GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

Similar documents
GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

AMVM97 (B) / ACVM97 (B)

ComfortNet -Compatible

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

TECHNICAL MANUAL. GMH95 40" 95% Gas Furnace

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GMS9/GCS9 SERIES 93% AFUE

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

AVPTC. Air Handlers 1½ to 5 Tons

AVPTC Multi-Position, Internal Txv

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

GKS9 40" 90% Gas Furnaces

TECHNICAL MANUAL. ACVC9/AMVC95 GCVC9/GMVC95 90% UP TO 96% Gas Furnace Units

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

AVPTC. Air Handler 1½ to 5 Tons

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

FG7T (C and L Series)

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

MBR. Multi-Position. Modular Blower

RG7D 1-Stage Heat Series

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Technical Information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

T9MPV SmartComfort VS90 Product Specifications

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Wt. Lbs Model Number (BTUH) Hz

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

MULTI POSITION GAS FURNACE

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

13 GEP A L P - 1 A

Cooling Capacity CFM in. w.c. (125 Pa)

TECHNICAL SPECIFICATIONS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

TECHNICAL INFORMATION MANUAL

TECHNICAL SPECIFICATIONS

40 Residential Gas Furnace Operation

MERIT SERIES Downflow

TECHNICAL INFORMATION MANUAL

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Upflow/Horizontal Condensing, Gas-Fired Furnace

G6RC Series TECHNICAL SPECIFICATIONS

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Transcription:

(B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Specifications...5 Wiring Diagram... Standard Features Integrated communicating omfortbridge Technology ommissioning and diagnostics via on board Bluetooth with the oolloud phone and tablet application Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Two-stage gas valve provides quiet, economical heating Durable Silicon Nitride igniter Quiet two-speed induced draft blower ompatible with any single-stage thermostat Self-diagnostic control board with constant memory fault code history output to a triple 7-segment display olor-coded low-voltage terminals with provisions for electronic air cleaner Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand Multiple continuous fan speed options offer quiet air circulation Auto-omfort and enhanced dehumidification modes available All models comply with alifornia 0 ng/j Low x emissions standard For installation in alifornia s South oast Quality Management District (SAQMD) only: This furnace does not meet the SAQMD Rule ng/j x emission limit, and thus is subject to a mitigation fee of up to $50. This furnace is not eligible for the SAQMD lean Furnace Rebate Program: www.leanfurnacerebate.com. AHRI ertified; ETL Listed abinet Features Designed for multi-position installation downflow, horizontal left or right ertified for direct vent (-pipe) or non-direct vent (-pipe) Easy-to-install top venting with optional side venting onvenient left or right connection for gas and electrical service abinet air leakage % Heavy-gauge steel cabinet with durable finish Fully insulated heat exchanger and blower section tight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications * omplete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 0-Year Unit Replacement Limited Warranty and 0-Year Parts Limited Warranty, online registration must be completed within 0 days of installation. Online registration is not required in alifornia or Québec. SS- www.goodmanmfg.com 0/8 Supersedes 9/8

Nomenclature G V 9 00 B N ** 5, 7,8,9 0, Brand G - Goodman Brand Engineering Major / Minor Revisions * Not used for inventory control. onfiguration x M - Upflow/Horizontal N - Low x - Downflow/Horizontal abinet Width Motor B - 7½ - " V - Variable Speed EM / omfortbridge D - ½" E - Multi-Speed EM S - Single Speed Maximum FM - 800 FM - 00 FM Gas Valve - 00 FM 5-000 FM M - Modulating - Two- Stage MBTU/h S - Single Stage 00-0,000 BTU/h 00-0,000 BTU/h AFUE 0-0,000 BTU/h 97-97% AFUE 9-9% AFUE 9-9% AFUE Accessories Model Description 00BNB 00BNB 080NB 005NB 05DNB VENT- oncentric Vent Kit (") --- VENT- oncentric Vent Kit (") FSB7 Downflow Sub-Base 7.5" --- --- --- FSB Downflow Sub-Base " --- --- --- FSB Downflow Sub-Base " --- --- --- --- RF000 Drain Kit -Horizontal Left Vertical Flue 070K00000S Flush Mount Vent Kit - " or " 070K0000S Flush Mount Vent Kit - " --- HASFK High-Altitude Natural Gas Kit HASFK- HASFK- HASFK- HASFK- HASFK- HASFK High-Altitude LP Gas Kit HASFK- HASFK- HASFK- HASFK- HASFK- LPLP0 Low LP Gas Pressure Switch LPM-08 LP onversion Kits www.goodmanmfg.com SS-

Product Specifications 00BNB 00BNB 080NB 005NB 05DNB Heating Data High Fire Input¹ 0,000 0,000 80,000 00,000 0,000 High Fire Output¹ 8,00 57,00 7,800 9,000 5,00 Low-Fire Steady-State Input¹ 8,000,000 5,000 70,000 8,000 Low-Fire Steady-State Output¹,880 0,0 5,70 7,00 80,0 AFUE² 9 9 9 9 9 Temperature Rise Range ( F) 0-50 5-5 5-55 5-75 5-5 Vent Diameter³ " - " " - " " - " " - " " - " No. of Burners 5 irculator Blower Available A @ 0.5" ESP.5 -.5 -.5 - - 5-5 Size (D x W) 0" x 8" " x 8" " x 0" " x 0" " x " Horsepower @ 075 RPM ½ ½ ¾ Speed VS EM VS EM VS EM VS EM VS EM Electrical Data Min. ircuit Ampacity⁴ 7.8 7.8 0... Max. Overcurrent Device (amps)⁵ 5 5 5 0 0 Shipping Weight (lbs) 9 5 58 ¹ Natural Gas BTU/h ² DOE AFUE based upon Isolated ombustion System (IS) ³ Installer must supply one or two PV pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either " or " in diameter, depending upon furnace input, number of elbows, length of run and installation ( or pipes). The optional ombustion Pipe is dependent on installation/code requirements and must be " or " diameter PV. ⁴ Minimum ircuit Ampacity = (.5 x irculator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HAR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on 5 VA, 0 Hz, single-phase electrical supply. Gas Service onnection ½" FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical ode and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 8%. This could result in performance and noise issues. For servicing or cleaning, a " front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS- www.goodmanmfg.com

Dimensions ⅜ ⅝ ⅞ A B ⅝ ½ ⅞ ½ 8¼ Alternate Vent/ ½ Low-Voltage Low-Voltage Alternate Gas High-Voltage ½ 5⅛ Alternate Gas Supply ¾ 5⅛ ⅞ ¾ ⅛ ⅞ ⅜ ⅜ ⅞ Drain Trap Holes Standard Drain Trap 8¾ Discharge ½ ½ D Unfolded Flanges E Folded Flanges Front View High-Voltage ⅝ Right Side Exterior Drain Trap Holes 8⅛ Unfolded Flanges 0⅛ Folded Flanges Right-Side View Discharge Return Discharge Model A B D E 00BNB 7½" ⅝" " ½" " 00BNB 7½" ⅝" " ½" " 080NB " 8⅛" 7½" 8" 9½" 005NB " 8⅛" 7½" 8" 9½" 05DNB ½ ⅝" " ½" " Minimum learances to ombustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0" 0" " N 0" " Horizontal " 0" " 0" " = If placed on combustible floor, the floor MUST be wood ONLY. N = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring. Minimum Filter Sizes Filter Size (in²) (Qty) 00BNB 00BNB 080NB () 0 x 0 or () x 5 (top return) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. 005NB 05DNB () x 0 (bottom) or () 0 x 5 (top return) www.goodmanmfg.com SS-

flow Data MODEL/TEMP RISE RANGE (MID RISE) 00BNB* 5-5 (50) 00BNB* 0-50 (5) 080NB* 5-55 (0) 005NB* 5-5 (50) 05DNB* 5-5 (50) FM RISE FM RISE FM RISE FM RISE FM RISE Recommended cfm for high heat / expected temperature rise Lowest recommended cfm for hi heat / expected temperature rise Maximum cfm for hi heat / expected temperature rise 70 50 00 8 70 0 770 50 50 50 58 5 07 50 90 55 0 5 50 5 00 5 00 8 70 0 00 0 00 8 TE: Low Heat FM = High Heat FM X.7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± 5% 00F00-A 00BNB* ooling Speed FM 00BNB* ooling Speed FM.5 00 0.5 00 0 800 50 800 50.5,000 700.5,000 700,00 80,00 80 MAX,00 MAX,00 080NB* ooling Speed FM 005NB* ooling Speed FM 800 50 800 50.5,000 700,00 80,00 80,00,0,00 0 5,000,00 MAX,70 MAX,00 05DNB* ooling Speed FM 800 50,00 80,00,0 5,000,00 MAX,00 All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 00 FM per ton when cooling is desirable. Do not operate above.5 w.c. ESP in heating mode. Operating FM between.5 and.8 w.c. is tabulated for cooling purposes only. SS- www.goodmanmfg.com 5

HUM DEHUM Wiring Diagram GR YL BR TES: HOT SURFAE IGNITER IRUIT ONNET EM MTR HARNESS TWO STAGE GAS VALVE (ITE-RODGERS) LOW FIRE PRESSURE SWITH. SET HEAT ANTIIPAT ON ROOM THERMOSTAT AT 0.7 AMPS.. MANUFATURER'S SPEIFIED REPLAEMENT PARTS MUST BE USED EN SERVIING. BR AU RESET PRIMARY GN ONTROLS (SINGLE ONTROL ON LIMIT ONTROL HI PM MANUAL RESET ROLLOUT LIMIT BURNER OMPARTMENT 0 kbtu) OWER OMPARTMENT AU RESET AUXILIARY LIMIT ONTROL ONDENSATE SWITH (OPTIONAL) 0 IN 7 5 OUT EM FUSE A IRULAT OWER 5 ID OWER TWO-STAGE PRESSURE GR SWITH ASSEMY FRONT OVER PRESSURE SWITH. IF ANY OF THE IGINAL WIRE AS SUPPLIED WITH THE FURNAE MUST BE REPLAED, IT MUST BE REPLAED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 05$. USE OPPER ONDUTS ONLY.. UNIT MUST BE PERMANENTLY GROUNDED AND ONFM N.E.. AND LOAL ODES. YL 5 8 9 ONDEN -SATE UEOTH BOA FS LINE R INDUED OWER DRAFT EA IGN-N IND-N IND-LO IND-HI IGN 5 ENTER LEFT RIGHT RAT NA SAT R G W Y DE INDUT OIL (ON SOME MODELS) HIGH FIRE PRESSURE SWITH BR BR YL 0 VA TRANSFMER OL ODES: PINK BR BROWN ITE UE GRAY RED YL YELLOW ANGE RPLE GN GREEN AK FLAME SENS GN VA 5 VA JUNTION BOX HASSIS GROUND OWER OMPARTMENT DO SWITH (OPEN EN DO OPEN) INTEGRATED ONTROL MODULE V THERMOSTAT ONNETIONS WIRING UNIT R Y 5VA/ Ø /0 HZ POWER SUPPLY WITH W G R WARNING: GROUNDED. FUSE A MIRO MIRO OVERURRENT PROTETION DEVIE DISONNET POWER BEFE SERVIING. MUST BE PROPERLY POLARIZED AND DO SWITH INDUT OIL (ON SOME MODELS) LINE LINE LOW VOLTAGE (V) LOW VOLTAGE FIELD HI VOLTAGE (5V) HI VOLTAGE FIELD JUNTION EA IGN +VD TERMINAL INTERNAL INTEGRATED ONTROL PLUG ONNETION DISONNET FS TH () AU RESET AUXILIARY LIMIT ONTROLS HLO (0) PSO (7) PS () PS () HLI () MVL () (5) TR () HIGH FIRE PRESS. SWITH MVH () MV (8) () + VD () RX () TX () IND HI INTEGRATED ONTROL MODULE L JUNTION BOX IND LO HLI () HLI () INDO AIR IRULAT WR ELETRONI AIR LEANER L N ID WR HOT SURFAE IGNITER FLAME SENS 5 VA/ Ø /0 HZ POWER SUPPLY WITH OVERURRENT PROTETION DEVIE 5 VA VA WARNING:DISONNET POWER BEFE SERVIING. WIRING UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. INDO AIR IRULAT WR N 0 VA TRANSFMER MANUAL RESET ROLLOUT LIMIT ONTROLS FRONT OVER PRESSURE SWITH FIELD FIELD SPLIE DISONNET EQUIPMENT SWITH (TEMP.) IGNITER SWITH (PRESS.) OVERURRENT PROT. DEVIE AU RESET PRIMARY LIMIT ONTROL LOW FIRE PRESS. SWITH PM HI GAS VALVE INTEGRATED ONTROL MODULE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. 00F00- Goodman Manufacturing ompany, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 08 Goodman Manufacturing ompany, L.P. Houston, Texas www.goodmanmfg.com SS-