HAWK SULTAN SERIES Sma rt Universa l Level Tra nsmitter And Network. Equipment types:

Similar documents
HAWK GLADIATOR SERIES. Equipment types:

Centurion Guided Radar HAWK CGR SERIES

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

OPTIBAR DP 7060 Supplementary Instructions

VERSAFLOW VORTEX Supplementary instructions

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Rosemount 4500 Hygienic Pressure Transmitter. Start

Installationsmanual GWSL1100/2100, GWML3100

INSTRUCTION MANUAL (ATEX)

OPTIWAVE X500 Supplementary Instructions

OPTISENS TUR 2000 Technical Datasheet

Radar Transmitters SITRANS LR400 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

Analog Room Pressure Monitor RPC Series

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

Installation Guide SmartRadar FlexLine

Rosemount 3490 Series

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

4) Intrinsic Safety Certification

Skymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Snifter ATEX22 VERSION. User Manual. Distributor

Level Measurement Continuous level measurement Ultrasonic transmitters

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

Approvals, Certificates and Conditions

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Software Version 2.01 LEVEL MONITOR MODEL 220

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Supplementary Installation and Operating Instructions. Category II2G

Network Speed Dome Installation Manual

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Survey of electrical equipment installed in hazardous areas on tankers

CEILING SPEAKER SYSTEMS F-2352CU2

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Model 144H. Product Data Sheet , Rev DB February Content

Quick Start Guide For the

RFM Series RFM-ISR Barrier. Installation Manual

NS-C8800 Natural Sound Center Speaker System NS-E8800 Natural Sound Effect Speaker System

Installing a Fan Tray in an Ethernet Routing Switch 8000 Series Chassis

Level Measurement Continuous level measurement - Ultrasonic transmitters

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Bedienungsanleitung. Fass-, Behälter- und Containerpumpen. F dichtungslos. F ,98% Fassentleerung. F

CEILING SPEAKER SYSTEM

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

Manual Power relay SR853

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Linkam Scientific Instruments USER GUIDE PE120-AFM. Temperature Controlled Peltier Stage

OPTIBAR P 1010/2010 C Supplementary instructions

MAN0604_Issue 09_ Apex

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

Model 144H. Product Data Sheet , Rev DB February Content

READ AND SAVE THESE INSTRUCTIONS

Model S4000TH. Intelligent Sensor for Hydrogen Sulfide Gas Detection

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

RT FLOW RATE TOTALISER

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Hazardous Area Zirconia Oxygen Systems

Installation guide 864 MTT Multi Thermo sensor Thermometer

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

805QS Pressure Switch-Transmitter

Installation and Maintenance Manual IM 1038

Earth-Rite II PLUS Static Earthing System

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

CEILING FAN OWNER'S MANUAL

CEILING FAN OWNER S MANUAL

Hygro/hygrothermal transducers (hygrometric)

2 000W CYCLONIC BAGLESS VACUUM

INSTALLATION HANDBOOK:

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

CEILING SPEAKER SYSTEM F-122C INSTRUCTION MANUAL TABLE OF CONTENTS 7. REPAINTING THE SPEAKER SAFETY PRECAUTIONS... 2

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Room Sensor for BACnet VAV Actuator

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

Ceiling Fan Ow n e r s Manual

PRECAUTIONS WHEN POSITIONING

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Intelligent Speed Dome Installation Manual. Version 1.0.0

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

INSTRUCTION MANUAL (ATEX / IECEx)

Sensor Interface Module Installation/Operation Instructions

SITRANS F. Ultrasonic Flowmeters FST030 (HART) Operating Instructions. Answers for industry. 07/2017. Edition

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

THE GOOD GUIDE TO BUTT FUSION JOINTING....Connect

Operating Manual Distribution box

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

F SERIES SPEAKER SYSTEM

Installation Guide

Carbon Monoxide Transmitter

OPERATION AND MONTAGE MANUAL ROOF FANS

READ AND SAVE THESE INSTRUCTIONS

Transcription:

Safety instructions 0359 HAWK SULTAN SERIES Sma rt Universa l Level Tra nsmitter And Network ATEX Category 1 GD (A0) Equipment types: AWRT series Sultan Remote Transducer AWR series Sultan Remote Electronics AWI series Sultan Integral Transmitter 1. General This document provides instructions for the installation of ATEX Certified Intrinsically Safe equipment for Category 1 hazardous gas and dust locations, according to EC-Type Examination Certificate ITS04ATEX22807X. ATEX Categories are relevant in all parts of the European Community. Device Category 1 is similar to Zone 0. This equipment can also be installed in lower Categories 2 and 3. The Hawk Sultan Series Acoustic Wave equipment uses high frequency acoustic waves to measure the distance from the sensor face to the material product surface. The equipment is available as an Integral Transmitter or as a Remote system, with various levels of Ex rating. The Remote Sultan system is one where an AWRT series Sultan Acoustic Wave Remote Transducer is mounted at the level measurement point, and an AWR series Sultan Remote Electronics unit is installed some distance away, in a more convenient location. The AWI series Sultan Acoustic Wave Integral Transmitter models consist of a transducer and an electronic control amplifier in a single housing. They are mounted directly at the level measurement point usually at the top of a vessel and focused downwards to the product surface. The Integral Transmitter includes a user interface keypad and display. 2. Equipment Identification The ATEX Category 1GD marking label is shown above. If Hawk Sultan Acoustic Wave equipment is installed and mounted in Category 1 or 2 hazardous areas, these User Manual Safety and Operating Instructions, the general Ex installation regulations 02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 1 of 13 Hawk Measurement Systems Pty Ltd

and the general installation regulations for electrical equipment must all be observed. The installation of Ex instruments should only be made by trained personnel. 3. Putting Into Service To put a Hawk Sultan Unit safely into service, the following steps must be taken: a) To be compliant, the equipment must be installed with Intrinsic Barrier devices as described in Section 10, Intrinsic Safe Installation. Cables from both hazardous and safe areas must be segregated from each other according to the appropriate Intrinsic Safe installation standards. b) Follow the instructions in Typical Installations and Installation Guide. c) Remote Electronics enclosure conduit entry locations for AWR series models are shown in Dimensions Remote Enclosure. Remove the terminal cover by loosening the two captive screws. Use a flat blade screwdriver and a slight tap to remove the selected conduit entry openings in the front of the enclosure. Follow the installation instructions in the Installation Guide and Wiring Diagram sections. Be careful to seal any unused cable glands. When wiring is complete, ensure the cable glands are securely sealed against the enclosure and the cable, then seal the terminal cover by tightening the two screws. d) Integral Transmitter AWI series models have cable glands located at the rear of the housing which face downward to protect against moisture ingress. Ensure that cable glands are securely tightened to adequately seal the cable. Be careful to seal any unused cable glands. e) Correct wiring. Follow the instructions in the Wiring Diagram sections. Wiring should be in accordance with relevant installation standards for hazardous area equipment or other local codes of practice. f) Safe temperature. Temperature must not exceed the operating range of the Sultan unit. In particular, Ex rated equipment must not exceed the temperature limits shown on the marking label. g) Safe power supply. Power supply values must be according to the Specifications. h) It is advised to provide a cover for the unit to prevent damage that could happen due to environmental conditions. i) Do not put into service where there is a possibility of contact with acetic acid. 4. Use The instructions for safe use of the Sultan Unit is as follows: a) The Sultan equipment must put into service safely. (see Putting Into Service, above). b) This User Manual must be read and understood by any person involved with the unit. c) Environment and installation conditions should be checked regularly. d) When opening the cover of the any Sultan unit, prevent dust, liquids or chemical substances from getting inside the unit. Do not leave any cover open in rain or snow conditions. 02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 2 of 13 Hawk Measurement Systems Pty Ltd

e) The LCD display is visible through the clear lid of the AWR series Sultan Remote Electronics enclosure. To view the LCD display on the AWI series Sultan Integral Transmitter, open the visor by lifting up the front edge with a finger. Close and click into place again after viewing so that the display is protected from environmental effects. f) Before making any wiring or hardware configuration changes, it is important to disconnect power from the equipment. 5. Assembling and dismantling The only assembly that may be required by the user is to reconfigure a Sultan 234 unit (2,3,4 wire operation) to that of a Sultan 2 unit (2 wire operation). This flexibility is unique to Sultan equipment. To safely reconfigure a Sultan 234 model to that of a Sultan 2 model: a) Make sure that the original unit is a Sultan 234 model (eg, AWI234 or AWR234). It is not possible to reconfigure a Sultan 2 model (eg, AWI2 or AWR2) as a Sultan 234 model. Only Sultan 234 models can be reconfigured to operate as Sultan 2 models, and this modification is reversible. b) Disconnect the power to the Sultan 234 Unit. c) To do the modification, follow the instructions in Wiring Change Sultan 234 <=> Sultan 2. d) Modify the wiring to suit the new output configuration as shown in Wiring Diagrams. 6. Installation and Wiring Carefully follow Typical Installations, Installation Guide and Wiring Diagram sections. Follow all points listed in Putting Into Service, above. Wiring should be in accordance with relevant installation standards for hazardous area equipment (eg, EN 61241-14) or other local codes of practice. 7. Adjustment a) Sultan Integral AWI series models: To access the user controls, loosen the single captive screw sufficiently to release the lid. The lid can then be raised to one of two positions 1) vertical, 2) swung right back [hinge unlocks] to gain access to the cable wiring located under the interior hinged cover flap. To close the lid, ensure that the double hinge at the top of the enclosure is locked into place before re-tightening the lid fastening screw. 02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 3 of 13 Hawk Measurement Systems Pty Ltd

b) Sultan Remote Electronics AWR series models: To access the user controls, unlock the clear cover using the lever on the right hand side of the clear lid. Press this lever in the direction of the arrow (towards the lid) to release the catch. The lid can then be swung open to gain access to the user control push buttons. Close the lid when finished. To lock the lid, press on the lower part of the lever, which moves the arrow symbol (in reverse) slightly away from the lid, locking the lid closed. c) Change of output configuration: The only other hardware adjustment that may be desired by the user is converting from the Sultan 234 output configuration to the Sultan 2 output configuration. Refer to Assembling and Dismantling, above. d) Software Adjustment: For software adjustment of Sultan unit parameter adjustment and data entry, refer to instructions in Entering Data, and all of the Setup sections. If GosHawk II software is to be used for parameter adjustment and data entering from a lap-top computer, read and fully understand the information in the GosHawk II Manual either supplied with the equipment or downloaded free from the Hawk website: http:// 8. Application Conditions a) Voltage Supply: Must be according to the voltage supplies given in Specifications. b) Temperature: Must not exceed the operating temperature range stated in Putting Into Service, above. To prevent inaccuracies due to extremes in temperature and the effect of long term UV exposure, it is recommended that transducers constructed with grey/beige polypropylene housing material be protected from direct sunlight. This does not apply to the blue/green and dark grey plastic enclosure parts. These parts have better UV stability. c) Cable Connection: Cables must only be replaced by the same cable type. If extending the cable, it must be protected in a junction box and terminated in an enclosure suitable for the environment. Refer to Wiring Diagrams Transducer. d) Earthing: Hawk Sultan Acoustic Wave equipment must be earthed to ensure that shielded cabling is effective. 02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 4 of 13 Hawk Measurement Systems Pty Ltd

e) Electrostatic Discharge: Hawk Sultan Acoustic Wave equipment has been certified safe to use in hazardous dust locations. The marking label warns to not rub the surface with a dry cloth if equipment is installed in a hazardous gas location. Special Condition of Safe Use: When installed in a Zone 0 Hazardous Area, precautions shall be taken to ensure that the plastic body of the transducer cannot become electro-statically charged. f) Industrial Conditions: This equipment is designed for use in normal industrial conditions relating to humidity, vibration, etc. If the user intends to operate the equipment in more severe environmental conditions, the manufacturer or local distributor should be consulted for advice. 9. List of ATEX certified equipment types: Sultan Acoustic Wave Remote Electronics Sultan Acoustic Wave Remote Transducer Sultan Acoustic Wave Remote Sonar Transducer Sultan Acoustic Wave Integral Transmitter AWR series AWRT series AWRT Sonar Series AWI series Flange, Cone and Accessory Selection in any combination. 10. Intrinsic Safe configuration drawings: Note: All equipment in Zone 0 Hazardous area must have ATEX Cat 1 marking. HAW_RD_WIR-ATEX-A1-A0_.jpg HAW_RD_WIR-ATEX-A2-A0_.jpg HAW_RD_WIR-ATEX-A3-A0_.jpg HAW_RD_WIR-ATEX-B1-A0_.jpg HAW_RD_WIR-ATEX-B2-A0_.jpg HAW_RD_WIR-ATEX-B3-A0_.jpg HAW_RD_WIR-ATEX-F2-A0_.jpg HAW_RD_WIR-ATEX-F3-A0_.jpg 02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 5 of 13 Hawk Measurement Systems Pty Ltd

02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 6 of 13 Hawk Measurement Systems Pty Ltd

02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 7 of 13 Hawk Measurement Systems Pty Ltd

02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 8 of 13 Hawk Measurement Systems Pty Ltd

02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 9 of 13 Hawk Measurement Systems Pty Ltd

02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 10 of 13 Hawk Measurement Systems Pty Ltd

02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 11 of 13 Hawk Measurement Systems Pty Ltd

02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 12 of 13 Hawk Measurement Systems Pty Ltd

02 Safety Instr v2 ATEX Cat1 GD (A0_Sultan).doc Page 13 of 13 Hawk Measurement Systems Pty Ltd