LED Seamless VaporProof Fixture

Similar documents
LED Edge-Lit Flat Panels

LED Seamless VaporProof Fixture Installation Instruction

LED Edge-Lit Flat Panels

LED ROUND MINI PANELS

HIGH LUMINOUS EFFICIENCY

LED Shoplight fixture

110 lm w STANDARD SERIES

Dimmable LED Retrofit Kit

Installation Instructions PANOS 5.25

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

PANOS. Installation Instructions Square, 5.25 Round Flangeless, Downlight. The following installation instructions relate to the options below

INSTALLATION INSTRUCTIONS

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

LED Dusk to Down Fixture

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION In-Ground

INSTALLATION INSTRUCTIONS

Lumination TM Volumetric Retrofit Kit

INSTALLATION INSTRUCTION In-Ground Color Changing

Urbanlite. We light your world IK08 IP

MAXLITE RKT LED Retrofit Kit

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

Vaya Linear LP, White & Mono

ETG-LRP Series. 4 LED Remote Phosphor Linear Low Bay and High Bay Lighting. Figure 1-2 tube LRP with reflector shown

USER MANUAL. Read manual thoroughly prior to equipment set-up, operation or maintenance. Model Model

PH:

USER MANUAL. Read this manual thoroughly prior to equipment set-up, operation or maintenance. Model

PH:

Technical Application Guide for UP-SHINE LED wall lamp UP-WL08-8W

Light. can be. LED Edge-Lit Flat Panel AWESOME

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

Safety Information BEFORE YOU BEGIN CAUTION: CAUTION: CAUTION: IMPORTANT Observe all governing codes. IMPORTANT Use this oven only

Innovative Lighting Smooth Light Recessed Luminaires

User Manual. Glass Countertop Mechandiser Refrigerator. Single Door Model: 360GSM3HCB, 360GSM3HCW Pass-Through Model: 360GSM32HCB, 360GSM32HCW

Lumination TM Controls Accessory LPL Series Controller Box

CoreLine Waterproof the clear choice for LED

Affordable and reliable energy saving LED Lighting Luminaires

Installation Instructions

FPLHB - Fidelux Premier Linear Highbay

TROFFER RETROFIT KIT (TRK)

APPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces

Technical Application LED Pendant Light LUZ-PL W-W

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

LUXCOMFO TM LED Flood Light Datasheet

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-B

PRODUCT DATA SHEET LIGHTING PRODUCTS

WARRANTY LED ECO PANEL.

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-E

T8 Self Ballasted UL & CSA LED TUBE RETROFITS

Technical Application Guide for UP-SHINE LED Ceiling light

FDV BA- Lighting AS BA24-CL76-8WD

Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-S3.

Technical Application Guide for UPSHINE LED Ceiling light

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Technical Application. Guide for LDN-PL W LED Panel Light LDN-PL W-A LDN-PL W-A-D

Technical Application Guide for UP-SHINE LED Panel Light

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

CoreLine Batten the clear choice for LED

Technical Application Guide for UP-SHINE LED Frameless Panel Light UP-PL W-P

LED ECO PANEL.

performance PowerBalance, surface mounted Benefits Features Application Specifications

Recessed, suspended and surface mounting options Standard 81,000 hour L70 lifetime Premium 139,000 hour L70 lifetime 48 3/4" 2 1/4" 23 3/4" 1/4" 1/4"

Technical Application Guide for UP-SHINE LED Downlight

AGA TOTAL CONTROL. Model No. - TC3

Premium. Universal LED Vapor Tight T20G. Commercial lighting Industrial lighting Vapor tight light Linear High Bay Canopy

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

Ledinaire Batten Simply great LED

Parkade.

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

User Manual. Ice Cream Dipping Cabinets 178CPW47HC, 178CPSS47HC, 178CPW68HC, 178CPSS68HC

SUNIDEA CO.,LIMITED.

Canadian Model Number Designations. Models ending in... LED-8030M42 C-A = 347V LED-8030M42 -A = 120/277V LED-8030M42 C = 120/347V

Tetra MAX. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

LED Tri-Proof. LED Tri-Proof. T: +44 (0) E:

Technical Application Guide for UP-SHINE LED Track Light

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-L

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

CoreLine Wall-mounted the clear choice for LED

Vertical Open Air Merchandisers 189BVAC28HC, 189WVAC28HC, 189BVAC36HC, 189WVAC36HC, 189BVAC46HC, 189WVAC46HC,

Product Specifications

Technical Application Guide for UP-SHINE LED Frameless Panel Light

WARRANTY FLEXOPTIX HIGH BAY/FLOOD.

DHL-LP-LED Low Profile LED Linear High/Low Bay

Maxos LED General Lighting innovative, flexible solution delivers ideal light output

Sylproof Superia LED G2

Technical Application Guide for UP-SHINE LED Panel Light

Back Bar Refrigerator User s Manual

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

DOME SERIES. Data will be subject to change without notice. COMMERCIAL 1

A flexible and affordable retail toolbox

SPECIALTY LIGHTING NOTES: A Canadian Manufacturer

K L Lead LV 3 Integrated K C Center K E End K S Solo. 2700K and 3500K not available with.

SUBSTITUBE T8 CONNECTED TUBE

WINDSHEAR STORM and WINDSHEAR STORM DELUXE MODEL NO: 98778/98780

Be Off The Grid com Inc. Most Popular LED Lighting Product List

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

178GDC10HC, 178GDC12FHC, 178GDC15HC, 178GDC23HC, 178GDC24FHC, 178GDC40HC, 178GDC40FHC, 178GDS47HC, 178GDC69HC

New Linear Series DISCONTINUED

Transcription:

ASD LED Seamless Premium VaporProof fixture is a modern contemporary lighting fixture widely used in many different commercial and residential environments. It has many features that make it the perfect choice for wet and dusty locations. They can be used in car washes, warehouses, parking garages, stairwells, pool areas, etc. ASD LED Seamless Premium VaporProof fixture will significantly reduce energy consumption and decrease your energy costs. They are very easy to install and are the perfect replacement for your existing fluorescent fixture. A polycarbonate body makes this fixture impact resistant and able to maintain its luster over time. ASD LED Seamless Premium VaporProof fixture are maintenance-free and produce bright, high quality light without shadows. Our affordable price makes it an ideal option for any commercial or residential application. 125 lm IP66 rated w HIGH LUMINOUS EFFICIENCY FEATURES AND BENEFITS: Low energy consumption Contemporary design Polycarbonate body 4,K & 5,K available Luminous efficiency 125 lm/w ~1 V dimming Surface mounted luminaire Suitable for Wet Locations L-7 Life > 238, hrs DesignLights Consortium (DLC) listed (Classification: Premium) culus certified 5-year limited warranty ORDERING MATRIX: Family Modification Lens Size Dimmable ~1 V Watts CCT Series ASD-LVP 2S M X D XX XX PRM LED VaporProof Translucent white lens 4 = 4 ft Dimmable 31 = 31 W 4 = 4, K Premium 8 = 8 ft 6 = 6 W 5 = 5, K

LED SEAMLESS VAPORPROOF FIXTURE: Model Type Watts Dimming CCT Lumens Dimensions (LxWxH) ASD-LVP2SM-4D314PRM 4 ft 31 W YES 4, K 3,861 lm 48"x3.5"x3.2" ASD-LVP2SM-4D315PRM 4 ft 31 W YES 5, K 3,86 lm 48"x3.5"x3.2" ASD-LVP2SM-8D64PRM 8 ft 6 W YES 4, K 7,353 lm 94.5"x3.5"x3.2" ASD-LVP2SM-8D65PRM 8 ft 6 W YES 5, K 7,57 lm 94.5"x3.5"x3.2" PRODUCT SPECIFICATIONS: Construction & Materials Lens Translucent white lens Housing Polycarbonate white lens Finish Color White Weight 4 ft 4.6 lb (2.1 kg) 8 ft 7 lb (3.2 kg) Environmental System Work Environment Suitable for Wet Locations, IP66 Operating Temperature -4 to 14 (-2 to 4 ) L-7 Life > 238, hrs Optical System Luminous Flux ASD-LVP2SM-4D314PRM 3,861 lm ASD-LVP2SM-8D64PRM 7,353 lm ASD-LVP2SM-4D315PRM 3,86 lm ASD-LVP2SM-8D65PRM 7,57 lm Color Temperature 4, K, 5, K CRI >8 Electrical System Input Voltage 1~277VAC 5/6 Hz Max input current 4 ft 35 ma 8 ft 7 ma Inrush current 4 ft 35 A 8 ft 7 A Action time (Inrush current) 4 ft 7 μs 8 ft 45μs AC input range min 9 V max 285 V Off State Power W Power Consumption 4 ft 31 W 8 ft 6 W Power Factor.9 Output voltage 3-42 V Max output current 4 ft 7 ma 8 ft 1,5 ma LED driver class B, class 2 Regular and Voluntary Certifications 5-year limited warranty DesignLights Consortium (DLC) listed (Classification: Premium) culus certified E47384 luminaire E473855 driver DIMMING COMPATIBLE CONTROLS MFG Lutron Leviton Leviton Cooper Model Number NFTV IPL71 DLZ IPL71 DL SF1P-W Control Dimming Switch Standard ~1 V dimming 1% - 1%

LED SEAMLESS VAPORPROOF FIXTURE ORDERING INFORMATION: Model Type Watts CCT UPC GTIN 14 Product Code Pcs in one Carton Carton Size Carton Weight ASD-LVP2SM-4D314PRM 4 ft 31 W 4, K 8576226497 18576226494 23.12 9 51"x12"x11" 49 lbs ASD-LVP2SM-4D315PRM 4 ft 31 W 5, K 857622653 185762265 23.121 9 51"x12"x11" 49 lbs ASD-LVP2SM-8D64PRM 8 ft 6 W 4, K 8576226527 18576226524 23.123 4 98"x8.3"x7.5" 34.9 lbs ASD-LVP2SM-8D65PRM 8 ft 6 W 5, K 8576226534 18576226531 23.124 4 98"x8.3"x7.5" 34.9 lbs 4 ft 48" (122 mm) 3.2" (8 mm) 3.5" (9 mm) ASD-LVP2SM-4D314PRM ASD-LVP2SM-4D315PRM LUMINOUS INTENSITY DISTRIBUTION DIAGRAM MH(m) C PLANE ISOLUX DIAGRAM (UNIT:lx) LUMINOUS INTENSITY DISTRIBUTION DIAGRAM MH(m) C PLANE ISOLUX DIAGRAM (UNIT:lx) 3 1 2 2 1 3 1 2 S(m) 1 2 S(m) UNIT:cd UNIT:cd

8 ft 94.5" (24 mm) 3.2" (8 mm) 3.5" (9 mm) ASD-LVP2SM-8D64PRM ASD-LVP2SM-8D65PRM LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C PLANE ISOLUX DIAGRAM (UNIT:lx) MH(m) -15 -/+18 15 14 18-15 -/+18 15 14 18-12 12 22 26-12 12 22 26-9 9 5 1-6 15 6 2-3 25 3 UNIT:cd C/18,127.7deg C9/27,14.8deg AVERAGE BEAM ANGLE 5% :116.3 DEG 3 34 38 42 46. 17. 34. 13. 11. 8.8 6.6 4.4 2.2 1.8 1.1.88.66 S(m) -9 9 5 1-6 15 6 2-3 25 3 UNIT:cd C/18,127.7deg C9/27,14.7deg AVERAGE BEAM ANGLE 5% :116.2 DEG 3 34 38 42 46. 17. 34. 14. 12. 9.3 6.9 4.6 2.3 1.9 1.2.93.69 S(m)

WARNING RISK OF PERSONAL INJURY READ and follow all WARNINGS and installation instructions. Keep or give to the owner for future reference. Risk of cuts: Wear gloves to prevent cuts or abrasions when removing from carton, handling, installing, and maintaining this product. Risk of electric shock: This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Risk of Fire: Minimum 9 С supply conductors. Consult a qualified electrician to ensure correct branch circuit conductor. ASD assumes no responsibility for claims arising out of improper or careless Installation or handling of this product. AVERTISSEMENT RISQUE DE BLESSURES - Lisez et suivez toutes les MISES EN GARDE et les instructions d installation. Tenir ou fournir au propriétaire pour référence future. Risque de coupures: Porter des gants pour éviter les coupures ou des écorchures lors du retrait du carton, de la manutention, l installation et le maintien de ce produit. Risque de choc électrique: Ce produit doit être Installé conformément au code d installation applicable par une personne familiarisée avec la construction et l exploitation du produit et les risques impliqués. Risque d incendie: minimum 9 С Alimentation conducteurs. Consultez un électricien qualifié pour assurer le bon conducteur de circuit de dérivation. ASD n assume aucune responsabilité pour les réclamations découlant d une installation inadéquate ou négligente ou de la manipulation de ce produit. ADVERTENCIA RIESGO DE LESIONES PERSONALES Lea y siga todas las advertencias e instrucciones de instalación. Mantener о proporcionar al propletario para referencia futura. Riesgo de cortes: Use guantes para evitar cortes о abrasiones en la eliminación de la caja, manejo, instalación y mantenimlento de este producto. Riesgo de choque eléctrico. Este pfoducto debe ser instalado de acuerdo con el código de Instalación uplicable en que una persona familliarizada con la construcciôn y operación del producto y los riesgos Involucrados. Riesgo de Incendio: Minimo 9 С los conductores de suministro. Consuite a un etectricista calificado para asegurarse el conductor correcto del circuito. ASD no asume ninguna responsabilidad por reclamaciones derivadas de uno instaiación inadecuada о negfigente о la manipuloción de este producto.

INSTALLATION GUIDE IMPORTANT SAFETY INFORMATION: Please read all the instructions below before installation. Make sure that the supply voltage corresponds to the rated product voltage. The product must be installed by a qualified electrician in accordance with the National Electrical Code and corresponding local codes. If the product is damaged, do not use it. All wiring connections should be capped with UL approved wire connectors. For surface mount there are two stainless steel brackets included. This fixture is intended to be connected to a properly installed and grounded UL listed junction box with suitable strain relief means for power cord. The junction box is not included, should be purchased separately. CONNECTION DIAGRAM FIXTURE Black Black White Green INNER LINKING CORD White Green L (Black) L (Black) POWER CORD Dim - (Grey) FITTING N (White) Ground (Green) DRIVER N (White) Ground (Green) FITTING LINKING CORD Dim - (Grey) Dim + (Violet) Dim + (Violet)

INSTALLATION STEPS 1. Affix the mounting brackets to the ceiling/wall. Distance between the brackets (L1) should be 9.2" (2,29 mm) ± 1.2" (3 mm) 1. L1 2. 2. Remove four screws of the end-cap. 3. Pull out the end-cap with junction box. 4. Remove the cover of the junction box and remove the gasket. 5. Insert the power cord and -1V dimming wires in to the junction box, connect lines black to black, white to white, green to green, grey to grey, violet to violet. WARNING: if there is no ground supply wire, stop installation and consult a qualified electrician. Once wire connections and made, secure each with a wire nut (CC). 6. Close the cover of the junction box and insert it into the fixture. 7. Tighten the screws of the end-cap. 3. 4. 5. 6. 7. 8. 8. Affix the fixture to the ceiling/wall by mounting brackets.

CONNECTING MULTIPLE FIXTURES TO ONE SWITCH 1. Remove four screws of the end-cap. 2. Pull out the end-cap with junction box. 1. 2. 3. Remove the cover of the junction box and remove the gasket. 4. Insert the power cord and -1V dimming wires in to the junction box of the next linked luminaire, connect lines black to black, white to white, green to green, grey to grey, violet to violet. WARNING: if there is no ground supply wire, stop installation and consult a qualified electrician. Once wire connections and made, secure each with a wire nut (CC). 5. Close the cover of the junction box and insert it into the fixture. 3. 4. 5. 6. 6. Tighten the screws of the end-cap. LINKING LIMITS: Model Linkable Quantities Depending on Voltage 11V 2V 277V 4 ft 14 pcs 28 pcs 32 pcs 8 ft 7 pcs 14 pcs 16 pcs