Pre-Installation Requirements:

Similar documents
Installation & Operations Manual


TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

Alarm Tone Generator Model AG17

Interrogator 200 Audio Verification Module (AVM)

Computer Room Guard Model VM Manual and Installation Instructions

Public Safety DAS Annunciator Panel

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

N-8000 SERIES IP INTERCOM SYSTEM

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

TrueAlert Addressable Notification

Memcom Emergency Telephone

Staff Alert Panel. Installation Guide. Using the Touchpad Exit Controller B

MST-1. Varifan USER S MANUAL MST-1 ADJUST. 9 per day HI F2. DIFF on off TIMER. reduc.

Basic Installation Manual

D1255RB/D1256RB/D1257RB

Addressable NAC Output Module D327A

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Security System. User Guide for the LED Command Center

July 14, 1999 DF C-100.

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

DESCRIPTION INSTALLATION

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

Setup & Operation Index

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

Memcom + Emergency Telephone

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

Rev C May GE Interlogix. Part No: R. CareGard. User Guide

SECTION FIRE ALARM SYSTEMS

WHO IS RATH COMMUNICATIONS?

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

INSTALLATION INSTRUCTIONS

Supervised Security System Owner's Guide

June 10, 2002 DF C S2424

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

ANNUNCIATOR FIXED MODULE

Installation Instructions

DYGIZONE GJD910 Lighting Controller & Enunciator

Refrigerator/Freezer Guard Models VM605, VM605E. Property Guard Models VM610, VM610E. Temperature Monitor and Alarm

EVO192 v3.0 Fire and Burglary What s New

4286/4500 Voice Module Set up and Troubleshooting

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

ERS-3600B. PERS-3600B Personal Emergency Reporting System

MEDICAL ALERT SETUP GUIDE

AT60 AUTO DIALLER User Guide

FreezeAlarm Dialer Pro

FreezeAlarm Dialer FA-700 Installation and Operations Manual

Property of Monitronics Inc

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

INSTRUCTIONS CONTROL PRODUCTS INITIAL SET-UP. Innovative Technologies in Custom Electronic Design & Manufacturing

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Installation Instructions for W2H Series Signals

User instructions EasyAlarm CONTROL

Analog Room Pressure Monitor RPC Series

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

ACCURATE ELECTRONICS INC

Security System. User s Guide for the Text Command Center

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

VIDEO INTERCOM SYSTEM 2000F

Remote NAC Power Supply D7038

2 Wire Nuts (or other approved wire connectors) (Field-supplied) Push Button(s) Phillips Head Screwdriver (Field-supplied) Control-R Module

TFD-1 Installation & User s Guide

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

FTP-1000 Touchpad/Display Installation Manual

HomeSitter HS-700 Installation and Operations Manual Emerson Control Products Inc Lake Drive West Chanhassen, MN Document No.

Installation and Operation Manual. Model Q916

MiniAlarm Plus. Model MA-5000

SP-1000X. Panic Device Power Controller Installation Guide. Rev

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide

Deluxe FreezeAlarm. Model FA-D2

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Voice Dialer Temperature & Power Loss Monitor VD-5100-TM / VD-5101-TM

Tek-ENTRY Apartment Entry Systems

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

Product Manual SZ1009

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

1. Introduction. 2. Product overview

Auto Dialer. Manual E-921APQ E-921GPQ

AVCOM System Installation Instructions

Series. Access Power Controllers. Installation Guide

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

Part. Test System Weekly See Watch ~Test. Points

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

SIGA-CC1 Single Input Signal Module Installation Sheet

GSM RFID VOICE Alarm System

Transcription:

AlphaRefuge 2100 Series (V3) Area of Refuge and Rescue Assistance system Installation, Use and Wiring Instructions Pre-Installation Requirements: 120V Power Determine Communication: 1. Dedicated analog phone line from POTS, PBX, or Central Office. 2. VoIP - requires use of Alpha Model ABL-VOIP to connect Master to VoIP phone system. 3. Internal Intercom (no offsite calling) - requires Alpha Model 2100-LINESIM. Twisted, shielded 22 or 24 AWG wire cabling to connect each Refuge Call Box (RCB) to the Refuge Command Center (RCC) Use 24V 18/2 wire for powering the Emergency Phones from the 24VDC Power Supply. NOTE: Terminals and markings shown in this manual may not be in the order in which they appear on the actual equipment. When installing, observe all national and local electrical and building codes. Copyright 2011-2018, Alpha Communications, All Rights Reserved. AWD265 Rev. 1 (02/2018)

Installation Steps: Step 1 Remove the front cover from the SmartRescue and mount the SmartRescue back box to the wall using suitable mounting screws (not included). Step 2 Punch out the conduit knockouts for the analog phone line and phone cabling runs. Step 3 Connect an analog phone line to the outside phone line (Diagram A) Step 4 Connect the backup battery cable to the battery terminal (battery included). (Diagram A) DIAGRAM A 2

Step 5 Wire your Refuge Command Center to a 120VAC Power Source (If your Refuge Command Center comes with a plug-in transformer, simply plug it in, and connect to 24VDC on RCC board). Connect the hot wire of the 120vac to the L screw Connect the neutral wire of the 120vac to the N screw Connect the ground wire of the 120vac to the ground screw Connect one lead of the DC power connection to the V screw and the other to the +V screw, polarity is not important. Connect the DC power connection to the SmartRescue. The power connection is on the lower left hand side of the board. 3

Wiring Refuge Call Boxes to Refuge Command Center Step 6 Wire the Refuge Call Boxes to the Reguge Command Center Refuge Call Box *Use 22 or 24 AWG 2-pair twisted, shielded cable between the phones and the SmartRescue. The maximum communication run is 5,100 Connecting wire run: To Refuge Command Center: Insert 4 wires for each phone as shown below. To Refuge Call Box: Wire out to a standard 2-pair RJ11 phone jack. Connect this jack to the 5 cord supplied by Alpha. Refuge Command Center The Refuge Call Boxes come with a 5 cord with an RJ11 on both ends. If you received a spade connector, your company requested it. Wire according to your company guidelines. *Shields from the cabling runs (if used) should be attached to one of the mounting screws on the SmartRescue housing. 4

Step 7 Mount the front cover back onto the enclosure. Programming the Refuge Command Center Step 8 Programming Options for Refuge Command Center Option 1 (Factory Default) The Emergency Phones will call directly offsite and not stop at the Refuge Command Center. That phone s button will light at the Refuge Command Center during the call. (Keep in Default Mode if site is not manned 24/7 to answer calls onsite) Option 2 Program the Refuge Command Center to Allow the Emergency Phones to call it first, then outside number(s): (Used when staff are available at certain times to answer calls) 1. Hold down Red Disconnect and Submaster 1 buttons for 5 seconds 2. Release buttons (you will hear a confirmation tone) 3. Press Phone 2 button, then Red button, and then the Phone 1 button 4. Press Submaster 2 button, then Submaster 1 button (you will hear a confirmation tone) *Note: If you need to restore the Refuge Command Center to Default Mode see page 11. 5

Powering The Refuge Call Boxes Step 9 Provide power to the Refuge Call Boxes through one of the following 3 options: Option 1: Powering up to ten Refuge Call Boxes via PWR2410A Power Supply Use 1-pair 18 AWG wire for power, maximum distance of 5,100 Do NOT wire more than 3 devices per wire run and a maximum of 11 devices per Power Supply Option 1: Transformers (Only applies if your phone comes with one supplied by Alpha) Option 2: Powered Directly by Elevator Car 6

Programming The Refuge Call Boxes Step 10a Program appropriate options for each of your Refuge Call Boxes Option 1: Bypass Refuge Command Center and Dial Directly to Offsite Number(s) Press Enter to get into program mode Press 1, Enter, (Emergency Number), Stop If using two emergency numbers: Press 2, Enter, (Emergency Number), Stop Repeat for up to 5 total emergency numbers To exit programming mode: Press and hold Stop for 2-3 seconds until warble sound Option 2: Call Refuge Command Center and if No Answer, Dial Offsite Number(s) Press Enter to get into program mode Press 1, Enter, (Emergency Number), Stop Press 2, Enter, (same Emergency Number as entered in b.), Stop To exit programming mode: Press and hold Stop for 2-3 seconds until warble sound Step 10b Program the Location Message NOTE: This Should ALWAYS be done, unless your call center requests otherwise!!! Press Enter to get into program mode To turn on message, press 1, 3, Enter, 2 For no message, press 1, 3, Enter, 0 Press 6, Record, (wait for beep, speak your message), Stop To program frequency of message, press 1, 3, Enter, 1 = plays message once 2 = plays message twice (this is standard configuration) 3 = plays message until the called party presses * on their phone To exit program mode, press and hold Stop for 2-3 seconds until warble sound 7

System Operation & Testing A. Once finished, the following Refuge Command Center LEDs should be lit: Power LED, located on bottom edge of the faceplate, will be constant lit green Battery LED, also located on bottom edge of the faceplate, will be constant lit. Red = Low level charge Yellow = Mid level charge Green = Full Charge B. Initiate a Call to an Emergency Phone or Sub-Master from the Refuge Command Center: Lift handset on Refuge Command Center Press the Talk button for the corresponding Refuge Call Box or Sub-Master you wish to call into The green LED will light next to that button You should have two-way communication to that device You can place the device on hold by pressing the Talk button a second time To resume communication, press the Talk button a third time To disconnect, hang up the Refuge Command Center handset C. Emergency Phone places a call into the Base Station: You will hear an alternating audible tone at the Refuge Command Center indicating a call has been initiated by one of the phones The corresponding green LED will light on the Refuge Command Center next to the phone that placed the call Lift the handset and there is two-way communication between the Refuge Command Center and the Refuge Call Box. The handset can be hung up on the Refuge Command Center at any time to end the call D. Refuge Call Box places a call to the Refuge Command Center then an Outside Number, or Just to an Outside Number: You will hear an alternating audible tone at the Refuge Command Center indicating a call has been initiated by one of the Refuge Call Boxes (if programmed to call outside line only, no tone) The corresponding green LED will light on the Refuge Command Center next to the Refuge Call Box that placed the call If call is not answered at the Refuge Command Center, the Refuge Call Box will hang up and dial the second number programmed into the phone The CO Line LED, located next to the red button, will also be lit indicating that the outside line is active. Two-way communication can then take place between the outside line and the Refuge Call Box once the call is answered The Refuge Command Center can join the conversation by lifting the handset To talk to rescue services only from the Refuge Command Center, place the Refuge Call Box on hold by pressing the corresponding Talk button. To bring them back into the conversation, press the Talk button again. To disconnect rescue services, press the red button at the top of the Refuge Command Center faceplate. The Rescue Services LED will go off and leave you communicating with the Refuge Call Box only. Handset on the Refuge Command Center can be hung up at any time to end the call. If above testing works and voice communication is clear, congratulations, you have successfully installed the system! 8

Appendix System Supervision NFPA-Required for Area of Refuge Systems, not Required for Elevator Industry NFPA-2016 24.10.4 - All pathways between a remote area of refuge station and the central control point shall be monitored for integrity. 24.13.4 Power Supplies: All control units shall meet the power supply requirements of section 10.6s 10.6.9 Monitoring Integrity of Power Supplies 10.6.9.1 Unless otherwise permitted or required by 10.6.9.1.3 and 10.6.9.1.6 all primary and secondary power supplies shall be monitored for the presence of voltage at the point of connection to the system. 10.6.9.1.1 Failure of either the primary or secondary power supply shall result in a trouble signal in accordance with section 10.14 10.6.7.2.1 The secondary power supply (battery back up) shall have sufficient capacity to operate the system under quiescent load (system operating in a nonalarm condition) for a minimum of 24 hours and, at the end of that period, shall be capable of operating all alarm notification appliances used for evacuation or to direct aid to the location of an emergency for 5 minutes. 9

Appendix Phone Line Supervision Alpha Refuge Call Boxes have a built-in Line Check Feature. The station constantly looks for a phone line. When a phone line is not detected it will trigger the onboard relay. Connect the relay to an alarm device for notification. Adjusting Volume on Refuge Call Boxes Locate the silver VR1 port on the bottom right corner of the Refuge Call Box board Using a fine Philips Head screwdriver, turn the VR1 clockwise to increase the volume and counterclockwise to decrease the volume. 10

Appendix Refuge Call Box System Activation Relay When an Emergency phone has been activated, this relay changes state and can be connected to an alarm panel, strobe, or other notification means. Restoring Refuge Command Center Factory Default Settings Hold down Red Disconnect and Submaster 1 buttons for 5 seconds Release buttons (you will hear a confirmation tone) Press Phone 2 button, then Red button, then Submaster 2 button, and then the Phone 5 button Press Submaster 2 button, then Submaster 1 button (you will hear a confirmation tone) 11

Appendix Troubleshooting PROBLEM Power LED is not illuminated: Battery LED is not illuminated or always shows red: LEDs on SmartPhone flash when button is pressed: Submaster and Phone LEDs blinking on Refuge Command Center: Refuge Command Center LEDs stay on: Two-way communication from Refuge Call Box is poor: Refuge Command Center will not dial phones: Refuge Command Center will dial Refuge Call Boxes, but Call Boxes will not dial Command Center: No sound or tone on SmartRescue handset: Dial tone present on SmartRescue handset and phone is not calling out: POSSIBLE CAUSE & SOLUTION Check to make sure the transformer is connected to a good 120V power source. If 24V powered, check the power supply. Make sure power connection on the circuit board is secure. Battery has not charged for long enough. Wait 18 hours for the battery to trickle charge. When fully charged it will have 19v. Battery plug is not connected to circuit board. Verify connection. Battery is worn. It is recommended to replace every 2 years. Verify the phone line is working and is connected properly. Verify dial tone is present at the Refuge Command Center. Verify power is applied and the backup battery is connected properly to the Refuge Command Center board. Wires may be crossed. Verify wiring from the Refuge Command Center to the Refuge Call Boxes is correct. There is likely feedback on the line. Adjust the VR1 and VR2. Verify wiring is not spliced onto the phone line cord. Verify wires are connected properly from the Refuge Command Center to the Refuge Call Box(es). No outside phone line connected to Refuge Command Center. Phone line connected does not have working 24v to 52v. Line connected has voltage but does not have working dial tone. Plug analog phone into phone line and place a call out to verify line. Verify 24v power is connected to the SmartRescue base. There should not be a dial tone on the SmartRescue handset. Wire pairs are out of order. Verify wire pairs are connected to the correct pins. Wires are shorted and need to be replaced. ALPHA COMMUNICATIONS 42 Central Drive Farmingdale NY 11735-1202 TOLL-FREE TECHNICAL LINE 1-800-666-4800 Phone: 631-777-5500 Fax: 631-777-5599 WEBSITE: www.alphacommunications.com EMAIL: info@alphacommunications.com 12

13

14

15

16

RCB2100SF Flush Mount St. Steel Remote Call Box Station 17

RCB2100SF Flush Mount St. Steel Remote Call Box Station 18