the equipment. Move the receiver away from the equipment. Plug the receiver into a different outlet so that equipment and receiver are on different branch circuits. Check that protective earth (PE) is connected. If necessary, the user should consult the dealer or an experienced electronics technician for additional suggestions. Environmental requirements Entrematic Nordic products are equipped with electronics and may also be equipped with batteries containing materials which are hazardous to the environment. Disconnect power before removing electronics and battery and make sure it is disposed of properly according to local regulations (how and where) as was done with the packaging material. Product liability According to regulations, the following are the responsibility of the owner or caretaker of the equipment that the equipment operates correctly, so that it gives sufficient protection in regard to safety and health that the equipment is operated and regularly maintained, inspected and serviced by someone with documented competence in the equipment and in applicable regulations that the provided Service Log Book and Site Acceptance Test and Risk Assessment documents are kept available for maintenance and service records that inspection covers the emergency opening function (when applicable) that the closing force is appropriate for the door size on fire-approved door systems (when applicable) 4 Issue 201-0-23

Service Regular inspections by a trained and qualified person, and the frequency of service occasions, should at minimum be made according to national regulations or industry standard, in the absence of a national regulation. This is especially important when the installation concerns a fire-approved door or a door with an emergency-opening function. To extend the life of your investment and ensure safe and reliable operation of the door, we recommend a minimum of 2 visits per year or more, depending on usage and operating conditions. Environmental aspects shall also be considered. Talk to your Entrematic Nordic representative to learn more about our service offering. Intended use The EM EMSW is an automatic swing door operator developed to facilitate entrances to buildings and within buildings. The EM EMSW is an electrohydraulic operator approved for fire door applications. It is to be installed indoors where it is suitable for almost all types of external and internal swing doors. This widely-used operator can be found on applications ranging from handicapped-access in private homes to high-traffic retail operations. The door is designed to offer continuous use, a high degree of safety and maximum lifetime. The system is self-adjusting to the effects caused by normal variations in the weather conditions and to minor friction changes caused by e.g. dust and dirt. For escape in emergency situations the doorset is opened manually. For installation and maintenance see Installation and Service manual 1004291. Save these instructions for future reference. Technical specification Manufacturer: Address: Type: Mains power supply: Power consumption: Degree of protection: Approvals: Entrematic Nordic AB Lodjursgatan 10, SE-21 44 Landskrona, Sweden EM EMSW 230 V AC +/-10%, 10 A, 50 Hz Max. 230 W (Max. 40 W Double door set) IP20 Third party approvals from established certification organizations valid for safety in use, see Declaration of Incorporation. Issue 201-0-23 5

How the EM EMSW works The EM EMSW uses a motor to open and a spring to close the door. The operator can also be set up to control an electric lock if such a device is installed. To activate the operator you can use a manual activator (elbow switch) or an automatic activator (radar device). It is also possible where local standards allow to activate the operator by just pushing the door, if there is such a push-and-go device installed. After the door has been activated it will open and stay open for a specified HOLD OPEN TIME (HOT). When the HOT has elapsed the door will close. The EM EMSW can be set in three different modes (if a programme selector is installed), see picture below. In fully manual use (or in case of a power failure) the EM EMSW acts as a normal door closer. Position AUTO Normal position OFF OPEN Function The door can be opened with the inner and outer manual and/or automatic activators. The electric strike, if fitted, is open. The door is closed. The door cannot be opened with inner and outer activation units. The door is locked if an electromechanical locking device has been fitted. The door can be opened with a key switch (if fitted). The door is held permanently open by the motor. Issue 201-0-23

Regular safety checks To help you fulfil the national/international requirements and to avoid malfunction and risk for injuries, we have provided the following checklist. Do not use if repair or adjustment is necessary. Disconnect supply 14 when cleaning or other maintenance is to be carried out. Daily Action Activate your operator and check visually, fastening and any damage of operator 1 arm system 2 cables 3 hinges 5 door and glass Also inspect your operator and check visually for sharp edges on the door leaf and door frame (if any) 7 condition of door seals 8 finger protection 9 and finally that the complete door runs properly and closes slowly in a smooth way Set the programme selector to OFF and check that the operator and electromechanical lock (if fitted) work together. Also check that the lock 10 really secures the door. If problem occurs Activate the manual activation units 11, if any, and walk towards the door. Check that the door has opened appropriately while you pass the entrance/exit. Then proceed with the automatic activation units in the same way. Check the safety sensors 13 if any. The door must not hit you when opening nor when closing. If you are unsure of which type of sensor you have, please contact your Entrematic Nordic representative. Escape doors Fire doors By law, these tests must be performed regularly by trained personnel. Set the programme selector in AUTO mode. Push the door manually in escape direction and make sure that no object or function will prevent the door from opening. Also make sure the escape route is free for use. Let the door close after an impulse ensuring nothing prevents the door from closing and locking (if regulations require it). = = Take appropriate measures. Contact your Entrematic Nordic representative. For contact information, see last page. Issue 201-0-23 7

FUNCTION AND VISUAL INSPECTION 14 3 13 8 2 4 3 3 4 3 1 11 5 10 9 7 CLEANING The best way to remove dust and dirt from the EM EMSW is to use water and a soft cloth or a sponge. A gentle detergent may be used. To maintain the quality of the enamel layer, the surfaces should be cleaned once/four months period. The cleaning should be documented. To avoid damages to the profiles the brushes/weather stripping must be vacuum-cleaned weekly. Do not expose windows, doors or profiles to alkalis. Both aluminium and glass are sensitive to alkalis. Do not clean with high pressure water. Operator, programme selector and sensor may be damaged and water may enter the profiles. Do not use polishing detergent. Do not scrub with materials like Scotch-brite, as this will cause mechanical damage. 8 Issue 201-0-23

TG XXXXXX XXXXXXX XXXXXXXXXXXXX XXXXXXXXXX ART. NO. DESIGNATION TYPE XXXXXX XXXX XXXXXXXXXXX PROJECT/SERIAL NO. YEAR+WEEK TEMPERATURE XXXXXXX XXXX XXX XX/XX XXXXX VAC A W Hz LOAD XXXXXXX 1 2 3 4 5 7 8 PROD. ORDER CLASSIFICATION DIN 1850 SÜD xxxxxxx xxxxxxx 1002 Click! SIGNAGE Ersätter lås med fallkolv till typgodkända slagdörrar enl. förteckning Skydd mot olyckor vid rörliga anordningar SITAC XXXX G A Entrematic Group AB LODJURSGATAN 10 LANDSKRONA SWEDEN FACTORY NO. X 1004197 No entry H D B Click! E No entry F C 1000 mm 800 mm Action Check that all required signage is applied and intact. Mandatory indicates that the signage is required by European directives and equivalent national legislation outside the European Union. A Product label: Mandatory If problem occurs B C D E F G H Emergency break-out: Mandatory, if approved for escape route. Entrematic Nordic door sticker: Mandatory, if applicable to highlight the presence of the glass (applied to all glass sections that are moving). Supervision of child: Mandatory, if applicable (applied to both sides of the door). To be placed on entrances where the risk analysis shows use by children, elderly and disabled. Operator designed for disabled people: Recommended, if applicable (applied to both sides of the door). Activation by disabled people: Recommended, if applicable. SITAC label: Mandatory in SE No entry, identifying one-way traffic: Mandatory in GB and US, if applicable, not included in the product. = Contact your Entrematic Nordic service representative. For contact information, see last page. Issue 201-0-23 9

General accessories Your EM EMSW can be further improved with the following add-ons (please contact your local Entrematic Nordic dealer for detailed description). Position switch 4, see page 8 Electrical lock10, see page 8 Key switch 11, see page 8 Elbow switch 11, see page 8 Radar, see page 8 Wireless transmitters (not illustrated) Access control (not illustrated) Door stop (not illustrated) Safety accessories Even though the EM EMSW is installed to comply with all applicable safety regulations, it is possible to enhance safety/comfort with the following add-ons (please contact your local Entrematic Nordic company for detailed description). Safety sensors13, see page 8. Finger protection 9, see page 8. Troubleshooting What s wrong? The door does not open The motor does not start The motor starts but door(s) will not open The door does not close The door opens and closes continuously Remedies Change the setting of the program selector. (See page ). Check that there are no objects in the detection zone if a sensor is fitted. Check the mains switch and fuse in the building. Unlock the mechanical locks. Check that nothing is jammed beneath the door. Change the setting of the program selector. (See page ). Check that there are no objects in the detection zone if a sensor is fitted. Check that nothing is jammed beneath the door. Check that there are no moving objects within 1-1.5 m (39"-59") from the door if an automatic activation unit is fitted. If the problem continues, please contact your Entrematic Nordic representative. 10 Issue 201-0-23

Service/Maintenance Service and adjustments performed by your Entrematic Nordic-authorized representative will ensure safe and proper operation of your automatic door unit. Remember to keep Service Log Book and Site Acceptance Test and Risk Assessment documents available. These are used together. The table below shows the recommended interval in months, when to replace parts during preventive maintenance. Cycles/hour in operation Part Part number <10 Low traffic <100 Medium traffic >100 High traffic Abusive Environment Vibration absorbers and oil plug PUSH/PUSH-335 service kit PULL/PULL-220 service kit ST-V/H service kit Limit switch Capacitor CSDB-230 control unit CSDA-S CSDA-F 331003882 330000485BK/SI 33000048BK/SI 331003887 335514 3355599 331004115 00089 00081 24 24 24 24 24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Other products from Entrematic Nordic Door Systems Sliding doors Automatic and manual activation units Issue 201-0-23 11

We Entrematic Group AB Lodjursgatan 10 SE-21 44 Landskrona Sweden declare under our sole responsibility that the type of equipment: EM EMSW complies with the following directives: 2014/30/EU ElectroMagnetic Compatibility Directive (EMCD) 200/42/EC Machinery Directive (MD) Harmonized European standards which have been applied: EN ISO 13849-1:2008 EN 0335-1:2002+A1:2004+A11:2004+A2:200+A:200+A13:2008+A14:2010+A15:2011 EN 0335-2-103: 2003 + A11:2009 EN 1000--2:2005 EN 1000--3:2007 EN 1005:20 EN 0950-1:200+A11:2009 Other standards or technical specifications, which have been applied: BBR Declaration of conformity FCC 47 CFR Part 15 B IEC 0335-2-103 ed.2 200+A1:2010 DIN 1823-4:1997-05 EN 1158:1997+A1:2002+AC:200 IEC 0950-1:2005 ed. 2 BVL UL 325 IEC 0335-1 ed. 4:2001+A1:2004+A2:200+C1:200 DIN 1850-1/-2:2010 EN 134-1:2008 EC type examination or certificate issued by a notified or competent body (for full address, please contact Entrematic Group AB) concerning the equipment: DIBT Z-.5-170 013/05 TÜV B 03 7499 00 The manufacturing process ensures the compliance of the equipment with the technical file. The manufacturing process is regularly assessed by 3rd party. Compilation of technical file: Christian Trobro Entrematic Group AB Lodjursgatan 10 SE-21 44 Landskrona Sweden Email: christian.trobro@entrematic.com Place Landskrona Date 201-04-20 Signature Christian Trobro Position Product Safety & Liability Manager DoC 100793-EMEI-10.0 Issue 201-0-23

Entrematic Nordic AB, Lodjursgatan 10, SE-21 44 Landskrona, Sweden Tel: +4 10 47 48 300 www.entrematic.com info.em@entrematic.com