NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

Similar documents
NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3)

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

A STATE OF THE ART INTEGRATED CHEMICAL BIOLOGICAL & RADIATION WATER MONITORING SYSTEM

SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

Measurement Devices. Topic 5 - Audio 56

SENSITIVE ENOUGH TO DETECT RUNOFF FROM SECRET NUCLEAR PLANTS

AERIAL RADIATION DETECTORS

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

Ronan Model X96S Series Density System

LAUNDRY MONITORING SYSTEM Model # LIM-64S

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals

Portable Survey Instruments NISP-RP-01

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc.

Radiation Monitoring Systems

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

HEALTH AND SAFETY MANUAL

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

Identify the following features and specifications for the ESP1

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

C-NRPP Quality Assurance Guidance for Radon Test Devices

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

Ronan Model X96S Series Weighing System

CHARCOAL CANISTER (Activated Charcoal Adsorption Device) by Proportional Counting

A Continuous Air Monitoring Sampler for 125 I - RIS-125

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

Ronan Model X90 Series Point Level Monitor

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

COMPANY PROFILE. DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY

RAM GENE / RAM GENE-1

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Portable Instruments For First Response & In-Situ Analysis of Radiation

HEALTH AND SAFETY PROGRAM 406 IONIZING/NONIONIZING RADIATION PROTECTION

Laboratory Impex Systems Ltd

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

incubator, the best in its class

Radioactive Contamination Monitor

Maximizing safety and productivity. Nuclear Power Radiation Detection and Monitoring Solutions

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LUDLUM MODEL and PANCAKE CLUSTER DETECTORS. June 2016

Dosimeters/Survey meters

Seismic Countermeasures for Environmental Radiation Monitoring System

POSITRON EMISSION TOMOGRAPHY (PET) CENTER MONITORS

ATOMLAB XENON TRAP MONITOR OPERATION AND INSTALLATION MANUAL FN: /12

Certificate of Completion

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Radon Detection Specialists, Inc.

Radon Detection Specialists, Inc.

Surface Contamination Monitor. Operation Manual

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

Certificate of Completion

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement

Radon Detection Specialists, Inc.

Alpha Attenuation Due to Dust Loading. Amber E. Dailey Francis Marion University Savannah River Site

Air Resource Specialists, Inc.

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

300/400 UNITS - MODULAR CONFIGURATION

DIGITAL AREA RADIATION MONITOR

LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector. July 2012 Serial No. PR and succeeding Serial Numbers

Nuclear Associates

2.18 Air Sampling Equipment RCT Study Guide Identify the factors that affect the operator's selection of an air sampling system.

22 Radiological and Environmental Monitoring Systems Functions, Basic Configuration, and Interfaces

ß-Aerosolmonitor FHT 59 C

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

CURRENT STATE OF THE ART IN MEASURING ENVIRONMENTAL RADON. Abstract

Battery-operated, hand-held alarm and measuring instruments for radiation protection

Ranger EXP RADIATION A L E R T

VHP ARD BIODECONTAMINATION SYSTEM

Radon Detection Specialists, Inc. Love the Lungs You re With

Radon Detection Specialists, Inc.

Radiation Safety Guidelines for Non-Users

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

PORTASCANNER PORTASCANNER TM ISO TECHNICAL SPECIFICATIONS COLTRACO. for Door Fan & Room Integrity Testing. Ult rasonics since 1987

A comparison of emerging gamma detector technologies for airborne. radiation monitoring

Series 5000 Hydrazine Analyzer Model 60002

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Radiation Alert Frisker INTERNATIONAL

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

Radon Detection Specialists, Inc.

Certificate of Completion

Quality and Technology - Made in Germany -

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Passive Whole Body Monitoring Nuclear Power Industry Application Introduction to the Argos -5AB Zeus (Gamma Option) and the GEM

Area Monitor/Frisker Count Rate Meter Victoreen

Transcription:

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor FEATURES: DETECTS ALPHA, BETA AND GAMMA RADIATION AVAILABLE IN PORTABLE OR INSTALLED VERSION MEASURES AT OR BELOW EPA/DHS PAG LEVELS PROTECTIVE ACTION GUIDELING LEVELS AND MILITARY DRINKING WATER LIMITS REAL TIME, IN-LINE, CONTINUOUS MONITORS WATER CONTINUOUSLY FOR RADIATION HIGH SENSITIVITY NO REAGENT TANKS TO FILL NO WASTE STREAM EASY CALIBRATION PREVENT ACUTE HEALTH EFFECTS REDUCE RISK OF CHRONIC EXPOSURE ALSO DETECTS SOME ISOTOPES DOWN TO LOWEST EPA LEVELS APPLICATION: Install NEX-BETA-ABG on your water inlet pipe. It automatically and continuously monitors drinking water 24/7 to your entire facility for any radioactive contamination. Facilities with multiple water inlets may wish to install multiple NEX- BETA-ABG s Very few cities or water wholesalers monitor water continuously for radiation. Specifically designed to protect your people who are vulnerable to contaminants. Monitor drinking water against most Radioactive contaminants except H-3, C-14, S-35, Fe-55. PROBLEM: Drinking water sources are vulnerable to accidental or knowing contamination by individuals, groups, industry, medical labs, terrorists and from naturally occurring radioactive materials (NORM). As yet very few water districts have real-time radiation monitors in place to protect the water and the public.

SOLUTION: For the first time in a Continuous Real Time monitor the Model NEX- BETAABG solves this problem by continuously monitoring the water using ultra-sensitive, radiation detectors. The information from these detectors are analyzed and displayed in units of picocuries per liter. The count times are user settable in NexBeta-ABG-7 and calculations are automatically updated every 2 minutes, every hour and every day in NexBeta-ABG-9. The longer update times correspond with greater precision and increased sensitivity. Sensitivities in the daily updates each meet or exceed the DHS protective Action Guideline Levels for drinking water. Please see attached chart of measurements. Using TA Tried and True sample & measurement technology this detector measures emissions from any radioactive contaminants. Measurements of radiation concentration are logged 24 hr/ day, 7 day/week in NexBeta-ABG 9. DESCRIPTION: Model NEX-BETA-ABG-7 and 9 are radiation detecting water monitor /controllers for measuring of alpha, beta and gamma emitting radio nuclides. The electronics are microprocessor with LED/LCD display. The system is covered by TA's full one year warranty. On-site service contracts available in many areas. The alpha, beta flow cell and gamma detector are easily changed via disconnect fittings. All connections are sealed against leaks. The standard water moving system is based on a high precision pump. It has a 10 liter per minute capacity. System can also be operated using city water pressure in which case no pump is required. A wide range of pump capacities are available to meet users specific needs. The system detectors and electronics are ruggedly built. It comes complete with all cabling tubing and connectors in place and is ready to operate. 115 Volt 60Hz is standard; 220 Volt 50/60 Hz or battery operation are optional. Detectors in this system; 1. Alpha-Beta Detector: Consists of a light-tight detector assembly which interfaces with the sample via quick disconnect coax cables and medical grade hoses. The sample is viewed by a matched pair of 5'' diameter photo -multiplier tubes. 2. Gamma Scintillation detector has a sensitive 2 diameter crystal. The alpha-beta pulse analysis portion of this system conditions and analyzes the output from the photo-multiplier tubes by pulse height, duration and coincidence. Thereby permitting the system to exclude most background and noise counts. Sensitivity is enhanced by the use of stochastic resonance plus high gain, low noise PM tubes and pre-amps.

Flow Path Water Inlet port Pressure relief valve Particulate Pre-Filter (with optional additional Gamma Detector) Ultra Violet Sterilizer (Optional) Mass Flow Meter (Optional) Flow chamber with alpha-beta and gamma detectors Tested water is clean and returns to the drinking water line. No liquid scintillant or reagents are added No toxic or radioactive waste of any kind. Data:-Analysis-Display-Hard-Copy-DVD-ROM Archive (NexBeta-ABG-9) The concentration and total activity released and MDA levels are continuously calculated and recorded. Also, all data can be saved to the optional hard drive in spreadsheet format. SPECIFICATIONS: Alarms: Each alarm activates a relay. Relay alarms are available to the user. Sample temperature: measurements are most accurate in range 40o to 85oF. Instrument is still operational up to higher temporatures Optional: Cooler model Cool-33 for detector & sample is used in case of higher sample or ambient temperatures. SIZE AND WEIGHT: Dimensions: One assembly: 14 wide x 29 Electronics may be separated from detector electronics. Electronics is 7 wide x 10 tall (23lbs) Shipping weight: standard unit: 22Kg - excluding optional shielding NOTE: Optional thin Lead Sheet for shielding can be shipped with or shipped separately or overseas customers may wish to buy the lead sheet locally.

Alternative Uses: If water source is reservoir or river the particulate pre-filter with its own RAD Detector is recommended Monitor Liquid-waste-stream from plant or laboratory to maintain regulatory compliance.