PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Similar documents
PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Certificate of Conformity Certificate num. Registration date Version Valid until

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

FireFinder TM AS OPERATORS MANUAL

Device Compatibility Guide

Precept Marine Control Panel Application Guide

4010 Fire Alarm Parts List

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Intelligent Single Loop Fire Alarm Control Panel

Technical Data Sheet

Intelligent 2 & 4 Loop Fire Alarm Control Panels

The EN54 Part 2 & 4 Fire System

Fire control panels FC726 FC726-XA

LaserFOCUS VLF-250 Engineering Specification

Conventional Releasing Control Panel

Installation, Operating and Maintenance Manual

The EN54 Part 2, 4 and 13 Fire System

TrueAlarm Fire Alarm Controls

AND ARCHITECT SPECIFICATIONS

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Fire and Gas Monitoring Panel ST7-HV

Network Display Unit Installation Instructions

TrueAlarm Fire Alarm Controls

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

Certificate of Conformity Certificate num. Registration date Version Valid until

SECTION FIRE ALARM SYSTEMS

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

ZXSe Range Data Sheet

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Certificate of Conformity Certificate num. Registration date Version Valid until

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

Vigilant MX4428 Fire Alarm System

TrueAlarm Fire Alarm Systems

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

CITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM. Bid # Addendum #1

4100ES-S1 Fire Indicator Panel Installation & Maintenance

AU MX Digital Loop Card Installation Instructions

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Commercial and Light Industrial Fire Alarm Control Panel

Saxon Range 1-8 Zone Convertional Control Panels

NETWORK FIRE ALARM CONTROL PANEL. Features

INTELLIGENT FIRE ALARM CONTROL PANEL

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

AIRCRAFT TECHNICAL SPECIFICATIONS Dornier / MSN 3079

Addressable Fire Alarm Control Panel

Specification/ Data Sheet

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Document No Issue 4 user manual

Solution F2. Fire Alarm Control Panels one step ahead.

P/N Product Manual. Conventional Fire Alarm/Suppression System

DS7400Xi Addressable Control/ Communicator

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

On the job around the clock 24/7: Fire detection systems

MPC-6000 / MPC-7000 / RND-2

Panel Remote Annunciators Installation Instructions

AFP-2800/2802 Fire Alarm Panel

good things in small packages

The Kentec driver connects to the Kentec Syncro range of fire detection panels. Available for Commander and ObSys.

Equipment ATA 12 April 2016

FIRE ALARM SYSTEM FRCME AMS R2M SOM CZM DIMM. Serial. Annunciator. Printer ATG-EA ALK-V. Duct Detector SLC (DCP) Notification Alarm Equipment

Installation Instructions Model CDC-4

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

DESIGN PHILOSOPHY FOR FIRE ALARM & DETECTION SYSTEM

4100ES Fire Indicator Panel Installation & Maintenance

AND ARCHITECT SPECIFICATIONS

HART XL High Sensitivity Smoke Detection

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

HART XL High Sensitivity Smoke Detection

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

Fire Detection Systems Product Catalogue (Version )

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

FireNET Plus Wiring Instructions

CURTISS-WRIGHT CONTROLS INTEGRATED SENSING (CAGE CODE: 03972).

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

SECTION AUTOMATIC TRANSFER SWITCHES

Lake County / Multi-Department Storage Facility / Project / December 12, 2016 SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Intelligent Security & Fire Ltd

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

SECTION FIRE ALARM

Fire Alarm Control Panel CFP-16 OPERATION, INSTALLATION & PROGRAMMING MANUAL AUSTRALIAN EDITION. 26/05/2015 Rev D DOC

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

A. Provide addressable fire alarm system throughout the facility and supervise wet and preaction fire sprinkler system.

Transcription:

LISTING NUMER afp - 395 Commonwealth Scientific and Industrial Research Organisation, Australia Ph.: 61 3 9252 6000 Fax: 61 3 9252 6011 Web site: http://www.activfire.gov.au E-mail: info@activfire.gov.au Dates: Registration:...31-Jan-1990 Page 1 of 5 Version:..1.7...1-Aug-2007 Valid until :...31-Jul-2008 PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment) Product designation Simplex, Model 4100, fire indicator panel (Refer to the Technical Specification section of this document for further specific detail) Supplier Simplex Fire Products 47 Gilby Road, MOUNT WAVERLEY, VIC, AUSTRALIA, 3149 Manufacturer Simplex Time Recorder Co. Simplex Plaza, GARDNER, MA, USA, 01441-0001 Supplier's description The Simplex, Model 4100, fire indicator panel is a microprocessor based fire alarm system. The basic 4100 system contains eight initiating device circuits, two indicating appliance circuits, two auxiliary alarm relays, an interface board for local annuciators, a trouble relay, and a configurable notification circuit. The Simplex, Model 4100, fire indicator panel contains a Master Controller Card, Field Wiring Termination, 80-character Alphanumeric Display, Power Supply, and enclosure. Optional combinations of up to 512 alarm zones and signal circuits can be fitted. provision is made for serial communication with remote equipment. Audible and visual indications are provided to indicate abnormal conditions when they exist within the system. An Alarm Acknowledgment (AAM), consisting of a wall-mounted faceplate housing a normally open momentary pushbutton and high intensity red LED, Simplex Model 4098-9714EA Photoelectric Smoke Detector mounted on a Simplex, Model 4098-9794 base assembly, and a Simplex 4090-9001 Input Alarm can be optionally fitted to the Simplex, Model 4100, fire indicator panel. Conformance criteria and evaluation The Simplex, Model 4100, fire indicator panel complies with the requirements of Australian Standard AS 4428.1-1998, 'Fire detection, warning, control and intercom systems - Control and indicating equipment - Fire' and Australia Standard AS 1603.4-1987, including amendment numbers 1 & 2, 'Automatic Fire Detection and Alarms Systems, Control and Indicating Equipment'.. Listing is subject to ActivFire Scheme terms and conditions as applicable to the designated registrant and supplier. This product listing data sheet should be read in conjunction with the general requirements of the terms and conditions of listing under the ActivFire Scheme. CSIRO Australia, 2007 Executive Officer

afp - 395 Registration:... 31-Jan-1990 Page 2 of 5 Limitations/conditions of conformance Limitations/conditions of conformance, where identified on this Product Listing Data Sheet, are derived from qualifications within the report of the testing agency and/or other related technical documentation. It is recommended that all details with respect to design, assembly and installation restrictions should be checked against the designated supplier's/manufacturer's current technical manual/data sheets and the requirements of the Authority having Jurisdiction. Compatibility of the Simplex, Model 4100, fire indicator panel with detectors and base assemblies should be confirmed prior to installation. Technical specification The following details are a representative extract of the technical specification for the Simplex, Model 4100, fire indicator panel and may be subject to change. Complete and current details should be determined from the designated supplier's/manufacturer's technical manual/data sheets. Power Supply Model: 562-808 Nominal output voltage: 27.4 V Maximum rated output current: Circuit current limit: AC secondary fuse rating: attery Charger Voltage setting: Circuit current limit: AC secondary fuse rating: 27.4 V 0.8 A Panel Quiescent load: 0.72 A @ 27.4 V Maximum power supply load requirement: 1.16 A attery capacity for 8 AZF's: 21.7 AH (Incorporating 4 daughter cards & 32 remote zones) Manufacturer's nominated battery capacity: 38 AH Tested s: Master Controller Display oard External Serial Interface Communication Supplementary information Number Rev PC Number 562-711 562-770 562-794 Iss A11 Tech. Drawing Number Iss Test Report 841-633 841-643 562-793 D 562-792 A 841-728 8 point Monitor 562-731 562-730 841-616 C Signal Card Relay 6 Circuit 562-755 652-752 C 841-625 C Signal Card Relay 2 Circuit 562-782 562-752 C 841-625 C Motherboard Class 562-799 C - - 841-646 A Motherboard Class 562-727 A - - 841-617 rigade Interface 002-039 - 001-552 - 002-039-S - 89/FS218, Dec.-1989, AS 1603.4-1987

afp - 395 Registration:... 31-Jan-1990 Page 3 of 5 Tested s: (continued) Number Rev PC Number Iss Tech. Drawing Number Iss Test Report 4100 Fuse Card Secondary 002-038 - 001-531 - 002-038-S - 89/FS218, Dec.-1989, 8 LED 562-822 - - 841-624 A AS 1603.4-1987 16 LED 562-806 - - 841-618 A 8 LED Switch 562-814 - - 841-622 A 16 LED/8 Switch 562-747 - - 841-623 A 16 LED/8 Switch 562-805 - - 841-623 A attery Test 002-045 - 015-549 - 002-045-S - Power Supply 562-808 ER 562-807 841-651 E Remote Control oard 562-819 D - - 841-655 Remote Control Unit 562-876 A - - 841-655 16 LED oard (Status Com. Unit) Remote (Serial Interface oard) 562-817 A - - 841-654 C 562-791 - - 841-728 Graphic I/O 562-789 562-788 - - 89/FS218, Dec.1989, LED Switch Controller 562-729 C 562-728 C 841-615 AS 1603.4-1987 Status Command Unit - - 962-794 841-654 C Alarm Acknowledgment Simplex Modular Network Interface Card (NIC) Simplex RS485 Media for NIC Simplex Fibre Optics Media for NIC Simplex 8 zone Monitor Card P/N 4100-5004 (conventional zone interface card) AAM XF1689/R1, Sep 2000 SSL Test Specification FTS-136 v1.4 565-516 656-515 - XF1727/R1, Jun 2001 AS 4428.1-1998 565-413 565-413 C - 565-261 D 565-261 D - 565-226 D 565-226 C - EPROMS: 4100 Master U34 Phase 1 U33 REM us 740-633 SCU Fan 740-602 Rev. 1.05 4/10 23D9 Rev 1.06.01 18/9/89 5/5/89 8/9/89 Rev. 1.02 1/12/89 Rev 1.06 16/11/1988 & 1/12/1989 Network Interface card U6 DNET 4100 4100 Lower U149-0 4100 Upper U16-0 740-927 3.02.93-6A31 Date 23/1/98 Rev A9.02.15 Rev A9.02.15 Activating Devices: Activating device AAM Test report Simplex, 4098-9714 Smoke with Simplex 4098-9794 base 500 XF1689/R1 Sep. 2000 SSL Test Specification FTS-136v1.4

afp - 395 Registration:... 31-Jan-1990 Page 4 of 5 Activating Devices (continued_ Activating device Maximum number of devices allowed per AZF562-731 Rev 8 Pt Monitor Card Test report Apollo, Series 60 P/N 55000-105AUS Heat Type A X1065, 29-Apr-93, Apollo, Series 60 P/N 55000-106AUS Heat Type Compatibility Report Apollo, Series 60 P/N 55000-107AUS Heat Type C Apollo, Series 60 P/N 55000-108AUS Heat Type D Apollo, Series 60 P/N 55000-204AUS Heat Smoke Apollo, Series 60 P/N 55000-310AUS Heat Smoke The above detectors with Apollo 45681-200 base Cerberus, DO1191A eam 1 XF1535/R1, 01-Mar-99, Compatibility Report Hochiki, DCA--60R Mk V Heat Type A 89/FS218, Dec. 1989, Hochiki, DCA--90R Mk I Heat Type C AS 1603.4-1987 inc. amdt 1 & 2 The above detectors with Hochiki YC-RL/4AH4 base. Hochiki, DCC-A Heat Type A X0994, 16-Dec-92, Hochiki, DCC-C Heat Type C Compatibility Assessment The above detectors with Hochiki YF-RL/4AH4M or YC-R/3A base. Hochiki, DCD-A Heat Type A XF1252/R2, Feb. 1998, Hochiki, DCD-C Heat Type C Compatibility Assessment The above detectors with Hochiki YO-R/4A base. Hochiki, DFE-60 Heat Type X0994, 16-Dec-92, Hochiki, DFE-90D Heat Type D Compatibility Assessment The above detectors with Hochiki YC-RL/4AH4 base. Hochiki, DFJ-60 Heat Type XF1252/R2, Feb. 1998, Hochiki, DFJ-90D Heat Type D Compatibility Assessment The above detectors with Hochiki YO-R/4A base Hochiki, HF-24A Mk I UV Flame 14 89/FS218, Dec. 1989 Hochiki, SIF-A Mk I Smoke with Hochiki YC-RL/4AH4 base. AS 1603.4-1987 inc. amdt 1 & 2 Hochiki, SIJ-ASN Smoke with Hochiki YO-R/4A base XF1252/R2, Feb. 1998, Compatibility Assessment Hochiki, SLG-A Mk I Smoke 89/FS218, Dec. 1989, Hochiki, SLK-A Smoke Compatibility Assessment The above detectors with Hochiki YC-RL/4AH4 base. Hochiki, SLR-AS Smoke with Hochiki YO-R/4A base XF1252/R2, Feb. 1998, Compatibility Assessment * The maximum allowed by code.

afp - 395 Registration:... 31-Jan-1990 Page 5 of 5 Activating Devices: (continued) Activating device Maximum number of devices allowed per AZF562-731 Rev 8 Pt Monitor Card Test report Olsen, 111 eam Smoke SSL Letter, 21-Jun-1991, Olsen, C24 Smoke 33 Compatibility Assessment Olsen, C29Ex Smoke The above detectors with Olsen Z54 base Olsen, C29Ex Smoke with Z54Ex base SSL Letter, 21-Jun-1991, Olsen, P24 Smoke 25 Compatibility Assessment Olsen, P29 Smoke 20 The above detectors with Olsen Z54 base Olsen, R23 Infrared Flame 19 SSL Letter, 21-Jun-1991 Olsen, R24Ex, R24 Infrared Flame 3 Compatibility Assessment Olsen,T54 Probe Heat Olsen, T56, Heat Type A,, C or D with Olsen Z54 or Z55 base. Olsen, V41/V42 UV Flame Olsen/Cerberus, FW81 Type E H/D Cable 1 rooks, PFS-A Heat Type A X0808, Mar. 1992 rooks, PFS- Heat Type Compatibility Assessment rooks, PFS-C Heat Type C rooks, PFS-D Heat Type D rooks, PFS-I Smoke 24 rooks, PFS-I MkII Smoke rooks, PFS-P Smoke 24 rooks, PFS-P MkII Smoke 31 The above detectors with rooks PFS-A MkII base. Simplex, 2098-9201 Smoke XF1017, Sep.1994 Simplex, 2098-9576 Smoke Compatibility Assessment Simplex, 4098-9413 Heat Type A Simplex, 4098-9414 Heat Type Simplex, 4098-9415 Heat Type C Simplex, 4098-9416 Heat Type D The above detectors with Simplex 2098-2911 base Simplex, 4098-9601EA, Smoke Photoelectric 30 XF1727/R1, Jun 2001 Simplex, 4098-9603EA, Smoke Ionisation 30 AS 4428.1-1998 Simplex, 4098-9618EA, Heat Type A 30 Simplex, 4098-9619EA, Heat Type 30 Simplex, 4098-9621EA, Heat Type C 30 The above detectors with Simplex 4098-9788EA base * The maximum allowed by code.