Green Comfort, Design and Energy Saving. FCL and FCLI Inverter MORE VALUE TO YOUR ELL-BEING Cassette fan coils
Cassette fan coils FCL On-Off / FCLI greater comfort, less consumption The future is Inverter Cassette fan coils with DC brushless motor FCLI is the Aermec range of Cassette-type fan coils with continuous 0-00% air flow rate variation and continuous heating/cooling capacity variation. The nominal cooling capacity ranges from.9 k to.0 k. The nominal heating capacity ranges from 2.4 k to 3.0 k. 50% saving on electricity bills in relation to traditional ON-OFF Cassette fan coils; total comfort: reduced temperature swings and relative humidity variations; quickly obtained temperatures in the air-conditioned rooms; very quiet operation. -50% is the annual saving of electricity compared to traditional On-Off FAN COILS. Traditional On-Off Cassette fan coils FCLI -50% is the reduction of CO2, carbon dioxide emissions responsible for the greenhouse effect.
Air-conditioned rooms with traditional On-Off Cassette fan-coils 90 att Air-conditioned rooms with new FCLI INVERTER Cassette fan coils 45 att is the total average ventilation power input* is the total average ventilation power input* * Values given as an example referring to the whole apartment * Values given as an example referring to the whole apartment 3 speed on-off fan coil -9 is the noise level reduction, especially favourable during night-time operations. FCLI Thanks to Inverter technology combined with the latest generation and highly efficient DC Brushless electric motor, the FCLI series Cassette fan coils are able to modulate the airflow rate (and therefore the heating and cooling capacity) in a continuous manner 0 % - 00%. This means the capacity is adjusted moment by moment to the specific needs of the air-conditioned room. The result? 50% energy savings during winter and summer air-conditioning ventilation, compared with the traditional On-Off ranges. That is to say that for every 00 of power consumption of a traditional on-off fan coil, FCLI with Inverter makes a net saving of 50.
Coil Electronic box valve The triple loop heat exchange coil has allowed to increase the energy efficiency of heat exchange by 40% compared to traditional Cassette with circular coils. The electronic box with bayonet fitting makes installation and maintenance operations extremely easy. The three-way valve is fitted as standard inside the machine. The two-way modulating valve is also available on request, suitable for innovative systems with variable water flow rate. other Aermec range fan coils with inverter FCXI-A FCXI-U ventilcassaforma FCXI-P FCXI-U Sound power [] Traditional ON-OFF fan coil FCLI Inverter Heat load tempo (h) 0 24 FCLI Inverter continuously modulates the air flow rate. The result being an averagely reduced noise emission of 50% in relation to a traditional on-off Cassette fan coil. The chart shows the development of the sound power - expressed in - as the ambient heat load varies. You can see that the FCLI Inverter Cassette fan coil produces lower sound emissions compared with traditional on-off Cassette fan coils, thanks to the continuous adjustment of the air flow rate to the immediate load. Research and innovation are essential prerequisite in order to maintain the leadership in the global market and Aermec, which holds this position, has always distinguished itself for the cuttingedge solutions of its products. The innovative capacity and constant attention to research to meet market needs and trends, as well as anticipating the demands, are developed through highly skilled staff but also through the cooperation with prestigious universities and teachers of subjects related to air-conditioning. The devices of the future are developed and designed within the modern Aermec laboratories, equipped with sophisticated and constantly updated equipment, such as the new semi-anechoic chamber of the Research and Development Department.
-50% is the annual saving of electricity of the FCLI inverter Cassette compared to traditional On-Off Cassette. -9 is the noise level reduction, especially favourable during night-time operations. reduction, especially favourable during night-time operations. -50% is the reduction of CO2, carbon dioxide emissions responsible for the greenhouse effect. BRUSHLESS MOTOR The DC brushless electric motor is the result of combining the most sophisticated technologies from the fields of mechanics and electronics. Brushless literally means without brushes. In fact, this is a direct current motor without contacts between the rotor and stator. ith the special inverter device, it is possible to control the speed and torque of the rotor continuously, just by means of the stator currents. Compared with the traditional alternate current motors, the brushless motor offers huge advantages: - The possibility to regulate the rotation speed in a precise, continuous manner (0-00%) - higher energy yields - longer life and greater reliability These characteristics have made the brushless motor irreplaceable in a wide variety of applications, amongst which: - robotics - automotive - precision drives - CD/DVD players - medical equipment EFFICIENCY AND SAVING The highly efficient electric motors of the latest brushless DC type, combined with the inverter technology of the FCLI fan coils, can modulate the air flow rate continuously (0%-00%) and therefore reduce absorption by up to 50% compared with traditional ON-OFF motors. This means that every 00 euro of power consumption of a traditional fan coil, the FCLI with Inverter produces a net saving of 50 e! HEAT EXCHANGE EFFICIENCY A significant element of the new FCL / FCLI series is the heat exchanger coil, the triple loop profile of which helps to increase the usable area of exchange compared to the circular coil, commonly used in traditional Cassette. The result is a 40% increase in heat exchange energy efficiency compared to traditional Cassette. INVERTER The FCLI fan coil continuously modifies the air flow rate, adapting it - moment by moment - to the real needs in the room. This produces considerable advantages in terms of electric savings, co mfort and noise reduction compared with a traditional on-off Cassette fan coil. QUIETNESS The new fan unit with polycentric Absorbed electric capacity [att] 60 50 Traditional ON-OFF Cassette Fan Coil FCLI Inverter 40 30 20 0 - Air flow rate (m3/h) 0 00 200 300 400 500 600 700 The highly efficient electric motors of the latest brushless DC type, combined with the inverter technology of the FCLI fan coils, can modulate the air flow rate continuously (0%-00%) and therefore reduce absorption by up to 50% compared with traditional 3-speed motors.
+40% Is the increase in the heat exchange efficiency obtained with the new double loop coils. -30% is the reduction in the COOLING TIME OF THE AIR-CONDITIONED ROOM. -75% is the reduction of the STARTING CURRENT in the FCLI inverter Cassette in relation to the traditional On-Off Cassette. blades and the in-depth study of air flows inside the machine have led to a significant reduction of the fan coil s noise power (up to 9 db (A) less than the FCA series). (see graph). The silence of the FCLI with inverter models is ensured by continuous variation of the air flow rate that allows the fan coil to operate at lower speeds. The silence of the FCL on-off models is ensured by the presence the so called super minimum fourth speed. VERSATILITY The great versatility of installation is achieved thanks to a wide range of accessories, including: suction and discharge grille with manually adjustable fins that can be connected to a wire control or with fins manoeuvred by remote control; flange for delivery to adjacent room or flange and bulkhead for emission of external air into the environment; electrical heating resistor for connection to the grille; motor-driven three-way on-off valve for the heating element in 4-pipe systems. motor-driven two-way on-off valve for the heating element in 4-pipe systems. Other accessories also include, interface cards to operate more Cassette with the same control panel. The FCL fan coil may also be introduced in the latest variable water flow systems, thanks to the inclusion of the two-way valve. The twoway valve is also available for the extra coil in case of 4-pipe systems. EASY INSTALLATION AND MAINTENANCE The easy installation and maintenance is given by the overall accessibility of the hydraulic, aeraulic, electrical and electronic parts from the bottom of the machine (an inspection hatch is not needed in the ceiling next to the machine). In this regard, the electronic box with bayonet fitting makes the intervention on these components much easier. COMFORT The FCL On-Off and FCLI inverters fan coils, the first thanks to the 4-speed motor and the second due to the continuous modulation of the power output, ensure that the temperature and relative humidity of the air within the air-conditioned rooms is relatively constant. The minimisation of oscillation is a guarantee of absolute comfort. 00 80 Sound power [db (A)] Air flow rate = 350 mc/h Pfrig=8,7k Pfrig=9k 60 63 54 40 20 0 Note that, for the same air flow, the new FCL / FCLI Cassette fan coils are much quieter and produce greater cooling capacity than the older FCA models. This result was achieved by optimising the aeraulic flows and thanks to the triple loop heating coil, with greater exchange surface than the older circular coils.
Technical data Mod. FCL 2-pipe versions Maximum heating capacity 50 C (E) ater flow rate 50 C Pressure drops (VL) 50 C (E) Total cooling capacity (E) Sensible cooling capacity (E) ater flow rate Pressure drops (VL) (E) l/h kpa l/h kpa speed 4 speed 3 Air flow rate (E) speed 2 speed (min) Fans Sound power (E) speed 4 speed 3 Sound pressure speed 2 speed (min) Heat exchanger water content ater connections Kvs (standard version 3R valve) Input power (E) (max) Input current (max) Starting current no. l Ø Gas A A 36 42 62 82 02 22 2380 3750 7 56 9 4 900 3000 520 2400 7 56 0 5 - - 600 600 40 40 300 300 46 46 - - 37 37 29 29 26 26,2,5 2,5 2,5 45 45 0,22 0,22 0,66 0,66 4950 679 23 3950 360 679 25 700 530 360 260 53 44 37 29 26,5 2,5 75 0,33 0,99 6250 857 4980 380 857 36 880 660 500 380 6 52 45 38 2, 2,5 83 0,37, 700 0 23 6000 4200 0 25 00 830 680 460 50 4 36 34 30 3 4 50 0.70 2.0 0600 548 25 9000 6660 548 28 350 00 830 560 54 45 39 36 3 4.5 4 55 0.69 2.07 3000 892 34 000 8470 892 38 750 350 00 750 60 5 45 4 35 4.5 4 75 0.75 2.25 Mod. FCLI 2-pipe versions 42 62 Maximum heating capacity 50 C (E) Pressure drops (VL) 50 C (E) Total cooling capacity (E) Sensible cooling capacity (E) ater flow rate Pressure drops (VL) (E) Air flow rate (E) speed (min) Fans Sound power (E) speed (min) Sound pressure speed (min) Heat exchanger water content ater connections Kvs (standard version 3R valve) Input power (E) (max) Input current (max) kpa l/h kpa no. l Ø Gas A 2380 9 900 520 7 0 600 50 46 3 37 22.2 2.5 33 0.28 4950 23 3950 360 679 25 700 50 53 42 23.5 2.5 55 0.43 6250 4980 385 857 36 880 50 6 33 52 24 3 2.5 6 0.47 Power supply = 230V~ 50Hz (E) = EUROVENT certificate performances Performance values refer to the following conditions: Sound pressure measured in semi-reverberating chamber, The performances are the same for all the configurations: FCL (standard), FCL V2 and FCL VL. 00 m 3, and with reverberation time Tr = 0.5s. COOLING: - Room air temperature 27 C D.B., 9 C.B; - Inlet water temperature 7 C; maximum speed; t water 5 C. HEATING: - Room air temperature 20 C ; - Inlet water temperature: 50 C; maximum speed; - ater flow rate as for cooling.
PAGLIARDINIASSOCIATI FCL On Off and FCLI INVERTER: THE CUTTING-EDGE TECHNOLOGY THAT CONFIRMS LEADERSHIP Fan coils and Aermec: a duo where company, brand and product identify each other. Aermec is synonymous with leader in the air conditioning sector: a leading company both in Italy and Europe, who have achieved supremacy resulting from years of experience, cutting-edge technological solutions, use of materials and components of superior quality, refined design and high performance combined with very low noise levels. ith FCLI, the brushless motor technology is making the Aermec Cassette fan coils a technological breakthrough in terms of efficiency and energy savings. A technological breakthrough that represents the confirmation of undisputed leadership. Aermec S.p.A. Via Roma, 996-37040 Bevilacqua (Verona) Tel. +39 0442 633 Fax +39 0442 93577 www.aermec.com - info@aermec.com DFCLUY.0