DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS

Similar documents
DEMA 830 Laundry Master TM Installation Instructions

PINNACLE WAREWASH CONTROL By DEMA DP-812-DL-1T DP-813-DLL-1T DP-812-LL-1T DP-813-LLL-1T Introduction

DEMA 832 LAUNDRY MASTER TM INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL FOR DEMA CHEMASTER TM DM-813-LLL-1T, DM-813-LLL-2T, DM-813-DLL-1T and DM-813-DLL-2T

DEMAMaster Nitro Express Ware Wash Chemical Dispenser

DEMA SOLID PRODUCT LAUNDRY MASTER TM MODEL: 581L-1W and 581L-2W INSTALLATION INSTRUCTIONS

DEMAMaster Nitro Express Ware Wash Chemical Dispenser

DEMA CHEMASTER WAREWASH SYSTEM INSTALLATION AND OPERATIONS MANUAL

DEMA Nitro Express Ware Wash Chemical Dispenser

DEMA TITAN EP II WAREWASH CONTROL TE.812 & TE.813 SERIES

DEMA Nitro Ware Wash Chemical Dispensing

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

DEMA TITAN II WAREWASH CONTROL T.812 & T.813 SERIES

DEMA PROPORTIONER MODEL 167 & 167T INSTALLATION INSTRUCTIONS

DEMA TITAN WAREWASH CONTROL T-812 & T-813 SERIES

WAREMAX SERIES. Dosing Systems for Commercial Dishmachines. Contents. WAREMAX Series Dishwasher systems. 4 Priming and Delime Mode.

DEMA 844 Laundry Master Laundry Chemical Dispensing

ProPet Washer. I-1020 Page 1 of 6 Rev. D /15/11

ENCLOSED UNIT TECHNICAL MANUAL Items # &

Sprite III Warewash Dispensing System

DEMA I /23/18. detergent and. responds to. rinse triggers. of a pressure indicating. plumbing

SPRITE Warewash Dispensing System

Owner s Manual RD432-0 Chemical Controller

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

D3000. Installation & Setup Guide

M770 ph Controller Owner s Manual

NS1000E Installation & Troubleshooting

D3000. Installation and Operating Manual SAFETY D3000 SPECIFICATIONS PRODUCT DESCRIPTION

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

Sprite III (Alpha) Warewash Dispensing System

M790 ph/orp Controller. Owner s Manual

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

Antares Warewash Dispensing System

MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10

Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00

Warewash Systems. innovation > technology > future

CP-200 S&T. CP Warewash Pump Instruction & Operation Manual Speed & Time , Rev1.0, , Page 1 of 8

OPERATING MANUAL/ INSTALLATION

Owner s Manual GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.00

QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions

KLE-235D DOUBLE RACK IN-LINE CONFIGURATION KLE-175GTM SINGLE RACK THREE-DOOR CONFIGURATION KLE SERIES ULTRA WASH DISHMACHINE INSTRUCTION MANUAL

Warewashing individual and integrated systems

Knight Trak II Instruction Manual

Sacksafoam Heli-Case Operations Manual - Version A Issue Date: April 2017 PLEASE READ BEFORE USING

Warewash systems. innovation > technology > future

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Antares Warewash Dispensing System

Installation, Operation & Maintenance Manual. Wash System

Operating Instructions for the BBO-1 and BBO-2 Basket Blasters

14 Upright Vacuum with HEPA Filter & Dual Power

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

INSTALLATION AND OPERATION INSTRUCTIONS LC-D SERIES COFFEE CONCENTRATE BREWER WITH DIGITAL ELECTRONIC CONTROL CENTER

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Viking Installation Guide

Retro Fit Rinse Pump Rev B

MODEL CMA-180UC PARTS MANUAL Rev 1.16

Dispensing Systems. Warewash, Laundry, Drain & Deodorizing Chemical Systems PRODUCT CATALOG.

Chem-Trak Installation & Operation

Installation Manual with Service Replacement Parts

Liberty-Classic. Operator s Manual

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02B

BOTTLED WATER DISPENSER DISPENSADOR DE AGUA EMBOTELLADA

P/N CC-100. Coolant Circulator. Operation manual

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

MODELS CMA-180 VL/180 VLTall PARTS MANUAL Rev 2.02A

M820 ph/dual ORP Controller. Owner s Manual

Wilbur Curtis Company, Inc. Service Manual WB5GT Water Boiler

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

OPERATING MANUAL/ INSTALLATION

MAINTENANCE MADE EASY

Installation Instructions for Kay Chemical / Power Soak Dual Dispenser Pump (01/02/03)

DISCARD DECANTER IF: FAILURE TO COMPLY RISKS INJURY FUNNEL CONTENTS ARE HOT ILLUSTRATED PARTS CATALOG

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES

Fountain Classic. Installation and Owner s Manual. Page 16

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Wilbur Curtis Company, Inc. Service Manual WB-10 Water Boiler

Models: FM FM WARNING

INSTALLATION and OPERATION INSTRUCTIONS

CATALOG OF REPLACEMENT PARTS

SD2000 FLOOR BURNISHER

DISCARD DECANTER IF: FUNNEL CONTENTS ARE HOT FAILURE TO COMPLY RISKS INJURY

Dosing systems for dishwashing machines TWINDOSE SERIES

REPLACEMENT PARTS MANUAL

Wilbur Curtis Company, Inc.

REPLACEMENT PARTS MANUAL

MEIKO Undercounter Dish and Glass Washing Machine. Spare Parts List 208V/230V 1/3-PHASE 60 HZ

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

Frosty Factory of America, Inc.

COMMERCIAL STACKED. Supersedes repair parts list located behind lower panel on washer. Models: CGT8000AQ1 (White)

Owner s Manual. MODELS AH/B/C/Scullery/Pizza/Bowl INSTALLATION & OPERATION Rev 1.01A

ALTAIR II CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

NHR-25 Feed Hopper with Agitator

Instruction Manual. Nacho Cheese Dispenser and Warmer

DR30 MAX Warewash Chemical Dispenser Dispensing technology by Seko UK

INSTALLATION INSTRUCTIONS

REPLACEMENT PARTS MANUAL

SINGLE BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

Transcription:

DEMA 813 PROBELESS DEMAMaster TM INSTALLATION INSTRUCTIONS Models: DM-813-PLLL-1T DM-813-PDLL-1T DM-813-PLLL-2T DM-813-PDLL-2T I-729 Pg 1 of 15

System Overview The DEMA DEMAMaster probeless series is designed for long reliable use with simplicity in mind for both the installer and user. The system is based on the reliable DEMA peristaltic pump. The pumps are installed in a heavy plastic housing with a sealed cover that uses a Lexan label with visible function indicators. Pumps are available with three different motor/gear box speeds, 15, 0, and 105 RPM. There are micro controllers housed in the unit that control the operation of the pumps. The detergent pump is controlled by a set of DIP switches that can be arranged to supply a selected amount of detergent based on door counts or time depending on the application. The rinse aid is set by a potentiometer that controls the speed of pump and can be delayed up to 12 seconds. In addition, the probeless detergent board has the ability to keep track of time and deliver a new initial charge when in the door mode. The DEMAMaster is supplied with a transformer mounted in housing that allows primary voltage hook up of 120, 208 or 240 at 50/0Hz. Please read all instructions before proceeding with the DEMAMaster installation. Dishroom Room Survey A complete survey of the dish machine sight should be completed before the DEMAMaster installation. 1. Locate the power connection points on the dish machine. This power must be 120, 208 or 240 volts 50/0Hz. Note: When installing a DEMAMaster probeless on a door operated dish machine, keep in mind that the detergent control will need to recognize door openings based on power on and off to the DEMAMaster. In addition, all installations will require that the rinse control recognize the dish machine rinse cycle. 2. Select location to mount the DEMAMaster on a wall that will allow access to the chemical product containers and the chemical product feeds points on the dish machine. The DEMAMaster should be kept away from moisture releasing machinery and from water being splashed directly on the unit. 3. Mount the DEMAMaster on a wall by use of the supplied hanger. Use appropriate wall anchors when mounting on dry wall. I-729 Pg 2 of 15

Electrical Installation This product is designed only to be used as described in this instruction sheet. Adhere to all warnings and cautions identified in this document. WARNING: Electrical and grounding installation of DEMA products must comply with electrical codes and regulations established by national, city, county, parish, provincial or other agencies. It is possible that electrical codes and regulations require that a certified electrical contractor or engineer perform the electrical installation. For questions, contact a certified electrician. DISCONNECT ALL ELECTRICAL POWER TO THE DISPENSER AND THE APPLIED MACHINE WHEN SERVICING- FOLLOW LOCKOUT / TAGOUT PROCEDURES. WARNING: Installations must conform to all local and national plumbing codes and use approved backflow prevention and pressure relief devices where required. ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER IS NOT IN USE. Always read SDS for all chemicals used and follow personal protective guidelines. 1. BEFORE GOING ANY FURTHER, ALL ELECTRICAL POWER MUST BE TURNED OFF TO THE DISH MACHINE AND ANY OTHER CIRCUIT THAT IS TO BE USED FOR THIS INSTALLATION. LOCKOUT AND TAG PROCEDURES SHOULD BE OBSERVED WHEN INSTALLING THIS DEVICE. NEVER OPEN THE DEMAMASTER UNLESS POWER HAS BEEN TURNED OFF. SIGNALS MAY BE PRESENT FROM DISH MACHINE, EVEN WITH THE POWER TURNED OFF. ONLY USE ELECTRICAL CODE APPROVED INSULATED WIRING AND ELECTRICAL FIXTURES WITH THIS INSTALLATION. Note: The DEMAMaster is equipped with 1 or 2 transformers depending on the model. If there are 2 transformers, the detergent control will be powered by one while the rinse aid control, will be powered by the other. If the DEMAMaster is equipped with 1 transformer, both the detergent and rinse control, will be powered by the same transformer. In this case it will be necessary to wire the unit so that the rinse aid control will only run during the rinse cycle. This can be done via a pressure switch, which should be wired to the DEMAMaster terminal block connections labeled pressure switch. 2. Connect the power to the DEMAMaster. The DEMAMaster will accept 120VAC, 208VAC or 240VAC 50/0Hz. The detergent control is normally wired to something that is common to the pump operation, thus signaling a wash cycle. The rinse control is normally wired to something that is common to the rinse solenoid valve, thus signaling a rinse cycle. Some dish machines may have a terminal block setup for power for both detergent and rinse, see schematic or owners manual of the dish machine to determine if this option is available. I-729 Pg 3 of 15

3. Locate the power terminal block inside the DEMAMaster enclosure. There will be 2 when there are 2 transformers. Connect hot or live wire to the terminal labeled line. Connect the return line to the appropriate terminal block position based on supply voltage. The earth ground wire must be connected to the terminal block by use of the grounding clip (supplied in installation kit). The power line should be secured by use of a proper electrical fitting through access hole in DEMAMaster enclosure. The power line must also be secured properly between the dish machine or power source and DEMAMaster. Note: When wiring is completed the DEMAMaster should feed detergent based on door counts or time depending on type of machine (door or conveyor). The rinse aid should feed only during the rinse cycle. It may be necessary to use a pressure switch to signal the rinse aid feed. Evaluate the application for requirements to assure proper operation. I-729 Pg 4 of 15

PROBLESS DETERGENT CONTROL BOARD 80-77-1 + 24VDC OUT 24VAC IN 24VAC OUT RINSE CONTROL BOARD 80-9- UNUSED 24VAC IN + 24VDC SANI OUT + 24VDC RINSE OUT X20753-2 (81-32-2) MOTOR X20753-7 (81-32-7) VALVE X20753-1 (81-32-1) MOTOR X20753- (81-32-) VALVE MOTOR X20753-2 (81-32-2) SANI X20753-1 (81-32-1) X20753-2 (81-32-2) (SEE DRAWING FOR PART NO.) X20753-1 (81-32-1) MOTOR RINSE 40 VA TRANSFORMER 80-70 20759-2 (81-3-2) 25457-1 (81-34-1) FUSE 20758-1 (81-35) FUSE HOLDER 1A. 250V FUSE WHITE LINE 120VAC RETURN BLUE 208VAC RETURN 240VAC RETURN TERMINAL BLOCK & BRACKET ASSY. 25457-1 (81-34-1) FUSE 20758-1 (81-35) FUSE HOLDER 20759-2 (81-3-2) 1A. 250V FUSE WHITE LINE 120VAC RETURN BLUE 208VAC RETURN 240VAC RETURN 40 VA TRANSFORMER 80-70 DETERGENT MOTOR OR SOLENOID VALVE TERMINAL BLOCK & BRACKET ASSY. I-729 Pg 5 of 15

PROBLESS DETERGENT CONTROL BOARD 80-77-1 + 24VDC OUT 24VAC IN 24VAC OUT RINSE CONTROL BOARD 80-9- UNUSED 24VAC IN + 24VDC SANI OUT + 24VDC RINSE OUT 20774-1 (81-94-1) X20753-1 (81-32-1) RINSE MOTOR X20753-1 (81-32-1) SANI MOTOR X20753-2 (81-32-2) X20753-2 (81-32-2) 25457-1 (81-34-1) FUSE 20758-1 (81-35) FUSE HOLDER 20759-2 (81-3-2) 1A. 250V FUSE WHITE TERMINAL BLOCK & BRACKET ASSY. LINE 120VAC RETURN BLUE 208VAC RETURN 240VAC RETURN 40 VA TRANSFORMER 80-70 20774-1 (81-94-1) 20774-2 (81-94-2) 1 2 PRESSURE SWITCH X20753-1 (81-32-1) MOTOR X20753- (81-32-) VALVE X20753-2 (81-32-2) MOTOR X20753-7 (81-32-7) VALVE DETERGENT MOTOR OR SOLENOID VALVE I-729 Pg of 15

Tubing Connections Included in the installation kit is a roll of low-density polyethylene (LDPE) tubing that can be used to connect from the chemical container, to the pump, and from the pump to the injection fittings on the machine. Measure the length of the tubing needed on the suction side from the chemical container to the pump and cut the tubing to proper length. Install the tubing into the pickup tubes (Grey PVC) through the compression nut, and tighten the nut. Route the tubing to the suction side of the pump. An arrow on the faceplate indicates the flow direction. Push the tubing into the pump squeeze tube approximately1/2-3/4 (15-20mm). Secure the tubing with a tie wrap around the squeeze tube. Use the same procedure on the outlet of the squeeze tubing and route the LDPE tubing to the injection point of the machine. Cut off all excess tubing and keep tubing away from hot surfaces and sharp edges to prevent damage or leakage. See Detergent and Rinse Tubing Connections below for specific information concerning discharge tube connection. Detergent Tubing Connections Included with the kit is a bulkhead fitting that will accept the discharge of the detergent at the machine. There are two fittings depending on the model. If the DEMAMaster has a detergent pump, then the fitting will have a ¼ compression fitting that will accept the ¼ LDPE pump discharge tubing. It the unit has a solenoid valve then the fitting will have a barb fitting designed for a 5/8 I.D. tube. A 7/8 diameter hole will need to be cut above the waterline in the side of the dish machine wash tank to accommodate the bulkhead fitting. The bulkhead fitting should not be located above the concentration probe. When using the detergent pump simply run the tubing from the outlet of the pump to the ¼ compression fitting on the bulkhead fitting. When using the solenoid valve run the ¼ LDPE tubing from the ¼ compression fitting on the outlet of the valve to the siphon breaker for the solid bowl or powder feeder. Rinse Tubing Connections Note: A check valve is included in the installation kit. The procedure below describes the installation of this check valve. Other hardware may be needed to complete the installation properly. Install ¼ compression by 1/8 NPT rinse injection check valve into the rinse input water between the vacuum breaker and the final rinse arm. Drill an 11/32 hole and tap to 1/8 NPT. When installing to copper pipe or tubing use saddle clamps. Connect the ¼ OD poly tubing between the ¼ rinse check valve and the discharge side of the peristaltic rinse squeeze tubing. Use a plastic tie to hold the ¼ polypropylene tubing into the peristaltic squeeze tube. Detergent and Rinse Calibration Detergent Prior to calibration the system must be primed. The system is primed when the chemical is dispensing from the injection point into the dish machine tank. This can only be done while power is being supplied to the probeless detergent board. By pressing the button on the front cover labeled detergent prime the pump will run. Simply press and hold until the pump and tubing has been primed. Note: If Detergent Prime button is held less than 5 seconds, the pump will run for the amount time that has been set for initial charge or until button is pushed again. I-729 Pg 7 of 15

The detergent set up involves the use of the DIP switches on the pro-bless detergent control board. There are a bank of and a bank of 8 switches located directly on the control board. The detergent concentration should be setup so that the desired level of concentration is maintained while the dish machine is being used. The concentration can be tested by use of a titration test kit (DEMA P/N 81-53), not included. 1. Door or Conveyor mode: DIP Switch Bank, Switch 1 45 5 2. Initial Charge Time: Sets the amount of Initial Charge based on time. See table below for the P switch configuration. 0 1 MIN 1 MIN 50 SEC 5 SEC 1 MIN 5 SEC 1 MIN 55 SEC 10 SEC 1 MIN 10 SEC 2 MIN 15 SEC 1 MIN 15 SEC 45 78 2 MIN 5 SEC 20 SEC 1 MIN 20 SEC 2 MIN 10 SEC 4 25 SEC 1 MIN 25 SEC 45 78 2 MIN 15 SEC 30 SEC 1 MIN 30 SEC 4 2 MIN 20 SEC 35 SEC 1 MIN 35 SEC 2 MIN 25 SEC 40 SEC 1 MIN 40 SEC 2 MIN 30 SEC 4 45 SEC 4 1 MIN 45 SEC 45 7 8 2 MIN 35 SEC 50 SEC 55 SEC 1 2 3 4 I-729 Pg 8 of 15

3A. Dead Cycle Count Door Mode Only Sets the amount of wash cycles (door operations) that will take place before a recharge will occur. See table below for DIP switch configuration. Example: If the Dead Cycle Count is set to 3, there will be three wash cycles where no detergent will be added. On the 4 th cycle a recharge will occur. 0 CYCLES 5 4 CYCLES 1 234 5 1 CYCLE 5 5 CYCLES 5 2 CYCLES 5 CYCLES 1 234 5 3 CYCLES 5 7 CYCLES 1 234 5 3B. Dwell Time Setting Conveyor Mode Only Sets the amount of time between a charge and a recharge and recharges. See table below for DIP switch configuration. Example: Dwell Time is set for 1 min 30 sec. After the probeless control supplies an initial charge or a recharge, 1 minute and 30 seconds must expire before the next recharge will occur. 0 5 3 MIN 4 5 5 MIN 30 SEC 5 15 SEC 45 3 MIN 15 SEC 1 2 3 4 5 5 MIN 45 SEC 4 5 30 SEC 4 5 3 MIN 30 SEC 1 2 3 4 5 MIN 5 45 SEC 4 5 3 MIN 45 SEC 4 5 MIN 15 SEC 4 5 1 MIN 45 4 MIN 4 5 MIN 30 SEC 5 1 MIN 15 SEC 5 4 MIN 15 SEC 5 MIN 45 SEC 5 1 MIN 30 SEC 45 4 MIN 30 SEC 4 5 7 MIN 5 1 MIN 45 SEC 5 4 MIN 45 SEC 1 234 5 7 MIN 15 SEC 4 5 2 MIN 45 5 MIN 5 7 MIN 30 SEC 4 5 2 MIN 15 SEC 5 5 MIN 15 SEC 4 5 7 MIN 45 SEC 5 2 MIN 30 SEC 45 2 MIN 45 SEC 4 5 I-729 Pg 9 of 15

4. Recharge Time: Sets the amount of recharge based on time. See table below for DIP switch configuration. 1 SEC 5 SEC 2 SEC SEC 1 2345 7 8 3 SEC 7 SEC 45 7 8 4 SEC 45 7 8 8 SEC 5. Initial Charge Clock This feature is adjustable as shown below while in door mode only. When the unit is in the conveyor mode the initial charge clock defaults to 1 hour. This feature is used to provide an initial charge after a set amount of time expired without using the DEMAMaster. See the table below for the DIP switch configuration. Example: Initial Charge Clock is set for 2 hours. If no power has been supplied to the probeless control for at least 2 hours, the pro-bless control will provide an initial charge the next time power is supplied. 15 MIN 5 2 HOURS 4 5 3 HOURS 4 5 4 HOURS 4 5 Note: The DEMAMaster probeless board is designed with a 5 second delay when powered up. This means that the detergent pump or valve will not operate until continuous power is supplied to the board for at least 5 seconds. I-729 Pg 10 of 15

Rinse Aid Calibration Prior to calibration the system must be primed. The system is primed when the chemical has filled the tubing up to the injection point. On the rinse side this can only be done during the time the rinse solenoid is active. On the front cover there is a button called prime. By depressing this, the pump will run at maximum speed. This may have to be done several times to ensure the chemical has filled up the entire tubing system. 1. Put the pick up tube into a measuring cylinder and fill with chemical to an easily read level. 2. Set the pump speed according to the chemical manufacturer s recommendations e.g. (2 oz/10 seconds). Calculation = 2oz x = 12oz/min. 12 oz divided by the capacity of the pump per revolution (1.5)=8 revolutions per minute or 8/=1.4 revolutions per 10 seconds (the rinse cycle). 3. Check level again and fill to mark if necessary and let pump run for at least five cycles and check the amount being injected. This will automatically compensate for back pressure, (pressure loss in tubing and etc.). 4. At this point the system is ready for operation. 5. The rinse delay may be set, by adjusting the potentiometer labeled rinse delay on the rinse board. A 0-12 second delay may be set.. There are 18 seconds of rinse limit available when the rinse limit jumper is in the on position. When the jumper is in the off position, there is no rinse limit. This means that the rinse pump will run through the entire rinse cycle, when jumper is in the off position. Sanitizer Calibration Prior to calibration the system must be primed. The system is primed when the chemical has filled the tubing up to the injection point. On the rinse side this can only be done during the time the rinse solenoid is active. On the front cover there is a button labeled Sani Prime. By depressing this, the pump will run at maximum speed. This may have to be done several times to ensure the chemical has filled up the entire tubing system. 1. Put the pick up tube into a measuring cylinder and fill with chemical to an easily read level. 2. Set the pump speed according to the chemical manufacturer s recommendations e.g. (2 oz/10 seconds). Calculation = 2oz x = 12oz/min. 12 oz divided by the capacity of the pump per revolution (1.5)=8 revolutions per minute or 8/=1.4 revolutions per 10 seconds (the rinse cycle). 3. Check level again and fill to mark if necessary and let pump run for at least five cycles and check the amount being injected. This will automatically compensate for back pressure, (pressure loss in tubing and etc.). 4. At this point the system is ready for operation. DEMAMaster Operation The user of the DEMAMaster only needs to perform the following: - Monitor the level of the detergent and rinse aid products. - When changing the detergent or rinse aid products, prime the pump by pressing and holding the Detergent Prime or Rinse Prime button until the pump and lines or primed. - If dish machine tank is emptied and refilled, an initial charge can be delivered by pressing the Detergent Prime button for less than 5 seconds. - The clock will deliver an initial charge if the unit is not powered up for the amount of time that has been programmed into the initial charge clock. Example: The dish machine is turned off at the end of a shift, at the start of a next shift the DEMAMaster will deliver an initial charge when powered up, providing that the initial charge clock has expired. I-729 Pg 11 of 15

28 29 OPTIONAL SOLENOID VALVE 30 31 32 33 35 13 1 14 14 34 5 34 7 9 3 8 9 2 (DETERGENT UNITS WITH 2 TRANSFORMERS) (UNITS WITH 1 TRANSFORMER) (FOR 812 MODELS) 1 (FOR 813 MODELS) 21 17 18 15 20 19 18 24 I-729 Pg 12 of 15

Item No. DEMA Part No. Qty Required Replacement Parts Description 1 81-2 1 DEMAMaster Double Control Box 2 81-5 1 DEMAMaster Double Control Box Lid 3 81-1 Hinge and Screw Kit 4 81-1 1 Mounting Bracket Kit 5 80-70 1 Transformer 40VA 81-10-1 1-Qty Model No. ends 1T 2 Qty Model No. ends 2T Terminal Block & Bracket Assy. (Detergent, units with 2 transformers) 7 81-10-2 1 Terminal Block & Bracket Assy. (Rinse, units with 2 transformers) 8 81-10-5 1 Terminal Block & Bracket Assy. (units with 1 transformer) 9 44-11-1 2 / Transformer # 8 x ½ HI-LO Screw (mounting transformer) 10 81-35 1 / Transformer Fuse Holder 11 81-34-1 1 / Transformer Fuse 1A, 250V 12 81-3-2 1 / Transformer Blue Wire Nut 13 80-59-0 1 0 RPM Gear/motor 14 80-59-15 1 / Rinse and 1 / Sanitizer 15 RPM Gear/motor 15 80-77-1 1 Pro-bless Detergent Control (circuit board for controlling detergent) 1 80-9-5 1 (for 812 Models) Rinse Control Board (circuit board for controlling rinse) 17 80-9- 1 (for 813 Models) Rinse & Sanitizer Control Board (circuit for controlling rinse and sanitizer) 18 81-20-2 3 / control board # 4 HI-LO Screw (mounting circuit boards) 19 80-99 1 Coin Cell Battery (CR2032) 20 81-13- 1 Modular Connector pole (for Pro-bless Detergent Control Board) 21 81-13-8 1 Modular Connector 8 pole (for Rinse and/or Sanitizer Control Board) 22 81-94-1 2 (1 transformer units) 18 AWG Orange Wire 8 long 23 81-94-2 1 (1 transformer units) 18 AWG Orange Wire 10 long 24 81-29-2 2 Captive Screw 25 81-47-1 1 Hole Plug 2 L04 1 Caution Label Electrical 27 L05 1 Caution Label - Chemical 28 44-125 1 Solenoid Cover 29 44-11-1 1 Cover Screw 30 44--4 1 Solenoid Valve-Detergent (Dry Feed Models) 31 44-124-2 2 Solenoid Mounting Screw 32 44-29 2 Lock Washer 33 44-90 2 Hex Nut 34 25-5RE-11 2 Squeeze Tube - Rinse 35 25-5CE-11 1 Squeeze Tube - Detergent I-729 Pg 13 of 15

25-7C2-2 25-85S 25-84C2 25-83C2-2 25-85L 25-91-C2 SQUEEZE TUBE C2 PUMP ASSEMBLY C2 Pump Parts Part No. Description 25-91-C2 C2 Pump Head Gasket 25-7C2-2 C2 Pump Head 25-84C2 C2 Roller Block (2 roller) 25-83C2-2 C2 Face Plate 25-85S #10-32 X 1 ¾ Machine Screw 25-85L #10-32 X 2 ¼ Machine Screw 25-C2D C2 Pump Head Kit (kit includes C2 Pump parts listed above) I-729 Pg 14 of 15

Return Policy No merchandise may be returned for credit without DEMA Engineering Company s written permission. Return Merchandise Authorization (RMA) number required in advance of return. Warranty DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to products that have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, improper voltage supply, physical abuse or misapplication. Rubber and synthetic parts such as O -rings, diaphragms, squeeze tubing and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval of DEMA, this warranty will be void. Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge. F.O.B. factory DEMA assumes no liability for damages. Return merchandise authorization number to return units for repair or replacement must be granted in advance of return. I-729 Pg 15 of 15